t 4

e Form 34731 (3 84)

(1) ID No.HP/0/B/1009/04 DUKE POWER COMPANY Change (s) n to PROCEDURE PROCESS RECORD n

incorporated PREPARATION (2) STATION CATAk'BA NUCLEAR STATION (3) PROCEDURE TITLE ENvTunNMFVPAT. MONITORING FOR EMERCENCY CONDITIONS WITHIN THE TEN MII.E RADIUS OF CATAk'BA NUCLEAR STATION 2b (4) PREPARED BY T A

DATE

~

NM DATE 2"27' b

(5) REVIEWED BY v

d> '- >'

Cross Disciplinary Review By J

N/R q

(6) TEMPORARY APPROVAL (if Necessary)

By (SRO) Date By Date (7) APPROVED BY I ~

DATE (8) MISCELLANEOUS e

Reviewed / Approved By Date Reviewed / Approved By Date COMPLETION (9) DATE(S) PERFORMED (10) PROCEDURE COMPLETION VERIFICATION O Yes O N/A Check lists and/or blanks properly initialed, signed, dated or filled in N/A or N/R, as appropriate?

O Yes O N/A Listed enclosures attached?

O Yes O N/A Data sheets attached, completed, dated and signed?

Oyes O N/A Charts, graphs, etc. attached and properly dated, identified and marked?

O Yes O N/A Acceptance criteria met?

4 l

VERIFIED BY DATE (11) PROCEDURE COMPLETION APPROVED DATE (12) REMARKS i

8605290576 860425 hDR ADOCK 05000413 P.DR'-

e--,

n

,r,

,g y

m

.g g,,

an.*

--w

~

w w

w n+ w-*~er--

t l

HP/0/B/1009/04 DUKE POWER COMPANY CATAWBA NUCLEAR STATION ENVIRONMENTAL MONITORING FOR EMERGENCY CONDITIONS WITHIN THE TEN MILE RADIUS OF CATAWBA NUCLEAR STATION 1.0 PURPOSE.

I To provide a method for identifying gaseous plumes or liquid effluent, and obtaining field data indicative of the radiation exposure to the general public following a suspected uncontrolled release of radioactivity. This l

procedure shall also be implemented by the Crisis Management Center once it is activated.

2.0 REFERENCES

2.1 HP/0/B/1000/06 Emergency Equipment Functional C1.eck and Inventory 2.2 HP/0/B/1002/04 Collection of Operational Environmental Weekly Samples 2.3 HP/0/B/1002/05 Collection of Operational Environmental Monthly Samples

[)

2.4 HP/0/B/1002/06 Collection of Operational Environmental Quarterly L'

Samples i

2.5 HP/0/B/1002/08 Collection of Operational Environmental Semimonthly Samples 2.6 HP/0/B/1002/10 Collection of Operational Environmental Semiannual Samples e

2.7 HP/0/B/1003/05 Operating and Calibration Procedure: Eberline Model PIC-6A Portable Ion Chamber 2.8 HP/0/B/1003/12 Operating and Calibration Procedure: Eberline Model E-520 Portable Beta-Gamma Geiger Counter 2.9 HP/0/B/1003/17 Operation and Calibration Procedure: Canberra Series

- 10 Portable MCA 2.10 HP/0/B/1003/31 Operation and Calibratica: Eberline Model E140N Portable Count Rate Meter 2.11 HP/0/B/1409/16 Distribution of Potassium Iodide Tablets in the Event of a Radiciodine Release 4

2.12 HP/0/B/1009/19 Emergency Radio System Operations, Maintenance and Communications 4

d e

--,.----,.r.

,-y---,,.--~,.1

,,__,.,,._~.m-.,.,.-..,,.._,.,.rm.

,,-,,,mm,.w.,,.m.,

e t

KP/0/B/1009/04 Page 2 of 7 3.0 LIMITS AND' PRECAUTIONS 3.1 The Field Monitoring Teams (FMT) should park vehicles completely off the road when sampling and use vehicle emergency flashers while stopped.

3.2 Four (4) FNTs consisting of two (2) technicians per team and one (1) helicopter team (1 person) if necessary shall be formed as follows:

Team Call Signs Transportation Alpha Land Vehicle Bravo Land Vehicle i

Charlie Land Vehicle Delta Land Vehicle Echo Belicopter 3.3 Each FMT shall use particulate masks and protective clothing whenever activity justifies it or when directed by the Field Monitoring Coordinator (FMC).

3.4 If the team membeys are expected to be exposed to I-131 in excess of 70 MPC (6.1 x 10 pCi/al), and directed by the FMC, each team member should ingest a tablet of potassium iodide per Reference 2.11.

(,

3.5 Environmental sampling during emergency conditions shall not replace, but rather supplement normal environmental monitoring. --

3.6 hinimum labeling requirements for all samples are as follows:

3.6.1 Date and time.

3.6.2 Location.

3.6.3 Volume of the sample (if applicable).

3.6.4 Name of person sampling.

3.7 Each FMT shall maintain open radio communications with the FMC per Reference 2.12.

If a radio becomes inoperable telephone the following:

3.7.1 FMC in the TSC at 831-8182 (Lake Wylie/ Charlotte).

3.7.2 Station PBX operator at 831-2282 (Lake Wylie/ Charlotte).

~

861-0331 (Gaston County), 324-3128 (Rock Hill / Fort Mill),

and request ext. 2598 for FMC.

3.8 If any equipment becomes inoperable, notify the FMC and wait for further instructions.

3.9 Annual training in the use of this procedure and the associated equipment and instrumentation shall be conducted and documented on TSR-10.

~

i i,

k

e

~

HP/0/B/1009/04 Page 3 of 7

'3.10 Portable MCA's shall be picked up at the Health Physics Counting Room when directed by the FMC. Ensure that the dewars are adequately filled per Reference 2.9.

)

3.11 Ensure that portable survey instrumentation is on and monitored i

during transport to all sampling locations.

l 3.12 When returning kits to the Emergency Kit Storage Room, perform an equipment inventory check using the Environmental Survey Kit Checklist (Reference 2.1).

Note deviations and forward to the Respiratory / Instrument Calibration Supervisor.

4 4.0 PROCEDURE ij 4.1 Activation H

4.1.1 Upon notificaton and assembly (FMC), the FNT members shall:

4.1.1.1 Report to the Health Physics area on the 609' elevation (on back shifts report to Administration Building) and wait for further instructions from the FMC.

4.1.1.2 Report to the Emergency Kit Storage Room in the

/ ~

Temporary Administration Building to get Environmental Survey Kits.

Nj 4.1.1.3 Ensure the tamper seal on the Environmental.

Survey kits have not been broken and inventory any that have (Reference 2.1).

4.1.1.4 Immediately place batteries in the portable survey instruments and make a communication check with TSC, using the portable FM radios.

4.1.1.4.1 Perform a battery check and. survey the area for higher than background

l radiation levels.

i t ll 4.1.1.4.2 Report any above background

'rediation levels to the FMC. As advised by the FMC, move to a low background area to complete source checks.

4.1.1.5 Source check survey instruments and portable MCA for proper operation (References 2.7, 2.8, 2.9, 2.10) if applicable.

4.1.1.6 Don TLD, high and low range dosimetry, and fill out dose cards.

i I

4.1.1.7 Ensure the Portable Power Generator is operational and the gas can is fully fueled (Reference 2.1).

,_,_....w..__.

_.,_,..,..,.,-,m.

l O

t EP/0/B/1009/04 Page 4 of 7 4.1.1.8 Obtain emergency vehicles as directed in

..9.

4.1.1.9 Each FNT will proceed to the survey point assigned by the FMC (Enclosure 5.3).

4.1.1.10 The radio operator in the TSC shall complete Radio Operators Los Field Monitoring Data Sheet (Enclosure 5.4), with the appropriate information.

4.2 Locating and Tracking the Plume 4.2.1 At the assigned survey point', the FMT shall perform a general area Beta-Gamma surveys This method should be used to locate center and width of plume.

4.2.1.1 Record date, time, location and dose rate (ar/hr) on the Field Monitoring Data Sheet (Enclosure 5.5).

4.2.2 If survey results are less than or equal to expected i

background, call in the results to the FMC and wait for j;

further instructions.

4

/ ~'s 4.2.3 If survey results are greater than background, take

(

protective actions as necessary. Then, if directed, take an air sample (volume should be > 108 al) equipped _with.a Silver Zeolite Cartridge and particulate filter.

4.2.3.1 Insert cartridge with arrow pointing in.

4.2.3.2 Insert filter paper with smooth side facing out.

4.2.3.3 Calculate required sample time per Enclosure 5.6.

4.2.3.4 Place the electrical generator (gas powered or mounted generator in the vans) in service and start the air sampler ensuring the sampler is approximately two feet above the ground or higher.

4.2.3.4.1 Gas power generators should be kept from wet areas and handle with j

electrical gloves contained in the i

environmental monitoring kit.

4.2.3.4.2 Hounted electrical generation located in the energency vans should be operated as follows to.

4.2.3.4.2.1 Ensure the engine of the van is running before energizing the generator.

1

,.,.,,,__,,,._w._,,

.,_._,.-,,,._,_n,_,.r,._

.,.-..-,,-,_..----.y--,,_-,9.-

,.c,

--,.w--v-,--,,,-,-.

e

.s HP/0/B/1009/04 Page 5 of 7 4.2.3.4.2.2 Ensure the engine, is running continiously if the generator is being used.

4.2.3.4.3 Ensure all sampling equipment is off the roadway for safety reasons.

4.2.3.5 When air sampling is complete, place the Silver Zeolite Cartridge in a thin plastic bag (baggie) for analysis. For transporting or storage place this into a labeled " zip-lock" bag.

4.2.3.6 Place filter in a separate poly bag and label.

4.2.3.7 As directed by the FMC, transport the completed sample to a vehicle that is carrying a Canberra Series - 10 Portable MCA for analysis per Reference 2.9.

4.2.3.8 Ensure the correct information is annotated on the Field Monitoring Team Work Sheet for Determining Iodine Activity (Enclosure 5.7).

4.2.3.9 Wait for further instructions from the FMC.

s.,

4.3 Special Sampling, as directed:

4.3.1 When sampling away from the emergency vehicles and no one is present to monitor the radio do the following:

4.3.1.1 For the emergency vans, ensure the exterior speaker is on and volume turned up.

Switch located near the radio monitor on the right side of the drivers seat.

4.3.1.2 For other Station vehicle or personnel vehicles, carry the portamoble radio to the sampling location.

4.3.2 All sampling outside of Auxiliary, Service and Turbine Buildings should be done in conjunction with Operations Support Center (OSC) personnel.

4.3.3 Take smears and place them in separate poly bags, label and retain for later analysis.

4.3.4 Count smears on E140N and record on Field Monitoring Data Sheet (Enclosure 5.5).

Call in results to FMC.

4.3.5 Collect water samples in cubitainers using good Health Physics practices and label and retain for later analysis.

j

HP/0/B/1009/04 Page 6 of 7 4.3.6 Place TLD's in the environment.

4.3.7 Retrieve and replace air sample and/or TLD's that are already located in the environment. Locations are listed in Enclosure 5.1.

Place samples in separate poly bags, label and retain for later analysis.

l 4.3.8 Collect broad leaf vegetation sample label and retain for later analysis (Reference 2.3).

4.3.8.1 Cut vegetation in a one square meter area approximately two inches above the ground.

l 4.3.8.'2 Seal closed by taping the poly bag.

NOTE:

Vegetation which leaves are not in the shape of needles, i.e. pine or spruce needles.

4.3.9 Collect shoreline sediment sample (one liter) label and retain for later analysis (Reference 2.6).

4.3.10 Collect milk sample (one full cubitainer) label and retain for later analysis (Reference 2.5).

Locations are listed in Sample Enclosure 5.2..

4.4 Contamination Control Considerations 1'

4.4.1 Don Anti-Cs inside the vehicle before leaving the i

vehicle.

4.4.2 Paper Anti-Cs should be used over cloth Anti-Cs and discarded before re-entering the vehicle.

4.4.3 Once a release has occurred, vehicle windows should be closed with ventilation off (unless filtration or recirculation is available on the ventilation) to minimize contamination until the plus area is identified.

Depending on weather conditions (extreme heat or cold),

this may not be possible.

4.5 Turnover J

4.5.1 Each FMT shall be relieved as directed by the FMC.

4.5.2 Inform the relief FMT on the status of the following:

4.5.2.1 Radiation surveys and dose rates in the plume area.

4.5.2.2 Kit Inventory consumed.

4.5.2.3 Equipment operating status.

i 4.5.2.4 Any sampling problems.

t

-. -. _ ~

~ ~... _. - _. - _.. -, _ _. - -, _ _ - - - ~ _ _ _ _ _ _ _,. - _ _,. _ _

. - -.. _. - -. _ ~ _., - -. - _..

HP/0/B/1009/04 l

Page 7 of 7 4.5.2.5 Plant status information.

4.5.3 Direct the relief RfT to don TLD's and pocket dosimetry and I

fill out dose cards.

4.5.4 Return all samples to the Emergency Kit Storage Room as directed by the FMC.

4.5.5 Turn in all data sheets to the FMC or his designee.

5.0 ENCLOSURES 5.1 Air, Sampler, TLD, and Water Sample Locations 5.2 Milk Sample Locations 4

5.3 Predetermined Sampling Locations 5.4 Sample of Radio Operators Los Field Monitoring Survey Data 5.5 Sample of Field Monitoring Data Sheet 5.6 Sample Time Required For Minimum Sample Volume i

5.7 Sample of Field Monitoring Team Work Sheet For Determining Iodine Activity 5.8 TSC Field Monitoring Organization 5.9 Emergency Vehicles

'6 s

4 t

I i

__--.m..y.-__,,,. _ _ _,

,,-,_v,.

,,.,, _ - - -., _ _ _. _ ~ _ _ _.. _,

e Page 1 of 9 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS AIR SAMPLE LOCATIONS (NEED XEY, CPD-1)

ZONE & RADIUS (Mi)

No.

DESCRIPTION it A0 1

1 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in' road, right at fork for 1.1 miles to end of road (TLD &

l' Air CNS #200, need key).

i A0 1

5 Left exiting Steam Production entrance on Concord Rd. for 1.2 miles, left on Old 4'

Concord Rd. for.3 miles, right on Acacia

],

Rd. for.3 miles, left on Crepe Myrtle Rd.

for.7 miles, left on Blue Bird La. for.1 miles to esd (TLD & Air CNS #201, need key).

1

(

A0 1

26 Location at the base of Catawba Nuclear Station Meterological Tower (TLD &,Ai.r.,,

CNS #205, need key).

El 3

1 Hwy. 49-N for 8 miles, right Hwy. 160 for 2.8 miles, right on Gold Hill Rd. (98) at Tega Cay sign for 1.2 miles, right on gravel road into Duke Power Company substation (TLD

& Air CNS #212, need key).

)

C2 10 5

Hwy. 274-5 for 5.1 miles, left Hwy.161 for

-i 1.3 miles, right on Rawlinson Rd. (56) for 1.8 miles, left on Hwy. 5 for 1.6 miles, right on Heckle' Blvd. (901) for 3.3 miles p

to end of road, left on Hwy. 72 for 1.2 miles, right on dirt road across from Wayne's Auto Service. Go.1 miles to Duke

!o Power Company substation on left (TLD & Air CNS #217, need key).

A0 1

1 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, 'right at fork for 1.1 miles to end of road (TLD &

Air CNS #200, need key).

-...._..,._..,,._r._,-

y

e i

i e

Page 2 of 9 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 h

AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS H

AIR SAMPLE LOCATIONS (NEED KEY, CPD-1) 1 1

ti ZONE & RADIUS (Mi)

No.

DESCRIPTION i:

A0 1

5 Left exiting Steam Production entrance on L

, Concord Rd. for 1.2 miles, left on Old

]l.

Concord Rd. for 3 miles, right on Acacia g

Rd. for.3 miles, left on Crepe Myrtle Rd.

l for.7 miles, left on Blue Bird Ln. for.1

[

miles to end (TLD & Air CNS #201, need key).

b c

A0 1

8 Left exiting Steam Production entrance on Concord Rd. for 1.2 miles, left on Old Concord Rd. for.3 miles, right on Acacia Rd. for.3 miles, left on Crepe Myrtle Rd.

Go.3 miles to first drive on right past Paradise Pl., TLD across road (TLD CNS

(

  1. 202).

~'

A0 1

11 Left exiting Steam Production entrance'on j

Concord Rd., for 1.2 miles, left on Old j

Concord Rd. for.3 miles, right on Acacia Rd. for.3 miles, left on Crepe Myrtle Rd.

for.2 miles. TLD is on left in curve (TLD CNS #223).

]

A0 1

14 Inft exiting Steam Production entrance on

]

Concord Rd. for 1.2 miles, left on Old Concord'Rd. for.3 miles, right on Acacia j

Rd. for.2 miles. TLD is on right side of road (TLD CNS #224).

A0 1

17 Left exiting Steam Production entrance on j'

Concord Rd. for 1.1 miles to first transmission tower on left after bridge (TLD CMS #225).

A0 1

20 Left exiting Steam Production entrance on i

concord Rd. for.7 miles. TLD on left just past fence (TLD CNS #226).

i i

e a

Page 3 of 9 DUKE POWER COMPANY m

CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS AIR SAMPLE LOCATIONS (NEED XEY, CPD-1) l ZONE & RADIUS (Mi)

No.

DESCRIPTION A0 1

23 Left exiting Steam Production entrance on Concord Rd. for.4 miles. TLD on left at beginning of guardrail posts (TLD CNS #204).

A1 4

2 Hwy. 49-N for 6.5 miles to the intersection of Pleasant Hill Rd. (1109). TLD is on the transmission tower on left (TLD CNS #232).

A1 4

4 Hwy. 49-N for 6.5 miles, right on Pleasant Hill Rd. (1109) for.5 miles, right on Youngblood Rd. (1102) for.6 miles, left on*

Zoar Rd. (1105) for.4 miles, right on 7

Thomas Rd. (1104) for.1 miles. TLD is behind second house on.

31 3

1 Nwy. 49-N for 8 miles, right on Rwy. 160 for 2.8 miles, right on Gold Hill Rd. (98) at Tega Cay sign for 1.2 miles, right on gravel road into Duke Power Company

. substation (TLD & Air CNS #212, need key).

31 3

Ewy. 49-N for 8 miles, right on Rwy. 160 for 3.9 miles, right on Das Rd. (99) for i

1.9 miles to last gravel road on right in sharp curve before Lake Wylie Dam, lef t through fence for.2 miles to substation.

l TLD on right of inner substation fence (TLD CNS #235).

32 4

2 Hwy. 49-N for 8 miles, right on Rwy.160 for 2.8 miles to the Home Federal Savings and Loan on left side of road. TLD on barbed wire fence approximately 50 yds.

behind bank (TLD CNS #234).

e 4

i d

l Page 4 of 9 i

DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS 1

AIR SAMPLE LOCATIONS (NEED KEY, CPD-1)

?

ZONE & RADIUS (Mi)

No.

DESCRIPTION B2 7

6 Hwy. 49-N for 8 miles, right on Hwy.160 f

for 7.1 miles, right on Lee St. for.1 miles, left on Self St. for approximately i

100 yds. TLD at Fort Mill Municipal Water Supply on right behind Springs Mill (TLD CNS #247, Water CNS #213).

B2 8

1 Hwy. 49-N for 10 miles, right on Carowinds Blvd. (1441) for 1.3 miles, left on Choate Circle for.3 miles, TLD is on the inside of fence left of the guardhouse (TLD CNS i

  1. 246).

}i A0 1

26 Location at the base of Catawba Nuclear i

6 Station Meterological Tower (TLD & Air CNS

(

  1. 205, need key).'

A0 1

29 Left exiting Steam Production entrance on Concord Rd. for.1 miles'. TLD at Shady Shore Dr. on right corner of.

1 A0 1

32 Right exiting Steam Production entrance on Concord Rd. for.1 miles. TLD is on right l

side of entrance to Valelake Rd. (TLD CNS l

  1. 228).

b A0 1

35 Right emiting Steam Production entrance on Concord Rd. for.4 miles. TLD on top of hill on right at the intersection of Catawba Nuclear Station Construction entrance (TLD CNS #206).

k

)

I I

- - - - - -... -.. - s

Page 5 of 9 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 4

AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS AIR SAMPLE LOCATIONS (NEED KEY, CPD-1) t ZONE & RADIUS (Mi)

No.

DESCRIPTION A0 1

38 Go through Construction Maintenance Dept.

~

(Central) Main Gate for approx. 50 ft.,

left on Alternate 1 for approx. 200 ft. to l'

stop sign, left on gravel road for.1 miles, left into rebar yard for.7 miles on gravel road to end at chain link fence.

Follow chain link fence in a northerly direction for approx. 300 yds. TLD is hanging on fence (TLD CNS #229).

A0 1

41 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, right at fork for.4 miles. TLD on fence ;

on right (TLD CNS #207).

A0 1

44 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, right at fork for 1 mile to large rock pile l

at fence. TLD is on fence (TLD CNS #222).

I A0 1

45 Left exiting Steam Production entrance on Concord Rd. for 1.2 miles, left on Old i,

Concord Rd. for 1.4 miles to end of road.

!1 TLD is on fence on the left side (TLD CNS

'I

  1. ,203).

C1 4

1 Ewy. 274-S for 3.8 miles, left on Mt.

l; Gallant Rd. (195) for 5.2 miles, left on

{

India Book Rd. (30) for.9 miles to the j;

S.C. Wildlife Resources Dept. on left (TLD

)l CNS #236).

l!

C1 4

3 Rwy. 274-5 for 3.8 miles, left on Mt.

Gallant Rd. (195) for 3 miles, right on 1

Homestead Rd. (657) for 2.5 miles to end of road. TLD is straight across at intersection of Twin Lakes Rd. (TLD CNS

.s

  1. 237).

,-----,..n

,n

--n.--

.,, _ -.. - -,. -,,, - - - ~., -...

-,,-.n

k.

Page 6 of 9 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS AIR SAMPLE LOCATIONS (NEED XEY, CPD-1) 0 ZONE & RADIUS (Mi)

No.

DESCRIPTION i i C1 4

5 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 1.3 miles, right on West Oak Dr. (962) for 1.2 miles to end at fork. TLD on left at fence. (TLD CNS #238).

C2 7

3 Hwy. 274-S for 9.2 miles, right on Berlong Ave. for.3 miles to Piedmont Medical Center emergency entrance to back of hospital. TLD on fence at back right 4

corner of Liquid Oxygen storage area (TLD CNS #248).

- l C2 8

6

' Hwy. 274-S for 5.1 miles, left on Hwy.161

, ~ ~

for 1.3 miles, right on Rawlinson R&--(56) for 1.8 miles, left on Hwy. 5 for.5 miles to Rock Hill Career Development Center on i'

right. TLD on transmission tower in front of building (TLD CNS #249).

l; C2 10 5

Hwy. 274-5 for 5.1 miles, left on Hwy.161 i }

for 1.3 miles, right on Rawlinson Rd. (56) v for 1.8 miles, left on Hwy. 5 for 1.6 4

i miles, right on Heckle Blvd. (901) for 3.3 miles to end of road, left on Hwy. 72 for 4.

1.2 miles, right on dirt road across from Wayne's Auto Service. Go.1 miles to Duke 1-Power Company substation on left (TLD & Air CNS #217, need key).

l ;!

D1 4

2 Hwy. 274-5 for 1.2 miles', right on Campbell Rd. (80) for 2.3 miles, left on.

D1 5

1 Hwy. 274-5 for 5 miles N Carter Lumber i

Co.

TLD on fence near gate (TLD CNS #239).

1.

e J

,n.

e

--e-

-,w~

,...,,,.-w

---n-,.,-----e,,,

Page 7 of 9 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 il f

AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS J:

l AIR SAMPLE LOCATIONS (NEED XEY, CPD-1)

It

]I ZONE & RADIUS (Mi)

No.

DESCRIPTION l'f!

D1 5

4 Hwy. 274-5 for 1.2 miles, right on Campbell Rd. (30) for 3 miles. TLD on left at j,'

beginning of fence (TLD CNS #241).

l.

D2 10 4

Hwy. 274-5 for 1.2 miles, right on Campbell l

Rd. (30) for 3.4 miles, left on Hwy. 49-S for 5.2 miles, left on North Congress St.

(64) for.7 miles, left on Hwy. 5 for.2 j

miles to Duke Power Company Appliance Center on left. TLD on fence in back (TLD

'i CNS #250).

j i

i El 5

2 Hwy. 49-S for 3 miles, right on Parsban Rd.

j' (54) for.7 miles to transmission tower on left after bridge (TLD CNS #242). "

)l C

El 5

3 Hwy. 274-N for 2.1 miles, left on Hwy. 55 h

for 2.3 miles, left on Kingsburry Rd. (114) for.4 miles to transmission tower on left j

(TLD CNS #243).

1!

i H

E2 10 2

Hwy. 274-N for 2.1 miles, left on Hwy. 55 g

for 7.4 miles to Duke Power Company Appliance Center on left. TLD on fence in j

back of building (TLD CNS #251).

1:

F1 4

1 Hwy. 274-N for 2.1 miles, left on Hwy. 55 for 1.5 miles to Bethel School. TLD on i,

side of small building in back (TLD CNS

  1. 244).

o 4

F1 4

3 Hwy. 274-N for 3.4 miles, left on Glenvista Rd. to Crowders Creek boat landing. TLD to east of parking lot (TLD CNS #245).

t

)

!}

.i

_-.y e

i Page 3 of 9

~

DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 AIR SAMPLER, TLD, AND WATER SAMPLE LOCATIONS AIR SAMPLE LOCATIONS (NEED KEY, CPD-1) i ZONE & RADIUS (Mi)

No.

DESCRIPTION l

F1 4

4 Nwy. 274-N for 3.1 miles to River Hills Plantation rear entrance at Hamilton's l

Terry Rd. TLD b,ehind green building on right corner (TLD CNS #230).

F1 4

6 Hwy. 49-N for 4.1 miles to River Hills Plantation entrance guardhouse (TLD CNS

  1. 231).

A0 1

46 Left exiting Steam Production entrance on Concord Rd. for.7 miles. Turn left just after canal bridge. Go to pier (Water CNS*

  1. 208, need key).

A1 4

6 Ewy. 49-N for 5.6 miles, left at Camp Steere sign after crossing Buster Boyd Bridge for.7 miles to end of road (Water CNS #215).

B1 4

5 Ewy. 49-N for 8 miles, right on Rwy.160 for 3.9 miles, right on Dan Rd. (99) for

}

1.6 miles, left on Gray Rock Rd. (251) for

.7 miles to Lake Wylie Dam. Walk through plant to upstress side of the das (Water a

CNS #211).

31 4

6 Hwy. 49-N for 8 miles, right on Hwy. 160 for 3.9 miles, right on Das Rd. (99) for 1.6 miles, left on Gray Rock Rd. (251) for

.7 miles to Lake Wylie Dam. Go to river access on downstress side of dam.

I B2 7

6 Nwy. 49-N for 8 miles, right on Ewy.160 for 7.1 miles, right on Lee St. for.1 miles, left on Self St. for approxiestely 100 yds. TLD at Fort Mill Municipal Water Supply on right behind Springs Mill (TLD CNS #247, Water CNS #213).

l 1

Page 9 of 9 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.1 AIR SAMPLER, TLD, AND WATER SAhPLE LOCATIONS 4

AIR SAMPLE LOCATIONS (NEED KEY, CPD-1)

ZONE & RADIUS (Mi)

No.

DESCRIPTION 9

C2 7

2 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 8.5 miles to the intersection of, Cherry Rd.

Go to Rock Hill o

Municipal Water Supply across intersection on left (Water CNS #214).

C2 7

8 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 7.6 miles, left on Hwy.161 for 1.1 miles, left on Hwy. 21 for

)

.4 miles, left on Grier McGuire Rd. for.5 siles to end of road.

F3 14 4

Hwy. 274-N for 5 miles, right on Pole Branch Rd. (279) for 2.8 miles, right.on, l

Hwy. 273 for 7.2 miles into Belmont, right on Catawba St. for.6 miles, left at next light for.2 miles to Belmont Municipal i

Water Supply (Water CNS #218).

l 4

l 1

.i.

T

.i

--,w,--...w

---<n

, - - - ~,

- - - - -, ~ - -,. -. - -, -,. - -

e

Page 1 of 1 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.2 MILK SAMPLE LOCATIONS 4:

ZONE & RADIUS (Mi)

MILK DESCRIPTION j

y D1 6

M Hwy. 274-S for 5.1 miles, right on Hwy.161 for 2.1 miles, left on Rd.1080 for.5 miles to Pursley Dairy.

D2 3

M Hwy. 274-S for 5.1 miles, right on Hwy.161 for 4.7 miles, left at Scise Dairy and Equipment Co. (CASE sign).

E2 6

M Hwy. 274-N for 2*.1 miles, left on Hwy. 55 for 3.3 miles, left on Clinton Dairy Rd. to end of road.

F1 3

M Hwy. 274-N for 2.2 miles, right on Lake Wylie Rd. (1099) for.1 miles to first house on left (Ingram Richmond residence).

F2 7

M Hwy. 274-N for 2.1 miles, left on Hwy. 55 for 3 miles, right on Paraham Rd. (54) for.

1.5 miles, left on Hwy. 557 for 1 mile.

]

Barnett Dairy on left.

D1 7

M Hwy. 274-S for 5.1 miles, left on Hwy.161 for.1 miles, right on Adnah Church Rd.

(81) for 1.4 miles. Woods Dairy is on the 4

left.

F2 13 M

Hwy. 274-N for 2.1 miles, left on Hwy. 55 i

for 9.5 miles through Clover, S.C., right on Lloyd White Rd. (144) for 2.3 miles,

l' left on Crowders Creek Rd. (1103) for 1.3 ailes, right on Sparrow Springs Rd. (1125) for.5 miles. Cates Dairy is on the left.

Y I

I_

i 4

\\

l l

1

\\

x.

Page 1 of 13 DUKE POWER COMPANY s

l CATAWBA NUCLEAR STATION HP/,0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION A0 1

1 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, right at fork for 1.1 miles to end of road (TLD & Air CNS # 200, need key).

l A0 1

2 Hwy. 274-N for 2.2 miles, right on Lake Wylie Rd. (1099) for 2.2 miles to fork in road, right at fork onto Commodore Pl. for

.2 miles, left o*n Tioga Rd. for.3 miles to end of rosj.

A0 2

3 Hwy. 274-N for 2.2 miles, right on, Lake Wylie Rd. (1099) for 2.2 miles to fork in road where pavement ends.

A0 2

4 Hwy. 49-N for 6.5 miles, right on Pleasant Mill Rd. (1109) for.5 miles, right on l

Youngblood Rd. (1102) for 3 miles to fork in road, left at fork for.6 miles to end I

at Catarba Yacht Club.

I A0 1

5 Left exiting Steam Production entraTcE o'n Concord Rd. for 1.2 miles, left on Old Concord Rd. for.3 miles, right on Acacia l

Rd. for.3 miles, left on Crepe Myrtle Rd.

for,.7 miles, left on Blue Bird In. for.1

]

miles to end (TLD & Air CNS #201, need key).

~

A0 1

6 Ewy. 49-N for 6.5 miles, right on Pleasant Rill Rd. (1109) for.5 miles, right on Youngblood Rd. (1102) for 2.8 miles, left i

on Snus Harbor Rd. (1357) for.5 miles, i

right on Ealabash Rd. for.3 miles, right on Cozy Cove Rd. (1434) for.5 miles to end.

A0 2

7 Evy. 49-N for 6.5 miles, right on Pleasant I

Bill Rd. (1109) for.5 miles, right on Youngblood Rd. (1102) for 2.8 miles to the

)

intersection of Snug Harbor Rd. (1357).

A0 1

Left exiting Steam Productica entrance on Concord Rd. for 1.2 miles, left on old Concord Rd. for.3 miles, right on Acacia

)

a Rd. for.3 miles, left on Crepe Myrtle Rd.

Go.?,siles to first drive on right past i

Paradise Pl., TLD across road (TLD CNS

  1. 202).

j A0 1

9 Hwy. 49-N for 6.5 miles, right on Pleasant Nill Rd. (1109) for.5 miles.

1

~

i

~.., - 1

s Page 2 of 13

^

DUKE POWER COMPANY I'

CATAWBA NUCLEAR STATION HP/0/B/1009/04 p

ENCLOSURE 5.3 i

PREDETERMINED SAMPLING LOCATIONS a

f ZONE & RADIUS (Mi)

No.

DESCRIPTION f

right on Youngblood Rd. (1102) for 2.3 miles, left on Snug Harbor Rd. (1357) for i

1.3 miles to end of road.

5 A0 2

10 Hwy. 49-N for 6.5 miles, right on Pleasant Hill Rd. (1109) for.5 miles, right on C

9 Youngblood Rd. (1102) for 2.3 miles, left on Snus Harbor Rd. (1357) for 1.3 elles, isit on Crosshavens Dr for.3 miles to end

[

of road.

4 l

A0 1

11 Left exiting Steae Productica entrance on Concord Rd. for 1.2 miles, left on Old concord Rd. for.3 miles, right on Acacia Rd. for.3 miles, lef t on Crepe Myrtle Rd.

for.2 miles. TLD is on left-in curve (TLD CNS #223).

A0 1

12 Hwy. 49-N for 6.5 miles, right on Pleasant *

\\

Rill Rd. (1109) for.5 miles, right on Youngblood Rd. (1102) for 1.6 miles,,Jg.ft on McKee Rd. (1100) for 1.2 miles, right on l

Bankhead Rd. for 1.2 miles to end of road.

i A0 2

13 Hwy. 49-N for 6.5 miles, right on Pleasant l

Hill Rd. (1109) for.5 miles, right on L

Youngblood Rd. (1102) for 1.6 miles, left on McKee Rd. (1100) for 1.2 miles, right on Bankhead Rd. for.4 miles to the i

h intersection of Bessbrook Rd.

A0 1

14 Left exiting Steam Production entrance on l

Concord Rd. for 1.2 miles, left on Old Concord Rd. for.3 miles, right on Acacia Rd. for.2 miles. TLD is on right side of I

road (TLD CNS #224).

p A0 1

15 Left exiting Steam Production entrance on F

Concord Rd. for 1.3 miles, left on

[

Kingfisher Dr. for 1.8 miles to Commodore Yacht Club.

l A0 1

16 Left emiting Steam Production entrance on Concord Rd. for 1.3 miles where pavement ends.

i l

A0 1

17 Left exiting Steam Production entrance on Concord Rd. for 1.1 miles to first

[

transmission tower on left after bridge (TLD CNS #225).

--. -.-...---. -...l

.-..=. -

~

Page 3 of 13 x__

DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION A0 1

18 Left exiting Steam Production entrance on Concord Rd. for 1 7 miles, right on Sandlapper Rd. for.2 miles. Stop at transmission tower.

A0 2

19 Hwy. 274-S for 1.6 miles, left on Alliaon Creek Rd. (1081) for 3 miles to end of pavement.

A0 1

20 Left exiting Steam Production entrance on Concord Rd. for.7 miles. TLD on lef t just past fence (TLD CNS f226).

A0 1

21 Hwy. 274-S for 1.6 miles, left on Allison.

Creek Rd. (1081) for 1.7 miles, left on Spratt Rd. to end.

(Beware of dogs).

A0 2

22 Hwy. 274-S for 1.6 miles, left on Allison ;

Creek Rd. (1081) for 1.6 miles to intersection of Bardale Rd.

A0 1

23 Left exiting Steam Production entrance on Concord Rd. for.4 miles. TLD on left at beginning of guardrail posts (TLD CNS #204).

A0 1

24 Hwy. 274-S for 1.6 miles, left=on Allison Creek Rd. (1081) for 1.7 miles, left at Spratt Rd. for.1 miles, lef t on Morrison Rd., right at first 2 forks then left at next fork to end for a total of.5 miles.

A0 2

25 Hwy. 274-S for 1.6 miles, left on Allison Creek Rd. (1081) for 1.7 miles to intersection of Spratt Rd.

A0 1

26 Location at the base of Catawba Nuclear 1

l Station Meterological Tower (TLD & Air CNS

  1. 205, need key).

A0 1

27 Right exiting Steam Production entrance on

~

Concord Rd. for.1 miles, left on Valelake Rd. for.1 miles to fork in road, left at fork for.5 miles to end of road.

A0 2

28 Hwy. 274-S for 1.6 miles, left on Allison Creek Rd. (1081) for 1 mile to intersection of Colina Rd.

A

Page 4 of 13 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION A0 1

29 Left exiting Steam Production entrance on Concord Rd. for.1 miles. TLD at Shady Shore Dr. on right corner of Bethel Comnuaity Clubhouse sign (TLD CNS #227).

AD 1

30 Right exiting Steam Production entrance on Concord Rd. for.1 miles, left on Valelake Rd. for.1 miles to fork in road, right at fork for.5 miles to end of road.

A0 2

31 Hwy. 274-S for 1.2 miles to the intersection of Campbell Rd. (80).

A0 1

32 Right exiting Steam Production entrance on Concord Rd. for.1 miles. TLD is on right side of entrance to Valelake Rd. (TLD CNS

  1. 228).

A0 1

33 Right exiting Steam Production entrance on i Concord Rd. for 1 mile, left on Pine Point i

Dr. for.5 miles.

A0 2

34 Hwy. 274-S for.7 miles to Big Allison Creek Bridge.

A0 1

35 Right exiting Steam Production entrance on Concord Rd. for.4 miles. TLD on top of hill on right at the intersection of Catawba Nuclear Station Construction entrance (TLD CNS #206).

A0 1

36 Right exiting Steam Production entrance on Concord Rd. for.9 miles. Stop at entrance to transmission lines.

A0 2

37 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.3 miles, left on Fremont Rd.

for.2 miles to end of road.

A0 1

38 Go through Construction Maintenance Dept.

(Central) Main Gate for approximately 50 ft., left on Alternate 1 for approximately 200 ft. to stop sign, left on gravel road for.1 miles, left into rebar yard for.7 miles on gravel road to end at chain link i

fence. Follow chain link fence in a northerly directica for approximately 300 yards. TLD is hanging on fence (TLD CNS

  1. 229).

l 9

~.

Page 5 of 13

+

DUKE POWER COMPANY CATAWBA NUCLEAR STATION i

HP/0/B/1009/04

{

ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION A0 1

39 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, right at fork for.3 miles to third transmission tower on right.

U A0 2

40 Right exiting Steam Production entrance on Concord Rd. for 1.3 miles, right on Hwy.

274-N for 1 mile.

A0 1

41 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, right at fork for.4 miles. TLD on fence on right (TLD CNS #207).

A0 1

42 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, right at fork for.8 miles to softball field entrance.

e A0 2

43 Hwy. 274-N for 2.2 miles, right on Lake Wylie Rd. (1099) for 1.9 miles, right on Beaver Creek Trail for.3 miles to"end'o'f road.

A0 1

44 Hwy. 274-N for.5 miles, right on Liberty Hill Rd. for.4 miles to fork in road, right at fork for 1 mile to large rock pile at fence. TLD is on fence (TLD CNS #222).

A0 1

45 Left exiting Steam Production entrance on Concord Rd. for 1.2 miles, left on Old Concord Rd. for 1.4 miles to end of road.

TLD is on fence on the left side (TLD CNS

  1. 203).

A0 1

46 Left exiting Steam Production entrance on Concord Rd. for.7 miles. Turn left just after canal bridge. Go to pier (Water CNS

  1. 208, need key).

A1 3

1 Hwy. 49-N for 4.8 miles to the N.C. side of Buster Boyd Bridge.

A1 4

2 Hwy. 49-N for 6.5 miles to the intersection of Pleasant Hill Rd. (1109). TLD is on the trancaission tower on left (TLD CNS #232).

Page 6 of 13 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS

.ZO,hE & RADIUS (Mi)

No.

DESCRIPTION A1 5

3 Hwy. 49-N for 7.8 miles to Steele Creek Volunteer Fire Department on right.

A1 4

4 Hwy. 49-N for 6.5 miles, right on Pleasant Hill Rd. (1109) for.5 miles, right on Youngblood Rd. (1102) for.6 miles, lef t on Zoar Rd. (1105) for.4 miles, right on Thomas Rd. (1104) for.1 miles. TLD is l

behind second house on right in pines (TLD CNS #233).

A1 5

5 Hwy. 49-N for 6.5 miles, right on Pleasant Hill Rd. (1109) for.5 miles, right on Youngblood Rd. (1102) for.3 miles, left on Hamilton Rd. (1106) for.7 miles to the intersection of Hwy. 160.,

A1 4

6 Hwy. 49-N for 5.6 miles, left at Camp g

Steere sign after crossing Buster Boyd

(

Bridge for.7 miles to end of road (Water CNS #215).

A2 10 1

Hwy. 49-N for 11.4 miles to Westinghouse

' Blvd. Go 1 mile past Westinghouse Blvd. to Roberts Systems 8500 on left.

A3 10 1

Hwy. 49-N for 10 miles, right on Carowinds Blvd. (1441) for 3 miles, left on Hwy. 51 for 2.1 miles to Sugar Creek Bridge.

B1 3

1

. Ewy. 49-N for 8. miles, right on Hwy.160 for 2.8 miles, right on Gold Hill Rd. (98) at Tega Cay sign for 1.2 miles, right on gravel road into Duke Power Company substation (TLD & Air CNS #212, need key).

B1 2

2 Hwy. 49-N for 6.5 miles, right on Pleasant Hill Rd. (1109) for.5 miles, right on Youngblood Rd. (1102) for 1.6 miles, left.

on McKee Rd. (1100) for 1.2 miles, left on Bankhead Rd. for.4 miles, left on Bessbrook Rd. for.8 miles to end of road.

i

l Page 7 of 13 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION 1

B1 4

3 Hwy. 49-N for 8 miles, right on Hwy. 160 for 3.9 miles, right on Das Rd. (99) for 1.9 miles to last gravel road on right in sharp curve before Lake Wylie Dam, left through fence for.2 miles to substation.

TLD on right of inner substation (TLD CNS

  1. 235).

B1 2

4 Hwy. 49-N for 8. miles, right on Hwy. 160 for 2.8 miles, right on Cald Hill Rd. (98) at Tega Cay sign. Enter Tega Cay following Tega Cay Dr. for 2.6 miles, right on Windjammer Dr. for.6 miles to circle, right at circle for.2 miles, left on Kiwi Point for.2 miles to end of road, f

B1 4

5 Hwy. 49-N for 8 miles, right on Hwy. 160 for.3.9 miles, right on Das Rd. (99) for 1.6 miles, left on Gray Rock Rd. (251) for *

.7 miles to Lake Wylie Dam. Walk through plant to upstreas side of the das (Water CNS #211).

B1 4

6 Hwy. 49-N for 8 miles, right on Hwy. 160

~

for 3.9 miles, right on Das Rd. (99) for 1.6 miles, left on Gray Rock Rd. (251) for

.7 miles to Lake Wylie Dam. Go.to river access on downstress side of das.

B2 8

1 Hwy. 49-N for 10 miles, right on Carowinds Blvd. (1441) for 1.3 miles, left on Choate Cire.le for.3 miles. TLD is on the inside of fence left of the guardhouse (TLD CNS

  1. 246).

B2 4

2 Hwy. 49-N for 8 miles, right on Hwy. 160 for 2.8 miles to the Home Federal Savings and Loan on left side of road. TLD on barbed wire fence approximately 50 yds.

behind bank (TLD CNS #234).

B2 5

3 Hwy. 49-N for 8 miles, right on Hwy.160 for 2.8 miles, left on Gold Hill Rd. (98) for 1 mile, stop at the intersection of s

Whitley Rd.

g 7 m-%--

-w,.

,,, -,. +, - -, - -

g,--

yo,,-

,rn.,,,--,,,_,-----,,w--

w.-

Page 8 of 13 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 E!. CLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION B2 10 4

Hwy. 49-N for 10 miles, right on Carowinds

^;'

Blvd. (1441) for 3 miles, left on Hwy. 51 for 3 miles, right on Hwy. 521 (Polk St.)

for 2.9 miles, right on Dorman Rd. for 1.1 miles, stop at the state line.

F B2 5

5 Hwy. 49-N for 8 miles, right on Hwy.160 for 5.6 miles, right on Sutton Rd. (49) for 1.1 miles to the intersection of Gray Rock Rd. (251).

B2 7

6 Hwy. 49-N for 8 miles, right on Hwy. 160 for 7.1 miles, right on Lee St. for.1 miles, left on Self St.. for approximately 100 yds. TLD at Fort Mill Municipal Water Supply on right behind Springs Mill (TLD CNS #247, Water CNS #213).

B2 10 7

Hwy. 49-N for 8 miles, right on Hwy.160

(

)

for 10 miles through Fort Mill to the Sugar Creek Bridge.

b 1

C1 4

1 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 5.2 miles, left on" India Hook Rd. (30) for.9 miles to the S.C. Wildlife Resources Dept. on left (TLD CNS #236).

C1 5

2 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 5.6 miles to Red Burketts Body Shop on right.

C1 4

3 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 3 miles, right on Homestead Rd. (657) for 2.5 miles to end of a

road. TLD is straight across at intersection of Twin Lake Rd. (TLD CNS q

  1. 237).

l C1 5

4 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 3 miles, right on Homestead Rd. (657) for 2.5 miles to end of road.

C1 4

5 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 1.3 miles, right on West Oak Dr. (962) for 1.2 miles to end at fork. TLD on left at fence (TLD CNS #238).

---,e, 4-,-.

-,---.,--,,,.-,,-,w,

,.,,e.-,,,

p,,.,

e---.

-,e w--

-p,~

q g-g o,,

.--e--,

p

9 Page 9 of 13 DUKE POWER COMPANY CATAWBA NUCLEAR STATION KP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)-

No.

DESCRIPTION C1 5

6 Hwy. 274-S for 5.1 miles, left on Hwy.161 for 2.2 miles to fork in road, left at fork for.1 miles, S.C. National Guard Armory on left side of road.

C1 5

7 Hwy. 274-S for 5 miles to Carter Lumber Company.

C2 10 1

Hwy. 274-S for 5.1 miles, left on Hwy.161 for 2.2 miles to fork in road, left at fork on Celanese Rd. (50) for 8.2 miles to the intersection of Springdale Rd.

C2 7

2 Hwy. 274-S f'or 3.8 miles, left on Mt.

Gallant Rd. (195) for 8.5 miles to the,

intersection of Cherry Rd.

Go to R'ck Hill Municipal Water Supply across intersection.

on left (Water CNS #214).

/

C2 7

3 Hwy. 274-S for 9.2 miles, right on Berlong Ave. for.3 miles to Piedmont Medical Center emergency entrance to back of j

hospital. TLD on fence at back right corner of Liquid Oxygen storage area (TLD CNS #248).

C2 10 4

Hwy. 274-S for 5.1 miles, left on Hwy.161 for 5.7 miles, right on Mt. Gallant Rd.

(195) for 1.5 miles, right on Hwy.21-121 Bypass for 2 miles to the Fast Fare on left at the intersection of Springsteen Rd.

C2 10 5

Hwy. 274-S for 5.1 miles, left on Hwy.161 for 1.3 miles, right on Rawlinson Rd. (56) for 1.8 miles, left on Hwy. 5 for 1.6 miles, right on Heckle Blvd. (901) for 3.3 miles to end of road, left on Rwy. 72 for 1.2 miles, right on dirt road across from Wayne's Auto Service. Go.1 miles to Duke Power Company substation on'left (TLD & Air CNS #217, need key).

C2 8

6 Hwy. 274-S for 5.1 miles, left on Hwy.161 for 1.3 miles, right on Rawlinson Rd. (56) for 1.8 miles, left on Hwy. 5 for.5 miles to Rock Hill Career Development Center on right. TLD on transmission tower in front of building (TLD CNS #249).

.s s.

Page 10 of 13 DUKE POWER COMPAFY CATAWBA NUCLEAR STATION i.

HP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION C2 10 7

Hwy. 274-S for 5.1 miles, left on Hwy. 161 for.1 miles, right on Adnah Church Rd.

(81) for 2.9 miles, right on Hwy. 5 for.2 miles, left on Eastview Rd. (102) for 3.2 miles, right on Hwy. 322 for.1 miles, left j

on Falls Rd. for.9 miles to the intersection of Oak Park Rd. (103).

C2 7

8 Hwy. 274-S for 3.8 miles, left on Mt.

Gallant Rd. (195) for 7.6 miles, left on Hwy. 161 for 1.1 miles, left on Hwy. 21 for

.4 miles, left on Grier McGuire Rd. for.5 miles to end of road.

Hwy. 274-S for 5 ' miles to Carter Lumber D1 5

1 Company. TLD on fence near gate (TLD CNS

  1. 239).

(

' D1 4

2 Hwy. 274-S for 1.2 miles, right on Campbell 1

1 V

Rd. (80) for 2.3 miles, left on Paraham..Rd..

(54) for 1.5 miles to transmission tower on right. TLD on power pole (TLD CNS #240).

l D1 5

3 Hwy. 274-S for 1.2 miles, right on Campbell l

Rd. (80) for 2.3 miles, left on Paraham Rd.

(54) for.6 miles, right on Harper Rd.

1 (815) for 1.4 miles to Allison Creek Bridge.

D1 5

4 Hwy. 274-S for 1.2 miles, right on Campbell Rd. (80) for 3 miles. TLD on left at beginning of fence (TLD CNS #241).

D2 10 1

Hwy. 274-S for 5.1 miles, left on Hwy. 161 for.1 miles, right on Adnah Church Rd.

(81) for 2.9 miles, right on Hwy. 5 for.2 miles, left on Eastview Rd. (102) for 1 mile, right on Holland Rd. (157) for.7 siles, right on Turkey Farm Rd. (1172) for 1.2 miles, left on Russell Rd. (536) for.2 miles.

~

~

v

~

we.. -

,m,, - - -

-w,.r-r4 m.-, - - -

w,--e

,m, y


w-n-

l Page 11 of 13 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION D2 10 2

Hwy. 274-S for 5.1 miles, left on Hwy. 161 for.1 miles, right on Adnah Church Rd.

(81) for 2.9 miles, right on Hwy. 5 for.3 siles, left on Billy Wilson Rd. (1451) for l

2.2 miles, right on Turkey Fars Rd. (1172) for.8 miles, left on Benfield Rd. for.3 miles to Fishing Creek Bridge.

D2 10 3

Hwy. 274-S for 1*.2 miles, right on Campbell Rd. (80) for 3.4 miles, left on Hwy. 49-S for 5 miles. Stop at Pantry on left.

D2 10 4

Hwy. 274-S for 1.2 miles, right on Campbell Rd. (80) for 3.4 miles, left on Hwy. 49-S for 5.2 miles, left on North Congress St.

(64) for.7 miles,, left on Hwy. 5 for.2

)

ailes to Duke Power Company Appliance l

Center on left. TLD on fence in back (TLD.*

CNS #250).

P x-D2 10 5

Hwy. 274-S for 1.2 miles, right on,C,ampbell Rd. (80) for 3.4 miles, left on Hwy. 49-S

.i for 1.7 miles, right on Old Limestone Rd.

(172) for 4.3 miles to end of road.

El 5

1 Hwy. 274-S for 1.2 miles, right'on Campbell Rd. (80) for 3.4 miles to the intersection of Hwy. 49.

El 5

2 Hwy. 49-S for 3 miles, right on Paraham Rd.

)

(54) for.7 miles to transmission tower on I

left after bridge (TLD CNS #242).

El 5

3 Hwy. 274-N for 2'.1 miles, left on Hwy. 55 for 2.3 miles, left on Kingsburry Rd. (114) for.4 miles to transmission tower on left (TLD CNS #243).

l El 5

4 Hwy. 274-N for 2.1 miles, left on Hwy. 55 for 2.3 miles to the intersection of Kingsburry Rd. (114).

E2 5

1 Hwy. 274-S for 1.2 miles, right on Campbell Rd. (80) for 2.3 miles, right on Paraham Rd. (54) for.9 miles to the intersection of Dr. Nichols Rd. (819).

i

,._..y,-.

-,_.._,m_

...,..._w..

...~,,x-._.-

..,,,, ___. ~,,,

Page 12 of 13 DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.3 PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

No.

DESCRIPTION j

E2 10 2

Hwy. 274-N for 2.1 miles, left on Hwy. 55 for 7.4 miles to Duke Power Company Appliance Center on left. TLD on fence in back of building (TLD CNS #251).

E2 10 3

Hwy. 274-N for 2.1 miles, left on Hwy. 55 for 7.3 miles to the Pantry on left at the intersection of, Hwy. 321 (behind Pantry).

F1 4

1 Hwy. 274-N for 2.1 miles, left on Hwy. 55 for 1.5 miles to Bethel School. TLD on side of small building in back (TLD CNS #244).

F1 5

2 Hwy. 274-N for 2.1 miles, left on Hwy. 55 for 1.5. miles, right on Bethel School Rd.

(152) for 1 mile to the intersection of Holland Dr.

1 f

F1 4

3 Hwy. 274-N for 3.4 miles, left on Glenvista Rd. to Crowders Creek boat landing. _113 to east of parking lot (TLD CNS #245).

11 4

4 Hwy. 274-N for 3.1 miles to River Hills Plantation rear entrance at Hamilton's Ferry Rd. TLD behind green building on I

right corner (TLD CNS #230).

F1 5

5 Hwy. 49-N for 2.9 miles to Sherer Memorial Presbyterian Church parking lot on left.

F1 4

6 Hwy. 49-N for 4.1 miles to River Hills Plantation entrance guardhouse (TLD CNS

  1. 231).

F1 5

7 Hwy. 49-N for 3.6 miles, left on Montgomery Rd. for 1 mile. Stop in horseshoe curve near lake.

72 10 1

Hwy. 274-N for 4.2 miles, left on Hwy. 557 for 2.2 miles, right on Ridge Rd. (27) for 5 miles to Bowling Green Presbyterian Church.

F2 5

2 Hwy. 274-N for 4.2 miles, left on Hwy. 557 for.6 miles to Pine Grove Baptist Church.

L i

- ~..

-,,,,.,n wn.-,

..-.,,n.-

Page 13 of 13 DUKE POWER COMPANY CATAWBA NUCI. EAR STATION HP/0/B/1009/04 ENCIDSURE 5.3

~ PREDETERMINED SAMPLING LOCATIONS ZONE & RADIUS (Mi)

N DESCRIPTION

~

a F3 10 1

Hwy. 274-N for 4.2 miles, left on Hwy. 557 for.9 miles, right on Oakridge Rd. (435) at Bethel Fire Dept. for 5.4 miles to the intersection of Hwy. 274 (in N.C.)

F3 10 2

Hwy. 274-N for 5 miles, right on Pole Branch Rd. (279) for 5.8 miles to Friendship Baptist Church on left.

F3 10 3

Hwy. 274-N for 5 miles, right on Pole Branch Rd. (279) for 2.8 miles, right on Hwy. 273 for 3 miles to Allen Steam Plant Bridge.

1 F3-14 4

Hwy. 274-N for 5 miles, right on'? ole Branch Rd. (279) for 2.8 miles, right on Hwy. 273 for 7.2 miles into Belmont, right on Catawba St. for.6 miles, left at next light for.2 miles to Belmont Municipal Water Supply (Water CNS #218).

e.egpese* &*e

>}

l p

y i=w---

m,,

,v

-wy y

+--

w--

e wy-,.-

e e

9 e

e e

t e

i 18$

Y I-s;=

g_

l$

g A

alg I

3

=

i t

5

. lll i.

e

~

I 1 GI I

3 N

3 I

j:

Ia e

9 n.,

1 l

l Pegs 1 of 1 l

DUKE POWER COMPnNY CATAWBA NUCI. EAR STATION HP/0/B/1009/04 ENCLOSURE 5.5 FIEI.D MONITORING DATA SHEET Date Team Members / Call Sign

/

Inst. Type /No.

/

Seear Sample Location Time Survey Taken Dose Rate (aR/hr)

Activity (CCPM)

J t e

Y 4

/

\\ _,,

-- s.

e

4

-n t

4 9

4

'1

-e g-g-W-,,eq+-a,g

s. %um,qw y.%%e-re,awg.m w e%rw--.e.we-.,wre.+,--wwr-..m-,cw-re---s&,wy-y-a-v me.,

e r eew w m.+www y

g pg.

---*--rr- - + =

-w~

-vyw

+ee--

l i

)

Page 1 of I l

J DUKE POWER COMPANY CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.6 SAMPLE TIME REQUIRED FOR MINIMUM SAMPLE VOLUME FLOW RATE

. MINIMUM REQUIRED SAMPLING TIME IN MINUIES CFM LPM

.5

=

14.................

71 1.0 =

28.................

36 1.5 =

42.................

24 2.0 =

56.................

18 2.5 =

70.................

15 3.0 = 84..................*12 3.5 =

99.................

11 4.0 = 113.................. 9 4.5 = 127.................. 8

~

i'

.-w.

NOTE:

When estimating time required to get a minimum volume of 1 x 108 al if flow rate for the air sampler in use is not on table, so to next Lower flow rate. The, LPH are rounded off to the conservative side.

Example: Air Sampler flow rata = 106 LPM. Minimum time 11 minutes 1

l l

l l

DUKE POWER COMPANY Page 1 of 2 CATAWBA NCUIIAR STATION

'HP/0/B/1009/04 ENCLOSURE 5.7 FIELD MONITORING TEAM WORK SHEET FOR DETERMINING IODINE ACTIVITY Team Members Date Air Sampler No.

Team Call Sign Canberra No.

AIR SAMPLE INFORMATION ANALYSIS RESULTS A

B C

D E

F Sample ID.

Air Sampler Flow Rate Iodine Activity Dose Rate

.Results No./ Time / Location Run Time (Min)

(LPM)

Microcuries/al meen/hr Reported By:

/

/

/

/

/

/

/

/

/

/

/

/

/

/

t

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

Column A) Number of Sample / Time it was Taken/ Sampling Location (ex. A0-2-10).

Coluna B) Length of time the air sampler ran.

Coluna C) Air sampler meter flow rate.

Column D) Activity from Canberra.

Column E) Dose rate from Canberra, aluma F) Signature of person that calls in results to FMC.

ywn-w v.---

---v.--,-~..-

v-

<w

DUKE POWER COMPANY Page 2 of 2 CATAWBA NUCLEAR STATION HP/0/B/1009/04 ENCLOSURE 5.7 OPERATOR GUIDELINES 5.6.1 MCA and Detector Set-Up 5.6.1.1 Disconnect DC power cord from unit.

5.6.1.2 Turn the contrast switch on the front of the unit clockwise to the ON mode.

5.6.1.3 Place sample holder with Na-22 check source onto the detector.

5.6.1.4 Press TEST SYSTEM.

5.6.1.5 Press ENTER to begin test.

5.6.1.6 If test failed, press CLEAR ENTRY and remove the instrument from service.

5.6.1.7 If test passed, press ElffER.

5.6.2 Collecting and Measuring Filter Cartridges NOTE:

Record data on Field Monitoring Team Work Sheet for Determining Iodine Activity (Sample Enclosure 5.6).

5.6.2.1 Press ANALYZE FILTER SAMPLE.

5.6.2.2 Press ENTER.

5.6.2.3 For each sample:

5.6.2.3.1 Place cartridge with the recognizable side toward the detector (in small poly bas) in sample holder.

5.6.2.3.2 Put Jetector and sample holder in shield.

5.6.2.3.3 Press INTER to accept ID number.

5.6.2.3.4 Press INTER to accept current Flow Rate (LPM).

Otherwise, change number and press ENTER.

5.6.2.3.5 Press ENTER to accept current Flow Time (min).

Otherwise, change number and press ElfrER.

i 5.6.2.3.6 If the volume is determined to be too small, resample, press INTER and return to Step 5.6.2.3.

5.6.2.3.7 Press ENTER to start Collect / Analyze.

5.6.2.3.8 Report / Record Iodine activity (pci/al) and dose rate (area /hr).

5.6.2.3.9 Press NEXT SAMPLE.

5.6.2.3.10 Label the cartridge and retain for later analysis.

I 5.6.3 After sampling completion, turn the contract switch counter-clockwise to the STAND-BY mode.

i I

Page 1 of 1 DUKE POWER COMPANY CATAWBA NUCLEAR STATION

.HP/0/B/1009/04 ENCLOSURE 5.8 TSC FIELD MONITORING ORGANIZATION POSITION NAME BUSINESS PHONE HOME PHONE Field Monitoring Coordinators:

Primary:

C. V. Wray Alternates:

R. E. DeShazo J. E. Threatt TSC Radio Operators:

Primary:

D. E. Sexton Alternate:

P. W. Sturgis Field Monitoring Teams:

All Health Physics personnel with Field Monitoring Training.

s v

O e

e 1

+

e g

e g

1 Page 1 of 1 DUKE POWER COMPANY CATAWBA NUCLEAR STATION

+

HP/0/B/1009/04 ENCLOSURE 5.9 EMERENCY VEHICLES 5.9.1 The two designated emergency vehicles are the I&E and Health Physics vans.

The two vehicles are to be obtained (as directed by the FMC) by doing the following.

u 5.9.1.1 IE Van l

5.9.1.1.1 Go to the ISE Test Equipment Issue area (Elev. 594, Col. S27, Re# 5473) and request the use of the van for emergency iue.

5.9.1.1.2 If no one from IH is available for issue, get keys from HP Eey box.

4 5.9.1.1.3 If the vehicle is off-site request the FNC to contact the vehicle by TSC radio, have the vehicle to return i

to site immediately and obtain use when it returns.

i 5.9.1,2 Health Physics Van 5.9.1.2.1.

Go to the Tech Services Clerk and obtain keys for use.

5.9.1.2.2 If Tech Services clerk is not available, get keys from the HP Eey box.

5.9.1.2.3 If the vehicle is off-site request the FMC to contact the vehicle by TSC radio, have the vehicle return to site immediately and obtain use when it returna.

i I.

5.9.2 Obtain any other Station vehicle (if available) as directed by the FMC.

5.9.3 Voluntary use of personnel vehicles is another alternative that may be considered but should be a last option.

)

_ -, ~. _. - _ _ _,

. _ _ _ _. _ _. _ _. _ _ _.. _ _., _ _. _ _. _ _ _,... _ _ _ _ _.. _ - _.. _ ~...,

eO 5

e e

D 4

4 s

.l D

h h

_^_

(.

0 h

o e

4 e"

O e

4 Form 34731 (3-84)

(1) 10 No.HP/0/B/1000/06 O

DUKE POWER COMPANY Change ts) to PROCEDURE PROCESS RECORD g

incor'porated PR EPAR ATION (2) STATION catm.rba Nucient (3) PROCEDURE TITLE F"arcency Ecuinment Functional Check and Inventory (4) PREPARED BY M

Mb --, -

DATE 7 b"/ - P6a d* M -

b (5) REVIEWED BY DATE

  • $ haw #

Cross Disciplinary Review By N/R (6) TEMPORARY APPROVAL (tf Necessary)

By (SRO) Date

~

Date By

^

)

(7) APPROVED BY DATE i

I i

(8) MtSCELLANEOUS

(

Reviewed / Approved By Date Reviewed /Aporoved By Date COMPLETION (9) DATE(S) PERFORMED (10) PROCEDURE COMPLETION VERIFICATION O Yes O N/A Check lists and/or blanks properly initialed, signed, dated or filled in N/A or N/R, as appropriate?

O Yes O N/A Listed enclosures attached?

O Yes O N/A Data sheets attached, completed, dated and signed?

Oyes O N/A Charts, paphs, etc. attached and properly dated, identified and marked?

O Yes O N/A Acceptance criteria met?

VERIFIED BY DATE (11) PROCEDURE COMPLETION APPROVED DATE (12) REMARKS

./

4 i

- - - = - -

-,,,-,,-y._-.,wr.__.L.---,

v

-w-

l HP/0/B/1000/06 DUKE POWER COMPANY CATAWBA NUCLEAR STATION i

EMERGENCY EQUIPMENT FUNCTIONAL CHECK AND IhYENTORY 1.0 PURPOSE To provide for the availability and readiness of Emergency Equipment.

2.0 REFERENCES

2.1 HP/0/B/1005/08; Respirator Quality Assurance 2.2 HP/0/B/1009/19; Emergency Radio System Operations, Maintenance and Communications 2.3 Catawba Nuclear Station Directive 2.11.13 2.4 Catawba Nuclear Station Directive 3.2.2 2.5 Catawba Nuclear Station Directive 3.3.3

,.m 2.6 Catawba Nuclsar Station Emergency Plan

\\'#

2.7 Catawba Nuclear Station Technical Specifications 6.8.1 2.8 Duke Power Company Radio Operator's Manual 2.9 Maintenance of Silver Zeolite Air Sampling Cartridges Letter; File: CN-768.01 2.10 10CFR 50 Appendix E 2.11 Technical Manual for Groban Gasoline Generators 2.12 Shelf-life of Health Physics clothing; File: CN-766.00.

3.0 LIMITS AND PRECAUTIONS 3.1 Operation of Portable Generators 3.1.1 Avoid operating the unit while hands are wet or while standing in water.

3.1.2 Generators shall not be started while equipment is plugged into generator.

3.1.3 Low voltage rubber gloves should be worn while operating the generators. These gloves are stored with the generators.

3.2 Silver zeolite cartridges shall be discarded if the seal has been broken.

9 y

HP/0/B/1000/06 Page 2 of 7 3.3 Any radiation monitoring equipment (located in an emergency kit) that must be removed from service for any reason shall be replaced as soon as possible.

3.4 Any emergency kit used during training or for drill purposes shall 4

be reinventoried as soon as possible. The individual responsible

.j for the training or drill shall be responsible for inventory and

'l restocking of all on-site kits.

3.4.1 Off-site kits shall be reinventoried as above and a list of deviations shall be given to the Respiratory / Instrument Calibration (R/IC) Supervisor. R/IC shall be responsible for restocking off-site kits as soon as possible.

4.0 PROCEDURE 4.1 Monthly Emergency Equipment Check / Inventory 4.1.1 Portable Generator Check i

4.1.1.1 Portable generators shall be considered acceptable for use if:

4.1.1.1 The oil level is at an acceptable level per Reference 2.11.

4.1.1.2 The generator starts and runs.,focm.

at least 5 minutes.

4.1.1.3 The generator stabilizes after a portable air sampler is plugged into each of the generator outlets.

4.1.1.2 If generator is acceptable, shut off genetaior and remove any excess gasoline from the gas tank.

N 4.1.1.3 Document the operability of the generators in

~

the appropriate column on the Monthly / Quarterly Emergency Equipment Check Sheet (Enclosure 5.1).

4.1.2 Two-Way Low Band FM Radios 4.1.2.1 The radios shall be considered acceptable for use if:

4.1.2.1.1 Each radio transaits a message to another radio.

1 4.1.2.1.2 Each radio receives a message from another radio.

i i

4.1.2.2 Document the operability of the radios in the appropriate area on Enclosure 5.1.

HP/0/B/1000/06 Page 3 of 7 4.1.2.3 Inoperable radios shall be removed from service.

Contact Toddville Communication Shop Planner

)

for instructions on disposition for repair.

j 4.1.3 Batteries 4.1.3.1 All batteries shall be considered acceptable for use if:

4.1.3.1.1 The battery tester needle indicates

" good" when the battery is tested.

j d

4.1.3.1.2 The battery appears to be in good physical condition (no dents, corrosion, etc.).

4.1.3.2 Document battery check on Enclosure 5.1.

4.1.4 Portable Survey Instruments 4.1.4.1 Portable Survey Instruments shall be considered acceptable for use if:

4.1.4.1.1 The instrument battery checks.

3 4.1.4.1.2 The instrument source checks in accordance with the instrument.'.s..

operation procedure.

4.1.4.1.3 The instrument has no apparent physical damage.

4.1.4.1.4 The instrument has been calibrated within 3 months +/- 7 days.

4.1.4.2 Document the instrument's operability on.1.

4 4.1.5 Portable Air Samplers 4.1.5.1 Air Samplers shall be considered acceptable for use if:

4.1.5.1.1 The sampler operates when plagged into an electrical outlet.

4.1.5.1.2 The calibration date on the sampler is current.

4.1.5.1.3 The sampler has no apparent physical damage.

l r

i l

u

s HP/0/B/1000/06 Page 4 of 7 4.1.5.2 Document the sampler's operability on Enclosure 5.1.

4.1.6 Respiratory Equipment 4.1.6.1 Respiratory equipment shall be considered acceptable for use if:

4.1.6.1.1 The equipment is in accordance with criteria stated in Reference 2.1.

4.1.6.1.2 The Emergency Self-Contained Breathing Apparatus (SCBA) are available at the following locations:

Locations Minimua Units Control Room 2

Upper Personnel Hatch 2

Lower Personnel Hatch 2

Health Physics Respiratory Storage Area 8

i e

4.1.6.1.3 Six large cylinders of breathing

(

air (minimum of six hours used for 5 people) are located in the - -- -

Control Room along with 5 airline respirators and associated airline hoses.

4.1.6.2 Document operability of respiratory equipment in accordance with Reference 2.1.

4.2 Quarterly Emergency Equipment Inventory / Inspection f

4.2.1 Emergency equipment kits shall be inventoried quarterly j

and after each use using the appropriate Emergency Equipment Kit List of Contents (Enclosures 5.4 - 5.13)

I 4.2.1.1 Consult the Emergency Equipment Kit Location Sheet (Enclosure 5.2) for the locations of each 6

kit.

4.2.1.2 Perform monthly checks as in Steps 4.1.1, 4.1.3, 4.1.4, 4.1.5, 4.1.6.

4.2.1.3 The quarterly operability check on two-way low band radios shall be performed as follows:

4.2.1.3.1 Radios shall be checked from a point 10 miles from the plant in accordance with Reference 2.3.

P

.r

HP/0/B/1000/06 Page 5 of 7 s

4.2.1.3.2 Contact shall be made from the base station in the TSC to each of the radios.

4.2.1.3.3 Each of the radios shall make l

contact with the base station.

l' NOTE: Base Call Sign Radio Call Signs (Alpha, Bravo, Charlie, Delta, Echo, Foxtrot) 4.2.1.3.4 Document operability of radios on.1.

4.2.1.4 Perform a functional check of the dosimeter charger / reader. The charger is acceptable for use if the charger light illuminates.

4.2.1.5 Ensure that the leak and source check dates on the dosimeters are current.

4.2.1.6 Ensure that the TLD's are the appropriate ones

(,

for the current quarter.

4.2.1.7 Ensure the Potassium Iodide tablets have not exceeded their expiration date.

4.2.1.8 Ensure the seal on the silver zeolite cartridge packet is not broken and the cartridges are not i

i damaged.

4.2.1.9 Ensure that all procedures are current with the I

Control Copy.

4.2.1.10 Ensure the fiashlight bulb illuminates Properly.

4.2.1.11 Check all protective clothing to ensure it has not exceeded the recommended shelf-life per i.15.

l 4.2.1.12 Ensure that GMR-I canisters have not exceeded their expiration date.

4.2.1.13 Document any deviations on the Emergency Equipment Deviation Authorization Sheet (Enclosure 5.14).

2 E

HP/0/B/1000/06 Page 6 of 7 4.2.1.14 The Technician shall sign off Enclosure 5.1 and forward to the Respiratory / Instrument i

Calibration (R/IC) Supervisor.

4.2.2 Weather Information Check l

4.2.2.1 Quarterly a call shall be placed to the National Weather Service located in Colunbia, SC at 803-794-2330 or 803-794-2593. If these numbers cannot be reached, an alternate number in Charlotte (704-399-6000) may be used.

Obtain wind direction, wind speed, and cloud cover from one of these sources for the vicinity of Catawba Nuclear Station.

L 4.2.2.2 Obtain the same information from the Control Room.

4.2.2.3 Record this information on the Weather Information Form (Enclosure 5.3).

4.3 Deviation Authorization 4.3.1 The Station Health Physicist shall be made aware of any deviation recorded on Enclosure 5.14.

s i

~'

4.3.2 The Station Health Physicist shall have evaluated the ---.

consequences the deviation may have upon the capability to respond to an emergency situation.

4.3.3.14 shall be used to state the action taken to l

remedy the deviation, and to state the justification for taking that action.

4.4 Upon completion of this procedure all required documentation will be filed in the Emergency Equipment Functional Check and Inventory Log, until thc end of the quarter.

4.4.1 At the end of the quarter all of the required documentation will be placed in the Health Physics Satellite Master File.

4.4.2 Sign off the PT printout and forward as per Reference 2.4.

5.0 ENCLOSURES j

5.1 Sample of Monthly / Quarterly Emer8ency Equipment Check Sheet 5.2 Sample of Emergency Equipment Kit Location Sheet 5.3 Sample of Weather Information Form 5.4 Sample of Recovery Kit List of Contents t

o HP/0/B/1000/06 Page 7 of 7 5.5 Sample of Environmental Survey Kit List of Contents

  • 5.6 Sample of Environmental Survey Kit List of Contents (Helicopter) 5.7 Sample of Personnel Survey Kit List of Contents 5.8 Sample of Personnel Survey Kit List of Contents (Evacuation Facility) 5.9 Sasple of Emergency Medical Kit List of Contents (First Aid Room) 5.10 Sample of Emergency Medical Kit List of Contents (Piedmont Medical Center) 5.11 Sample of Operations Support Center Kit List of contents 5.12 Sample of Technical Support Center Kit List of Contents 5.13 Sample of Fuel Transfer Kit List of Contents 5.14 Sample of Kaergency Equipment Deviation Authorization Sheet 5.15 Sample of Recommended Shelf-life for Protective Clothing 3

?

wg

  • b.

i

+

4

-l

- i

~

t

./

4 i

5

Page 1 of 2 CATAVBA NUCLEAR STATION MONTHLY / QUARTERLY ENERGENCY EQUIPMENT CHECK SHEET HP/0/3/1000/06 ENCLOSURE 5.1 g

5g a

8 l

w

?!

a-ads o

u i

n m

e E 4 E e

i a a C 2 g o

SIGNAnmE/DATE Environmental Survey Kit - A Environmental Survey Kit - B Environmental Survey Kit - C Environmental Survey Kit - D i

Environmental Survey Kit - E Racovery Kit - Allen Raccvery Kit - Transmission Line Maint.

Racsvery Kit - Security Pap Area E try Kit - Construction Personnel Area Parsonnel Survey Kit -Allen Parsonnel Survey Kit - Transmission Line Maint.

I Parsonnel Survey Kit - Security Pap Area l

Parsonnel Survey Kit - Construction Personnel Area Emergency Medical Kit - First Aid Room Emergency Medical Kit - Piedmont i

Medical Center W rations Support Center Kit Iachnical Support Center Kit l*

Fuel Transfer Kit I

I

,-,-.,n-,

en,.

i 1

Page 2 of 2 MONTHLY / QUARTERLY EERGENCY EQUIPENT CECXSEET

-~

HP/0/B/1000/06 ENCLOSURE 5.1 CASOLIE GENERATORS Generator Number Comments Signature /Date

i i

i

' l PORTABLE RADIO TRANSMITTER - RECEIVERS i

i

(

Radio Call Sign Comments Performed At Signature /Date w..,

-~~ ' ' '

10-Mile On Site e

i 1

I I

../.

e i

n

--,,,,-+,..e

,n

,e.g.,,,,

,.s

,-m-v,.

.-.n w--

CATAWBA NUCLEAR STATION EMERGENCY EQUIPMENT LOCATION SHEET HP/0/B/1000/06

i,

ENCLOSURE 5.2

.f f

KITS LOCATION Recovery Kits (4)

Evacuation Facilities (2)

Allen Steam Station

.j Transmission Line Maintenance Building Security Pap Area Temp. Admin. Building Construction Personnel Access Area Temp. Admin. Building

)

'l Environmental Survey Kits (Vehicle) (4)

Temp. Admin. Building Environmental Survey Kit (Helicopter) (1)

Temp. Admin. Building Personnel Survey Kits (4)

Evacuation Facilities (2)

Allen Steam Station Transmission Line Maintenance Building Security Pap Area Temp. Admin. Building Construction Personnel Access Area Temp. Admin. Building Emergency Medical Kit (2)

Aux. Building First Aid Room Piedmont Medical Center

]

Operations Support Center Kit Operations Support Center q

Technical Support Center Kit Technical Support Center Fuel Transfer Kit Temp. Admin. Building

]

l

_I

~

l L

CATAWBA NUCLEAR STATION WEATHER INFORMATION HP/0/B/1000/06 ENCLOSURE 5.3 National Weather Service Control Roos i

j Wind Direction Wind Speed

}

Cloud Cover Time e

eag> W*

Go e Signature /Date

,i 1

e 9

\\

f

.--.--yw-7 3+-

r

+.,,-

r

,..we.y,-r-,,,

CATAWBA NUCLEAR STATION RECOVERY KITS LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.4 MININUM ITEM AMOUNT List of Contents 1

Eberline E-520 w/HP-270 Probe 1

Exempt Source 1

Low /High Range Dosimeters (0-500 mR), (0-SR) 2 each Dose Cards 25 TLD Badges 6

Dosimeter Charger 1

Boundary Ribbon or Rope (50 yd. roll) 1 Masking Tape (roll) 1 Rain Suits (set) 2 Coveralls: Cotton 2

Gloves:

Cotton (pair) 2 Rubber (pair) 2 Shoe Covers:

Disposable (pair) 2 Rubber (pair) 2 Hoods: Cotton 2

Poly Bass (Various) 12 Caution Signs w/ inserts 2

Legal Pad 1

Instrument / Smear Survey (pad) 1 Pens 2

Grease Fencil and refills 1

Full Face Respiratior With GMR-I Canister (or equivalent) 2 First Aid Kit 1

Potassium Iodide Tablets Trans. Line Maint.

275 bottles Security PAP 150. bottles Construction Personnel Area 150 bottles Allen Steam Station 275 bottles KI Distribution Data Sheet 100 l

Smears (box) 1 Nucon Smears 30 Flashlight 1

Batteries (Size D) 10 Scissors 1

Medication Envelopes Trans. Line Maint.

100 Security PAP 60 Construction Personnel Area 60 Allen Steam Station 100 Crisis Management Team Phone Directory **

1 SLED Badges (Personnel and Vehicle each)**

100 Emergency Planning Zone Maps **

3-HP/0/B/1009/16 1

,s

  • Any Deviations will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).
    • These items are found only in the Recovery Kits located at Allen Steam i

Station and Transmission Line Maintenance Building.

l i

e Page 1 of 2 CATAWBA NUCLEAR STATION ENVIRONMENTAL SURVEY KITS LIST OF CONTENTS s

HP/0/B/1000/06 ENCLOSURE 5.5 MINIMUM ITEM AMOUNT List of Contents 1

Eberline E-520 w/HP-270 Probe 1

Eberline E-140N w/HP-210 Probe (or equivalent) 1 I

Exempt Source 1

i Portable MCA**

1 Eberline PIC 6A 1

Emergency Radio Transmitter / Receiver 1

Radeco H809V Air Sampler 1

Gasoline Generator (Gasoline in Safety Cabinet) 1 Low /High Range Pocket Dosimeter (0-500 mR), (0-5R) 2 each Dose Cards 25 TLD Badge 6

Dosimeter Charger 1

Full Face Respirator With GMR-I Canister (or equivalent) 2 Potassium Iodide Tablets (bottle) 2 Tyvek Disposable Coveralls 6

Tyvek Disposable. Hoods 6

Coveralls: Cotton 4

Gloves:

Cotton (p' air) 8 Rubber (pair) (Size 7), (Size 9) 2 each Shoe Covers:

Disposable (pair) 4 Rubber (pair) 4 Hoods: Cotton 4

Sandwich Bags (box) 1 Poly Bass (Various Sizes) 6 Masking Tape (roll) 1 Compass 1

Tweezers 1

Limnological Sampler 1

Cubitainers 6

1 Liter Wide Mouth Bottles 5

Stopwatch 1

Battery Operated Latern 1

Flashlight 1

Batteries (Size D) 14 Batteries (9 volt) 4 Batteries (6 volt) 1 Silver Zeolite Filter Cartridges 30 Particulate Filters Filter Cartridges Labels & Bass 30 100 Smears (box) 1 Nucon Smears 30 l

Nap of Ten Mile Zone Sectors 1

Instrument / Smear Survey (pad)

I i

i j Legal Pad 1

Pen 2

Permanent Marker 1

i v

w - - -

v v

n v,v--

--,--+ra v

v-vv-

,,--w,--

w w

ev-v-w

Page 2 of 2 CATAWBA NUCLEAR STATION ENVIRONMENTAL SURVEY KITS LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.5 MINIMUM ITEM AMOUNT i

i Hand Spade 1

Grease Pencil and refills 1

Dime Roll 1

Scissors 1

i Rain Suits 3

Telephone location maps 1

1 Field Menitoring Data Sheet 20 Field Monitoring Work Sheet 20 KI Tablet Distribution Data Sheet 1

Radio Operator Manual 1

CPD1 Key 1

SLED Badges (Personal - Vehicle) 4 Reflective Safety Vests 2

HP/0/B/1009/04 1

HP/0/B/1009/16 1

HP/0/B/1003/17 1

HP/0/B/1009/19 1

  • Any Deviations will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).
    • This instrument is stored and maintained in the Health Physics Counting l

Room Area.

t S

CATAWBA NUCLEAR STATION ENVIRONMENTAL SURVEY KITS LIST OF CONTENTS (Helicopter)

HP/0/B/1000/06 ENCLOSURE 5.6 MINIMUM ITEM AMOUNT List of Contents 1

Eberline PIC-6A 1

Eberline E-520 w/HP-270 Probe 1

Exempt Source 1

Low /High Range Pocket Dosimeter (0-500 mR), (0-5R) 2 each l

Dose Cards 25 Field Monitoring Data Sheet 20 TLD Badge 6

Dosimeter Charger 1

Full Face Respirator with GMR-I Canister (or equivalent) 2 Potassium Iodide Tablets (bottle) 2 KI Distribution Data Sheet 1

Stopwatch 1

Flashlight 1

Batteries (Size D) 10 Batteries (9 volt) 4 Ear Plugs (pairs) 6 Map of Ten Mile Zone Sectors 1

Legal Pad 1

Pen 2

Rain Suits 2

Instrument / Smear Survey (pad) 1 Emergency Radio Transmitter / Receiver 1

HP/0/B/1009/19 1

HP/0/B/1009/04 1

HP/0/B/1009/16 1

1

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).

_y-

.s e,y-y

--+p,.-.w

---m.--y g

-,7-,

aq~y-e-c y9 m.

g,nv.yg

-+

Page 1 of 2 CATAWBA NUCLEAR STATION PERSONNEL SURVEY KITS LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.7 MINIMUM ITEM AMOUNT List of Contents 1

Eberline E-140N w/HP-210 Probe (or equivalent)***

2 Sample Slide Tray ***

1 Exempt Source 1

Emergency Radio Transmitter / Receiver **

1 Radio Operator Manual 1

Low /High Range Dosimeters (0-500 mR/hr), (0-5 R/hr).

2 each Dose Cards 25 TLD Badges 2

Dosimeter Charger 1

Full Face Respirator With GMR-I (or equivalent) 2 Potassium Iodine Tablets (bottle) 2 KI Distribution Data Sheet 1

Coveralls: Cotton 6

Gloves:

Cotton (pair) 6 Rubber (pair) 6 Shoe Covers:

Disposable (pair) 6 Rubber (pair) 6 Roads: Cotton 6

Boundary Ribbon or Rope (50 yd. roll) 1 Caution Signs w/ inserts 4

Masking Tape (roll) 1 Poly Bass (Various) 6 Smears (box) 1 Nucon Smears 25 Instrument /Saear Survey (pad) 1 Pens 2

Grease Pencil & Refills 1

Legal Pad 1

Scissors 1

Rain Suits 3

Decon Kit 1

1)

Rad con 2)

Rad Wash 3)

Paper Towels 4)

Scrub Brush 5)

Cotton Swabs 6)

Fingernail Clippers 7)

Phischez (125 al) 8)

Personnal Decontamination Forms Batteries (Size D) 10 Station Directive 3.8.3 1

HP/0/B/1004/06 1

HP/0/B/1009/05 1

HP/0/B/1009/16 1

HP/0/B/1009/19**

1

..m.

r.

.,,----e

.-___,_7_.,,,,_m.,

p,,.,.,,...,m.e.,yc_,,-.,.yw,,,.

-,.--_..,.,r-.

Page 2 of 2 CATAWBA NUCLEAR STATION PERSONNEL SURVEY KITS LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.7

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).
    • 0nly the Construction Personnel access area shall have an Emergency Radio and procedure.
      • The Security PAP Area shall have (3) E-140N w/HP-210 Probe or equivalent and Sample Slide Tray. The Construction Personnel Access Area shall have (2) E-140-N w/HP-210 Probe or equivalent and shall not have a Sample Slide Tray.

e w W*

b e e

i.

s 4

h l

l t

.... _.,,,, _, _ _,..,.,, ~, _. _., _ _ _

m

  • -N-eAmusui CATAWBA. NUCLEAR STATION PERSONNEL SURVEY KITS LIST OF CONTENTS (EVACUATION FACILITY)

+

HP/0/B/1000/06' ENCLOSURE 5.8 MINIMUM

)

ITEM AMOUNT List of Contents 1

Eberline E-140N w/HP-210 Probe (or equivalent) 3 Exempt Source 1

Low /High Range Dosimeters (0-500 mR), (0-5R) 4 each Dose Cards 25 TLD Badges 4

Dosimeter Charger 1

+

Potassium Iodide Tablets (bottle) 2 KI Tablet Distribution Data Sheet 1

Medication Envelopes 3

Coveralls: Cotton 6

]

Gloves:

Cotton (pair) 6 Rubber (pair) 6 Shoe Covers:

Disposable (pair) 6 Rubber (pair) 6 Hoods: Cotton 6

Disposable Coveralls 40 Boundary Ribbon or Rope (50 yd. roll) 1

Caution Signs w/ inserts 4

q Masking Tape (roll) 1 Poly Bass (Various) 6 Smears (box) 1 Instrument /Seear Survey (pad) 1 Pens 2

Grease Pencil & Refills 1

l Legal Pad 1

Decon Kit 1

1)

Rad Con 2)

Rad Wash 3)

Paper Towels i

4)

Scrub Brush 1

5)

Cotton Sw' abs 6)

Fingernail Clippers 7)

Phischez (125 al)

)

8)

Personnel Decontamination Forms i

Scissors 1

Station Directive 3.8.3 1

Evacuation Personnel Dose Record 50 Catawba Nuclear Station Telephone Directory 1

Batteries (Size D) 10 HP/0/B/1004/06 1

HP/0/B/1009/05 1

4 HP/0/B/1009/16 1

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).

4 i

i

CATAWBA. NUCLEAR STATION EMERGENCY MEDICAL KIT LIST OF CONTENTS FIRST AID ROOM HP/0/B/1000/06 ENCLOSURE 5.9 MINIMUM ITEM AMOUNT List of Contents 1

Eberline E-140N w/HP-210 Probe (or equivalent) 1 Exempt Source 1

Poly Bass (various sizes) 6 Seears (box) 1 l.

Nucon Smears 25 Coveralls: Cotton 6

Gloves:

Cotton (pair) 6 Rubber (pair) 6 Shoe Covers:

Disposable (pair) 6 Rubber (pair) 6 Hoods:. Cotton 6

Rain Suits 2

q Tape, Radioactive Material 1

Tape, Masking 2" 1

Tape, Duct 2" 1

Instrument / Smear Survey (pad) 1 Pens 2

-s Legal Pad 1

Caution Signs w/ inserts 3

Radioactive Material Tags 50 Scissors 1

Poly for Ambulances (bundles) 3 Batteries (Size D) 4 HP/0/B/1004/06 1

HP/0/B/1009/08 1

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).

i O

9 O

8 w

-s

+-n

-v----

n - -,~

---m-------,-,--

~~-,--, --,

e-n

CATAWBA NUCLEAR STATION EMERGENCY MEDICAL KITS LIST OF CONTENTS PIEDMONT MEDICAL CENTER HP/0/B/1000/06 ENCLOSURE S.10 MINIMUM ITEM AMOUNT List of Contents 1

Eberline E-520 w/HP-270 Probe 1

ii Eberline E-140N W/210 Probe (or equivalent)

I i

Exempt Source 1

j!

Poly Bass (various sizes) 14 Smears (box) 1 l'

NuCon Smears 25 Tape, Radioactive Material 1

Tape, Masking 2" 2

i Tape, Duct 2" 4

i:

Instrument / Smear Survey (pad) 1 Caution Signs w/ inserts 5

[

Rad Rope 1

TLD Badges 10 4

Pocket Dosimeters (0-500aR) 10 Dose Cards 25 Dosimeter Charger 1

Radioactive Material Tags 50

.,x

(

Floor and Vent Covering 1

Disposable Coveralls 25 Disposable Shoe Covers (pairs) 25 Disposable Hoods 10 Cubitainers 5

o Decon Kit 1

1)

Rad' Con 2)

Rad Wash 3)

Paper Towels 4)

Scrub Brush 5)

Cotton Swabs 6)

Fingernail Clippers 7)

Phischex (125 al) 8)

Personnel Decontamination Forms Cotton Gloves (pairs) 50 Rubber Gloves (pairs) 20 Batteries (Size D) 8 Grease pencils (box) 1 Stanchions 4

Trash Receptacle 2

HP/0/B/1004/06 1

HP/0/B/1009/08 1

3

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).

1 I

.. - L-. -,

....,,-..iL-,,.'..--..-----....-.--.-,.--

CATAWBA NUCLEAR STATION Page 1 of 2 OPERATIONS SUPPORT CENTER KITS LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.11 MINIMUM ITEM AMOUNT List of Contents 1

Coveralls: Cotton 40 Gloves:

Cotton (pair) 40 Rubber (pair) 40 Shoe Covers:

Disposable (pair) 40 Rubber (pair) 40 Hoods: Cotton 40 Full Face Respirators with GMR-I Canister (or equivalent) 10 Flashlights 11 Batteries (Size D) 34 Batteries (9 volt) 20 Eberline PIC 6A 5

RM-14 w/HP-210 Probe 1

E-140N w/HP-210 Probe (or equivalent) 1 Exempt Source 1

Camera (Polaroid) 1 Polaroid Film Pacs 2

Masking Tape (Roll) 2 Dosimeters (0-100R), (0-5R) 5 Dose Cards 25 Dosimeter Charger 1

(

Small Sample Bottles or Medication Envelopes 10 Rain Suits 5

~'

Poly Bass (various sizes) 50 Radeco H809V Air Sampler 3

l Silver Zeolite Filter Cartridges 30 Particulate Filters 30 Filter Cartridge Labels 30 Potassius Iodide Tablets (bottle) 20 KI Distribution Data Sheet 10 HP/0/B/1004/06 1

Decon Kit 1

1)

Rad Con 2)

Rad Wash 3)

Paper Towels 4)

Scrub Brush 5)

Cotton Swabs 6)

Fingernail Clippers 7)

Phischez (125 al) 8)

Personnel Decontamination Forms Instrument / Smear Survey (pad) 1 Telephone 2

Post-Accident Containment Air Sampling Equipment Kit 1

Pen (box) 1 Grease Pencil (and refills) (box)

I l

Extension Cord (50 ft.)

2 Extension Cords (25 ft.)

2 Stopwatch 2

1 Large Battery Lanterns (with 6 volt batteries) 4 Plant Drawings 1

l

!U 4

1 6

-[

i

O

'Q Page 2 of 2 CATAWBA NUCLEAR STATION 1

's' OPERATIONS SUPPORT CENTER KITS LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.11 MINIMUM ITEM AMOUNT OSC. Response Personnel Dose Record Forms 125 Seears (box) 1

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).

l

. - N.

\\.

I

w. -

l

)

l l

j Page 1 of 2 CATAWBA NUCLEAR STATION TECHNICAL SUPPORT CENTER KIT LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.12 MINIMUM ITEM AMOUNT p

List of Contents 1

Coveralls: Cotton 20 Gloves:

Cotton (pair) 20 Rubber (pair) 20 I

Shoe Covers:

Disposable (pair) 20 Rubber (pair) 20 Hoods: Cotton 20

)

Full Face Respirators with GRM'-I Canister (or equivalent) 6 Eberline E-520 w/HP-270 Probe 1

i Eberline PIC-6A 3

i E-140N w/HP-210 Probe (or equivalent) 1 Exempt Source 1

Radeco H809V Air Sample 1

Dosimeter (0-100R), (0-5R) 6 each Dose Cards 25 Silver Zeolite Filter Cartridges 30 Particulate Filters 30 Filter Cartridge Labels 25 Dosimeter Charger 1

m

(

) Potassium Iodide Tablets (bottle) 25 Boundary Ribbon or Rope (50 yd. roll) 1 i

Caution Signs w/ inserts 3

Rad Tape 2

Seears (box) 1 Poly Bass 6

4 Masking Tape (Roll) 1 Pen 2

4 Legal Pad 1

Grease Pencil (and refills) 1 Flashlights 8

Batteries (Size D) 30 i

Batteries (9V) 12 Small Sample Battles or Medica' tion Envelopes 10 l

Rain Suits 6

1 Decon Eit 1

i 1)

Rad con 2)

Rad Wash 3)

Paper Towels 4)

Scrub Brush j

5)

Cotton Swabs 6)

Fingernail Clippers 7)

Phischex (125 al) 8)

Personnel Decontamination Forms i

Instrument /Seear Survey (pad) 1 Request for Exposure Extension Forms 15

, Plant Drawings 1

l HP/0/B/1009/16 1

HP/0/B/1004/06 1

i

..-r--,

,m,

4

- CP Page 2 of 2 CATAWBA NUCLEAR STATION

..\\

TECHNICAL SUPPORT CENTER KIT LIST OF CONTENTS HP/0/B/1000/06 ENCLOSURE 5.12

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).

t t

e N

h a

U,, %

i i

1 6

l

_._.am

-sd.a-*

.m a

-- _ -m jl J

e-I.

i Page 1 of 2 4

i

- 3 CATAWBA NUCLEAR STATION t

FUEL TRANSFER KIT LIST OF CONTENTS HP/0/B/1000/06 l

ENCLOSURE 5.13 5:

.j MINIMUM

]

ITEM AMOUNT I

List of Contents 1

Shoe Covers:

Disposable (pair) 20 Rubber (pair)

'6 Gloves:

Cotton (pair) 20 Surgeons (box) 1 Rubber (pair) 6 j.

Coveralls: Disposable 4

Cotton 6

i-Hoods 4

Wet Suit 2

j.

Eard Hat 3

l:

Full Face Respirators with GMR-I Canister (or. equivalent) 2 Radeco H809V Air Sampler 1

Eberline E-140N w/HP-210 Probe (or equivalent) 1 l:

Eberline PIC-6A 1

Eberline E-520 w/MP-270 Probe 1

3

j Exempt Source 1

(

Silver Zeolite Cartridges and Particulate Filters 10 d

\\.

/

Labels for Filters and Cartridges 10 f

Potassium Iodide Tablets (Bottle) 30

?

TLD Badge 5

jj Low /Nish Range Dosimeter (0-500 mR), (0-5R) 5 each h

Dose Card 25 Dosimeter Charger 1

Weather-Proof Caution Signs with Inserts 4

Radioactive Waste Signs (4" x 6")

12 Caution: Radiation / Radioactive Material Tage 12 50 yd. Roll of Barricade Tape (Nagents & Yellow) 4 ii Step Off Pads 3

i Poly Bass 12 i

Hand Gardening Spade 1

j Wide Mouth Sample Bottles 4

Plastic Sample Bottles or Medication Envelopes 12 Kiswipes (bos) 2 i

Nucon Smears 100 Copy of NAC-1 Drawings (Prints) 1

. Copy of Loading and Unloading Instructions 1

Duct Tape (Roll) 2

{

Masking Tape (1" and 2" Rolls) 1 each i

Contact Pyrometer with Probe 2

1 Safety Glasses 5

Binoculars 1

Tool Xit 1

Batteries (9 Volt) 4

-'"l Flashlights 2

i Batteries (Size D) 18 Steno Fad with 2 Mechanical Lead Pencils 1

Pencil Refills 1

4 i

i l

1

Page 2 of 2

' 't CATAWBA NUCLEAR STATION FUEL TRANSFER XIT LIST OF C0hTENTS HP/0/B/1000/06 ENCLOSURE 5.13 MINIMUM ITEM AMOUNT a

Grease Pencils 2

All Purpose Marker 2

Scotch Tape Roll and Dispenser 1

Roll of Dimes 1

Gasoline Generator (Gasoline Stored in Safety Cabinet) 1 Instrument /Seear Survey (pad) 1 HP/0/B/1009/16 1

('

m

  • Any Deviation will be documented on the Emergency Equipment Deviation Authorization Sheet (Sample Enclosure 5.14).
  • +e

\\ -

l e

a e

8 9

.n.

,s.-

sp s

a l

l J

r l

i 4

l l

i I

I a

8:

~-

o g

5 E

3 s=

S e g

h suke 5

i 5

.w

.c 1

4 i

=

5..I 4

9..

(

as.

d*

  • t 33 i

l3 lI i

33

.l 3-5 W

W 1

I I

w

_m i

i.

es

.I 3

.S. 5 4

i c'}I

=

3 1

j I

u 7 3

i 2e i

i I

t

~

mmm -tyarw--

m w w -

y w ye

--h.e-am.,wwy-.

9 y---o g w w. w gym-gwy%,y.-=ve c o a-wowm99f-%w W 99pe-ewee-w*<-

e wy-s v-p-w e-4 ern mew =4mw-r p*g- 'e

, w e w'wewyh-hw-ar-1-.--

o 4

HP/0/B/1000/06 ENCLOSURE 5.15 CATAWBA NUCLEAR STATION RECOMMENDED SHELF-LIFE FOR PROTECTIVE CLOTHING l

Cotton Goods:

4 years Tyvek Goods:

4 years Duraguard Goods:

4 years l

Rubber overshoes 4 years l.

Vinyl Gloves:

6 months 5

Latex. Gloves:

6 months PVC goods:

1 year NOTE:

If the date marked on the protective clothing exceeds the allowable shelf-life, remove the protective clothing from the emergency kit.

e TI w..

i' i

)

L 1

l i

^

2 _ _ -. _,. - _ -, _. _.._

.~._..,_,._~~['

~~~~~~'!

,___-1*--

43REGo UNITED STATES

[

%j NUCLEAR REGULATORY COMMISSION i

5 j

WASHINGTON, D, C. 20555 i

%,,,,,+

May 22, 1986 50-413/414 Catawba 1

1 MEMORANDUM FOR:

Chief, Document Management Branch, TIDC FROM:

Director, Division of Rules and Records, ADM I

SUBJECT:

REVIEW OF UTILITY EMERGENCY PLAN DOCUMENTATION l

The Division of Rules and Records' has reviewed the attached document and has

, detennined that it may now be made publicly available.

hkJ Y

~A)

J Donnie H. Grimsley, Director Division of Rules and Records Office of Administration

Attachment:

As stated i

I I

e j

(

n I

't i

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS) fCCES$ ION NBR:.G64MMhbee4E DOC.DATE: 06/04/25 NOTARIZED: NO DOCKET #

FACIL: 50-413 Catewba Nuclear Station, Unit 1, Duke Power Co.

05000413 50-414 Catawba Nuclear Station, Unit 2, Duke Power Co.

05000414 AUTH.NAME AUTHOR AFFILIATION TUCKER,H.B.

Duke Power Co.

RECIP.NAME RECIPIENT AFFILIATION Record Services Branch (Document Control Desk)

SUBJECT:

Forwards Central Files version of revised emergency plan implementing procedures, including Changes O to HP/OB/1009/04, " Environ Monitoring for..."

HP/0/B/1000/06, " Emergency Equipment." Withheld.

COPIES RECEIVED: LTR I ENCL SI ZE:

DISTRIBUTION CODE: XOO5D TITLE: Emerg Plan (CF Avail)

NOTES:LPDR 2cus ANDTS to FSAR. ASLB icy.

05000413 LPDR 2cys ANDTS to FSAR. ASLB i c y.

05000414 RECIPIENT COPIES RECIPIENT COPIES ID CODE /NAME LTTR ENCL ID CODE /NAME LTTR ENCL PWR-A PD4 PD 1

O JADDOUR,K M

1 1

INTERNAL (ADM' DRR._.. -

w)1

/

f5_

1 IE/DEPER/EPB 2.,32 2,

IE/DEPER/IRB 1

1 REG FILES l

1 1

NOTES:

3 3

l 1

TOTAL NUMBER OF COPIES REGUIRED: LTTR 10 ENCL 9

_ _, ~ - _.. _ _..

_.,