C R' GINAL UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BRIEFING ON SHUTDOWN RISK PROPOSED

Title:

RULE FOR NUCLEAR POWER PLANTS -- PUBLIC MEETING Location:

Rockville, Maryland Date:

Wednesday, August 6,1997

}f0V e

Pages:

1 - 58 D

I alm '

f tv l$tpklhgc.\\&f Y

D O

ANN RILEY & ASSOCIATES, LTD.

'2#.ibi'ldT.'#

...q O

(202) 842 0034 1.i UV 7]S110 970006 l l{l l' lll g g' lj PT9.7 peg

e.

~ DISCLAIMER

-This is an unofficial transcript of a meeting of the United States Nuclear Regulatory Commission held on August-6, 1997 in the Commission's office at One White Flint North, Rockville, Maryland.

The meeting was open to public attendance and observation.

This transcript has not been reviewed, corrected or edited, and it may contain inaccuracies,

.TheLtranscript is intended solely for general

. informational purposes.

As provided by 10 CFR 9.103, it is not part of-the; formal or informal record of decision of the matters discussed.

Expressions of-opinion in this

transcript do not necessarily reflect final determination or beliefs.

No-pleading or other paper may be filed with the-Commission irt any proceeding as the result of, or addressed

-to,-any statement or argument _ contained herein,'except as the Commission may_ authorize.

4 D_

h

1 1

UNITED STATES OF AMERICA

-e 2

NUCLEAR REGULATORY COMMISSION 3

4 BRIEFING ON SHUTDOWN RISK PROPOSED RULE 5-FOR NUCLEAR POWER PLANTS 6

7 PUBLIC MEETING-8 9

Nuclear Regulatory Commission 10 Commission Hearing Room 11 11555 Rockville Pike 12 Rockville, Maryland 13 14 Wednesday, August 6, 1997 15 16 The Commission met in open session, pursuant to 17 notice, at 2:00 p.m.,

the Honorable SHIRLEY A. JACKSON, 18 Chairman of the Commission, presiding.

19 20 COMMISSIONERS PRESEN7:

21 SHIRLEY A. JACKSON, Chairman of the Commission

}

22 GRETA J. DICUS, Member of the Commission 23 EDWARD McGAFFIGAN, JR., Member of the Commission 24 NILS-J. DIAZ, Member of the Commission 25 b

Q ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 s

.-~.. -.. -.

2 1

STAFF AND PRESENTERS SEATED AT COMMISSION TABLE:

2 JOHN C. HOYLE, Secretary 3

STEPHEN G. BURNS, Associate General Counsel 4

JOSEPH CALLAN, EDO GARY HOLAHAN, Director, Division of Systems Safety 5

.6 and Analysis, NR".

7 TIM COLLINS, Team Leader, Shutdown Rulemaking 8

Task Force 9

TIM MARTIN, Acting Associate Director for 10 Technology 11 THOMAS KING, Deputy Director, Division of Systems 12 Technology, RES 13 l

l 14 l

15 16 17 18 19 l

20-21 22 23 24 25 ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

_.m__

I 3

1 PROCEEDINGS 2

(2:00 p.m.]

3 CHAIRMAN JACKSON:

Good afternoon, ladies and 4

gentlemen.

We are pleased to have the staff here to brief 5

the Commission on the propesed rulemaking for shutdown and 6

fuel storage pool operations at nuclear power plants.

7 In a September 12, 1994, staff requirements d

8 memorandum, the Commission approved the publication of the 9

proposed rule for shutdown and low-power operations for 10 public comment.

The statf has expended a considerable 11 amount of effort to address the public comments as well as 12 the Commission guidance regarding the use of a risk informed l

13 performance-based approach for this important issue.

14 During your discussion of the proposed rulemaking 15 for shutdown and fuel storage pool operation, the Commission i

16 is interested in examples which demonstrate the use of the 17 risk-informed performance-based approach in development of 18 this rule.

In addition, the Commission is interested in 19 hearing any lessons learned that could improve the 20 rulemaking process in the use of risk.

21 An initial comment I would make is it is

{

22~

important, whether it is on your viewgraphs or not, that you 23 kind of lay out or give some sense of the context in 24 historical -- the historical context, particularly since 25 this Commission is not the sa'e as the Commission that m

t x

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 i

4 1

issued the SRM in 1994.

2 I understand that copies of the presentations are 3

available at the entrances to the meeting room so, unless my 4

colleagues have anything to add to begin, Mr. Callan.

5 MR, CALLAN:

Thank you, Chairman.

Good afternoon, 6

Chairman, good afternoon, Commissioners.

7 With me at the table are Tim Martin, who is 8

filling in for Sam Collins, who is not available, and Gary 9

Holahan, the director of the Division of System Safety and 10 Analysis in the office of NRR.

11 Gary will introduce the members of the Shutdown 12 Rulemaking Task Force and then Tim Collins, who is the team 13 leader of the task force and, I might add, Tim is a very 14 recent -- very recent selectee as the new branch chief, SES 15 branch chief for the Reactor Systems Branch --

2 16 CHAIRMAN JACKSON:

Are you going to announce 17 Mr. Martin?

18 MR. CALLAN:

We have a yellow announcement on 19 that.

20 And Tim Martin, it is worth saying for the record, 21 Tim Martin is the naw office director of the Office of AEOD.

22 But for this meeting, they are going to be in their old 23 capacities and Tim Collins will proceed with the balance of 24 the presentation when Gary Holahan is finished with his 25 discussion.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 b

5 1

CHAIRMAN JACKSON:

I have to tell you, though this

(.

2 has no relevance to the meeting, but someone started talking 3

to me about a Tim Collins, in fact, Mr. Callan, earlier 4

today.

And I thought he was confusing and Janding Tim 5

Martin and Sam Collins but I see there really is a Tim 6

Collins.

7 (Laughter.)

8 MR. HOLAHAN:

I have had that problem myself.

9 Back in January of 1997, in response to a number 10 of internal and external comments on the staff's previous 11 efforts to develop a shutdown rule related to, Madam 12 Chairman, as you mentioned, the 1994 SRM.

We recognized 13 that there were a substantial number of public comments and, 14 in the time frame between the early '90s and now in the 15 later '90s, I think we have had some additional time to 16 think about what do risk-informed and performance-based 17 approaches to rulemaking mean.

18 So back in the beginning of this year, we really 19 stepped back to take a new look at how to address shutdown 20 rulemaking activities, to take public comments and sort of a 21 risk-informed approach in mind and we established a task 22 force and we gave them a due date of July 31 to produce a 23 rule and supporting data.

In fact, I think they met that 24-date by one day.

That is a pretty good performance by our 25 rulemaking standards, I'm afraid.

And Mr. Collins, who is ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 i

l

_m 6-1 the leader of that task force, will present the details of 2

that package.

3 But I would also.like to present the members of

]

4 that team so that you have a feeling for the scope and, in 5

fact, the level of effort involved in producing this sort of 6

. activity.

7 Eric Weiss is the -- sort of the associate team 8

leader.

He is section chief under the Reactor Systems 9

Branch, Gary Mizuno, senior attorney from OGC.

We felt it 10 was important to involve the OGC throughout the process and 11 not as an add-on at the end.

Warren Lyon from the Reactor 12 Systems Branch; Bob Tjader from the Tech Spec Branch; Bob

-13 Lata, senior operational engineer in the QA area; Kulin 14 Desai, who is not here today, in Reactor Systems; Steve 15 Jones from Plant Systems Branch to deal with the spent fuel 16 pool issues; John Monninger from the Containment Systems 17 Branch to deal with the containment issues; and last but 18 certainly not least, Marie Pahic.a from the Reliability and 19 Risk Analysis from the Probabilistic Safety Assessment a

20 Branch.

21 So I say about half of those people were dedicated-22 to this activity and the other half were involved as needed 23

-to contribute so it is a broadly thought out rule approach.

24 CHAIRMAN JACKSON:

Commissioner McGaffigan has a 25 very deep comment I think he wishes to make, ji ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 g

7 1

COMMISSIONER McGAFFIGAN:

I just have a question 2

as-to what happened after we got the comments?

The Federal 3

Register notice was October of

'94.

You got the comments in 4

by March of

'95, say.

It was a difficult period, a long 5

period.

And then 21 months passed.

What was the-6 action-forcing event in January where you finally decided we 7

better do something and what were -- what hap 7.oned?

8 MR. HOLAHAN:

Between the time that comments were 9

received -- and, in fact, I think Tim will mention it is 10 something like over a thousand comments were received, we 11 actually went back and took the version of the rule that we 12 had developed earlier and tried to accommodate those 13 comments and to produce a new rule.

14 There had been some criticisms of the quality of 15 the regulatory analysis.

So there was a rewrite of the rule 16 and a regulatory analysis.

In effect, a second version of 17 the rule was produced in that intervening period.

18 When we got rather late in that period, I think we 19 decided I think rightly but perhaps much later than we 20 should have, that we were not really on a success path, that 21 taking the approach that we had used and trying to build in 22 some additional flexibility, to try to patch up some of the 23 original regulatory analysis, simply wasn't leading us to a 24 success path and, in effect, it wasn't until we had seen a 25 rather fully developed second version of the rule that we ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C. 20005 (202) 842-0034

-. - -. ~

-. ~ -

B 1

thought that:this is not really what the Commission and what 2

the staff and what the industry would be comfortable with.

3 We weren't -- I don't think it represented what I would 4

consider our more modern thinking on risk-informed 5

performance-based approaches.

6 So at that stage, we really decided to go back to 7

ground zero and start over again and that is what has led us 8

to sort of a crash program over the last six months to 9

produce what is, in effect, a third version of the rule.

10 Obviously, if we were starting over again, we 11 would just build this version; we wouldn't have built either 12 of the previous two.

But I think the history of where we 13 are and what we learned through sort of the middle '90s has 14 contributed.a lot to where we are now and we probably should 15 have been smarter in the '94 time frame of sort of skipping 16 over that middle phase.

But things just didn't come 17 together at that point.

18 CHAIRMAN JACKSON:

Okay.

Go on.

19 MR. HOLAHAN:

Okay.

20 Tim, you take the --

21 MR. COLLINS:

Okay.

Could I have slide number 2, 22 please?

23 The first thing I want to do is give you an 24 outline of my presentation and give you'a statement of our 25 overall objective in putting together the proposed rule and ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

9 1

a little bit of history associated with it.

Then I want to 3

2-discuss what we perceive as the need for rulemaking, why we 3

think therr is this need.

In that discussion, I will cover 4

where we see weaknesses in the existing regulations and what 5

we think the risk significance of those weaknesses is.

6 Then I will go through a structure of the proposed l

7 rule and try to describe how it remedies the weaknesses that 8

we believe are present.

I will also summarize the 9

regulatory analysis results and then I have a slide which 10 discusses how we have tried to use risk-informed principles 11 in the development of this rule.

We tried to make a very 12 deliberate effort to use the risk-informed principles in the 13 task force phase of the rule development.

14 I also have a slide which gives a summary of the 15 changes to the rule relative to the 1994 version that was 16 last published.

And my last slide is a schedule of what we 17 hope to accomplish in the next year with regard to final 18 rulemaking.

19 Can I have slide number 3, please?

20

_The objective of the proposed rule is to define 21 requirements for cold shutdown, refueling a.d fuel storage 22 pool operations that are risk informed, clear, coherent and 23 enforceable.

This is not to say that there aren't any 24' regulations out there right now which covered different 25 parts, different phases of this operation.

But I think as ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 I

(202) 842-0034

30 1

you will see, as the presentation goes on, there are some 2

weaknesses and what we have tried to do is to fill in the 3

important gaps in a risk-informed way.

4 CHAIRMAN JACKSON:

Let me ask you this question, S

is the rule also performance-based or is it primarily risk 6

informed?

7 MR. COLLINS:

I would say it is primarily risk 8

informed.

It does have a performance element in, a specific 9

performance monitoring element that we have included.

10 Slide number 4?

11 This slide discusses the background, some of which 12 Gary has already touched on.

As was mentioned, this is not 13 the first time we have gone out for public comment on a 14 proposed rule for shutdown operations.

The previous rule 15 was published in October of 1994 and it attracted quite a 16 bit of interest from the public.

We received over a 17 thousand comments on the rule.

Many of these focused on the 18 regulatory analysis, inadequacies in the regulatory 19 analysis.

20-The industry indicated that the rule was much too 21 res'trictive and that it would severely impact outages, in 22 some cases up to as much as nine days' lengthening of 23 outages.

And the industry said that the rule was really 24 unnecessary because of voluntary actions that the utilities 25 have already put in place.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 i

t 11 1

In the course of working on the resolution of e

2

=those comments,-the Commission's policy-statement on PRA was 3

also issued.

That was in August of 1995.

So between 4

comment. resolution and incorporating the philosophy-of the 5

PRA-policy-statement, that drove us toward the revis?.on to 6

the rule. 'And along the way we met with the ACRS for a-7 status briefing.

That was in May of 1996.

8 The ACRS wrote a letter-following that meeting, 9

indicating that they agreed there was a significant or 10 important risk associated with shutdown operations.

They 11 thought that the rule that we proposed to them at that time 12 would probably lessen risk.

It was rather a lukewarm 13-response in that regard.

And they also-suggested at that 14-time that maybe we ought to consider a broader base lining 15 of shutdown risks.

16

-COMMISSIONER DIAZ:

Excuse me, just out laf i

17 curiosity'and history of the 1,023 public comments, how many-18 were in favor of the rule ~or how many were in disfavor of 19-the rule?

20 MR. COLLINS:

I think it was like 1,022 to 1, 21 COMMISSIONER DIAZ:

That is what I-was wondering.

22-All right.

23 (Laughter.)

24 CHAIRMAN JACKSON:

Commissioner McGaffigan?-

25 COMMISSIONER McGAFFIGAN:

What is-your prediction ANN RILEY & ASSOCIATES, LTD.

s Court Reporters 1250 I Street,.N.W., Suite-300 Washington',

D.C.

20005 (202) 842-0034 l

12 1

about public comments on the new rule if it goes out?

Wi? 1 2

it be 1,022 to 1 again?

I mean, because -- what?

3 MR. COLLINS:

I believe that this rule is far more 4

flexible than the previous rule and clearly more risk 5

informed so I would expect we may still get 1,022 to 1 but I 6

think that we have addressed many of the comments in the 7

previous --

8 MR. HOLARAN:

It's clear to me I have to send in 9

more comments next time.

13 (Laughter.)

11 CHAIRMAN JACKSON:

That's very good.

Very good, 12 MR. COLLIh3:

During 1996, we also had meetings 13 with NEI to try to understand industry's positions with 14 regard to rulemaking and we understood the industry position 15 to be that they didn't believe there was a need for 16 rulemaking primarily because of the voluntary actions that 17 were already in place or commitments that licensees had 18 made.

But they were willing to work toward the development 19 of a performance-based rule.

20 Late in the summer of

'96, the staff made a 21 decision to expand the scope of the rule to include fuel 22 storage pool operations and to consider external events.

23 And following the staff decision, the interactions with NEI 24 were-terminated at that point.

NEI felt that they couldn't 25 support a rule which included fuel storage pool and external ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

13 1

evente, is our understanding.

2 COMMISSIONER DIAS:

Why?

What was the reason to 3

include fuel storage at the time?

Why did we include fuel 4

storage with the low power and shutdown?

5 MR. COLLINS:

Well, it was included with low power 6

because the fundamental concern is heat removal.

It is just 7

more distant from the time of shutdown when you are in the 8

fuel storage pool.

Go we thought that, rather than a b

9 separate rulemaking effort on fuel storage pool operations, 10 we could just attach it to the shutdown rule since shutdown 11 is primarily concerned with decay heat removal as well.

12 tiR. HOLAHAN:

I would say there were two things.

13 One is the commonality of the technical issues.

Many 14

_ periods during the refueling, some of the fuel is in the 15 vessel, some of it is in the spent fuel pool and so we are 16 sort of a continuity of the treatment of the issues.

The 17 other was following the experience with Millstone and other 18 plants it was clear that the staff and the licensees didn't 19 have a common, clear understanding of what was expected of 20 the licensees with respect to their requirements in the 21 spent fuel pool area and we felt that something needed to be 22 done to clarify what was required, not necessarily that 23 there were more requirements but that there was sort of an 24 unacceptable lack of clarity as to what was expected of 25 licensees.

And in last year's study on spent fuel pools, ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 l

14 1 -.

there was a Commission meeting and a Commission paper.

We 2-had studied a number-of plants, we had identified 10 3

followup areas and in addition we had said that something 4

needed to be dcne generically to bring closure to the 5

understanding of what was expected.

So this is our 6

mechaniem for doing it, although it may have been done in 7

Pame other way, this we thought was an efficient way to do 8

that.

9 CRAIRMAN JACKSON:

Because of the continuity of 10 the issue?

11 MR. HOLAHAN:

Yes.

12 CHAIRMAN JACKSON:

I note that the ACRS had 13 recommended a benchmark study on risk during low power and 14 shutdown Operations.

How did this p3ay into this lule or 15 your schedule for it or how are you intending to address the i

16 ACRS comments?

17 MR. COLLINS:

We read that letter very carefully 18 and we had responded to the ACRS indicating that we were in 19 agreement with many of their recommendations, That letter 20 that they sent to us, the April letter, was not drafted in 21 the context of the review of the shutdown rule.

That was 22 drafted in the context of the review of risk-based 23 regulation as a whole.

24-You could read it to mean that well, maybe we 25 ought to hold op shutdown rulemaking but it was not drafted ANN RILEY & ASSOCIATES, LTD.

Jourt Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

15 1

in response to a review of shutdown rulemaking.

2 CHAIRMAN JACKSON:

And they plan, I understand, to 3

comment on this proposed rule again?

4 MR. COLLINS:

They asked to comment after the 5

resolution of public comments.

6 CHAIRMAN JACKSON:

Okay.

7 Mr. King?

8 MR. KING:

Yes, we are proceeding to gather 9

information and lay out our plans for doing these additional 10 risk studies as suggested by ACRS.

Currently, we would 11 expect to begin those in about a year and there is a lot of 12 information that has been developed since the previous risk 13 studies that we did back in 1992 so both domestically and 14 overseas and we want to build upon that.

15 CRAIRMAN JACKSON'.

Okay.

16 COMMISSIONER DIAZ:

Just a comment.

As you 17 progress in your presentation, I want to make sure that I 18 get a very distinct idea of why do you think the spent fuel 19 pools should be considered with the low power and the 20 shutdown operations, where ther? is a tremendous difference 21 in the configuration and lineup.

22 In one case, the reactor vessel is closed.

You 23 know, we can only access the reactor vessel through a series 24 of very well set systems and mechanisms.

In the other case, 25 the reactor vessel head is not there, it is sitting on the ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

16 1

side and you have a fuel transfer canal and there are very, 2

very, very distinctive issues.

3 We have decay heat all the time when we are at 100 4

percent power or whether we are at zero power.

So decay 5

heat is a common denominator for all operations in reactors 6

and I think there is a very, to me, cle9x, distinct 7

difference between low-power operation, shutdown and fuel 8

storage pool and I hope they will actually --

9 CHAIRMAP JACKSON:

Why don't we let them go on 10 with their presentation?

11 COMMISSIONER DIAZi For sure.

12 MR. COLLINS:

Well, we already discussed the ACRS 13 letter of April 18 and then in July of this year, we 14 forwarded the rule to the Commission.

35 Slide number 5, please.

16 In the next few slides, I plan to address why we li think there is a need for a-rulemaking.

The first step in 18 assessing the need for rule was a qualitative assessment.

19 We looked at the traditional safety functions that are 20 associated with reactor operation and we looked at how these 21 functions are protected by current requirements, both at 22 power and during shutdown operations.

I have listed on v 23 slide the six functions we focused our study on.

24 When we reviewed the requirements at power, we 25 found that such things that the general design criteria, the 6.

ANN RILEY & ASSOCIATES, LTD.

Court P.eporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

4 17 l

1 technical specifications,-Part-50, Appendix B, very 2

comprehensively protect these functions, When we took the 3

same look -- I'm going to slide number 6.

4 We took the same look at the protection provided 5

by current regulacions and tech specs during shutdown.

We 6

found that there were some issues which were not covered and 7

I have some of these listed on slide number 6.

The 8

availability of such things as injection capability is not 9

covered for PWRs during cold shutdown and refueling.

That 10 is, there are no technical specifications for ECCS in mode 11 five and mode six.

12 COMMISSIONER DIAZ:

This is specific technical 13 specificaticns?

14 MR. COLLINS:

Yes, technical specifications.

15 COMMISSIONER DIAZ:

They are clearly covered by 16 Appendix A and therefore by Appendix B.

17 MR. COLLINS:

Yes, the ECCS systems.

18 COMMISSIONER DIAZ:

Requirements during any normal 19 conditions which includes, of course, the shutdown.

20 MR. COLLINS:

The GDC certainly applied.

21 COMMISSIONER DIAZ:

Okay.

22 MR. COLLINS:

These are -- I have specifically 23 listed this as availability to differentiate that from 4

24 design requirements, Typically, availability is controlled 25 by the technical specifications _and we reviewed the standard ANN RILEY &_ ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W, Suite 300 Washington, D.C.

20005 (202) 842-0034

18 1

technical-specifications to see whether or not these 2

functions were covered during shutdown.

3 CHAIRMAN JACKSON:

So that is where the crux is, 4

having to do with availability?

5 MR. COLLINS:

It's availability.

We don't have 6

any concerns with tae capability of the systems to perform 7

their function if they are available, 8

CHAIRMAN JACKSON:

So that is what brings them 9

away from the general design criteria?

10 MR. COLLINS:

Right, the general design criteria 11 do not address availability.

12 CHAIRMAN JACKSON:

Okay.

And the only question I 13 would ask is did you consider revisions to Appendix B or 14 some other existing regula.tions?

I guess it really has to 15 do with your deciding it was better to treat all these 16 issues in a comprehensive way as opposed to trying to go 17 back and revise Appendix B?

18 MR. COLLINS:

That's correct.

19 MR. HOLAHAN:

In our previous versions of a 20 proposed rule, for example,-we proposed to have individual 21 technical specifications to control-the availability of 22 equipment.

But what we found is that normal operation is 23 m'ach simpler than shutdown activities.

During normal 24.

operation, most all systems are available and perhaps only 25-one at a time is taken out of service.

And so it is ANN RILE'l & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Mashington, D.C. 20005 (202) 842-0034 l

1

19 1

relatively straightforward to write requirements calling for 2_

all the equipment tc be available and'then giving outage 3

times if one piece is.-

4.-

A more complicated situation, I think, exists in 5

shutdown when there are numerous pieces of equipment taken-6 out of service and the combinations of those, I think, got 7

too complicated or overly conservative in trying to write

~

8 those into specific specifications.

9 COMMISSIONER DIAZ:

I just was trying to get a 10 nomenclature.

I don't know whether I have to change but 11.

since I was a kid when I started in this business, you know, L"

12 I don't want to say'how long ago, but it-was a long time 13 ago, normal operations including shutdown and low power.so 14 you can't call shutdown,-you know, a different type of 15 normal operations.

16-MR, HOLAHAN:

Yes.

-17 COMMISSIONER DIAZ:

Normal-operations includes 18 shutdown and that is part of normal operations _and they are 19 clearly addressed by Appendix B.

It.says~ operating 20 conditions.and all. operating conditions are covered,- - So 21 whether they are low power or shutdown, those are: all nonnal 22 operating conditions.

So:we cover them in different ways lbut now-if we want to specifically address them in a better 24 fashion, I understand that. 'But they have;always been 25 normal operating conditions, including shutdown.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 I

i

20 1

MR. CALLAN:

Commissioner, if I might add, the 2

point that you are making is a point that OGC has made 3

repeatedly in the discussions and during the pre-brief I 4

had, OGC made that very point, that there are regulations 5

that apply and your clarification is correct, that we are 6

improving or enhancing our ability, 7

COMMISSIONER McGAFFIGAN:

Could I follow up on 8

that?

One of the things you all do in this new rule, 9

though, is somebody must see some vulnerability there 10 because you add a definition in 50.2 of shutdown operation 11 and the last sentence of which, shutdown operation is part 12 of normal operations.

So somebody felt constrained in this 13 rulemaking package to make that crystal clear in regulation.

14 Is that because it may have been less than crystal clear 15 previously?

16 CHAIRMAN JACKSON:

We just wan;ed to be sure it 17 was perfectly clear.

18

.MR. HOLAHAN:

Perfectly clear.

This just came out of OGC',s 19 CHAIRMAN JACKCON:

20 comments.

21 COMMISSIONER DIAZ:

If I may comment on that, I 22 don't think there is anybody in the industry that has a 23 question that shutdown is part of normal operation.

If you 24 want to add clarity for some additional purpose, that's 25 fine.

But the NRC and the industry, correct me if I am ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

21 1

wrong, we all call shutdown power _ normal operations,

_,3 2 --

correct?

3 MR.' CALLAN:

Yes.

4-CHAIRMAN JACKSON:

But I think the point is not-so

.5-much-to get-hung up as to whether or not some existing 6

regulations include shutdown operations within the scope.

7 But if there are specific issues that you mentioned, 8

availability number one, that this rule specifically allows 9

us to deal with. -And, secondly, a sentence that maybe 10 states the obvious, if it really is obvious, and if it is 11 not obvious, either way, it doesn't-hurt to have it.

12 COMMISSIONER DIAZ:

It doesn't hurt, but it is 13 obvious.

14 CHAIRMAN JACKSON:

This makes it obvious to all.

15 Okay, let's go on.

16 MR. COLLINS:- Some other functions that we found 17 were lacking in the current requirements,.the availability 18 of BWR venting.

That is the ADS-system we are referring to-19 there.

In BWRs, ECCS is' required during cold shutdown.

20 However,-the ADS is not required and the ECCS required-is 21 low-pressure systems.

And should you have a pressuri=ation 22

' event, you wouldn't be able to=use the ECCS anyway.

23:

Containment is required under very limited 24 conditions right_now-in~the standard technical 25 specifications.

There are other areas where the current-i ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite-300 Washington, D.C. 20005 (202)-842-0034

l 22 1

requirements are what we would describe as maybe partial, 2

they don't fully address some functions.

Fire protection 3

for cold shutdown equipment is an important area.

50.48, 4

Appendix R and GDC-3 all t:: eat fire protection.

When we 5

looked carefully at them, it was clear that they focused on 6

a fire that started during power operations.

It requires 7

protection of equipment to a safe shutdown condition which 8

has been interpreted as hot shutdown.

9 If you have a fire that starts at cold shutdown, 10 that hot shutdown equipment would not be available.

You 11 typically need the reactor coolant system to be closed.

If 12 you are in refueling, the cooling system is not closed.

13 The only requirement for cold shutdown equipment 14 in the existing regulations is that it be recoverable 11 5 following a fire within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, Well, should a fire begin 16 in cold shutdown, 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is far too long to wait to 17 recover that equipment.

18 There are other requirements with regard to fire 19 protection that are tied to inerting.

BWR Mark I and Mark 20

.II containments operate in an inerted condition when they 21 are at power and, because of that, there has been a 22 relaxation in the equipment protection requirements relative 23 to fire.

When you are shut down, these containments would 24 not be inerted.

25 Finally, Appendix B, which addresses things like ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 52$"84$15634

23 1

procedures, corrective actions and QA, Appendix B applies to I

2 safety-related functions and the cold shutdown equipment is 3

not always classified as safety-related equipment.

Many 4

plants, the cold shutdown equipment is not classified as 5

safety related.

So the applicability of Appendix B is kind 6

of tenuous there.

7 COMMISSIONER DIAZ:

I'm sorry, 7 have to argue 8

with that.

9 Appendix B clearly says that QA will be 10 commensurate with the degree of safety.

So even if they are 11 not in the Q list, now, you might be right they are not in 12 the Q list, but they still have been QA to whatever degree 13 or measure of safety is.

So that doesn't mean they're 14 not 15 MR. CALLAN:

Let me give you a specific example 16 that I have been involved with over the years.

At even 17 newly licensed plants, the pressurized or the pneumatic seal 18 that provides a pressure fit around the gate on a refueling 19 canal is not -- frequently not captured by a licensee's QA 20 program.

When those seals fail, it causes'a fairly dramatic 2i drop in water level.

It is failsafe, in a sense, that it 22 won't go below a-certain level that provides adequate 23 protection but, nevertheless, it is a fairly dramatic event 24-when it happens and results in a lot of water in the 25 containment building during refueling outages.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

.1

24 1

That has happened a number of times around the 2

country.

Relatively recently, there has been I think at 3

least two generic communications out on that.

Just one 4

example of a fairly important component that is not captured 5

by an Appendix B program, it is not considered safety 6

related.

And I think there are arguments why it shouldn't 7

be.

8 And there are several other examples of that 9

nature.

10 COMMISSIONER DIAZ:

Well, it was not because if it 11 fails, it would have no consequences.

It is just messy and 12 transfers a lot of water --

13 MR. CALLAN:

Right, but you do get elevated 14 radiation levels depending on what's going on at the time 15 and that sort of thing.

16 CHAIRMAN JACKSON:

Mr. Holahan, you wanted to make 17 a comment?

18 MR HOLAHAN:

Well, I think that although Appendix 19 B could be read in some respect to apply to some of this 20 equipment, that is not the standard interpretation used in 21 the industry and since our objective was to reach some clear 22 understanding as to what was expected, I think we want to be 23 clear on how Appendix B ought to apply to such --

24 COMMISSIONER DIAZ:

But we already have, you know, 25 a guidance, I will say, in that we are going to go using ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

25 1

risk assessment and everything we have available to do i

L 2

graded QA and I am sure that that graded QA will eventually 3

involve all of these systems.

So we are ready to do actions 4

in that respect.

5 MR. HOLAHAN:

Yes.

But I think where a licensee 6

chooses to do the risk-informed graded QA, this would be 7

taken care of.

But we are approaching that as a voluntary 8

program so if a licensee doesn't choose to do this, I think 9

it won'i be different at that plant.

10 COMMISSIONER DIAZ:

Thank you.

11 MR. COLLINS:

All right, moving to slide number 7, 12 please.

L3 The second step of our analysis was to make a 14 quantitative assessment of the significance of the 15 weaknesses that we found in our qualitative assessment.

And 16 the first step we took in this was to try to make an 17 estimate of risk of plants that are operating, in normal 18 operation today.

The way we did that was we took NUMARC 19 91.06, which is an industry. sponsored guidance document for 20 shutdown operations management and we said, if we were 21 implementing this guidance, what equipment would we make 22 available during different phases of shutdown operation.

23 And then we did a risk estimate based on the availability of 24 that equipment.

25 That is the first line that you see on slide i

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

26 1

number 7 where it says, estimate of industry practice.

T 2

just want to make it clear that this is not a number that 3

the industry has provided to us, this is a number that we 4

have estimated ourselves.

You see that it comes up with 5

numbers that are in the vicinity of the Commission's safety 6

goal guidelines, quantitative guidelines.

7 Then the next step in our analysis was, what 8

happens if we remove from that things which are voluntary, 9

things which are not strictly required by the regulations, 10 and we remove things that are not included in technical 11 specifications, anything that was not specifically called 12 out in the regulations, and we also removed commitments made 13 in response to generic letters.

So it is really a stripped 14 down analysis.

15 If you took the tech spec requirements which were 16 our minimum during these modes of operation and only what 17 the strict regulations require, what happens then?

And that 18 gives us numbers which are well removed from the safety goal 19 guidelines.

Which was not surprising to us when you looked 20 at the safety functions involved.

21 I think the primary message from this, this 22 viewgraph here, is that the existing level of safety is very 23 heavily dependent on_ voluntary measures.

That ie the 24 message'we got from this analysis.

25 CHAIRMAN JACKSON:

What would the numbars look ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C. 20005 (202) 842-0034

27 1

like with the requirementu of the rule?

2 MR. COLLINS:

They come a lot closer to where the 3

industry is right now.

That is on a slide a couple slides

~

4 down.

5 COMMISSIONER DIAZ:

But again, let me see if I can 6

try to understand these numbers.

What you have, and let me 7

see if I understand what numbers apply, the numbers will be 8

different for say, mid-loop operations in a BWR?

9 M.

(OLAMAN:

Yes, yes.

10 COMMISSIONER DIAZ:

Than they will be when we are Il refueling.

So, in a certain way, the table, it is too much 12 of an average and we conclude --

13 MR. COLLINS:

These numbers are driven --

14 MR. HOLAHAN:

It's not an average.

It is an 15 integral.

It takes each of those situations but obviously 16 the dominant contributor is just the mid-loop operations.

17 COMMISSIONER DIAZ:

Right, it is an integral.

And 18 therefore, you know, it gives us a very, to me, I mean, I 19 look at it, I almost fell out of my chair, look at it, 20 flip-ficp, had to be given salta and all of that.

21

[ Laughter.)

22 COMMISSIONER DIAZ:

As you knew, it is a kind of 23 very, very distinct difference.

I think it is important to 24 realize that, and that is what I was talking about, 25 refueling operations and separating it from mid-loop in a ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

=_

l

28 1

BWR, that these numbers probably only apply to a very narrow 2-range of normal operations that were called mid-loop, going 3

from mode five to mode six.

4 MR. COLLINS:

To a degree, yes.

5 COMMISSIONER DIAZ:

And that really, you know, it 6

represents the risk in that area.

While the rirk, when the 7

fuel transfer canal in open and everything is at atmospheric 8

p>. essure, you know, a hose from the sanitary sewer can 9

provide enough cooling, you know, if we get into extreme 10 cases.

11

-MR. COLLINS:

Yes.

12 COMMISSIONER DIAZ:

So I think it is important 13 that we come out and separate them.

And now, having said 14 that, let me try to understand how we arrive at the, let's 15 call it the first column, the mid-loop operations of BWRs 16 and probability of core damage frequency of two to 10 to the 17 minus two per reactor year.

Is this the worst, worst, worst 18 case scenario?

Meaning, you have taken the fact that the i

19 system is sitting there and also you take the receivable 20 heat removal system out completely?

21 MR. HOLAHAN:

No.

22 COMMISSIONER DIAZ:

No?

23 MR. COLLINS:

No, we have used initiating event 24 frequencies that are historical data or are best estimates 25 at initiating event frequencies.

What happens is mitigation ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C. 20005 (202) 842-0034 e

29 1

equipment is gone and --

2 COMMISSIONER DIAZ:

So the receivable heat removal 3

system is gone?

4 MR. COLLINS:

No, not necessarily.

Things like 5

the CVCS would not be present, okay?

The ECCS is not 6

present.

Containment does not affect the core damage 7

frequency but it is not present either, okay?

8 And if you take a simple example, you have a loss 9

of level control in a PWR, which is not infrequent from our 10 perspective, and you don't have a makeup capability, you 11 can't recover even if you have two-hour HR systems 12 available, neither one of them can recover without first 13 having some water makeup, okay?

So something like a 14 loss-of-level control event occurring during mid-loop, you 15 can't recover from it.

All you need is the initiating event 16 frequency to get you these types of numbers.

17 CHAIRMAN JACKSON:

Why don't we go on.

We 18 can't 19 COMMISSIONER McGAFFIGAN:

Could I ask just one 20 question?

21 CHAIRMAN JACKSON:

Sure.

22 COMMISSIONER McGANIGAN:

NUMARC 91.06, is that 23 mandatory within NEI framework for its members or is that 24 voluntary?

Was that a voluntary guideline?

25 MR. HOLARANt Yes, it met their definition of an ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C. 20005 (202) 842-0034

=_ _

__a___

30 1

industry initiative which I think is comparable to mandatory 2

within the NEI framework.

3 COMMISSIONER DIAZ:

So that means that 80 4

percent 5

MR HOLAHAN:

Exactly, yes.

6 COMMISSIONER DIAZ:

Okay.

7 CHAIRMAN JACKSON:

Okay.

8 MR. COLLINS:

Moving on to slide number 8, this 9

slide is an outline of the rule as we are proposing it.

We 10 are trying to address each of the weaknesses that we have 11 identified in our analysis of current requirements.

12 The first element in the rule is a procedural 13 element that would require administrative tech specs be 14 added for all plants which would require that procedures in 15 quality assurance, training and corrective action be 16 included for activities that can affect decay heat removal, ft,rsafet$'functionperformancemonitoringandfor 17 18 activities associated with maintaining mitigation capability 19 available.

This is basically to account for the potential 20 Appendix B weakness.

21 The second element is the performance monitoring 22 element that we made reference to earlier.

Here, we have 23 defined safety function limits associated with water 24 temperature, reactor coolant system pressure and reactor 25 coolant system level.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 1 Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

=

=

31 1

And we have defined limito.

We have left it to 2

the licensees to decide how they would monitor those 3

parameters, what instrumentation they want to use, what 4

frequency they want to monitor it.

We would review the 5

methods and criteria used for determining what 6

instrumentation they were going to use and what frequency 7

they were going to use.

Should they violate any of the o

safety function limits, it would be a reportable event.

9 The third element in the rule is an administrative 10 tech spec requirement relating to mitigation capability.

We 11 have written the rule in very high-level langusge.

The rule 12 itself says that the licensees must maintain equipment 13 available to assure adequate core cooling and protection 14 against the uncontrolled release of fission products.

In 15 this statement of considerations and the res guide, we 16 discussed that we expect that to mean backup RHR and 17 injection capability and containment being intact, a 18 definition of which we provide in the statement of 19 considerations, or an alternative to the intact containment.

20 I think it is important to understand that in the 21 containment alternative, ue have made it c1. ear that the 22 containment provides a defense in depth function.

It is a 23

' diverse type of protection.

And that if a licensee chooses 24 to use the alternate to containment, they need to recognize 25 the defense in depth attribute that containment carries with i

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

-A

32 1

it and they can't simply put a second pump in place and say, l

2 well, I don't need a containment now.

They have to be able 7

3 to handle a wide range of initiating evento just as 4

containment would be able to handle it.

5 We also allow the licensee to choose whatever 6

equipment they want to use.

They must keep it, keep 7

documentation in a licensee-controlled document, the 8

document that will need to be identified in the tech specs 9

for the purposes of inspection and enforcement.

We don't 10 want to have the requirements spread out in a bunch of 11 different licensee documents.

We have asked them to put it 12 in one place so-that an inspector can go and understand what 13 is being relied upon at any given time in a shutdown.

14 We again would control the criteria and methods.

15 We would review the criteria and methods used for the 16 selection of equipment but the licensee would be free to 17 change out different types of equipment at different points 18 in the outage as long as they followed the methods and 19 criteria that were approved by the staff.

20 The fourth element of the rule is the fire 21 protection element.

I think the simplest way to think of 22 this is that we have tried to bring the protection afforded 23 at power operation into the cold shutdown regime.

The rule 24 would require that licensees either protect their cold 25 shutdown equipment from the effects of fire or if they can't 7004 RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

33 1

do that, they need to provide supprestiion and detection 2

equipment and to have contingency plans in place such that 3

if both trains of cold shutdown should be lost by a fire 4

that they can maintain core cooling by another mechanism.

5 CHAIMOW JACKSON:

Let me ask you a quertion.

6 How do you assess the inspectability and 7

enforceability of the performance monitoring aspects?

8 MR. COLLINS:

The inspectability, to a large 9

extent, is very straightforward once we have approved the 10 methods in the criteria because the licensee will have to 11 document what instrumentation is being used, what frequency 12 it ir being uced.

An inspector can simply go to that 13 document and say, show me that you have done this, and they 14 can review the records over the past year or at any moment 15 in time go in and say, show me.

16 CHAIRMAN JACKSON:

So that la how you both have 17 the inspectability and enforceability and-consistency in 18 inspection and enforcement?

19 MR. COLLINS:

Yes.

It does put some burden on the 20 headquarters staff in that we will have to review the 21 methods and criteria in advance.

It should facilitate 22 inspection and enforcement.

23 MR. HOLAHAN:

And the office of enforcement has 24 reviewed the package?

25 MR. COLLINS:

Yes, they have.

i ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,. Suite 300 Washington, D.C.

20005 (202) 842-0034

34 1

CHAIRFmR. TAC" SON:

Commissioner McGaffigan.

2 COMMISSIONER McGAFFIGAN:

On the fire protection 3

side, is there anything we are doing here that plays back 4

into when and if we ever get around to doing Appendix R and 5

getting rid of words like combustible and whatever, that 6

have you protected yourself against having to come back and 7

review this rule when we finally get around to doing that 8

rule?

9 MR. COLLINS:

Yes, we have worked with the Office 10 of Research in the development of this rule and as far as we 11 know, we are not doing anything contrary to what they plan 12 to do and as a matter of fact, they plan to incorporate what 13 we have done in shutdown into their own requirements as well 14 as they see it fits.

You know, they don't intend to redo 15 shutdown.

16 MR. HOLAHAN:

There were a number of discussions.

17 I think it wau recognized that fire protection for shutdown 18 was not fully covered in the regulations and there were a 19 number of discussions about how to address that.

We could 20 have just taken the 50.48 fire protection regulation and 21 written shutdown into it or it could have been done here or

~

22 it could be done in both.

Through the discussions as to 23 what looked like a reasonable way to do it and how that 24 could be referenced in a future change to 50.48 results were 25 sort of worked out before these words were developed.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

35 1

CHAIRMAN JACKSON:

Let's 90 on.

2 MR. COLLINS:

Okay, the last element in the 3

proposed rule is the one that addresses the fuel storage 4

pool.

The requirements here would be simply to update the 5

FSAR to incorporate the assumptions which are essential for 6

the design and safety functions of the pool and to be sure 7

that those assumptions were incorporated in the plant 8

operating procedures.

9 I believe the thrust here is that-there is the 10 perception of misunderstanding of what the expectations were 11 with regard to fuel storage pool operations, as evidenced by 12 the problems we have had in the past few years.

And risk 13 studies didn't indicate a compelling reason to have a rule 14 for fuel storage pool.

We didn't do any quantitative 15 assessment which says there is a heavy-duty risk here.

But 16 it is almost a matter of housekeeping to make it clear not 17 only to the licensees but also to the NRC staff what is 18 expected with regard to fuel storage pool operations and we 19 see this as cleaning the slate and making it clear from here 20 on out this is what is expected.

21 MR. HOLAHAN:

I would say that, because of the 22 decision we have come to, that in fact there are no 23 technical requirements, there is no real backfitting of 24 requirements here, this piece, this objective could be 25 accommodated in other ways.

The FSAR update rule could have ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C. 20005 (202) 842-0034

_d

1 36 1

some specific language with respect to spent fuel pools or the Commission could just express to the industry that its 2

3 expectation that 50.71(e) covers spent fuel pools but so 4

I think it is written in such a way that it is not an 5

essential element of this rule.

That piece could be taken 6

out and that issue could be dealt with separately.

7 CHAIRMAN JACKSON:

But is it written in a way that 8

is consistent with what ic already going on vis-a-vis 9

50.71(e)?

10 MR. HOLAMAN:

Well --

11 CHAIRMAN JACKSON:

It's hard to say?

12 MR. HOLARAN:

It's hard to say because I am not 13 sure exactly-where we are going with 50.71(e).

I think it 14 is not very prescriptive at all.

I think what it really says is whatever the current licensing basis is for spent 15 16 fuel pools, write that into your FSAR.

To the extent 17

50. 71 (e) is being pushed in that direction of saying get 18 that sort of stuff in your FSAR, I think that is consistent.

19 CHAIRMAN JACKSON:

Okay.

20 MR. CGLLINS:

There are a couple other conforming changes that go along with the rule which are not listed on 21 22 the slide.

Equipment which licensees wish to credit for the 23 shutdown rule would need to be included in the maintenance 24 rule program and for license renewal, any equipment which a 25 licensee wishes to credit for shutdown rule would also need ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 84 b3 1

37 1

to be covered in the license renewal.

2 Slide number 9.

3 Slide number 9 is the regulatory analysis results.

4 We have already seen the first two lines, the estimate of 5

industry practice and what is the base case in the 6

regulatory analysis.

7 The bottom line is where we would be -- an 8

estimate of where we would be if this rule was in place, 9

okay?

And, again, the rule basically raises the floor from 10 several orders ot magnitude away from the safety goal to 11 right in the vicinity of the safety goal guidelines.

12 COMMISSIONER DIAZ:

Subsidiary guidelines.

13 MR. COLLINS:

Subsidiary guidelines, yes.

14 Subsidiary objectives, sorry.

15 There is just one -- we have used the frequency of 16 unmitigated release as if it was a large early release.

In 17 fact, shutdown is slightly different because the short-term 18 products would all be decayed away before you would get to a 19 release in a shutdown accident.

Typically it takes a couple 20 days to get to cold shutdown.

21 CHAIRMAN JACKSON:

Does the rule accommodate 22 having NUMARC 91.06 being an acceptable methodology for 23 meeting the requirements of the rule?

24 MR HOLAMAN:

Not directly, although I think the 25 way the rule is structured, a licensee could propose the ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

38 1

program that they have under --

2 CHAIRMAN JACKSON:

91.06?

3 MR. HOLAHAN:

NUMARC 91.06 as their approach and I 4

think that could be reviewed and approved separately.

I 5

think 93.06 is not really a program, it is really a test of 6

how good is your program.

It is not really a definition 7

itself.

But I would think a program developed and 8

consistent with 91.06 --

9 CHAIRMAN JACKSON:

Would most likely meet the 10 requirements of this rule?

11 MR. HOLARAN:

I think if-you look at the risk 12 numbers --

13 CHAIRMAN JACKSON:

The risk numbers are very 14 similar?

15 MR. HOLAHAN:

Yes, I thir.k what it would do is it 16 would move that from a voluntary program into a more 17 structured regulatory approach.

18 MR. COLLINS:

Yes, NUMARC 91.06 is very high 19 level.

It is hard to answer the question directly, I mean 20 depending on how you implemented it.

21 CHAIRMAN JACKSON:

Okay, 22 MR. HOLAHAN:

I think it is fair to say the same 23 program and the same general use o!! equipment and its 24 availability would apply to both c ases.

25 CHAIRMAN JACKSON:

Okay.

ANN RILEY & ASSOCIATIS, LTD.

Court. Reporters 1250 I Street, N.W.,

Huite 300 Washington, D.C.

20005 (202) 842-0034

4 39 i

1 What du you mean by intact containment and does 2

the reg guide include definitions of these kinds of less 3

prescriptive areas?

4 MR. COLLINS:

de include a definition of the 5

intact containment.

It allows certain penetrations to be 6

open, provided that they can be closed automatically from 7

the control room.

It requires, though, that the closure be 8

able to withstand full design pressure.

He have given an 9

explicit-definition in the statement of considerations and 10 in the reg.

11 MR. HOLAHAN:

And correct me if I am wrong but I 12 believe it calls for one barrier as opposed to two?

13 MR. COLLINS:

Yes, one barrier, right.

14 CHAIRMAN JACKSON:

Okay.

Let's-go on.

15 MR. COLLINS:

Just one more comment, though, while 16 we are on this slide.

That is the ACRS letter talking about 17 the need for a benchmarking study.

If we look at the 18 results and the insights to be gained from the studies we 19 have done, I think it tells us that we really don't need te 20 have a big, comprohensive benchmarking study of low power 21 and shutdown to see that there is some weaknesses in our 22 existing regulations and we can address those weaknesses 23 very directly with the proposed rule we have.

24 The base case I don't think would change one iota, 25 regardless of how much of a comprehensive benchmarking study ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

40 1

you have done.

Once you take away important safety 2

functions, it becomes a very simple problem.

And the rule 3

case would be fine tuned.

But we are talking about a 4

thousand.co-one va3ue impact ratio in this cost / benefit 5

analysis.

We can't see how the overall insight is going to 6

be changed.

7 MR. HOLAHAN:

The one area that might be somewhat 8

different is I think that there hasn't been much research on 9

core melt in an oxygen environment for a shut down reactor.

10 I think in most cases, you know, we think of an at-power 11 case and core melt in a superheated steam environment.

So I 12 think some of the chemistry and some of the release 13 mechanism might be somewhat different and I think that 14 deserves a comprehensive thought.

In this case, I don't 15 think it changes the answers but I think it would bring a 16 better understanding of what sort of real risks are 17 associated with these shutdown conditions.

18 MR. COLLINS:

In addition to that, the way we have-19 written the rule, you know, it requires things like 20 adequate -- equipment for adequate core cooling and 21 uncontrolled release of fission products, protection against 22 that.

We wouldn't necessarily need to have a rule change to 23 implement insights from such a study and research anyway.

24 They would be plant-specific implementation if it is found 25 that certain equipment is particularly beneficial or certain ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I. Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

41 1

equipment is particularly vulnerable, those could be --

j 2

those insights could be incorporated without any change to 3

the rule.

4 CHAIRMAN JACKSON:

Okay.

5 MR. COLLINS:

Slide number 10.

6 The regulatory analycio numbers do not include 7

fire.

We didn't believe that we had the capability to do a 8

ge,,eric fire PRA for the purposes of the regulatory 9

analysis.

So, instead, we performed what 2 will describe as 10 a qualitative risk assessment and I have listed five factors 11 we believe are important in an assessment of risk from fire

-12 during shutdown operations.

13 What we did is we looked at how these factors are 14 protected by regulations at power, how they are protected by 15 regulations at shutdown and how the conditions associated 16 with these risk factors are different during shutdown as 17 opposed to power.

Our objective was, let's try to bring the 18 shutdown protection into-the same-regime as the power 19 operation protection.

20 We found the first factor is frequency of fires 21 during shutdown, there was an AEOD study.

We used the data 22 from that study that showed that the frequency of fires was 23 rather high during shutdown, on the order of 10 to the minus 24 two per. reactor year.

So initiating event frequency is 25 relatively high, comparable-to power operation.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C. 20005 1

(202) 842-0034

43 1

All the other factors, we found that the 2

conditions were either the same as at power or worse and the 3

protection afforded by the regulation was the same or less.

4 COMMISSIONER DIAZ Excuse me.

5 Could you be a little more specific?

Fires where, 6

in any --

7 MR. COLLINS:

Oh, right.

It was fires in areas 8

that could affect the safe shutdown equipment or the cold 9

shutdown equipment, I'm sorty.

That's right.

10 For example, if you look at the probability of 11 combustible loadings to allow fire to propagate, during 12 shutdown that is the time when you've got a lot more welding 13 equipment on site, you are doing combustible fluid changes, 14 you've got a lot of wood around to help with projects.

It 15 is just -- the conditions on a'.1 these factors were either 16 the same or worse from a risk perspective, which led us to 17 the conclusion that we could use some additional 18 requirements to bring these, the-protection, more up to the 19 standard at current power operation.

20 Slide number 11.

21 This is where we have assessed what the cost to 22 the industry would be from implementation of the rule.

23

'These costs are from today to the end of plant life.

For 24 the shutdown portion of the rule, we estimate it will be a 1

25 little under $2 million per plant.

These are primarily ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

~

43 1

paper costs.

It is just a matter of bringing something 2

which is currently in the voluntary regime into the 3

regulatory arena just costs some money.

We have included 4

some costs for instrumentation upgrade which some plants 5

could possibly need to do the performance monitoring portion 6

of the rule.

7 The fire protection, again, it ir a largely paper 8

cost.

There is some equipment, we heve included a cost for 9

some equipment which may be needed to enhance fire 10 suppression and detection equipment for cold shutdown 11 equipment.

12 A fuel storage pool operation is strictly a paper 13 exercise and it is about $50,000 a plant to update the FSAR 14 and modify procedures so the total cost for the entire rule 15 we would estimate to be less than $3 million per plant for 16 the lifetime of the plant.

17 CHAIRMAN JACKSON:

Is this above and beyond uhat 18-the licensees may already be doing to update their FSARs?

19 So this is kind of as 10 they have done nothing to this 20 point?

21 MR. HOLAHAN:

Yes, I think that's correct.

22 COMMISSIONER DIAZ:

Have you had some feedback on 23 this number from industry?

Has anybody said it's low?

24 MR. COLLINS:

No, they haven't seen these numbers.

25 They have not seen these numbers, 70R1 RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

44 1

CHAIRMAN JACKSON:

That is what the new comment 2

period will do.

3 Yes?

4 COMMIbSIONER McGAFFIGAN:

Could I ask, are these 5

numbers front loaded?

I mean, if you use paper exercise, in 6

che year after the rule goes into effect would most of this d

7 cost be incurred?

8 MR. COLLINS:

Yes, it would.

Yes.

9 MR. HOLARAM:

In some cases, all of it is just a 10 one-time cost.

11 MR. CALLAN:

Just anticipating some comments from 12 the industry, there is a hidden cost here that is not 13 reflected and that is, I guess, what you could call the 14 regulatory impact or the regulatory cost.

Now that what was 15 voluntary is now enforceable, that means that from time to 16 time, probably every outage, ther.e will be issues that will 17 be raised by the inspection staif that will have to be dealt 18 with and at no small cost in rome cases in terms of. staff 19 time and paper.

So there is that expense that is not 20 reflected here that would b's ongoing.

21 CRAIRMAN JACKSON:

Okay.

22 MR COLLINS:

Elide nunber 12.

23 Slide number

.*.2 discusses how we tried to take 24 into account the risk-informed principles in the development 25-of the rule.

There was a very deliberate effort to use risk ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C. 20005 (202) 842-0034

__a

45 1

insights throughout the development of the rule.

We used 2

PRA technology where we thought we had the capability.

We 3

did the quantitative accesoment for the shutdown portion.

4 We didn't think we had the capability to do a meaningful, 5

generic fire PRA and for the spent fuel pool there was no 6

need to do a PRA at all.

There were some previous studies

?

which showed that the risk of fuel damage was very low to 8

start with.

9 He tried to maintain defense in depth philosophy 10 in dealing with containment.

Obviously, the containment 11 can't alwaye be closed during refueling operations.

12 However, we didn't want to give up totally on defense in 13 depth so we wrote into the rule that the deferse in depth 14 attribute had to be considered when a containment alternate 15 was being used.

In the analysis, we tried not to use any 16 DBA assumptions at all.

We tried to be as realistic using information that was available to us in all our analyses.

17 18 Treatment of uncertainties, we did a qualitative 19 assessment of the uncertainties.

We used point estimates 20 for all the risk valueu and when we looked at the value 21 impact ratio being a thousand to one, we concluded that a 22 detailed uncertainty analysis is very unlikely to make any 23 changes to that conclusion so we didn't do anything further 24 after we did our qualicative assessment.

25 Finally, the safety goal subsidiary objectives ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 1 Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

1 46 3

were used throughout.

We used that to assecs where the 2

current regu'1ations put us, where the new regulations would 3

put us and where we thought the industry was today, i

4 CHAIRMAN JACKSON:

Okay.

5 MR. COLLINS:

Slide number 13 is a summary of what 6

has chat.ged sanec the rule last went out for public comment 7

in 1994.

The het shutdown and low power mo9es are no longer 8

within the scope of tne rule.

9 We did a more rigorous regulatory analysis where 10 we broke out the early phases in hot shutdown and low power, 11 looked at the regulatory requirements applicable to them and

)

12 concluded that, in fact, the safety functions were pretty 13 well protected by existing requirements.

So we withdrew hot 14 shutdown and low power from the scope of the rule..

15-The previous rule also had a requirement for the 16 containment closure was always required, containment closure 17 capability.

In thin rule, we try to be more flexible by 18 allowing alternatives to containment, provided that the 19 defense in depth consideration was maintained.

20 The previous rule also made broad use of the r

21 single failure criterion.

It was very reminiscent of 22 traditional dorign basis accident analysis type approach and 23 we have tried to use risk insights to limit the scope of the 24 single failure criterion and basically it now is a 25 requirement for a backup RHR.

ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

47 1

The licensee is allowed to set performance 2

monitoring limits in this rule.

We simply define safety 3

function limits related to water temperature, level and 4

pressure.

The licensee is free to decide how they want to 5

monitor _those.

If they want to correlate some other 6

parameter to those particular parameters, they are free to 7

do that provided that we have approved the methods and 8

criteria they are using.

9 The fuel storage pool was not addressed in the 10 previous version of the rule at all and the regulatory 11 analysis which supports this-rule, we think, is much more 12 rigorous than supported the 1994 rule.

In summary, we think 13 that it is much more flexible and risk informed than the 14 1994 version.

15 Slide 14 is the schedule titat we are hoping to 16 accomplish for rule implementation.

We would love to have 17 Commission approval by the end of the month to go out for 18 public comment.

19 CHAIRMAN JACKSON:

We will work on that.

20 MR. COLLINS:

Given that, it will take us a few 21 days to get the rule actually published.

22 CHAIRMAN JACKSON:

I've got the fast commissioner 23 over here anyway.

It shouldn't be a problem on that side.

i 24 MR. COLLINS:

We have allowed a 75-day comment 25 period which traditionally manages to get extended to 90 s

1 ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 4

48 1

days so we have shown 90 days on the schedule.

We plan to 2

meet with the ACRS then in next April following resolution 3

of public comments and we would have to go back to CRGR j

4 again.

We would anticipate doing that in May and t. hen 5

bringing the final rule to the Commission in August of next 6

year.

7 CHAIRMAN JACKSON:

Okay.

Any further comments or 8

questions?

9 Commissioner?

10 COMMISSIONER DIAZ:

Should the other commissioner 11-go first?

12 CHAIRMAN JACKSON:

No, you're the senior 13 commissioner.

14 COMMISSIONER DIAZr Let's see if I can organize a 15 couple of comments in here.

e 16 First, I think it is very important that the staff 17 focus attention in an area where I think we have been 18 working up and down and I think that has been going on for 19-years.

I think it is important that we realize where are 20 the risks and that follows the philosophy that the present 21 Commission is emphasizing in the area of risk assessment.

22 I do want to have something clear.

That is that I 23 believe that the fuel storage pool does not belong in this 24 role.

I think that that is an issue --

t 25 CHAIRMAN JACKSON:

That is going to be something ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

49 1

that the Commission will have to decide since it is in the 2

paper.

3 COMMISSIONER DIAZ:

That's correct.

That's it 4

absolutely.

And the Commission will look at it.

5 But I think we are mixing apples and grenades and 6

I don't think we should do that.

7 In the area of the overall -- in the rest of the 8

rule, I think we need to give a little bit more 9

consideration, or I will give consideration to the fact that 10 we have been trying to be less prescriptive, trying to work 11 in developing, you know, an environment in which things are 12 done because they are right and this might be going the.

13 wrong way, although it might be necessary.

I think we need 14 to put those two objectives and bring them together.

There 15 is a long history now of we, the NRC, and the industry 16 providing licensees with requirements t!Qt make the plants 17 work better.

Those requirements that you have not taken 18 into consideration, I understand the base for it, actually 19 have made nuclear power plants safer through a long history 20 of time now and, of course, we really never have a 21

" accident" or release during shutdown.

That is a major 22 issue.

23 We actually have been allowing the industry to 24 determine which systems are operable or must remain operable 25 during certain conditions and which they can actually remove ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D C. 20005 (202) 842-0034

50 1

from service.

So ue have actually been making allowance in 2

determining can you take this system-out, can you do 3

in-service inspection.

Essentially, this rule comes in and 4

restricts that area significantly as a rule rather than as a 5

voluntary process or as a process that might be really 6

required through other means which could be generate letters 7

and so forth.

8 I just want to bring up one major thing that the 9

NRC did many years ago, which is called ALARA, and which has 10 served this Commission and this Commission has used for many 11 years in assuring that we have minimal impact due to -- you 12 know, from radiation to personnel, the public and the 13 environment and that has worked well.

So I believe that we 14 should take these things into consideration as we go into 15 the rulemaking.

16 But I want to thank the staff for a wonderful job.

17 CHAIRMAN JACKSON:

I want to tuTnk you for 18 outlining your vote.

19 (Laughter.)

20 CHAIRMAN JACKSON:

Commissioner McGnffigan.

21 COMMISSIONER McGAFFIGAN:

I am actually going to 22 ask a question.

23 I would comment that your earlier answer to the 24 Chairman's question about where ooes this fall in 25 prescriptive versus performance-based space, I actually ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C. 20005 (202) 842-0034

51 1

reading the rule find it quite f ar t.oivards performance based 2

and there are things that you have done since the last time 3

in terms of alternatives to containment and it is very broad l

4 language.

The licensee shc11 minimize the frequency of 5

fires during shutdown operations.

I mean, you are not 6

telling them how to do it, you are telling them they shall 7

do it and there may be some prescription in the reg guide 8

but in looking at that continuum, I think they have made a 9

larger step than perhaps the answer indicated towards 10 performance-based rule.

11 That is in response to Commissioner Diaz.

Now, 12 let me ask my questions.

13 One thing I noticed in the package that I haven't 14 seen earlier in previous rulemaking packages is this Table 7 15 safety goal decision guidance that apparently comes from the 16 safety goal and it -- does this come up in other 17 rulemakings, just as a matter -- I am just interested 18 whether you do this matrix every time you propose a rule in 19 reactor space?

20 MR. HOLAHAN:

This, the regulatory analysis 21 guideline, core damage frequency, additional containuent 22 failure probability?

23 COMMISSIONER McGAFFIGAN:

Right.

24 MR. HOLARAN:

That is a screening criteria that is 25-used for all -- actually for all generic issue screening, i

ANN RILEY & ASSOCIATES, LTD, Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005 (202) 842-0034

53 1

both for generic letters as well as for things like 2-rulemaking, and it is built into the regulatory analysis 3

guidelines.

It is a screening step to identify which.are 4

issues that ought to move forward and then a risk analysis 5

with a, you know, cost / benefit analysis done sort of as a 6

second stage, so what Tim was showing was the second stage 7

results.

8 COMMISSIONER McGAFFIGAN:

So I should look forward 9

to seeing this in every -- in almost every package that 10 comes forward?

11 MR. HOLAHAN:

Usually, you don't see that 12 particular piece but that is the screening level.

Usually, 13 you see the second level results, 14 MR. KING:

Yes, right.

15 That piece goes to CRGR when they review rules.

16 It doesn't always show up in the statement of 17 considerations.

18 COMMISSIONER McGAFFIGAN:

Right.

19 MR. HOLAHAN:

But it has always been considered at 20 some stage in the process.

21 COMMISSIONER McGAFFIGAN:

And then we have been 22 exploring through the afternoon some of the interactions 23 between this rule and other rules.

There is a separate 24-package up to us at the moment on the famous maintenance 25 rule,_ Section A(3)_ and Alternative 3 that is of fered in that ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

53 1

package is something that would not just change the "should" 2

to "shall" --

3 MR-HOLAMAN:

Right.

4 COMMISSIONER McGAFFIGAN:

-- but address other 5

issues and it doesn't sound unreasonable if we are going to 6

move in the direction of risk-informed regulat. ion that says 7

that one of the advantages would be to provide a foundation 8

on which other risk-informed regulation could build.

But 9

among the disadvantages, it says such a rule would have 10 broad impact on other current and proposed rules including 11 the proposed shutdown rule and should thus be part of a 12 separate rulemaking that would be used for-risk-informed 13 regulation in general.

14 Can you explain that, what the impact of the 15 possible Alternative 3 for the shutdown rule would be?

16 MR. HOLAMAN:

Well, I think there is clearly an 17 interrelationship.

I am not nure I would describe it 18 entirely as negative.

From what Tim has said, you can see 19 the most important aspects of this rule have to do with 20 controlling the availability of equipment that is used to 21 mitigate events and to the extent that the maintenance rule, 22 tius A (3 ) part of the maintenance rule also addresses 23 availability of equipment, I think a strong A(3) which 24 addressed both power operation and shutdown I think could 25 accomplish that same function as the shutdcwn : nile.

t ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C.

20005

^

(202) 842-0034

54 1

Now, I think the implications are in order to do 2

that as part of the maintenance rule, you would have to 3

build some infrastructure in the sense of, well, how would 4

you use A(3), what sort of analysis would be done, does it 5

require that there would be a PRA that was reviewed and G

approved?

There are a lot of ancillary questions that we 7

are not quite ready to answer.

8 But I think that functionally there is this 9

overlap in terms of control of the availability of 10 equipment.

Likewise, I think technical specifications 11 control the availability of equipment and so there would be 12 a considerable overlap between an A(3) and the current 13 technical specifications.

So I think it is a powerful 14 thought but it has a lot of implications to be sorted out.

15 CHAIRMAN JACV. SON:

Thank you.

16 MR. HOLARAN:

Thank you.

17 MR. CALLAN:

Chairman, I would like to just make 18 one comment at the end.

19 You know, a-common theme in this presentation is 20 the Staff's view that there is a problem with our 21 regulations that needs to be addressed and that the safety 22 not that our regulations provide for shutdown operations is 23 not sufficient.

That in the baseline.

What the staff is 24 not saying is there is a compelling need in terms of 25 licensing performance for a rulemaking.

You know, my view, ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W., Suite 300 Washington, D.C. 20005

-(202) 842-0034

55 1

and somewnat anecdotally, is that the performance of the 2

industry-is actually better than the NUMARC 91.06 3

guidelines.

I mean, the: region I just left, I would say at 4

least half of the licensees in that region have something 5

equivalent to a shutdown risk meter concept with a very 6

sophisticated war room during outages where risk is tracked 7

almost hour by hour, without exaggerating.

As equipment is 8

taken out of commission, the range of options are reviewed 9

and adjustments are made daily.

Quite sophisticated control 10 of risks during outages.

11 So in terms of licensee performance, there isn't a-12 compelling argument.

But none of that I shouldn't say 13 none of that -- very little of that falls within the 14 regulatory framework and that is the issue here.

15 MR. HOLAHAN:

Absolutely.

I agree.

And one of 1 61 the things we have done in these last six-months is 17 recognized that-I'think in the past we were in danger of 18 writing a rule-that would have been at odds with even the 19

'better licensee programs.

-It would have required them to 20-keep some set of. books on technical specifications and maybe 21 even distract-them from their risk management approach.

So 22 I think what we-have constructed here-is a rule which could, 23 in effect, adopt and bless a. program that Mr..

Callan has 24 described.

They wouldn't necesstrily have to change that 25 program.

It would simply draw it through the reference from ANN RILEY'& ASSOCIATES, LTD.

Court Reporters 1250-I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 84?-0034

56 1

an administrative technical specification.

It would become 2

the licensee's commitment to continue to carry out that 3

program.

I think that is a way of taking advantage of the 4

best features of an existing program.

5 CHAIRMAN JACKSON:

Yes.

6 COMMISSIONER DIAZ:

Are you convinced that none of 7

our requirements, even if they are old, have captured this 8

or have we actually forgotten to use them?

Because, you 9

know, there are some that actually I could pick out from the 10 book that might address this and not very long ago we 11 actually put out a new one.

12 CHAIRMAN JACKSON:

Okay, lot him answer, 13 COMMISSIONER DIAZ:

I was still talking.

I wasn't 14 finished.

15 So, you know, when you look at it, okay, and you 16 look at what we just did with PRA and you look at sorne of-17 the things, my question always goes back to the definition 18 that we use in the book of any normal operating condition 19 and it might have been captured.

I just want to be sure it 20 was not captured someplace else.

21 MR. HOLAHAN:

Okay.

22 What I am convinced of is the Atomic Energy Act 23 covers shutdown operations.

So the Agency has the power to 24 regulate it.

There are other-areas where the regulation 25 either suggests or could be interpreted to cover shutdown ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 l

(202) 842-0034

--~-

l

o 57 1

but it is not clear and it is certainly not the current 2

staff and industry practice to interpret the regulation that 3

way.

So part of what we would be doing here is, remember, 4

the original objective is to become clearer on what the 5

requirements Ere.

6 COMMISSIONER DIAZ:

All r!.ght, thank you.

7 CHAIRMAN JACKSON:

I would like to thank the staff 8

for a very informative briefing today and it is clear from 9

the quality of the briefing that you and the rest of the 10 staff that have been associated with this project have spent 11 many long hours of thought and consideration on this.

And 12 as the overall safety and reliability of nuclear power 13 reactors does generally continue to improve but pressures to 14 improve economic performance continue, it is imperative as 15 you have outlined here that if, where necessary to ensure 16 protection of public health and safety and that operating 17 and safety margins are maintained, that we promulgate 18 regulations that are as risk informed and performance based 19 as they can be.

't 20 I think it is interesting, coming out of this 21 discussion, for the staff to review as it is involved in 22 resolving either other generic issues or other rulemakings, 23 to review the extent to which voluntary licensee action is 24

. relied upon and where, if regulatory action is warranted, 25 that it is not something that takes the licensee -- takes us ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034 1

i I

58 1

away from where that can satisfy what our needs are.

I 2-If there is nothing more,-we are adjourned.

3

[Whereupon, at 3:18 p.m.,

the briefing was 4

concluded.]

5 6

7 8

9 10 11 12 13

.14 15 16-17-

-18 19 20

-21 22 23 24 25 ANN RILEY & ASSOCIATES, LTD.

Court Reporters 1250 I Street, N.W.,

Suite 300 Washington, D.C.

20005 (202) 842-0034

1 0

CERTIFICATE This is to certify that the attached description of a meeting of the U.S. Nuclear Regulatory Commission entitled:

TITLE OF MEETING:

BRIEFING ON SHUTDOWN RISK PROPOSED RULE FOR NUCLEAR POWER PLANTS PUBLIC MEETING PLACE OF MEETING:

Rockville, Maryland DATE OF MEETING:

Wednesday, August 6, 1997 was held as herein appears, is a true and accurate record of the meeting, and that this is the original transcript thereof taken stenographically by me, thereafter reduced to typewriting by me or under the direction of the court reporting company.

I U 1 4 %, l a d u., -.

Transcriber:

Reporter:

Mark Mahoney

gn reg G

4 4p

~

~

%++*

DEVELOPMENT OF 950.67 SHUTDOWN AND FUEL STORAGE POOL OPERATIONS AT NUCLEAR POWER PLANTS August 6,1997 Timothy Collins 301-415-2897

OUTLINE OF PRESENTATION p

e Objective and Background e Need for Rulemaking -

Risk Significant issues e Structure of Proposed Rule e Regulatory Analysis Results i

e Risk-Informed Principles in New Proposed Rule e Changes in Proposed Rule Since 1994When Last Published e Schedule i

l 2

i j

)l l!!

l 1

EL U

ede R

am g

r r

D oo E

dt f e

snl l

b S

ol i

c e k-a O

use r

f i c

P o

r f

d r

eo O

sn r f t

aan R

n e

P egt ad minh n

F el t

a r

e s

O u

nt iuf n

qeo e

E er,t i

r V

nr h r

ae e

I nweopo T

c i

C ed r,

f o

E d

uoa t

l e

J oh ol B

T spc O

f b

1

BACKGROUND e October 1994 - Proposed Rule Published e 1023 Public Comments on 1994 Proposed Rule e August 1995 - PRA Policy Statement Published e Discussion with ACRS May 21,1996 e 1996 - Public Meetings e ACRS letter of April 18,1997 recommended Benchmark Study on Risk During low-Power and Shutdown Operations e July 1997 - Proposed Rule Forwarded to Commission 4

l RISK SIGNIFICANT ISSUES e Decay Heat Removal e inventory Control e Protection Against Fission Product Release l

e Reactivity Control e Pressure Control e Operator Performance Protected by 10 CFR Part 50 Appendix B &

Technical Specifications when at Power 5

MGMPM l

l RISK SIGNIFICANT ISSUES-l DURING SHUTDOWN SOME ISSUES NOT COVERED BY EXISTING REQUIREMENTS l

e Availability of ECCS for PWRs 1

e Availability of BWR venting to permit makeup j

Availability of Containment l

e l

SOME ISSUES NOT FULLY ADDRESSED BY EXISTING l

REQUIREMENTS e

Fire Protection for Cold Shutdown Equipment i

BWR fire protection for equipment in containment I

e (no inerting)

App B (Procedures, Corrective Actions and QA) for e

Cold Shutdown i

l 6

i ASSESSMENT OF CURRENT REGULATORY REQUIREMENTS USING PRA (Excludes Fire)

Frequency of Core Damage Frequency Unmitigated Release events / reactor-year per reactor-year PWR BWR PWR BWR Estimate of Industry 8E-5 1 E-5 2E-5 8E-6 Practice per NUMARC to to to to 91-06 (VoluntaryCase):

2E-6 6E-7 2E-7 6E-7 Potential Regulatory 2E-2 1E-3 2E-2 1 E-3 Minimum (Base Case):

l l

1 l

l 950.67 SHUTDOWN AND FUEL STORAGE POOL OPERATIONS Rule Outline Procedural Element Admin Tech Specs 950.67(a)(1)

-Procedures

-Quality Assurance

-Training

-Corrective Action Performance Monitoring Tech Specs 950.67(a)(2)

-Safety Function Limits Mitigation CapabilityTech Specs 950.67(a)(3)

-Backup RHR

-Injection

-Containment or Alternative Fire Protection 950.67(a)(4)

Fuel Storage Pool 950.67(b) 8

3 SHUTDOWN OPERATIONS Regulatory Analysis Results (fire not included)

Frequency of Core Damage Frequency.

Unmitigated Release events / reactor-year per reactor-year PWR BWR PWR BWR I

Estimate of Industry BE-5 1 E-5 2E-5 8E-6 Practice per NUMARC to to to to 91-06 (VoluntaryCase):

2E-6 6E-7 2E-7 6E-7 Potential Regulatory 2E-2 1E-3 2E-2 1 E-3 Minimum (Base Case):

8E-5 8E-6 1E4 4E-6 R

re ents

= = ' -,

ue se):

fgf 1E-5 4E-6 1 E-6 4E-6 g y) 9 l

.S FIRE PROTECTION FOR SHUTDOWN MODES OF OPERATION e Risk Factors Assessed in Regulatory Analysis Frequency of fires during shutdown operations a

Probability of sufficient combustible loadings to a

allow fire to propagate Probability of fire barriers being removed or a

degraded Probability fire detection and/or suppression a

systems would be unavailable Probability of failure to recover from a loss of a

decay heat removal i

10

^

INDUSTRY COSTS (Base Case to Rule Case)

(Present value per plant over its remaining life)

SHUTDOWN OPERATION w/

$ 1'8 M FIRE PROTECTION FIRE PROTECTION

$1 M

FUEL STORAGE

$.05 M POOL OPERATION TOTAL (per plant)

$ 2.85 M l

11

...a-.

RISK-INFORMED PRINCIPLES IN RULE DEVELOPMENT e PRA technology used to the extent supported by the state-of-the art, e Maintain Defense in Depth Philosophy e Realistic Assumptions Used in Analysis e Treatment of Uncertainties -

Qualitative Assessment e Safety Goals Subsidiary Objectives Considered i

12 c

~

s CHANGES IN PROPOSED RULE SINCE 1994 e Hot Shutdown / Low Power Modes No Longerincluded e Alternatives to Containment Permitted e Less Use of Single Failure Criterion e Licensee to Set Performance Monitoring Parameter Limits e Fuel Storage Pool Documentation Addressed e BetterValue/ Impact Analysis More Flexible and RiskInformed 13

l SCHEDULE ITEM DATE COMMISSION APPROVAL 8/29/97 9/1/97 PUBLISH PROPOSED RULE PUBLIC COMMENT 12/1/97 ACRS MEETING 4/98 CRGR MEETING 5/98 COMMISSION APPROVAL 8/98 PUBLISH FINAL RULE 8/98 14

- - -