Forwards IE Inspec Rept 50-313/78-14 on 780814-18 & Notice of Violation
ML20197C508
Person / Time
Site: Arkansas Nuclear 
Issue date: 09/14/1978
From: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Cavanaugh W
ARKANSAS POWER & LIGHT CO.
Shared Package
ML20197C512 List:
References
NUDOCS 7811210114
Download: ML20197C508 (2)


See also: IR 05000313/1978014

Text

, , , , -

- " - ~ ~ ~ ~

s

,

.

.

u

o RFoo

UNITED ST ATES

NUCLE AR REGULATORY COMMISSION

hg

[

REGION IV

p

$ .,

. $

611 RYAN PLAZA DRIVE, SUITE 1000

  • $

' *

AR LINGTON, TE X AS 76011

k .m /

..+

September 14, 1978

Docket No.

50-313

Arkansas Power and Light Company

ATTN: Mr. William Cavanaugh III

Executive Director of Generation

and Construction

Post Office Box 551

Little Rock, Arkansas

72203

Gentlemen:

This refers to the inspection conducted by Blaine Murray of this office

during August 14-18, 1978, of activities authorized by NRC Operating

License No. DPR-51 and to the discussion of the inspection findings held

by Mr. Murray with G. H. Miller and other members of your staff at the

conclusion of the inspection on August 18, 1978.

Areas examined during the inspection and our findings are discussed in the

enclosed inspection report. Within these areas, the inspection consisted

of selective examination of procedures and representative records, inter-

views with personrel, and observations by the inspectors.

Based on the results of the inspection, it appears that certain of your

activities were not conducted in full compliance with NRC requirements.

The items and references to the pertinent requirements are listed in

Enclosure 1 to this letter.

This letter constitutes a notice sent to you pursuant to the provisions

of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code

of Federal Regulations.

Section 2.201 requires you to submit to this

office within twenty (20) days of your receipt of this notice, a written

statement or explanation in reply including:

(1)correctiveste

have been or will be taken by you, and the results achieved; (2)ps which

corrective

steps which will be taken to avoid further violations; and (3) the date

when full compliance will be achieved.

In accordance with Section 2.790 of the NRC " Rules of Practice," Part 2,

Title 10, Code of Federal Regulations a copy of this letter and the

enclosed inspection report will be placed in the NRC's Public Document

Room.

If this report contains any information that you believe to be

proprietary, it is necessary that you make a written application within

twenty (20) days to this office to withhold such information from public

disclosura. Any such application must include a full statement of the

reasons it is claimed that the information is proprietary.

It should be

?S1121o \\ \\ %

- - - - - - - -

..

.

Arkansas Power and Light Company

-2-

September 14, 1978

prepared so that proprietary information identified is contained in a

separate part of the document, since the application, excluding this

separate part, will also be placed in the Public Document Room.

If we

do not hear from you in this regard within the specified period, the

report will be placed in the Public Document Room.

,

Should you have any questions concerning this inspection, we will be

pleased to discuss them with you.

Sincerely,

}l<chaa

c

,G. L. Madsen, Chief

Reactor Operations and

Nuclear Support Branch

Enclosures:

1.

Notice of Violation

2.

IE Inspection Report No.

50-313/78-14

l

l

1

-

- _ - - - - - _ - - - - - - - _ - -