ML20197B700
| ML20197B700 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 10/27/1986 |
| From: | Travers W Office of Nuclear Reactor Regulation |
| To: | Harold Denton, Miraglia F Office of Nuclear Reactor Regulation |
| References | |
| CON-NRC-TMI-86-104 NUDOCS 8610300379 | |
| Download: ML20197B700 (3) | |
Text
y w
(w 9
October 27, 1986 NRC/Tlil-86-104
- 1. m
[-
HEMORANDUM FOR:
Harold R. Denton, Director a
Office of Nuclear Reactor Regulation Frank J. Miraglia, Director g
Division of PWR Licensing-B C
FROM:
William D. Travers, Director Tl11-2 Cleanup Project Directorate
SUBJECT:
URC THI-2 CLEANUP PROJECT DIRECTORATE WEEKLY STATUS REPORT FOR OCTOBER 20 - 26, 1986 1.
DEFUELING The core drilling rig successfully drilled a test pattern of 19 holes through the crust at the top of the remaining core material.
The loose material from the drilling operation was readily removed from the test area using existing tooling (i.e., heavy duty spade bucket). A drilling test on intact fuel area has been started (3 of the 19 holes) pins in the test pattern Production drilling near the core center line has also begun.
Startup and test operations continue on the Defueling Water Cleanup System (DNCS) ion exchange system. Use of the ion exchangers in conjunction with the DWCS filters will aid in maintaining reactor coolant system water clarity and will reduce the activity levels of u.
the coolant.
2.
ENVIRONMENTAL !!0NITORING US Environa2ntal Protection Agency (EPA) sample analysis results show that THI site liquid effluents are in accordance with regulatory limits. HRC requirements, and The City of Lancaster Agreement.
The Lancaster water senple taken at the water works river intake and
's analyzed by EPA consisted of a seven day composite sample taken 7
October 5 - 11, 1986. A gacna scan detected no reactor related f.-
activity.
THI water samples taken by EPA at the plant discharge (includes Units 1 and 2) to the river consisted of seven daily conposite sampics taken from October 4 - 11, 1986. A garna scan detected no reactor related activity.
h03 79 861027
- ~-
R CK 050003y9 am,y PDR y
ff sunwassah
^
yt NRC FORM SIS (10-80) NRCM 0240 OFFICIAL RECORD COPY
e Harold R. Denton 2
October 27, 1985 Frank J. Mira911a ImC/T!!I-C6-104 The EPA enalyses of tria URC outdoor air sample for the period October 16-23, 1906 showed that concentrations of Cs-137 and I-131 were belev the 1cuer limit of quantitative detection (LLD) for the sys tem. The LLD varies around a value of IE-13 uCi/cc.
3.
AUXILIARY Ni9 FUEL HAllDLING UUILDIf G ACTIVITIES Startup and test of the DUCS ion exchangers cor,tinues.
4.
NPC EV/d.UATI0HS Iil PROGR _ESS Technical Specification Changa Request numbers 49, 51, Ei, and 54.
Recovery Operations Plan Change nu@ers 31 and 33.
Solid Waste Facility Technical Evalation Report.
lleavy Lead Sofety Evaluation Report, Revision 3.
Disposal of Pr. cessed Water Report.
SER f or Use of Plasru Arc Cutting Torch.
5.
i'EETIUCS The next ueeting of the Advisory Panel is tentatively scheduled for Ducenber 10, 1986. At that nceting the licensee will give a presentation on their licensing subaittal for the Post Defueling Plant Status. That submittal is scheduled for issue to the fiRC staff in fiovmber.
Persons desiring to speak before tua Advisory Panel era requested to contact fir. Thems Snithgall at 717-291-104E, or write him at 21?2 iarietta Avenue, Lencaster, PA 17603.
Dr. Travers will give a presentation on the status of the THI-2 cleanup project to the iMC Region IV stcff at the Resident Inspector Ccunterpart rueting f ra Arlingten, Texas, oa' October 23, 1956, oitlGINAE SIGPED BL Wimam D. Trwers Hillium D. Travers Director Ti1I-2 Cleanup Prof.ct Directorate
"'ce y euanaw >
Y l Nnc ronu ais no soi uncu 02d OFFICIAL RECORD COPY j
er Harold R. Denton 3
October 27, 19f36 Frank J. !! ira 911a
/
flRC/Ti1I-86-104 f
IliTERfML DISTRIBUTI0ff YEITTF</il7lLE ffRC PDR LOCAL PDR EDO OGC EPA DOE RI RLgional Administrator RI Division Directors Public Affairs, RI State Liaison, RI TIil liq r/f Till SITE r/f Till-2 Project Section File TMI-1 Resident Office (5)
Tl!I Cleanup Project Directorate (14) r OF FICE > TM P,,,,,
4JCPpg,(7,
- JMJCPD,
,JMJC Ch QRNAME> JT as:Jes.. CCowg.i].l.....hct
.WT q
e Suppb'tr
^"> 10/D/86.....10/N86.... 10/.
86.....
10 3 86....
OFFICIAL RECDRD COPY I RRC FORM 318 (1080s NRCM O240
- - -..