ru r-

  • N ENCLOSURE 1 NOTICE OF VIOLATION Georgia Power Company Docket Nos. 50-321 and 50-366 Hatch License Nos. DPR-57 and NPF-5 The following violation was identified during an inspection conducted on March 24-27, 1986.

The Severity Level was assigned in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C).

Technical Specification 6.8.1.c requires that procedures be implemented for surveillance and test activities of safety-related equipment.

10 CFR 50.55a(g)(4) requires that throughout the service life of a nuclear power plant, Class 1, 2, and 3 components shall meet the requirements of the Edition of ASME Section XI that becomes effective.

The applicable Edition

' of ASME Section XI, the 1980 Edition, requires pressure testing and VT-2 inspection of certain Class 2 and 3 systems each 40 months.

Contrary to the above, implementing procedures for scheduling and tracking pressure tests do not exist and Class 2 and 3 40-month pressure tests are not being scheduled and performed.

This is a Severity Level IV violation (Supplement I).

Pursuant to 10 CFR 2.201, you are required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, including:

(1) admission or denial of the alleged violation; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

Security or safeguards information should be submitted as an enclosure to facilitate withholding it from public disclosure as required by 10 CFR 2.790(d) or 10 CFR 73.21.

N Date:

8605120470 860430 DR ADOCK 0500 1