Text

. _.

D siso.mu,0mm de EDISON

?==""

An EDISON INTERNATIONAL" Company U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 i

Gentlemen:

Subject:

i)ocket Nos. 50-361 and 50-362 Corrected Amendment Application Nos. 183 and 169 Pressurizer Safety Valve Setpoints San Onofre Nuclear Generating Station Units 2 and 3

Reference:

September 4,1998 letter from Dwight E. Nunn (SCE) to Document Control Desk (NRC),

Subject:

Docket Nos. 50-361 and 50-362, Amendment Application Nos.180 and 166, Pressurizer Safety Val'e Setpoints, San Onofre Nuclear Generating Station Units 2 and 3 Enclosed is a revision to Amendment Application Nos.183 and 169 to Facility Operating Licenses NPF-10 and NPF-15, for the San Onofre Nuclear Generating Station (SONGS), Units 2 and 3, respectively.

These amendment applications

)t were incorrectly identified as Ar.endment Application Nos. 180 and 166 in the above reference. These amendment applications consist of Proposed Change Number 493 (PCN-493).

i PCN-493 is a request to revise Technical Specification 3.4.10, " Pressurizer Safety Valves," Limiting Condition for Operation (LCO) by increasing the as found Pressurizer Safety Valve (PSV) setpoint tolerances.

(J[

The enclosed revision provides the following:

1)

Corrected amendment pleading pages.

2)

Revised responses to questions one and two of the "No Significant Hazards Consideration" for completeness, and 3)

Revised Description for PCN-493 to recover some text which was inadvertently deleted by a format error.

s9/

n

-n 9812090265 G 200 PDR ADOCK G"AOO361 P

PDR

[

P. O. Box 128 San Clnnente, CA 92674-0128 949-368-1480 l

Fax 949-368-1490

~!

l j

l Document Control Desk.

If-you need additional information or have any questions regarding this i

proposed Technical Specification change, please let me know.

i I

1 Sincerely, I

Q 'pSt.)w i

1 Enclosures I

cc:

E. W. Merschoff, Regional Administrator, NRC Region IV J. A. Sloan, NRC Senior Resident Inspector, San Onofre Units 2 & 3 J. W. Clifford, NRC Project Manager, San Onofre Units 2 and 3 1

\\

i 1

i j

ENCLOSURES

1. CORRECTED PLEADING PAGES i
2. CORRECTED DESCRIPTION AND REVISED NO SIGNIFICANT IIAZARDS CONSIDERATION PAGES PROPOSED CilANGE NPF-10/15-493 PRESSURIZER SAFETY VALVE SETPOINTS SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3 (Changes are identified with a change bar in the right margin)