ML20196E800

From kanterella
Jump to navigation Jump to search
Errata to Amend 92 to License NPF-7,changing Ref from Third Test to Second Test & Deleting Ref to 10-yr ISI Outage in Footnote
ML20196E800
Person / Time
Site: North Anna Dominion icon.png
Issue date: 12/06/1988
From:
NRC
To:
Shared Package
ML20196E761 List:
References
NUDOCS 8812120088
Download: ML20196E800 (3)


Text

. . .

3/4.6 CONTAINIENT SYSTEMS 3/4.6.1 CONTAIPGsENT CONTAINMENT INTEGRITY LIMITING CON 0! TION FOR OPERATION 3.6.1.1 Primary CONTAINMENT INTEGRITY shall be maintained.

APPLICA8!LITY: MODES 1, 2, 3 and 4.

ACTION:

Without primary CONTAINNT INTEGRITY, restore CONTA!*ENT INTEGRITY within one hour or be in at least HOT STAN08Y within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS

'=

1 4.6.1.1 Primary CONTAINMENT INTEGRITY shall be demonstrated:

a. At least once per 31 days by verifying that all penetrations
  • not capable of being closed by OPERABLE containment automatic isolation valves and required to be closed durIr.g accident conditions are closed by valves, blind flanges, or deactivated automatic valves secured in their positions, except as provided in Table 3.6-1 of Specification 3.6.3.1., and
b. By verifying that each containment air lock is OPERA 8LE par Specification 3.6.1.3.
c. After each closing of the equipment hatch, by leak rate testing the equipment hatch seals with gas at Pa, greater than or equal to 40.6 psig, and verifying that when the seasured leakage rate for these seals is added to the leakage rates determined pursuant to Specification 4.6. l.2.d for all other Type 8 and C perntrations, the combined leakage rate is less than or equal to 0.60 La.

l "Except valves, blind flanges and deactiviated automatic valves which ,

are located inside the containment and are locked sealed or otherwise sealed in the closed position. These penetrations shall be verified closed during each COLD SHUTDOW except that such verification need not be performed more often than once per 92 days.

3 G3121200so estrog

{DR ADOCN 05000j39 m

NORTH ANNA - UNIT 2 3/4 6-1 i

CONTAINMENT SYSTEMS CCNTAINMENT LEAKAGE LIMfifNG CONDITION FOR ODE 7ATION 3.6.1.2 Containment leakage rates shall be limited to:

a. An overall integrated leakage rate of:
1. Less than or equal to L containment air per 24 houfs, at 0.1 percent by weight of the 40.6 psig, or P,, greater than or equal to
b. A combined leakage rate of less than or equal to 0.60 L f penetrations and valves subject to Type 8 and C tehs,orwhen all pressurized to P,, greater than or equal to 40.6 psig.

APPLICABILITY: MODES 1, 2, 3 and 4 A.lllQ3:

With either0.75 exceeding (a) Lthe measured overall integrated containment leakage rate or (b) with the measured combined leakage rate for all penetrations and "valves subject to Type B and C tests exceeding 0.60 L ,

restore the overall integrated leakage rate to less than 0.75 t,a and t$e combined leakage rate for all penetrations subject to Type 8 and C tests to less than orabove temperature equal200'F.. to 0.60 L, prior to increasing the Reactor Coolant System SURVEILLANCE REOUIREMENTS 4.6.1.2 The containment leakage rates shall be demonstrated at the following test schedule and shall be determined in conformance with the criteria specified in Appendix J of 10 CFR 50 using the methods and provisions of ANSI N45.4 1972
a. Three Type A tests (0verall Integrated Containment Leakage Rate) shall be conducted at 40 $ 10 month intervals during shutdown at P greater period.

than or equal to 40.6 psig, during each 10 year servici The third test of each set shall be conducted during the shutdown for the 10 year plant inservice inspection.*

l

  • The second test of the first 10 year service period shall be conducted during the 1989 Refueling Outage.

i i

NORTH ANNA UNIT 2 3/4 6 2 Amendment No. 92

.-. -. . . . - - - ~ - _ . , _ - . - - _ _ _ - . - - _ - - - . - - - - _ -

DAIED: December 6. 1988 >

CORRECTION TO AMENDMENT NO. 92 TO FACILITY OPERATING LICENSE NO. NPF-7 ISSUED NOVEMBER 10, 1988 ,

Rs PDII-2 Reading ,

S. Varga, 14/E/4  ;

G. Lainas, 14/H/3 '

H. Berkow I D. Miller  !

L. Engle <

OGC-WF D. Hagan, 3302 MNBB E. Jordan, 3302 MNBB B. Grimes, 9/A/2 T. Meek (4), P1-137 i Wanda Jones, P-130A l E. Butcher i ACRS (10) , 11/F/23 GPA/PA ARM /LFHB

(

cc: Plant Service list i

i t

l I

f l

I L

r I

I t

w. _ _ -