57 F RAMATOM E COG EMA F U E LS l
1 August 31,1998 l
Director, Radiation Safety & Safeguards Region II United States Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth Street SW Suite 23T85 Atlanta,GA 30303
Reference:
SNM-1168, Docket 70-1201 Gentlemen:
In accordance with the provisions of 10CFR70.59, Framatome Cogema Fuels submits the enclosed Gaseous Effluent Report for the first semi-annual period of 1998 for the Lynchburg Manufacturing Facility site located in Lynchburg, Virginia.
You may contact me at (804)832-5202 should you have any questions or require additional information concerning the enclosed report.
Sincerely,
/
0 'le F. Elliott Manager, Safety & Licensing Enclosure ec:
Ms. Elizabeth Q. Ten Eyck, Director i
Division of Fuel Cycle Safety & Safeguards i
Office of Nuclear Material Safety & Safeguards J
l United States Nuclear Regulatory Commission Washington, D.C. 20555 i
Mr. Thomas W. Stone, Jr.
Department of Health Bureau ofIndustrial Hygiene 109 Governor Street Richmond,VA 23219
)
9812020159 980630 (
PDR ADOCK 070012014 C
PDRL1 YFRAMATOME EIH Frematome Cogoma Fuels RO. Box 11646, Lynchburg. VA 24506-1646 7ECHHOL0GIES Telephone:804-832-5000 Fax: 804 832-5167 1
gE07
a, t
8/31/98 Pag 31 of 2 Gaseous Effluent Report I
01/01/98 to 06/30/98 Sample Cot!ection Point:
Main Plant Stack Volume Released:
2.53E+09 cubic feet Stack Flow Rate (typical):
10000 cubic feet per minute Activity Released Gross Alpha:
2.329 uCi Gross Beta:
13.192 uCi Isotope Activity Concentration
% DAC (uCi)
(uCl/ml)
U-234 1.81 2.52E-14 50.497 U-235 1.01 E-01 1.41 E-15 2.34 U-236 8.17E-04 1.14E-17 0.01 U-238 4.21E-01 5.86E-15 9.77 Co-60 13.192 1.84E-13 0.36
- 2. SERF-2 RCA Reporting Period:
01/01/98 to 06/30/98 Sample Collection Point:
Main Plant Stack Volume Released:
1.89E+08 cubic feet Stack Flow Rate (typical):
738 cubic feet per minute I
Activity Released Gross Alpha:
0.000 uCi Gross Beta:
0.919 uCi l
isotope Activity Concentration
% DAC (uCi)
(uCi/ml)
Co-60 0.919 1.72E-13 0.34
- 3. SERF 3 RCA Reporting Period:
01/01/98 to 06/30/98 Sample Collection Point:
Main Plant Stack Volume Released:
1.13E+09 cubic feet Stack Flow Rate (typical):
4862 cubic feet per minute Activity Released Gross Alpha:
0.000 uCi Gross Beta:
8.771 uCi Isotope Activity Concentration
- % DAC (uCi)
(uCi/ml)
Co-60 8.771 2.74E 13 0.55
8/31/98 Page 2 of 2
- 4. SERF-4 RCA Reporting Period:
01/01/98 to 06/30/98 Sample Collection Point:
Main Plant Stack Volume Released:
2.60E+09 cubic feet Stack Flow Rate (typical):
10000 cubic feet per minute Activity Released Gross Alpha:
0.000 uCi Gross Beta:
28.632 uCi Isotope Activity Concentration
% DAC (uCi)
(uCl/ml)
Co-60 28.632 3.89E-13 0.78 1
l l
L
.