1 t'-

I June 2, 1999 d

i

^ Mr. Harold B. Ray Executive Vice President Southem Califomia Edison Company San Onofre Nuclear Generating Station P. O.~ Box 128 -

~ San Clemente, CA 92674-0128

SUBJECT:

SAN ONOFRE NUCLEAR GENERATING STATIONS, UNITS 2 AND 3 -

EVALUATION OF RELOAD ANALYSIS METHODOLOGY TECHNOLOGY TRANSFER (TAC NOS. MA4289 AND MA4290)

Dear Mr. Ray:

By letter dated November.30,1998, as supplemented December 31,1998, and March' 1,1999, you submitted Topical Report SCE-9801-P, " Reload Analysis Methodology for the San Onofre Nuclear Generating Station Units 2 and 3," for review. Based on a review of Southem Califomia Edison's topical reports and on an onsite audit of the impMmentation of the Reload Technology Transfer Program, the staff has concluded that Southem Califomia Edison has the capability to perform reload design and non-loss-of-coolant accident analyses for the San Onofre Nuclear Generating Station Units 2 and 3. Our evaluation is enclosed.

I'f you have any questions, please contact the San Onofre Project Manager, L. Raghavan, at (301) 415-1471. This completes our efforts on TAC Nos. MA4289 and MA4290.

Sincerely,

/s/.

A Stephen Dembok, Chief, Section 2 kTD[

1 Project Directorate IV and_ Decommissioning 9906090108 990602 L Division of Licensing Project Management DR ADOCK 0 1

Office of Nuclear Reactor Regulation i

Docket Nos. 50-361 and 50-362 Enclosuto: Evaluation t

cc w/ encl: See next page DISTRIBUTION Docket File OGC -

% wwp PUBLIC" ACRS' gg PDIV-2 Reading Alevin LRaghavan LSmith, RGN-IV L%bv=

CJamerson OFFICE PDIV-2/PM PDIV-3/LA kkXB/B PDIV-2/SC NAME LRachavan:rt CJamersonkhf b

SDemb 9 [9 /99 I/[g/99 DATE' f M /99 s /28 /99 OFFICIAL RECORD COPY

/

DOCUMENT NAME: G:\\PDIV-2\\ SONGS \\LTR4289.WPD

muere p

1 UNITED STATES

-3

}

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 30006 0001 k.....

June 2, 1999 Mr. Harold B. Ray Executive Vice President Southem Califomia Edison Company San Onofre Nuclear Generating Station P. O. Box 128 San Clemente, CA 92674-0128

SUBJECT:

SAN ONOFRE NUCLEAR GENERATING STATIONS, UNITS 2 AND 3 -

EVALUATION OF RELOAD ANALYSIS METHODOLOGY TECHNOLOGY TRANSFER (TAC NOS. MA4289 AND MA4290)

Dear Mr. Ray:

By letter dated November 30,1998, as supplemented Decomiar 31,1998, and March 1,1999,

._ you submitted Topical Report SCE-9801-P, " Reload Analysis Methodology for the San Onofre Nuclear Generating Station Units 2 and 3," for review. Based on a review of Southem Califomia Edison's topical reports and on an onsite audit of the implementation of the Reload Technology Transfer Program, the staff has concluded that Southem Califomia Edison has the capability to perform reload design and non-loss-of-coolant accident analyses for the San Onofre Nuclear Generating Station Units 2 and 3. Our evaluation is enclosed.

If you have any questions, please contact the San Onofre Project Manager, L. Raghavan, at (301) 415-1471.. This completes our efforts on TAC Nos. MA4289 and MA4290.

Sincerely, Stephen Dembok, Chie, ection 2 Project Directorate IV and Decommissioning

' Division of Licensing Project Management Office of Nuclear Reactor Regulation -

Docket Nos. 50-361 and 50-362 I

Enclosure:

Evaluation

.cc w/ encl: See next page l

i 1

. m.

San Onofre Nucleaf Generating Station, Units 2 and 3 cc:

Mr. R. W. Krieger, Vice President Resident inspector / San Onofre NPS Southem Califomia Edison Company, clo U.S. Nuclear Regulatory Commission San Onofre Nuclear Generating Station Post Office Box 4329 P. O. Box 128 San Clemente, CA 92674 San Clemente, CA 92674-0128 Mayor '

Chairman, Board of Supervisors City of San Clemente

. County of San Diego 100 Avenida Presidio 1600 Pacific Highway, Room 335 San Clemente, CA 92672 San Diego, CA 92101 Mr. Dwight E. Nunn, Vice President Alan R. Watts, Esq.

Southem Califomia Edison Company Woodruff, Spradlin & Smart San Onofre Nuclear Generating Station 701 S. Parker St. No. 7000 P.O. Box 128

- Orange, CA 92668-4702-

- San Clemente, CA 92674-0128 Mr. Sherwin Harris.

Resource Project Manager Public Utilities Department City of Riverside 1

3900 Main Street i

Riverside, CA-92522 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavilion 611 Ryan Plaza Drive, Suite 400 Ariington, TX 76011-8064 Mr. Michael Olson San Onofre Liaison San Diego Gas & Electric Company P.O. Box 1831 San Diego, CA 92112-4150 Mr.' Steve Hsu Radiologic Health Branch State Department of Health Services Post Office Box 942732

' Sacramento, CA 94234 wm