ML20155G636

From kanterella
Jump to navigation Jump to search
Forwards 1987 Inservice Insp Results for Steam Generator 2 & Reanalysis of 1984 Eddy Current Data for Steam Generators 3 & 4
ML20155G636
Person / Time
Site: Yankee Rowe
Issue date: 06/07/1988
From: Papanic G
YANKEE ATOMIC ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20155G640 List:
References
FYR-88-80, NUDOCS 8806200038
Download: ML20155G636 (1)


Text

'

' 'l Tsfephone (617) 872-8100 TWX 710-380 7619 YANKEE ATOMIC ELECTRIC COMPANY

/

y 1671 Worcester Road, Framingham, Massachuset's 01701

, M.

June 7, 1988 FYR 88-80 United States Nuclear Regulatory

, mission Document Control Desk Washington, DC 20555

Reference:

(a) License No. DPR-3 (Docket No. 50 29)

Subject:

Steam Generator Inspection Results

Dear Sir:

The attached reports submit the 1987 inservice inspection results for Steam Generator No. 2 and the reanalysis of the 1984 Eddy Current Data for Steam Generators Nos. 3 and 4.

The 1987 inspection was performed in accordance with Technical Specification 4.4.10.2, If you have any questions, or require additional information, please contact us.

Very truly yours, YANKEE ATOMIC ELECTRIC ~0MPANY Georg Papanic, r.

Senior Prcject Engineer Licensing GP/25.641 Attachment cc: USNRC Region I USNRC Resident Inspector, YNPS 8806200039 880607 PDR ADOCK 05000029 O

DCD