Forwards Supplemental Response to Detail Completion of Compensatory Measures Per 880420 Commitment Re Violations Noted in Insp Repts 50-327/87-73 & 50-328/87-73
ML20155B558
Person / Time
Site: Sequoyah  
Issue date: 06/06/1988
From: Gridley R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8806130230
Download: ML20155B558 (5)


Text

_ _ _ _ _ _ _ - _ _ _ _ _ _ _ _,

I TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 37401 SN 157B Lookout Place QUN 061988 U.S. Nuclear Regulatory Commission ATTN:

Docurient Control Desk Hashington, D.C.

20555 Gentlemen:

In the Matter of

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 SEQUOYAH NLCLEAR PLANT (SQN) - NRC INSPECTION REPORT NOS. 50-327/87-73 AND 50-328/87 SUPPLEMENTAL RESPONSE Enclosed in TVA's supplemental response to detall completion of compensatory measures as committed to in the April 20, 1983 letter that transmitted the initial information requested by NRC cover letter dated March 9, 1988. provides completion schedules for compensatory measures. contains a list of commitments contained in this submittal.

If you have any questions, please telephone M. R. Harding at (615) 870-6422.

Very truly yours, TEN E

Y AUTHORITY R. G idley, Dir ctor Nuclear Licens ng and Regulatory Affairs Enclosures cc:

See Page 2 4

f h

h 8806130230 890606 PDR ADOCK 0500 7

An Equal Opportunity Employer

'J U.S. Nuclear Regulatory Commission ggg cc (Enclosures):

Mr. K. P. Barr, Acting Assistant Director for Inspection Programs TVA Projects Division U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Ms. S. C. Black, Assistant Ofrector for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Sequoyah Resident Inspector F:quoyah Nuclear Plant 2600 Igou Ferry Road Soddy Daisy, Tennessee 37379 4

l

ENCLOSURE 1 1.

The following is.a list of compensatory measures (cms) with updated corrective action and completion dates.

a.

Condition Adverse to Quality Report (CAQR) SQP870217: Main control room standby air-conditioning start, determine logic circuitry problems in the systems.

System supplier has been contracted to provide recommendations for long-term corrective action.

Supplemental response will be submitted by September 30, 1988.

b.

Significant condition report (SCR) SQNEEB86136: Manually isolate certain tornado dampers; modify tornado dampers by reversing air lines to associated solenoid valves in accordance with engineering change notice (ECN) L6900 and workplan (HP) 12527.

Design and fieldwork complete.

c.

ECN L6712:

Do not use alternate feeder breaker for turbine-driven auxiliary feedwater pump; ECN and HP#12147 are complete.

d.

SCR SQNMEB8677: Manually realign the spent fuel pit heat exchanger from train "A" to train "B" of component cooling system.

Abnormal Operating Instruction (A01) 35, revision 5, was approved January 1, 1988.

CM has been integrated into plant design. CM has been cancelled (i.e., complete).

e.

SCR SQNNEB8617: Open valve 77-920 to drain annulus sump to Auxiliarys Building passive sump.

System Operating Inst,'iction (501) 55 revised to incorporate CM.

501-55-1M15-XA-55-15A, revision 5, approved June 23, 1987; and 501-55-2M15-XA-15, revision 3, approved June 30, 1987.

f.

Memorandum (S53 851206 915): Limit radioactivity in discharge from l

evaporator bottoms to boric acid tanks.

Technical Instruction 37, revision 26, has been revised and approved to incorporate administrative limits. CM has been integrated into plant design.

CM has been cancelled.

g.

Employee Concern Element Report No. EC230.01:

Shutdown / restarting ventilation because of fire damper design concerns; A01-30, step E, revised May 13, 1987. New 6amper for 0-31C-1744 to be installed next refueling outage for unit 2.

h.

EC243.00: Operations to shed selected loads from the diesel generators in the event of a station blackout. A0I-35, revision 8, approved July 1, 1987. CM has been integrated into plant design.

CM has been cancelled.

1.

EC17301:

Backfilling sense lines because of instrument line slopes.

Maintenance Instruction (MI) 19.1.1 through MI-19.1.8 revised and approved July 1, 1987. CM has been integrated into plant design.

CH has been cancelled.

t

__,,_,_m. _ _,, _ _. _

.,_,yo,,_.._,m,_.., _ _ _. _,,. _,,. _

, _. _ _ _ _, _ _ _ _, _ _ _ _., _, _ _. - _ _ _ _, _ _. _ _ _ ~ _ _ _ _ _, _ _.. _

. j.

NRC Observation No. 6.22: Start backup heating, ventilating, and air conditioning on loss of auxiliary control air. CM has been integrated into plant design. CM has been cancelled.

k.

Corporate Coraitment Tracking System No. NC0850086020:

Establish operating procedures for shutdown logic to implement Appendix R; S0I-26.2 issued and item closed February 2, 1985.

CM has been integrated into plant design. CM has been cancelled.

1.

Operations printout No. 27. Appendix R submittal:

Power is removed from 49 valves in chemical and volume control system, component cooling system, and essential raw cooling water (ERCW).

Power must be manually restored during moderate-energy line break events.

CM has been integisted into plant design. CM has been cancelled.

m.

Memorandum (A27 630919 018):

During a loss of coolant accident, the ice condenser air-handling units must be tripped.

Emergency Procedure E-1, revision 4, was approved January 19,-1988.

CM has been integrated into plant design. CM has been cancelled.

n.

ECN L6073:

Heighing system for upper head injection (UHI) accumulators.

Surveillance Instruction 744 has been issued to monitor charging of UHI accumulators. Analysis and approval to remove UHI system are being pursued. A supplemental respcase will be submitted September 30, 1988.

o.

Integrated Design Inspection (IDI) No. D-2.09: Check ERCW supply to station air compressors.

Electrical Engineering Branch issued design change notice to add automatic isolation of ERCH on high flow to compressors. Work complete; A01-9, revision 10, has been issued. CH has been cancelled.

p.

IDI No. 02.2-7:

Turn supply fan off when the room temperature drops below 65 degrecs Fahrenheit.

General Operating Instruction 6H, revision 31, was approved November 13, 1988. CM has been integrated into plant design. CM has been cancelled.

2.

The following is a list of cms with revised corrective actions or l

completion dates.

a.

Problem identification report (PIR) SQNEEB8683: Only essential space heaters energized.

TVA engineering is further evaluating scope and resolution. A supplemental response will be submitted September 30, 1988.

b.

CAQR SQP871696: Ultimate heat sink temperature change; ECN L7243 issued March 25, 1988; and work completed on May 16, 1988. CM was cancelled (i.e., complete) on May 23, 1988.

d ENCLOSURE 2 List of Commitments 1.

A supplemental response will be submitted by September 30, 1988, to define corrective action and provide final cotepletion dates for cms identified

below, a.

CAQR SQP870217 b.

PIR SQNEEB8683 c.

ECN L6073 2.

CH associated with EC230.01 willLbe completed by installation of new damper for 0-31C-1744 during the next refueling outage for unit 2.