Notice of Deviation from Insp on 880322-0502.Deviation Noted:Calibr Procedure SP-2404BA, Control Room Ventilation Monitor Calibr Used for Calibrs in Dec 1986,did Not Assure Reproducible,Fixed Geometry Configuraton
ML20154R531
Person / Time
Site: Millstone 
Issue date: 05/27/1988
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20154R524 List:
References
50-336-88-07, 50-336-88-7, NUDOCS 8806080004
Download: ML20154R531 (1)


Text

a f

h APPENDIX B NOTICE OF DEVIATION Northeast Nuclear Energy Company Docket No. 50-336 Millstone Unit 2 License No. DPR-65

-During routine safety inspection from March 22 to May 2,-1988, the following de-viation was identiffed, Final Safety Analysis Report (FSAR) 7.5.6.1.3 states that area radiation monitor calibration will be accomplished by placing the detector in a "repro-ducible, fixed geometry configuration," and exposing the detector to a "cali-brated radioactive source" placed at measured distances from the detector.

Contrary to the above, calibration procedure SP-2404BA "Control Room Ventila-tion Monitor Calibration," used for calibrations in December 1986, did not assure a reproducible, fixed geometry configuration or ensure that (1) dose rates generated by test sources were measured at a specific dista.1ce from the sources, and (ii) test sources were held at the same distance from the detec-tor during the calibration.

Northeast Nuclear Energy Company is hereby requested to submit to this office, within thirty days of the date of the letter which transmitted this Deviation, a written reply including: (1) the corrective steps to be taken'and results achieved, (2) corrective steps to be taken to avoid further deviations; and (3) the date when FSAR compliance will be achieved. Where good cause is shown, consideration-will be given to extending this response time.

OFFICIAL RECORD COPY DL50-336/88 0004.0.0 05/20/88 8806080004 880527 PDR.ADOCK 05000336 0