REGISTRY OF RADIOACTIVE SEALED SOURCES.AND DEVICES-SAFETY ~ EVALUATION OF SEALED' SOURCE-j:

i NO.: NR-300-S 852-S

-DATE:

2 I 1998 PAGE 1 OF 6 2

' SEALED' SOURCE TYPE: ' Radio' graphy Source Assembly

.MODEL:

"B" ' Series 4

.+'

MANUFACTURER / DISTRIBUTOR:

Gamma-Industries, Inc.

P.O.

Box 2543 Baton Rouge, LA 70821'.

1

-ISOTOPE:

MAXIMUM ACTIVITY:

Iridium-192 120 Ci (4.44 TBq)

Cobalt-60 220 Ci (8.14TBq)

LEAK TEST FREQUENCY:

6 months PRINCIPAL USE:

(A) Industrial Radiography

' CUSTOM' SOURCE:

YES X

NO 9810260191 981021 PDR RC SSD PDR

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE OCT 21 1998 NO.: NR-300-S-852-S DATE:

PAGE 2 OF 6 SEALED SOURCE TYPE: Radiography Source Assembly DESCRIPTION:

The Gamma industries Model "B"

series source assemblies are designed for use in Budd Company and Automation industries exposure devices, as shown in the attached pigtail selection chart (Limitations and/or Other Considerations of Use section).

The first charact'er in the source model designation indicates that the source assembly is designed f; use in one of these devices.

The second character is a ccle for the dimension of the source assembly.

The third (last) character in the source model number designates the type of connector.

"A" indicates a Gamma Industries long Saf-T-Key connector, "T"

indicates a Tech-Ops connector, "C"

indicates a Budd (clevis) connector, and "G"

indicates a Gamma industries short Saf-T-Key connector.

Iridium sources have a single encapsulation, while the Cobalt sources have double encapsulation.

Single encapsulation may use either an end-cap or side-weld.

Double encapsulation will use only an end-cap weld, and all encapsulation is accomplished using a Heliarc (TIG) welding technique.

Sources are encapsulated in either Type 304 or 316 stainless steel.

Capsule wall thickness is maintained at a minimum of 0.030" (0.76 mm).

The connector, locking ball, and source capsule are crimped to 3/32" (2.38 mm) diameter stainless steel cable except for the Automation Model 520.

Overall pigtail dimensional tolerance is plus or minus 1/16" (1.59 mm).

LABELING:

The source capsules are not large enough to allow direct labeling; however, the exposure device which contains the source capsule is labeled.

For additional labeling information, please refer to the particular exposure device in which the source is to be used.

DIAGRAM:

See Attachment 1.

,t f

c

s

.REGISTRYJOF RADIOACTIVE SEALED' SOURCES.AND DEVICES L

' SAFETY, EVALUATION OF SEALED SOURCE NO.:.NR-300-S-852-S DATE:

OCT. 2.i 1993 PAGE 3 OF 6 SEALED SOURCE TYPE: Radiography 1 Source. Assembly 1 CONDITIONS OF NORMAL USE:

E The Gamma? Industries Model "B"

series source assemblies,are I

designed-for use in the Budd Company and Automation Industries I

industrial radiography exposure devices shown in the pigtail 1

I

~ selection' chart.

l The "B"' series source assembly consists of a single or double encapsulated universal capsule.

The manufacturer states that sprototype' sources have met the criteria specified in ANSI publication N542-1977 and have a classification of ANSIE77E43515.

This ' source series-also has Eul IAEA Certificate of Competent Authority, Special Form Radioactive Material' Encapsulation,

~

Certificate Number USA /0166/S Revision 1.

Based on prototype test-' data these designs are expected to retain containment

~

~

integrity'under accident conditions most likely to occur during normal use or transportation.

PROTOTYPE TESTING:

For information concerning prototype testing, please see the "Abilityfof1 Sealed Source to Withstand Loss of Containment Under Abnormal Conditions."

EXTERNAL RADIATION LEVELS:

The dose rate:for Iridium-192 is 5.9-R/hr per Curie at 1 foot ll (3 0. 4 8 cm).

The dose rate'for Cobalt-60 is'14.4 R/hr per Curie j

' at11 ' foot. (3 0. 48 cm).

l l-l:

I l

<1 1

l:

L L

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE i

l NO.: NR-300-S-852-S DATE:

OCT 21 1998 PAGE 4 OF 6 SEALED SOURCE TYPE: Radiography Source Assembly i

I QUALITY ASSURANCE AND CONTROL:

Each pigtail assembly is. subjected to a 180 lb. (81.65 kg) pull test prior to radioactive material insertion and subjected to a wipe test after the material is sealed in the capsule.

If the results of the wipe test are doubtful, then a hot water bubble test 1is performed.

No source will be shipped if removable contamination exceeds 0.005 microcurie (185-Bq).

Source activities are checked against a standard by using an ion chamber.

A decay chart and source tag are supplied with each source, providing information concerning the activity and leak test results.

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

Series "B"

sources shall be possessed and used by specific licensees of the U.S. NRC or Agreements States.

. Series "B"

sealed sources shall not b'e subjected to environmental or'other conditions of use which exceed ANSI classification 77E43515.

Series "B"

sources shall be leak tested at intervals not to exceed six (6)' months using techniques approved by the licensing authority.and capable'of detecting at least 0.005 microcurie (185 Bq) of removable contamination.

. Series "B" source assembly shall b'e used only in the

~

following radiographic exposure devices:

. Handling, storage,;use, transfer, and disposal:

To be determined by the" licensing authority.

. This registration sheet ~and the information contained within the references shall not be changed without the written consent of the NRC.

(

E

-REGISTRY OF~ RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE l

NO.: NR-300-S-852-S' DATE:

OCT 21 1998 PAGE 5 OF 6 SEALED SOURCE TYPEi Radiography Source' Assembly

, LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE (Cont'd):

"B" SERIES PIGTAIL SELECTION CHART Source Automation Industries or Gamma Industries

/Model No. Isotope Budd Exposure Device Model Source Charger

'B-1-C Ir 10A, 20A,.30BA, 40BA, 103A,-

C-10

'B-1-G-

-100A, 100A-1 Series, 102A (C-8)

LB-2-C Co/Ir 50B Series, 110AB C-10 (Ir-192)

B-2-G C-8 (Co-60) i B-3-C Ir/Co-60C Series C-10 (Ir-192)

B-3-G' C-8 (Co-60)

B-4-C-Ir 40AD C-10 B-4-G B-5-C, Ir 40E-C-10 LB-5-G 1

B-6-C Co/Ir 150 Series C-10 (Ir-192) l' B-6-G C-8 (Co-60)

"B-7-C' Co/Ir 160deries C-10 (Ir-192)

D-7-G 160 Series C-8 (Co-60)

.B-8-A' Ir 520 Series C-10 B-8-C

' B-8-G.

B-8-T' I

SAFETY ANALYSIS

SUMMARY

l The Model "B". Series sources are no longer manufactured or j

} distributed by Gamma Industries, Inc. and Gamma Industries, Inc.

)

is'no longer.in business.

Therefore, the registration I

certificate is being converted to an inactive registration j

certificate.

I

I REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE L

NO.: NR-300-S-852-S DATE:

I2119%

PAGg, OF 6

~ SEALED SOURCE TYPE: Radiography _ Source' Assembly

' SAFETY ANALYSIS

SUMMARY

'(Cont'd):

2 The sources were originally.' approved forflicensing purposes by

~

the Louisiana Di' vision of Radiation' Control.

NRC attempted to obtain copies of all~'information submitted'by the registrant in

. support of the evaluation. !However, NRC could not locate all the i

information.

Therefore, no safety evaluation of the sources was performedfas part of the conversion of the certificate to inactive' status.

ISSUING AGENCY:

U.S.

Nuclear Regulatory Commission

/,

Date:

OCT 21 1998 Reviewer:

/

s

' John W.

Lubinski ISS8 Concurrence: WM-[

Date:

%m Michele L.

Burg 6ss L

?

t i'

i

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF-SEALED SOURCE NO.:'NR-300-S-852-S DATE:

OCT 21 1998 ATTAcnseur 1 emee,.wehw a r**+we+==wm<,ee.-

  • A =r 3

L-

...... /...'l',,".i. ;, ' l.,,,. I '

o

+-a i s oi-oi-io~-..

n-i" n-wi

/

' ' / '-

'"^- '"^ * ^' *""^* '"'^-

1'

/

cim.nniiumiivii/

/

100A, 100A-1 Serien. lulA

[

ZV"''i M 12- /8

-3 50B s ries, 11 AB

\\

DIA. SSCABLE B-2-c 12-1/8 l-l/4 l

nB"

_l

%" 4/,2 Js SEE NOTC(c)

B-3-C 14-3/4 1-1/2 60C Surles i

i u

u-3-c 14-3/4 l-3/8 B-4-C 6-1/2 1-1/4 40AD l 0CHING BAl.L V4 "LG Y. V[Oi A.

B-4-G 6-l/2 1-1/8 n-5-C 6-1/4 1-1/4 40E i

B-5-c 6-1/4 l-l/8

.e #8: The Canna "A" connec tor and Tech-Opu "T" B-6-C 15-15/l'6 1-7/8 150 Serien 1

connectors may be used on Hodel 520.

B-6-G 15-15/16 l-3/4

.c #7: t/8" cable used on 520 series source.

B-7-C I4-1/16 2

160 Series

.e 06: Budd Model 102A, 50s Serleu 6 60B Series Cobalt B-7-C 14-l/16 l-7/8 will be singly encapuuluted due to umall B-8-C 6-13/16 3/4 520 Series diameter guide tubes. Hodel 150 & 160 Series B-8-G 6-13/16 5/8 Cobalt will be doubly encapsulated as detailed B-8-A 6-13/16 1/2 on Drawing 73-5-2, page 2.

B-8-T 6-13/16 5/16 e e5: Pigtall overall length tolerance'will be held to

  • 1/16".
  1. 4r. Cable will be inserted into capsule & connector e

shank 1/4" then crimped.

  1. 3: The "C" Automation Industries connector or "C" e

. short sa f-t-key may be used.

  1. 36 Capsule wall thickness held to 0.030". minimum.

e dit Capsule fabricated of 304 or 316 stainless steel.

1

.625'M AY.

m iac TIG WELO c '",. i F

Ff GAMMA INDUSTRIES 8.R.,LA s

,.4Ch

-. }

g y if/

^

.< s,t 4

3o0

....., x o s b

'E 6 l2'*.

3 g c4 j

f R j'

9/s A / ~11 annuc3YF7h't:

ann.

_ey: U a u j//////3 j

3 US' a pA oio e n a ppy sog ne c 433 c r et_v ref puoo e,

.I 7

i A uro MATiorg IN OVST RIES CMOSVRt '

E.vl S E S

. ho hn i t.6.

OCIAI' i

, f

'*i....

.u.,._

~

PAGE1 l'

NRC FORM 567 U. S. NUCLEAR REOULATORY COMMISSION m

REQUEST FOR A SEALED SOURCE OR

[

DEVICE EVALUATION -

INSTRUCTIONS: Send this request AND a copy of all reisted letters / applications and drawings to: The Sealed Source Safety Section, ATTN: CNef, OWFN Mail Stop 6 H3. Change the License Tracidng System milestone to 19 and assign to reviewer code I-5.

NOTE: Retain a copy of tNs request with the appilcation and back round flies.

0 REO cd REGION / LOCATION:

Op71d74

_. J7C N!T/8 b lI H U Hi IV RV U HQ R LFDCB TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as appropriate)

APPLICANM NAME SOURCE REVIEW AMENDMENT OF REGISTRATION SHEET Mast ConrROL NUMBER (S)

DEVICE REVIEW NUMBER (S) h-N hMk/

LETTER / APPLICATION DATE LICENSE NUMBER (S)

- CUSTOM REVIEW

(/}%d.

/

6 &

&?343 AnAm SmMO LA 76%2/

\\

FOR 8888 US$ ONLY NUMBER AS$GNED j

RexWER NUMBERS r>1nia af)

TD

{

~~

DATERECENED /

/

DATE ASSONED DATE TO FEES 8/ff /98 s=//-M

\\

TYPE OP ACTION on.ica ein,s.M, e,ocea y,e) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM) j j

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (98)

~

NEW PEW NEW NEW AMENDMENT AMENDMENT AMENDMENT AMENDMENT j NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED

] OTHER (Specify) l TOTAL NUMBER OF NOTES REVIEW HOURS j

NUMBER OF 1

g h

/

/ d.

DEFICIENCY LETTERS s

//7[] C / k NUMBER OF g{j DEFICIENCY CALLS FOR BILLING PURPOSES ONLY j NEW REGISTRATION -

J PRODUCT INACTIVE-NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY

)

TYPE OF FEE

[NWM-FEE CATEGORY

~

9C U 90 i

19A U 90 tz AMCWT RECENED

\\

CHECK NUMBER MATANN UPDATED l

-4 AS REQUIRED l

}L7A

}' yykD j MATSYS UPDATED DATE W CHECK LOG a

,wf

+,

AS REQUIRED k~ -

d27iiI APPROVED BY DATE RETURN DATE 8

NRC FORM b67 (&S3)

ORIGINAL TO SSSS 7,,.

.~

, g?

p -

-v m,,

.s REGISTRYOFRADI0ACTIVESEALEDSOURCISAND. DEVICES

. SAFETY EVALUATION OF DEVICE 1

l N0.:

LA3000128U

'DATE:

May 1973 P,A',E 1 0F 3 10EVICE' TYPE:

Radiographic Exposure Device.

MODEL:

Gammatron 50-A MANUFACTURER / DISTRIBUTOR:

Ganne ' Industries, Inc.

P.O. Box 2543 Baton Rouge, LA 70821 MANUFACTURER / DISTRIBUTOR:

SEALED SOURCE MODEL DESIGNATION:

Gamma Ind. A-7-A or A-7-G ISOTOPE: Cobalt-60 MAXIMUM ACTIVITY:

50 curies Depleted Uranium Shielding, 91 kilograms LEAK TEST FREQUENCY:

i PRINCIPAL USE:

Industrial Radiography CUSTOM DEVICE:

YES' X N0

\\^

l

..