ML20154P028

From kanterella
Jump to navigation Jump to search
Requests Cost Estimate for Installation of Addl Circuitry at Emergency Operations Facility & Permission to Use Site & Util Property for Contingency Telecommunications.Frequencies That NRC Equipment May Use at Each Site Encl
ML20154P028
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 05/25/1988
From: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
References
NUDOCS 8806030175
Download: ML20154P028 (3)


Text

.-_ . _ _ - - - _ _ _ _ - _ - _ _ _ -

t MAY 2 51988 Docket No. 50-271 Vermont Yankee Nuclear Power Corporation ATTN: Mr. Warren P. Murphy Vice President and Manager of Operations RD 5, Box 169 Ferry Road Brattleboro, Vermont 05301 Gentlemen:

Subject:

Request for a Cost Estimate from Vermont Yankee Nuclear Power Corporation (VYNPC) for the Installation of Additional Circuitry at the Vermont Yankee Power Plant E0F and Permission to Use Site and Company Property for Contingency Telecommunications In the event of an emergency at a nuclear station, the NRC would request the Boise Interagency Fire Center (BIFC) to be dispatched to the site with radio equipment for promptly establishing an off-site communications network between the Emergency Operations Facility and the Federal off-site monitoring team.

To accomplish this goal, the NRC had a communications survey conducted by BIFC for each site nationwide. This survey identified the requirements for emergency radio-communication and any pre-installed equipment that would be necessary. The communications survey was conducted at the Vermont Yankee Power Plant facilities by an NRC contractor representative on approximately June 25, 1987.

Based on this survey, NRC Region I is now initiating arrangements for the installation of contingency emergency telecommunications equipment at the Vermont Yankee facilities. We are seeking your cooperation and assistance in establishing this capability. Your assistance is requested to obtain (1) a cost estimate for the installation of additional telephone circuits in the Emergency Operations Facility (E0F), and (2) permission for the NRC to install temporary antennas during emergencies, or as described below. The circuits and antenna locations are essential elements of our emergency telecommunications plan for Vermont Yankee. It should be noted that communications. equipment, other than the additional telephone circuits necessary to support them, will only be installed at the communications sites in the event of an actual emergency or NRC participation drill and will be removed immediately at the termination of the emergency or drill.

We are seeking a VYNPC cost estimate for labor and material to permanently establish three twin-lead voice quality d-c control pairs from the NRC room in the EOF to the roof of the E0F. The lines should be terminated at both ends with WE-724 connectors and should be marked for "NRC Emergency Use Only." The roof terminations should be housed in a weather proof box. These lines will allow installation of the base station equipment required to establish commun-ications from the E0F to the NRC repeater system. The WE-724 connectors will be supplied by the NRC.

OFFICIAL RECORD COPY BIFC LTRS 8/31/87 - 0001.0.0 05/18/88 g(

8806030175 080525 ln==

PDR ADOCK 05000271  :

pr PDR l

_ ~. _ _ _ , ._ _ _ _ ,_ _ -. _

t Vermont Yankee Nuclear Power 2 MAY 2 5 1989 Corporation We are also seeking VYNPC long term permission for the following, if it should become necessary, reserve the two-hundred-eighty foot level of the met tower for use by the NRC for the temporary installation of antennas and repeater packages in case of emergency.

If you agree to our request please indicate in your reply if the wiring installation for the EOF will be performed by VYNPC and if not, please provide a listing of preference for sub-contractors. Following receipt of your estimate, NRC, Region I will issue the necessary purchase order. Work should not commence prior to receipt of the purchase order.

If you have any questions regarding the above, please feel free to contact Robert J. Summers (215) 337-5083 of my staff.

Enclosed for your information are the frequencies that the NRC equipment may use at the Vermont Yankee site. We appreciate your assistance in this matter.

Sincerely, Original Signed By:

Ronald R. Bellamy Thomas T. Martin, Director Division of Radiation Safety and Safeguards

Enclosure:

Transmitter Frequencies cc w/ encl:

K. Perkins, AE00 S. Cohen, TB D. Herman, Boise Interagency Fire Center 3905 Vista Ave., Boise, Idaho 83705 Public Document Room (PDR) local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Senior Resident Inspector T. McCarthy, Emergency Preparedness, Vermont Yankee bec:

Region I Docket Room (with concurrences)

RI:DR S RI:DR R: SS R SS Mfh RI:DRSS Tuccince#/k1/ms/sh Fox Lazarus Bellamy Martin s ~cr s 5/t9/88 5/h/88 5/y}/88 5/LA /88 5/ } /88 0FFICIAL RECORD COPY BIFC LTRS 8/31/87 - 0002.0.0 05/18/63

ENCLOSURE The frequencies that the NRC equipment may use at each site are as follows:

E0F Transmit 417.300 417.350 417.500 417.800 Met tower Transmit Receive Transmit Receive 168.400 166.6125 411.750 417.300 167.100 169.750 411.925 417.350 169.350 166.725 412.150 417.500 412.200 417.800 All power levels will be at 6 watts or less.

~

"ggj?;, { 'N -'

. _ .