REGISTRY OF RADZOACTIVE SEALED SOURCES AND DEVICES l.

SAFETY EVALUATION OF SEALED SOURCE OCT 0 71998 NO.: NR-8095-S-805-S DATE:

PAGE 1 OF 5 DEVICE TYPE:

Sealed Source Training Set.

l l

l MODEL:

CDV-778, CDV-782, CDV-784, and CDV-786 I

l DISTRIBUTOR:

Federal Emergency Management Agency (FEMA) 500 C Street S.W.

Washington, DC 20472 I

(

MANUFACTURER:

Reed-Curtis, Tracer Lab, I

Baird-Atomic, 3M l

ISOTOPE:

MAXIMUM ACTIVITY:

l Cobalt-60 30 mci (1.11 GBq)

~

Cesium-137 132 mci (4.88 GBq) (3M Model 4F6Y]

l

(

LEAK TEST FREOUENCY:

6 months i

PRINCIPAL USE:

(T) Calibration Sources DJSTOM DEVICE:

YES X

NO l

i r

l Y

l 9g10000244 981007 PDR RC PDR BSD

1 REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE i

NO,: NR-8095-S-805-S

'DATE:

OCT 0 71988' PAGE 2 OF 5 DEVICE TYPE:

Sealed Source Training Set DESCRIPTION:

The Sealed Source Training Set (CDV-778) consists of 6 or 12 sealed sources containing Co-60 or 6 sources containing Cs-137, and the associated instruments and equipment necessary to safely utilize the sources for training classes and exercises.

The components of the set are as follows:

i 1

  • One (1) CDV-700 CM Survey Meter (0-50 mR/hr) (0-0.5 mSv/hr)
  • Two - ( 2 ) CDV-138 Self-Reading Dosimeters (0-200 mR) (0-2 mSV)
  • One (1) - CDV-750 Dosimeter Charger
  • One - (1) CDV-788 18 inch (4 5.7 cm) tongs for handling sources
  • One (1) CDV-791 Inner Lead Container
  • One (1) CDV-792 Outer Lead Container for storing the sealed sources
  • Two (2) Locks to secure CDV-792 Each Sealed Source Training Set'contains one or more of the following sets of sealed sources:
  • Six (6) (5 mci / source, 30 mci / set- [185 MBq/ source, (1.11 GBq/ set)]) Co-60 CDV-784 Sealed Sources,
  • Twelve (12) (0 to 5 mci / source, 30_ mci / set [740 MBq/ source, (1.11 GBq/ set) ] ), Co-60 CDV-786 Sealed Sources,
  • Six (6) 20 mci t 10%/ source, 132 mci max / set

[740 MBq/ source, (4.88 GBq/ set)]) Cs-137 CDV-782 Sealed Sources At-the time of encapsulation, each Co-60 source set contained 3

30_ mci (1.11 GBq) (+20%,. -10%).

Each' source is encapsulated in stainless steel.

These capsules were serially numbered at the' time of manufacture.

The CDV-782 was designed to replace the old CDV-786_ set.

DIAGRAM:

See attachments 1 - 4.

i l

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE j

NO : NR-8095-S-805-S DATE:

PAGE 3 OF 5 OCT 0 71998 DEVICE TYPE:_

Sealed Source Training Set LABELING:

The manufacturer provided information which indicated that the i

source capsule would be distinctly and permanently marked with the manufacturer, serial number, and chemical symbol.

In addition, the sealed sources were tagged with a one-inch (25.4 mm) (minimum) square, yellow warning tag stating the type of radioactive material, the quantity in millicuries, and the date of encapsulation.

The tag also contains the following instructions:

" DANGER - Radioactive Material - DO NOT HANDLE - Notify Civil Authorities if found;" and bears a conventional radiation symbol as prescribed by 10 CFR 20.1901 and 10 CFR 20.1904.

CONDITIONS OF NORMAL USE:

These training sets are used for training radiological instructors, radiological monitors, and instrument operators to demonstrate radiological instrument operation, and to calibrate and/or check the operability of radiological instruments.

The sealed sources are also used in various training situations and exercises designed to give instruction in the principles and procedures for the detection, measurement and control of radiation.

EXTERNAL RADIATION LEVEL:

Radiation dose rates were calculated for a 30 mci (1.11 GBq)

Co-60 source and a 132 mci' (4. 88 GBq) Cs-137 source.

The dose rates are based on an NIST traceable standard and are as follows:

Distance Maximum Radiation Level (from surface)

Cobalt-60 Cesium-137 (cm)

(in)

(R/hr)

(Sv/hr)

(R/hr)

(Sv/hr) 5 1.97 16.2 0.162 17.4 0.174 30 11.81 0.45 0.0045 0.48 0.0048 100 39.37 0.04 0.0004 0.04 0.0004

. - ~. -

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.:-NR-8095-S-805'-S DATE:

OCT 0 71998 '

PAGE 4 OF 5 DEVICE TYPE:

Sealed Source Training Set PROTOTYPE TESTING:

The Federal Emergency Management' Agency had stated that pre-production sample groups were tested in conformance with standard practices of the National Bureau of Standards.

In addition, these sealed sources had been previously deemed acceptable for licensing purposes by the AEC and have been in use since at least 1982.

OUALITY ASSURANCE AND CONTROL:

Federal Emergency Management Agency had a quality control program which had been deemed acceptable for licensing purposes by the NRC.

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

  • The sealed sources may be used by persons specifically licensed by the NRC or an Agreement State.
  • These sources will no longer be commercially distributed but may still may be approved for licensing purposes.
  • Handling, storage, use, transfer, and disposal: To be determined by the licensing authority.

These sources may exhibit high dose rates and should only be handled by experienced licensed personnel using adequate remote handling equipment and procedures.

  • Sealed sources shall not be subjected to conditions which exceed their ANSI classification.

i

  • The sealed sources shall be leak tested at intervals not to exceed 6 months using techniques capable of detecting 0.005 microcurie (185 Bq) or removable contamination.
  • This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.

SAFETY ANALYSIS

SUMMARY

Based on the review of the information cited in the references, we continue to conclude that Models CDV-778, CDV-782, CDV-784, and CDV-786 are acceptable for specific licensing.

=

^

l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: 'NR-8095-S-805-S DATE:

OCT 0 71998 PAGE 5 OF 5 1

1 l

DEVICE TYPE:

. Sealed Source Training Set 1

l l

SAFETY ANALYSIS

SUMMARY

.(Cont.)

i Furthermore, we continue to conclude that these sealed sources l.

would be-expected to maintain their containment integrity for normal conditions of use and accidental conditions which might occur during uses specified in this certificate.

REFERENCES:

Thelfollowing supporting documents for the Model CDV-778, CDV-782, _CDV-784, and CDV-786 Sealed Source Training Sets are L

hereby incorporated by reference and are made a part of this registry document.

e' Federal Emergency Management Agency renewal application for Materials License No. 08-01297-06, dated August 10, 1992, with enclosures thereto.

  • Manual of Procedure for the Use and Control of the CDV-778

. Radiation Training Source Set dated August 1975.

  • Office of Civil and Defense Mobilization letter dated April 6, 1959, stating that the CDV-784 was to replace the CDV-786.
  • Federal Civil Defense Administration Standard Item Specification dated May 23, 1956, for the Model CDV-786.

1 ISSUING AGENCY:

U.S. Nuclear Regulatory Commission Date:

Reviewer:

  1. 6dd /[h-w/

07 M

Michele, BurgMss OCT 0 71998 Date:

Concurrence:

~

J n W.

Lubinski l

~..

REGISTRY'OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE ECL l. NR-8095-S-805-S DATE-OCT 0 71998 ATTACHMENT 1 l

l.

--- -Ni A R r.H 24, I 9 5 9 d D V -7 64 k

SOURCE CAPSULE _-

FOR klN. DI A. COB ALT - 60 CAP I

k 7

/r6 BREAK EDGE

NMxy, ke p

i lh, i m i

1 fi 4

i l

r f.

N

~

CHAMFER

~

s' N

=_.

-~

Wlll'e I: ;."...,

. li 1

. S.- DIA.

c.

32 f

k

/

.r.....

,4 l jl

.$@a..

l il a'; %~

l' l

ai, 4

l'd.

~ n>

cgy.-784

'r l

b o

\\

SOURCE CAPSULE BASE

i

!~

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-8095-S-805-S DATE:

OCT 0 71998 ATTACHMENT 2

, 'M AR C H 2 4,19 5 9 C D V - 7 8'4 "'

'J l-TAG l

f h

a 5 MC COB ALT 60 6/59

(

)

L l

(

h l

MANUFACTURERS l-NAME DANGER R ADIOACTIVE MATERI AL

(

DO NOT HANDLE NOTI F Y CIVll t

AUTHORITIES IF F OUND l

k

)

4 f

L

i I

i REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-8095-S-805-S DATE:

OCT 0 71998 ATTACHMENT 3 l

..'h.',,'*b.,

a

. ',,p'i ',,

  • ,, =

4'y;.

w.Q.
15.. '-

.)

  • 6 ;'

.,s

'=

-Y,

.250 Ou4 i

M

.220 0 A l i 6

.isc l

i

/

!\\

Modd 1

A 60 GDV-7T1 i ~

m

..C C C l

I l

U i

l i

i 0 A Hcu f.

3 L-J 16 g

f

.i se CH l

I l

l

'~.o94 l

ln

.f-

.. s s

)

I

\\

,e w,

an V

l l-l i

l t

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES l

SAFETY EVALUATION OF SEALED SOURCE NO,t NR-8095-S-805-S DATE: OCT 0 71998 ATTACHMENT 4 r.080

, u=...p

-=:n. :-. y

/

.w

.6;00 2 3 EYEu t 7 ----

)

i I

' ' 4.:

9 l

i

"** {

]

y-PG v

t

,e'.

(

]

]

Ypj7 c DV-772 6

w fo}

kf l INCH 50VAAC i

+.L

~6' AA0;CAG7N)E l Odi1GER M AT E Riot.

C

-This side of tag -

be se,amped

{RTTP FEMA.$.ll) h Federal Emegency

~

Management Agency

~,,

~

OO NOT HANDL$

ncnr* Ovit.

40IHQ$1TI($ IF TQ2i9 k(0 MC OF C3-137 04__

.1 2

_ _ :3

\\

7 l

l I

L Vernon L. Wingert

. OCT 0 7 sp' Chiirper::on, Radiation Control Committee -

Federal Emergency Management Agency 500 C Street S.W.

l Washington, DC 20472

Dear Mr. Wingert:

Based on the request submitted in your letter dated March 17,1997, we have transferred the following registration certificates below to inactive status. The registration numbers of the

)

~

certificates have been changed:

FROM

'TO MODEL(S) l NR-283-D-801-S '

NR-8095-D-801;S UDM1A (C' V-793)

D L

NR-283-D-802-S NR-8095-D-802-S CDV-795 NR-283-D-803-S NR-8095-D-803-S CDV-798 NR-283-D-101-S NR-8095-D-804-S CDV-757 NR-283-S-102-S NR 8095-S-805-S CDV-778, CDV-782, CDV-784, CDV-788 NR-283-D-105-S NR-8095-D-806-S CDV-794, Model 2 NR-283-D-106-S NR-8095-D-807-S CDV-797 NR-283-D-110-S NR-8095-D-808-S CDV-791, CDV-792 NR-283-D-111-S NR-8095-D-809-S CDV-790, Model 1 L

Please review the registration certificates (copies enclosed) in their entirety and notify us L

immediately if there are any errors or omissions.

l If you have any questions, please contact me at (301) 415-5799 or Michele Burgess L

at (301) 415-5868.

Sincerely, l

O Eric B. Compton, Engineering Aide Materials Safety Branch Division of Industrial and Medical Nuclear Safety l

Office of Nuclear Material Safety and Safeguards

Enclosures:

As stated cc w/ encl: SKimberley, LFDCB

. Distribution:

f

[

SSSS r/f NE01 NR-8095-D-801-S NR-8095-D-802-S k

i l

NR-8095-D-803-S NR-8095-D-804-S NR-8095-S-805-S NR-8095-D-806-S NR-8095-D-807 S NR-8095-D-808-S NR-8095-D-809-S DOCUMENT NAME: H:\\ERIC\\COMPLTR\\N80958XX.WPD Te receive a copy of tNe doeurnent, indicate in the box: "C* = Copy without attachinent/ enclosure "E* = Copy with attachment / enclosure "N* = No copy.

L OFFICE MSB lc MSB lE l

l l

l NAME ECompton c MBurgess y g DATE 9/.'z /98 9/ ;/98 OFFICIAL RECORD COPY

{ 'p'l CSbD r

A REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (Amended in its Entirety)

HQ1 NR-283-S-102-S DATE:

September 22, 1995 PAGE.: 1 OF 5 SEALED SOURCE TYPE: Sealed Source Training Set MODEL:

CDV-778, CDV-782, CDV-784, and CDV-786 MANUFACTURER:

Federal Emergency Management Agency (FEMA)

Washington, D.C.

20472 DISTRIBUTOR:

Reed-Curtis, Tracer Lab, Baird-Atomic ISOTOPE:

MAXIMUM ACTIVITY:

_ Cobalt-60 30 mci (1.11 GBq)

Cesium-137 132 mci (4.88 GBq) (3M Model 4F6Y]

LEAK TEST FREOUENCY:

6-months l

PRINCIPLE USE:

(T) Calibration Training i

CUSTOM SOURCE:

YES X

NO

.jNt)(~C$"~~

{ {3 s

_ ~

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES l

SAFETY EVALUATION OF SEALED SOURCE (Amended in its Entirety)

L HQ1 NR-283-S-102-S P ^lEl September 22, 1995 PAGE: 2 OF 5 SEALED SOURCE TYPE: Sealed Source Training Set DESCRIPTION:

The Sealed Source Training Set (CDV-778) consists of 6 or 12 sealed sources containing Co-60 or 6 sources containing cesium-137, and the associated instruments and equipment necessary to safely utilize the sources for training classes and exercises.

The components of the set are as follows:

One (1) CDV-700 CM Sur' rey Meter (0-50 mR/hr)

(0-0.5 mSv/hr)

Two (2) CDV-138 Self-Reading Dcaimeters (0-200 mR) (0-2 mSv)

One (1) CDV-750 Dosimeter Charger One (1) CDV-788 18 inch (45.7 cm) tongs for handling sources One (1) CDV-791 Inner Lead Container One (1) CDV-792 Outer lead container for storing the sealed cources Two (2) Locks to secure CDV-792 Each Sealed Source Training Set contains one or more of the following sets of sealed sources:

30 (185 MBq/ source, (1110 (5 mci / source,Co-60 CDV-784 / mci /setealedfources, Six (6)

MBq/ set)))

Twelve (12) (0 to 5 laCi/ source, 30 mci / set 0-185 MBq/ source, (1110 MBq/ set))) Co-60CDV-786pgaledsources, Six (6) 20 mci 10%/ source, 132 mci max./ set [740 fealedsourceg MBq/ source, (.88 GBq/ set)]) Cs-137 CDV-782 5

At the time of encapsulation, each Co-60 source set contained 30 mci (+20%, -10%).

Each source is encapsulated in stainless steel.

These capsules were serially numbered at the time of manufacture.

The CDV-782 was designed to replace the old CDV-786 set.

DIAGRAM:

See attachments 1 - 4

. ~ -

REGISTRY OF RADIOACTIVE SEALED SOURCES AND SAFETY EVALUATION OF SEALED SOURCE (Amended in its Entirety)

DATEL September 22, 1995 PAGE: 3 OF 5 HL_

NR-183-S-102-S Sealed Source Training Set SEALED SOURCE TYPE:

i

_LABELINGL h

The manufacturer provided information which indicated that t e ith source capsule shall be distinctly and permanently marked w

)

In the manufacturer, serial. number and chemical symbol.

addition, the sealed sources were tagged with a one-inch- -

yellow warning tag stating the type of and the date the quantity in millicuries, (minimum) square, radioactive material,The tag also contains the following of encapsulation." DANGER - RadioouLive M terial - DO NOT HANDLE -

Notify Civil Auttorities if found;" and bears a conventional instructions:

(2), 10 CFR 20.

radiation symbol as prescribed by section 20.203

_ CONDITIONS OF NORMAL USE:

These training sets are used for training radiologicaland instrument operat radiological monitors, instrument operation, and to calibrate instructors, The demonstrate radiological and/or check the operability of radiological instruments.

i d

sealed sources are also used in various training situat ons an il d

exercises designed to give instruction in the prin i

i

_ EXTERNAL RADIATION LEVEL:

(1.11 GBq)

Radiation dose rates were calculated for a 30 mci The dose (4.88 GBq) Cs-137 source.

Co-60 source and a 132 mCirates are based on an N llows.

Maximum Radiation Level Distance Cs-137 (from surface)

Co-60 (cm)__

(in)

(R/hr)

(Sv/hr)

(R/hr)

(Sv/hr) 0.17Lk 5

1.97 16.2 0.162 17.4 30 11.81 0.45 0.0045 0.48 0.0048 100 39.37 0.04 0.0004 0.04 0.0004 g

4 1

4 REGISTRY OF RADIOACTIVE SEALED SOURCES A SAFETY EVALUATION OF SEAL *CD SOURCE (Amended in its Entirety) 1995 PAGE: 4 OF 5 DATEL September 22, NR-283-S-102-S HQ1 Sealed Source Training Set SEALED SOURCE TYPEL PROTOTYPE TESTINGL The Federal Emergency Management Agency states that with pre-production sample groups were tested in conformance d

In standard practices of the National Bureau of Standar s.

l deemed addition, these sealed sources have been previous y have been in use acceptable for licensing purposes by the AEC and since at least 1982.

OUALITY ASSURANCE AND CONTROLL d control Federal Emergency Management Agency has a quality an i

purposes program which has been deemed acceptable for licens ng by NRC.

EL LIMITATIONS AND/OR OTHER CONSIDERATIONS OF US i

The sealed sources may be distributed to specif c licensees of the NRC or Agreement States.

transfer, and disposal are to

use, These Handling, storage, be determined by the licensing authority.

sources may exhibit high dose rates and the sourcesl should be handled by experienced licensed personne using adequate remote handling equipment and procedures.

Sealed sources shall not be subjected to conditions which exceed their ANSI classification.

l The sealed sources shall be leak tested at interva f

not to exceed 6 months using techniques capable o detecting 0.005 microcurie (0.185 MBq) of removable contamination.

d This registration sheet and the informati h

written consent of the NRC.

=

~

e.

e REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE (Amended in its Entirety)

H21 NR-283-S-102-S DATE:.

September 22, 1995 PAGE: 5 OF 5 SEALED SOURCE TYPE: Sealed Source Training Set SAFETY ANALYSIS

SUMMARY

Based on the review of the information cited in the references, we continue to conclude that Models CDV-778, CDV-782, CDV-784, and CDV-786 are acceptable for specific licensing.

Furthermore, we continue to conclude that these sealed sources would be expected to maintain their containment integrity for normal conditions of use and accidental conditions which might omcur during uses specified in the certificate.

REFERENCES:

The following supporting documents for the sealed source training of set are hereby incorporated by reference and are made a part this registry document:

Federal Emergency Management Agency letter dated September 9, 1991, requesting amendments to registration certificates Federal Emergency Management Agency renewal application for Materials License No. 08-01297-06 dated August 10,.

1992, with enclosures thereto Manual of Procedure for the Use and Control of the CDV-778 Radiation Training Source Set dated August 1975 l

Office of Civil and Defense Mobilization letter dated April 6, 1959, stating that the CDV-784 was to replace the CDV-786 l

Federal Civil Defense Administration Standard Item l

Specification dated May 23, 1956, for the Model CDV-786 i

l ISSUING AGENCY:

f U.S. Nuclear Regulatory Commission

'M Date:

Sectember 21, 1995 Reviewer:

h3 Thomas W. Rich i

M Date:

Sectember 22, 1995 Concurrence:

' Steven 6." Baggett

fM4 q g#

b2 UNITED STATES g

j NUCLEAR REGULATORY COMMISSION 2

WASHINGTON, D.C. 2006H001 p%..... p$

4 NOTE TO:

SSD97-23/28 Federal Emergency Management Agency (FEMA)

FROM:

Eric B. Compton, Engineering Aide Materials Safety Branch r-Division of Industrial and Medical

(#

Nuclear Safety Office of Material Nuclear Safety and Safeguards DATE:

September 14,1998 RE:

REFERENCES NOT FOUND IN FILE in the process of transferring several of FEMA's registration certificates to inactive status it was discovered that a number of items which had been referenced in the original registration certificates were not in the background file. These included the following:

1.

Federal Civil Defense Administration Standard item Specification dated May 23,1956, for the Model CDV-786.

2.

Office of Civil and Defense Mobilization letter dated April 6,1959, stating that the CDV-784 was to replace the CDV-786.

3.

Manual of Procedure for the Use and Control of the CDV-778 Radiation training Source Set dated August 1975.

l l

4.

Equipment Manual /Use and Control of the CDV-798 Model I Radiological Survey Meter Calibrator dated August 1975.

5.

Federal Emergency Management Agency letter dated February 17,1983, with L

enclosures thereto.

6.

Federal Emergency Management Agency renewal application for Materials License No. 08-01297-06, dated August 10,1992 with enclosures thereto.

J l

4S/W8pgyo -

j

(

n

..-,~ ~.

- -. - - - - - - - - ~

wx~

PAGE1 NRC FORM 567 U.S. NUCLEAR REGULATORY COMMISSION I

REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send tNs request AND a copy of all reisted lettere/ applications and draw 6ngs to: The Sealed Source Safety Section, ATTN: CNef, OWFN Mail Stop 6 H3. Change the License Tracidng System milestone to 19 and assign to reviewer code I-5.

NOTE: Retain a copy of this request with the application and back0round files.

REQUEffER REGION / LOCATION:

li 11 Ill IV CV C HQ R LFDCB TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as appropriate)

APPucAnr3 NAME SOURCE REVIEW AMENDMENT OF

%/[//off h/jfgjj REGISTRATION SHEET mat CONTROL NUMBERm J

DEVICE REVIEW NWBER(S)

LETTER /APPUCA DA UCENSE NUMBERM CUSTOM REVIEW N

N b ~

~-

b//]/

~

6MMy c.. M /'t & y " h&# find Qf

,gggg4 S'

Soo toASLwls> 3e-4W7-z.

FOR SSSS USE ONLY CDtl-7W 7d'a, 7YY 754

$~d)I REVIEWER MODEL NUMBERS NUMBER ASSGNED DATE RECENED DATE ASSONED

/

DATE TO FEES TY, 0, ACTION -. th. - of - tv,.)

l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (98)

Np NEW NEW NEW t/ AMENDMENT AMENDMENT AMENDMENT AMENDMENT jo SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Specify)

TOTAL NUMBER OF NOTES gC[, L/4 k -

REVIEW HOURS NUMBER OF DEFICIENCY LETTERS l-NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY j NEW REGISTRATION -

J PRODUCT INACTIVE -

NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY

/

9A 98 9C U 90 AMOUNT RECEIVED CHECK NUMBER MATANN UPDATED t

Of,

{AOA p'd j

AS REQUIRED DATE OF CHECK l h"

'J p"

LOG

/

MATSYS UPDATED l

AS REQUIRED

' )(/v' DATE RETURN '

DATE APPROVED ay COMMENTS t

(/

NRC FORM $61 (&S3)

.; m.

Federal Emergency Management Agency L

r Washington, D.C. 20472 March 17, 1997 Mr. Steven Baggett Nuclear Regulatory Comcission U.S.

1 Sealed Source Safety Section i

Source Container and Devices Branch Division of Industrial and Medical Nuclear Safety, NMSS Washington, D.C. 20555-0001

Reference:

NRC License No. 08-01297-06 Docket No. 030-7130

Dear Mr. Baggett,

The Director of the Federal Emergency Management Agency (FEMA) made the decision to close the National Instrumentation Center (NIC) at the Mt. Weather Emergency Assistance Center (MWEAC), Bluemont, 1996.

Virginia, effective August 15, in the possession of FEMA at the NIC are in Radioactive Sources temporary storage, awaiting either the transfer to a properly licensed recipient or disposed of as radioactive waste.

sources owned by licensed recipient who possess radioactive or dispose of The FEMA will either retain possession of the sources, them as radioactive waste.

it is requested that the following Due to the closure of the NIC, registry numbers in our License be given inactive status:

e NR-283-D-101-S NR-283-S-102-S NR-283-D-105-S NR-283-D-106-S NR-283-D-110-S NR-283-D-111-S

.The following-registry numbers are inactive:

NR-283-D-801-S NR-283-D-802-S NR-283-D-803-S It is anticipated that the annual fees for the devices covered by each registry number will be frozen for FY 1998.

We are currently in the process of reconciling and updating our inventory Radioactive Materials (RAM) Data-Base to radioactive computerized currently own and possess and what material and devices have been transferred to licensed recipients reflect what we or disposed of as radioactive waste.

When completed, we will provide you with an updated inventory.

jY{$f$/Y

o L,

I would be happy to discuss any questions or concerns that you or your staff have regarding this letter.

I can be reached at (202) 646-2872.

Sincerely, S

0 tJ Vernon L. Wingert Chairperson, Radiation Control Committee (RCC) cc:

Elaine Chan (OGC)

I Robert P.

Fletcher, Jr.

(PT-SL)

Jose Cortes (FEMA RSO) l

.b

April 2,1997 ASSIGNMENT NUMBER: 97-23 to 97-28 Mr. Vemon Wingert Federal Emergency Management Agency 500 C Street S.W.

Washington, DC 20472

SUBJECT:

ACKNOWLEDGEMENT OF REQUEST FOR SAFETY EVALUATION

Dear Mr. Wingert:

This letter acknowledges the receipt of your March 17,1997, application that requested a safety evaluation and registration of various Models. We have performed a cursory review of your application and determined that enough information has been provided to allow a technical reviewer to initiate the evaluation process. Applications are assigned to technical reviewers on a first-in basis. Therefore your application will be assigned in tum. Please note that the technical reviewer may contact you to request information that was omitted from your application or to obtain clarification of technicalissues concerning your application. If you have any questions concerning the status of your application, please contact me at (301) 415-7857. Please reference the assignment number listed above in your questions or correspondence.

Please be aware that your request may be subject to the NRC's application fees in accordance with 10 CFR Part 170. Therefore, a copy of your application has been forwarded to the License Fee and Debt Collection Branch for approval of the fee category and amount.

If you have any questions conceming the fees associated with your application, please contact the License Fee and Debt Collection Branch at (301) 415-7554.

i Sincerely, l%

KimBeriy Randall, Registration Assistant Sealed Source Safety Section Medical, Acaderaic, and Commercial Use Safety Branch Division of Industrs! end Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards Distribution: