ML20153D419

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-382/88-19 on 880618-0731 & Notice of Violation
ML20153D419
Person / Time
Site: Waterford 
Issue date: 08/25/1988
From: Callan L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Dewease J
LOUISIANA POWER & LIGHT CO.
Shared Package
ML20153D424 List:
References
IEB-88-005, IEB-88-5, NUDOCS 8809020199
Download: ML20153D419 (3)


See also: IR 05000382/1988019

Text

,

___ __ _______

.

,

.

AUG 25 msg

i

In Reply Refer To:

J

Docket:

50-382/88-19

l

l

l

Louisiana Power & Light Company

ATTN:

J. G. Dewease, Senior Vice President

i

Nuclear Operations

l

317 Baronne Street

l

P.O. Box 60340

New Orleans, Louisiana 70160

Gentlemen:

This refers to the inspection conducted by Messrs. W. F. Smith, T. R. Staker,

and P. W. Michaud of this office during the period June 18 through July 31,

1988, of activities authorized by NRC Operating License NPF-38 for Waterford

Steam Electric Station Unit 3, and to the discussion of our findings with

Mr. N. S. Carns and other members of your staff at the conclusion of the

inspection.

Areas extmined during the inspection included enforcement followup on a quality

verification function inspection, monthly maintenance observation, allegation

followup, operational safety verification, monthly surveillance observation,

followup of previously identified items, followup on NRC Bulletin 88-05,

licensee event report followup, onsite followup of events, and plant status.

Within these areas, the inspection consisted of selective examination of

procedures and representative records, interviews with personnel, and

observations by the NRC inspectors. The inspection findings are documented in

the enclosed inspection report.

During this inspection, it was found that certain of your activities were in

violation of NRC requirements. Consequently, you are required to respond to

these violations, in writing, in accordance with the provisions of Section 2.201

of the NRC's "Rules of Practice," Part 2. Title 10, Code of Federal

Regulations.

One unresolved item is identified in paragraph 3 of the enclosed inspection

report.

We have also examined actions you have taken with regard to previously

identified inspection findings. The status of these items is identified in

paragraph 7 of the enclosed report.

The response directed by this letter and the accompanying Notice is not subject

to the clearance procedures of the Office of Management and Budget as required

by the Paperwork Reduction Act of 1980 PL 96-511.

b( 0

h(&

P

OK-

D:DRh

ACff'

RIV:R

RIV:RI

'RIV SRI

C:RPD/A

FEmerson

LJC[allan)/fj/88

\\

TStaker

PMichaud

WSmith

DChamberla in

( { /88

y /21/88

y /p/88

y/44/88

f /,' f/88

h'O

'

eso,o20199 esos:s

PDR

ADOCK 05000382

'

I

O

PDC

- __________________ _.

. _ _ _ _ _ _ _ _ _ _ _ _

O

,

.

Louisiana Power & Light Company

-2-

Should you have any questions concerning this inspection, we will be pleased to

discuss them with you.

Sincertly,

/s

L. J. Callan Director

Division of Reactor Projects

Enclosures:

1.

Appendix A - Notice of Violation

2.

Appendix B - NRC Inspection Report

50-382/88-19

cc w/ enclosures:

Louisiana Power & Light Company

ATTN:

G. E. Wuller, Onsite

Licensing Coordinator

P.O. Box B

K111ona, LA 70066

Louisiana Power & Light Company

ATTN:

N. S. Carns, Plant Manager

Nuclear

P.O. Box B

Killona, Louisiana 70066

Louisiana Power & Light Company

ATTN:

R. F. Burski, Manager

Nuclear Safety & Regulatory Affairs

317 Baronre Street

P.O. Box f1340

New Orlear<, Louisiana 70160

Middle South Services

ATTN: Mr. R. T. Lally

P.O. Box 6100

New Orleans, Louisiana 70161

Louisiana Radiation Control Program Director

bec:

see next page

-

_ _ _ _ _ _ _ _ _ _ _

.

.

e

,

!.

Louisiana Power & Light Company

-3-

bec to DMB (IE01)

bec distrib. by RIV

R. D. Martin, RA

  • Section Chief (DRP/A)
  • DRP

RPSB-DRSS

  • MIS System
  • Project Engineer, DRP/A
  • RSTS Operator
  • R. Hall
  • D. Wigginton, NRR Project
  • DRS

Manager

  • Lisa Shea, RM/ALF
  • RIV File
  • w/766

P. Michaud, Ft. St. Vrain

M. Emerson

,

L

<

+

l

l

l

l

l

,

-

-

, . . , - - .