' REGISTRY OF RADIOACTIVE SEALED. SOURCES AND DEVICES i
J SAFETY' EVALUATION OF DEVICE NO.: NR-300-D-844~-S DATE':
SEP 141988 pAag 1 op 4 l
DEVICE TYPE:
Radiographic Exposure Device I
h
\\
i 1
MODEL:
Century SA l'
l' I
MANUFACTURER / DISTRIBUTOR:
Gamma Industries, Inc.
- P.O. Box 2543 Baton Rouge, LA 70821 l
-l l'
SEALED SOURCE MODEL DESIGNATION:
Gamma Industries S-16 i
ISOTOPE:
MAXIMUM ACTIVITY:
i Iridium-192 100 curies (3.7 TBq)
Cobalt-60 100 millicuries (3.7 GBq)
Deplet'ed; Uranium Shielding, 17 kilograms (37 lb)
LEAK TEST FREOUENCY:
6 months l
l PRINCIPAL USE:
(A) Industrial.Ra'iography d
l'
-1 j.
CUSTOM DEVICE:
YES
'X NO l
9909230012 980914 l
l:
PDR RC N
l-SSD PDR-w..
1 e
6
~. +,
e
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE y
i NO.: NR-300-D-844-S DATE:
SEP 141988 PAGE 2 OF 4 4
DEVICE TYPE:
Radiographic Exposure Device t DESCRIPTION:
The device consists of aJdepleted' uranium shield and a polyurethane filler enclosed in a 1/8" (3.18 mm) steel case, consisting of.a right circular cylinder and two casts 1/4" (6.35 mm) end pieces. -The assembly is secured by heliarc welding.
A zircaloy "S"
tube extends through the device's shieldin;
. ass.
At one end is a lock box through which'the ocurce pigtail 'able and. male half of the quick disconnect-connect connector pr,.trude.
The lock box is the improved version that is used in the Gamma
' Century A unit.
The lock box is located at the bottom of the device.
At the top of the device, the source conduit is attached to a fitting-at the opposite end of the "S"
tube by a spring I
-loaded quick disconnect-connect connector arrangement after removing a protective screw cap.
The source tube may be of the transparent PVC'or-the more common opaque neoprene coated steel g
. type.
The' depleted uranium shield (approximately 37 pounds [17 kg]) is secured in pot **'c" by the two cast steel end pieces and is cushioned on'ite -; mmference within the device by polyurathane.
U_"A leather carrying.., 11e is attached to the upper steel end piece.
A teleflex drive cable arrangement with a hand crank is provided'for_ moving the source between the exposed and chielded
. positions from a remote location.
' The outside dimensions,of the device are 5-1/2" (13.97 cm) in diameter by 7-3/8" (18.73 cm) in height
?
.w e
p w.-.a
)g a
w-a
l' l
c REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES i '
SAFETY EVALUATION OF DEVICE l
L i
L NO.::NR-300-D-844-S DATER IEPI41000 PAGE 3 OF 4 l
l DEVICE TYPE:
Radiographic Exposure Device LABELING:
l The device bears the manufacturer's label which specifies that the device contains 37'lb. (17 kg) of depleted uranium.
The label ~also specifies the isotope, activity, date of calibration, A'
source serial ~ number, and states " Danger, Do Not Handle, Radioactive Material.
Notify Gamma ~ Industries, Baton Rouge, LLouisiana, or Civil Authorities."
~
v i
- EXTERNAL RADIATION' LEVELS:
f-TheLsource within.the device ~ is less than 4 inches from the
' device outer' surface.
Utilizing the maximum possession-quantity of iridium for this device L (i20 C1 (4.4. TBq)) and' cobalt
-(110 mci (4.07-GBq]) the.following dose: rates were obtained with a calibrated ioniza' tion chamber.
1 1
Source in Shielded Position-Ir-192 Co-60 mR/hr mR/hr a '.
6" (15.24 cm). from outer surf ace:
- 48"(highest) 50 10 (lowest) 21 e
-. b.
Surface of device:
190 (highest) 200 a
150 (lowest) 145 C.,
Handle:
=125
=125 LIMITATI'ONS AND/OR OTHER CONSIDERATIONS OF USE:
The~ manufacturer furnishes.an operating and maintenance manual which includes step-by-steplinstructions for using the exposure I
device and exchanging sources using the Gamma Industries Model C-4 source changer.
The operating instructions do not in
- themselves meet regulatory requirements concerning operating and j.
emergency procedures'for industrial radiography.
l
,~
]
F
-r
<T,-r
.,,--~v-e w
---1+t---
e w
~
- rv wn 5 1--------r er w
s
.. ~.
- ~ ~
L REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE l
l L
NO.:.NR-300-D-844-S DATE:
$[F 141999 PAGE 4 OF 4 1
. DEVICE TYPE:
Radiographic Exposure Device LIMITATIONS AND/OR OT' ER CONSIDERATIONS OF USE (Cont ' d) -
d 1
The license for radioactive material should include provision for 37 lb,-(17.kg) of depleted uranium.
' SAFETY' ANALYSIS
SUMMARY
The Model Century SA is device is no longer manufactured or distributed by' Gamma Industries, Inc. and Gamma Industries, Inc.
is.no longer in~ business.
Therefore, the registration certificate is being converted to an inactive registration certificate.
'The device was originally approved for licensing purposes by the Louisiana Division of Radiation Control.
NRC attempted to obtain
' copies of all information submitted by the registrant in support of the evaluation ~.
However, NRC could not locate all the
-information.
.Therefore, no safety evaluation of the device was performed as part of the conversion of the certificate to inactive status.
' ISSUING' AGENCY:
U.S. Nuclear Regulatory Commission
/
,/
SEP 141991S Date:
Reviewer:
/
John W. Lubinski l
hI+ A4 du Date:
Concurrence:
(.
Michele L.
Burg'ess p
t I'.
l
PAGEi NRC FORM 567 U. S. NUCLEAR REaULATORY COMMASION REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send tNs request AND a copy of all reisted letters /agigeenme and drawlnge to: The Sealed Source Safety Section, ATTN: CNef, OWFN Mail Stop 6 H3. Change the Ucense Tracidng System milestone to 19 and assign to reviewer code I-5.
NOTE: Retain a copy of tNe request with the application and background files.
REQUESTER REGION / LOCATION:
l1 U!!
lil IV V R HQ LFDCB TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as appropriate)
] SOURCE REVIEW AMENDMENT OF ME MA!L CONTRdL NUMeER(S)
'-~
75 //M I/)('" -
REGISTRATION SHEET
/97 77(/_
/
DEVICE REVIEW BER(S)
/
) ATE LETTER /
TION UCENSE NUMBER (S)
CUSTOM REVIEW Y/ k
/
~~
' p o. box 2345 Ba k Toucy i LA 7b521 FOR SSCS USE ONLY REVIEWER RS '
NUMBER ASSIGNED
/
b DATE RECEIVED DATE AS$aONED DATE TO FEES TYPE OF ACTION (Indicate the number of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPUCANT (CUSTOM)
SOURCE (9C)
DEVICE (9A)
SOURCE (90)
DEVICE (90)
NEW NEW NEW NEW
] AMENDMENT
, AMENDMENT AMENDMENT AMENDMENT
_j NO SAFETY EVALUATION REQUIRED d
UCENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Spec #r)
TOTAL NUMBER OF NOTES REVIEW HOURS g[/ -
h/,,/f NUMBER OF DEFICIENCY LETTERS
[gg & ' g hd d V' I/[.
NUMBER OF DEFICIENCY CALLS FOR BILLJNG PURPOSES ONLY j NEW REGISTRATION -
_j PRODUCT INACTIVE -
NAME CHANGE ADDRESS CHANGE ADO TO BILUNG REMOVE FROM BILLING FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY l
t 7 9A na w
nw
/
AMOUNT RECETVED CHECK NUMBER MATANN UPDATED gt
- AS REQUIRED gje g g sw JggYSygTED
.TER - N 3
4 M b6
.TE g
l COMMENTS b'
l-A 0 S0 0 D) 03tt,4 5,l-31 T& JI,)A IS 3.b,.
NRC FORM Se7 (e-e3)
NO
SEP 141998 MEMORANDUM TO:
Sandra Kimberley, License Fee Analyst Office of the Chief Financial Officer FROM:
Seung J. Lee, Mechanical Engineer Material Safety Branch Division of Industrial and i
Medical Nuclear Safety, NMSS
SUBJECT:
INACTIVE STATUS: GAMMA INDUSTRIES, INC.
ASSIGNMENT NUMBERS 98-44, 98-45, 98-64, & 98-65 We have converted the registration certificates identified in column 1 of the table in the attachment to inactise status and have assigned them the new registration certificate 1
numbers identified in coltimn 2 of the table. If you have any questions, please contact me at 415-5787 or Mr. John Lebinski at 415-7868.
Attachment:
As stated i
Distribution:
lMNS r/f SSD-98-44, -45, -64, -65 NE01 Registratio 1 Certificates listed in Attachment DOCUMENT NAME: C:\\ FILES \\SSDS\\ GAMMA 2.IND Te r.c.iv.. copy or ini. o oam.nt. indic.i. in in. no.: c. coo 4tnout it.en.nii.ncio.ur.
a - copy witn.it.enm.nis.ncio.ur.
n - no ecov OFFICE IMSB IMSB j y d
NAME Slee/jl
(,/
JLubinsly DATE 09/Jbl98 09//q/98
'~"A OFFICIAL RECORD COPY i
l 1,,e, h:
5 GAMMA INDUSTRY, INC. REGISTRATION CERTIFICATES OLD NUMBER NEW NUMBER NR-300-S-101-U NR-300-S-836-S LA 300 S-102-U NR-300-S-837-S LA-300-D-103-U NR-300-D-838-S LA-300-D-104-U NR-300-D-839-S LA-300-D-105-U NR-300-D-840-S LA-300-D-106-U NR-300-D-841-S LA-300-S-107-U NR-300-S-842 S LA 300-D-108-U NR-300-D-843-S LA-300-D-109-U NR-300-D-844-S LA-300-D-110 U NR-300-D-845-S LA-300-D-111-U NR-300-D-848-S LA-300-D-112-U NR-300-D-847-S LA-300 D-113-U NR-300-D-848-S LA 300-D-114-U NR-300-D-849-S LA-300-D-115-U N R-300-D-850-S LA 300-D-147-S NR-300-D-879-S LA 300-S-148-S NR-300-S-880-S LA 300-S-149-S NR 300-S-881 S LA-300 D-150-S NR-300-D-882-S LA 300-S-151-S NR-300-S-883-S LA-300-D-152-S NR-300-D-884 S LA 300-D-153-S NR-300-D-885-S LA-300-D-154-S NR-300-D-886-S LA-300-S-155-S NR-300-S-887-S l
ATTACHMENT i
-