ML20151W166

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 880126-29.Violation Noted: Equipment Qualification Files J-601,J-313 & E-171 Contained Deletions,Whiteout Changes of Original Text Not Initiated or Dtd
ML20151W166
Person / Time
Site: Hope Creek 
Issue date: 04/27/1988
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20151W163 List:
References
50-354-88-03, 50-354-88-3, NUDOCS 8805030315
Download: ML20151W166 (1)


Text

.

-~

2.

.q.

APPENDIX A

.l NOTICE OF VIOLATION Public Service Electric and Gas Company Docket No. 50-354-

' Hope Creek Unit 1 Nuclear Plant License No. NPF-57 As a result of the equipment qualification inspection of January 26-29, 1988 and in accordance with NRC Enforcement Policy (10 CFR 2, Appendix C) the following violation has been identified:

10 CFR 50, Appendix B, Criterion V states, in part, that: "Activities affecting quality shall be accomplished in accordance with instructions, procedures..."

i Procedure number VPN-NSP-07, Section 8.2.1 states, in part, that:

"The use of whiteout and/or obliteration is not permitted on Quality Assurance records. Changes shall be made by a single line drawn through the item with new information written in, initialed and dated."

Contrary to the above, on January 29, EQ file numbers J-601, J-313 and E-171 contained deletions, whiteout changes of the original text that had not been initialed or dated.

This is a Severity Level V violation.

(SupplementI)

Pursuant to the provisions of 10 CFR 2.201, Public Service Electric 8iGas Company is hereby required to submit to this office within_ thirty days of the date of the letter which transmitted this Notice, a written statement or i

explanation in reply, including: (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Where good cause is_shown, consideration will be given to extending this response time.

1 f

i l

i E

OFFICIAL RECORO CCPY IR HC 88 0004.0.0

(

04/20/88 8805030315 880427 f

PDR ADOCK 05000354

Q DCD i