Monthly Operating Rept for Jul 1988 for Wolf Creek Generating Station
ML20151V321
Person / Time
Site: Wolf Creek 
Issue date: 07/31/1988
From: Mike Williams, Withers B
WOLF CREEK NUCLEAR OPERATING CORP.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
WM-88-0206, WM-88-206, NUDOCS 8808220233
Download: ML20151V321 (7)


Text

>a,.

2-.

y

.a s.=.,

Attachment:

to WM 88-0206'

~

./

.g.

N WOLF CREEK NUCLEAR OPERATING CORPORATION 9

1 WOLF CREEK GENERATING STATION MONTHLY OPERATING REPORT MONTH:

July YEAR:

1988 1

Docket No.:

50-482 Facility Operating License No.: NPF-42 Report No.

41 3

i 1

.i I,

4 i

1 4

].

Prepared by:

s a

Merlin G. Williams 1

1 i

!1 4

4 8808220233 880730 efLV PDR ADOCK 05000482 o

}

R PDC r

s:

4

..r

' Attachment to WM'88-0206 r

SUFt%RY W e following report highlights the operating experience of Wolf Creek Generating Station for the month.of July, 1988. This report is being provided pursuant to Technical Specification 6.9.1.8.

I.

SUbt%RY OF OPERATING EXPERIENCE We unit operated near 100 percent power throughout the month. On

. July 31, 1988, Wolf Creek Generating Station completed 165 days of continuous operation.

II.

MAJOR SAFFJTY RELATED MAINTENANCE ACTIVITIES 1.

A coupling and a 90 degree elbow were replaced downstream of a letdown orifice throttle valve in the Chemical and Volume Control System.

2.

Cracks in the body to bonnet seal welds on two steam generator tube sheet drain valves were ground out and rewelded.

3.

Replaced printed circuit boards in two Reactor Coolant System temperature instruments and one Main Steam pressure instrument.

4.

Replaced a pressure transmitter on the hydraulic system for a Main i

Feedwater Isolation Valve.

5.

Replaced a potentiometer and a bistable'in the Load Shed/ Emergency

[

Load Sequencer System.

s

~

i t

1 1

i Wolf Creek Generating Station Monthly Operating Report July 1988 j

Page 1 of 5

~ -

Attachment to WM 88-0206 OPERATING DATA REPORT DOCKET NO.

50-482 WOLF CREEK GENERATING STATION WOLF CREEK NUCLEAR OPERATING CORPORATION DATE 08-01-88 COMPLETED BY M. Williams TELEPHONE 316-364-8831 OPERATING STATUS 1.

Reporting Period:

July, 1988 Gross Hours in Reporting Period: '744 2.

Currently Authorized Power Level (tMt): 3411 Max. Depend. Capacity (!Me-Net): 1128 Design Electrical Rating (:Me-Net):

1170 3.

Power Level to Whidi Restricted (If Any) (Mwe-Net):

N/A 4.

Reasons for restriction (If Any):

N/A This Month Yr to Date Cumulative 5.

Number of Hours Reactor was Critical 744.0 4507.6 19974.1 6.

Reactor Reserve Shutdown Hours 0.0 89.5 339.8 7.

Hours Generator on Line 744.0 4354.4 19557.5 8.

Unit Reserve Shutdown Hours 0.0 0.3 0.0 9.

Gross Thermal Energy Generated (tWi) 2,531,412 14,669,829 64,096,183 I

10. Gross Electrical Energy Generated (thH) 871,220 5,114,679 22,303,570
11. Net Electrical Energy Generated (tWi) 836,590 4,894,835 21,265,301
12. Reactor Service Factor 100.0 88.2 78.3
13. Reactor Availability Factor 100.0 89.9 79.6 4
14. Unit Service Factor 100.0 85.2 76.7
15. Unit Availability Factor 100.0 85.2 76.7
16. Unit Capacity Factor (Using MEC) 99.7 84.9 73.9
17. Unit Capacity Factor (Using Design !Ee) 96.1 81.9 71.2
18. Unit Forced Outage Rate 0.0 12.8 6.6
19. Shutdowns Scheduled Over Next 6 Months (Type, Date, an3 Duration of each):

Refueling, September 29, 1988, 65 days.

20.

If Shut Down at Erd of Report Period, Estimted Date of Startup:

N/A Wolf Creek Generating Station Monthly Operating Report July 1988 Page 2 of 5 i

Attachment to WM 88-0206

+

AVERAGE DATLY UN1T POWER LEVEL DOCKET NO.

50-482 WOLF CREEK GENERATING STATION WOLF CREEK NUCLEAR OPERATING CORPORATION DATE 08-01-88 COMPLETED BY M. Williams TELEPHONE 316-364-8831 MONTH July, 1988 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (tiie-Net)

(tife-Net) 1 1131 17 1125 2

1133 18 ____

1107 3

1134 19 1106 4

1131 20 1107 5

1128 21 1115 6

1125 22 1125 7

1126 23 1126 8

1126 24 1126 9

1128 25 1124 10 1129 26 1124 11 1126 27 1125 12 1128 28 1125 j

13 1125 29 1128 14 1123 30 1128 i

15 1122 31 1127 16 1125 l

Wolf Creek Generating Station Monthly Operating Report July 1988 Page 3 of 5

Attachment to WM 88-0206 l

UNIT SliUTDOWN AND POWER REDUCTIONS DOCKET NO.

50-482-WOLF CREEK GENERATING STATION-WOLF CREEK NTLEAR OPERATING CORPORATION l

DATE 08-01-88 COMPLETED BY M. Williams REPORT M0tTril July, 1988 TELEPHONE 316-364-8831-TYPE METHODS SIIUTPING l

F: FORCED DURATION REASON DOWN THE RF1CIOR CORRTTIVE ACTIONS /COPHENTS l

No Date S: SCHEDULED (HOURS)

(1)

OR REDUCING POWER (2) l l

l l

l SIDWmRY: There were no shutdowns or power reductions this month.

1 (1)

REASON: A: EQUIPME!TP FAILURE (EXPLAIN)

E: OPERATOR TRAINING AND LICENSE EXAMINATION (2) METHOD:

1.

MANUAL B: MAltfrENANCE OR TEST F: ADMINISTRATIVE 2.

MANUAL SCRAM-l l

C: REFUELING G: OPERATIONAL ERROR (EXPLAIN) 3.

AUTOMATIC SCRAM l

D: REXXJLATORY RESTRICTION' H: OTHER (EXPLAIN)

.4.

OTilER (EXPLAIN)

I i

l l

l Wolf Creek Generating Station Monthly Operating Report l

July 1988 j

~ -

Page 4 of 5 4

' Jttachment to WM 88-0206

)

WOW CREEK NUCLEAR OPERATING CORPORATION

)

WO W CREEK GENERATING STATION UNIT NO. 1 MONIH July, 1988 SUFfiARY OF OPERATING EXPERIENCE Listed below in chronological sequence is a sunmary of operating experiences for this month which.yequired load reduction or resulted in significant non-load related incidents.

DATE TIME EVENT July 01, 1988 0000 Unit in Mode 1, Power Operation i

~

l i

l 1

i P

4

i L

I i

I I

i l

i 1

Wolf Creek Generating Station i

Monthly Operating Report July 1988 Page 5 of 5 1

u l

1

4 8 WOLF CREEK

' NUCLEAR OPERATING CORPORATION Bart D. Wrthers President and Chet ExeoAve 04cer August 15, 1988 WM 88-0206 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station PI-137 Washington, D. C.

20555

Subject:

Docket No. 50-482:

July,1988, Monthly Operating Report Centlemen:

Attached is the July,

1988, Monthly Operating Report for. Wolf Creek Cenerating Station.

This submittal is being made in accordance with the requirements of Technical Specification 6.9.1.8.

Ver:

.uly yours,

^^_. _ - "

Bart D. Withers President and Chief Executive Officer BDW/jad Attachment cc: B. L. Bartlett (NRC), w/a D. D. Chamberlain (NRC), w/a R. D. Martin (NRC), w/a P. W. O ' Co nno r ( NRC), w/ a ( 2 )

P.O. Box 411/ Burtegeon, KS 66839 / Phone. (316) 364-6831 Auous cway tw movet I

-,,,. _ _. _ _