Clarifies Certain Aspects of Inadequate Core Cooling Instrumentation (Icci) Sys.Encl Figure Depicts Upgraded Sys for Unit 2.ICCI Sys for Unit 1 Will Be Upgraded to Same Configuration During Refueling Outage
ML20151U551
Person / Time
Site: Catawba  
Issue date: 02/05/1986
From: Tucker H
DUKE POWER CO.
To: Harold Denton, Youngblood B
Office of Nuclear Reactor Regulation
References
TASK-2.F.2, TASK-TM NUDOCS 8602110048
Download: ML20151U551 (3)


Text

Duxe Powen Go>mm P.O. IlOX 30180 CitAllLOTTE, N.O. 28242 HALB.Tt'CKER tris.pnowa vmm reassment (704) 07:D-4531 mwtaan enomsm February 5, 1986 Mr. Harold R.

Denton, Director Office of Nuclear Reactor Regulation U.

S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention:

Mr.

B. J. Youngblood, Project Director PWR Project Directorate No. 4 Re:

Catawba Nuclear Station Docket Nos. 50-413 and 50-414

Dear Sir:

On September 25, 1985, representative from the NRC Staff, Westinghouse Electric and Duke Power met at the Catawba site to review the implementation of inadequate core cooling instrumentation (ICCI) at Catawba.

The meeting was documented in a November 7, 1985 meeting summary by the Staff.

Comments on the meeting summary were submitted by my letter of January 8, 1986.

The purpose of this letter is to clarify certain aspects of the ICCI system.

The ICCI system is discussed in Section 1.9 of the Catawba FSAR in response to TMI Item II.F.2.

The system is described in terms of its three subsystems - Subcooling Margin Monitor (SMM), Core Exit Thermocouples (CET) and Reactor Vessel Level Indication System (RVLIS).

As shown on the attached fi gure, the ICCI System utilizes the Class IE Westinghouse microprocessor system, ICCM-86, to perform all three functions.

Inputs from the Reactor Coolant System are processed by the microprocessor system and displayed by the plant computer and the plasma display.

All three functions (SMM, CET and RVLIS) are displayed on both displays.

Also the plasma display trends SMM and RVLIS for the previous 30 minutes and trends the five highest CETs per train for the previous 40 minutes, p$b f/

  • t G602110040 G60205 PDR ADOCK 05000413 p

PDR L,,

Mr. H2rold R. Denton, Dir ctor February 5, 1986 Page Two The ICCI System shown on the attached figure depicts the upgraded system for Catawba Unit 2.

The ICCI System for Catawba Unit I will be upgraded to the same configuration during the first refueling outage.

Very truly yours,

/

Wb&

Hal B. Tucker ROS:slb Attachment cc:

Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 NRC Resident Inspector Catawba Nuclear Station

CATAWBA NUCLEAR STATION UNIT 2 ICCI SYSTEM OUTSIDE CONTAINENT og S

20 T/C StGN ALS*

UA ICHROMEL/ALUMEL WlRES o

lay-ygg

_ DAT A LINK TR AIN A RTO RVLIS captLL ARy CA8! NET I RTOS p

3 RYLIS D/P XuTR 3 RVLIS LEVEL uCB e

SIGNALS SIGN ALS RECORDER 2 HOT LEO TEVP PCS ICCM 86 SIGNALS t RCS PRESS PCS SIGNAL 3R S

L TO PLANT NON SAFETY I

SIONALS r COMPUTER L

^ $

STATUS SIGN AN NU N CI ATOR CA T2

{

20 T/C Sf 0N ALS

  • TO PL ANT t

COMPUTER

(

3 HYCR AULf C ISOL lg L{

3 $UBC00 LING

  • TO PLANT

/

SIONALS J

SIGNALS COMPUTER INSIDE CONTAINhENT

(

3 HYDR AULic ISOL

_ ];

{

3 RVLIS LEVEL - TO PL ANT

/

SIGNALS J

L SiONALS COMPUTER

{

3 SUBC00 LINO

  • TO PLANT TR AIN 8 L

SIONALS COMPUTER RCP 4 RCP STATUS

_ ],

[g" 20 T/C STON ALS

  • TO PLANT STATUS SgoNAL J

L COMPUTER

' ' ANNUNCIATOR

~

NON* SAFETY f RCS PRESS PCS S!0NAL N

TR AIN 8 T

2 HOT LEO TEVP CABINET I PCS SIGNALS

'h L[

3 RVLIS tp XMTR ICCM 86 StoNALS RTD "V'IS C##I"#"#

RTOS DAT A LINK 20 T/C 910N ALS

  • PLASWA (CHROMEL/ALUMEL WIREI

)l5 PLAY

  • MCB YlTALES I - Isolation
  • - Unit 2 Upgrade