April 18,1988

\\

Docket No. 50-298 Mr. George A. Trevors, Division l

Manager - Nuclear Support Nebraska Pubile Power District Post Office Box 499 Columbus, Nebraska 68601

Dear Mr. Trevors:

SUBJECT:

COOPER NUCLEAR STATION (CNS) PROCEDURES GENERATION PACKAGE (PGP)/ EMERGENCY OPERATING PROCEDURES (EOP) REVIEW l

(TACNO.44291)

In response to inquiries by your staff this letter advises you of the status of ou: PGP/EOP review for CNS.

Your August 22, 1986 reply to our January 20, 1986 request for additional infomation has been forwarded to our technical assistance contractor. The staff intends to complete its PGP/EOP review by conducting PGP/E0P inplementa--

l tion audit. You will be advised when such an audit is scheduled for CNS. Any additional requests for information will be addressed in the course of the audit.

You are requested to keep the staff informed of changes to your PGP/EOP program.

If you have any questions please contact me at 301-492-1336.

Sincerely,

/s/

William O. Long, Project Manager l

Project Directorate - IV l

Division of Reactor Projects - III, I

IV, Y and Special Projects cc: See next page DISTRIBUTION tDocket File NRC PDR Local PDR PD4 Reading

)

J. Calvo P. Noonan W. Long OGC i

E. Jordan J. Partlow ACRS (10)

PD4 Plant File W. O'Neill, RIY W.R.Bennett(Sr.Res.Insp.)

W. Kennedy I. Schoenfeld LTR NAME: COOPER TAC 44291 PD4/LA,lI{

PD4/PM L

PD4/D ///G PNoona WLonytb WR ah-JCalvo 04/p/88 04/g /88 04/#(/88 04////88 8804280455 880418 DR ADOCK O 28 j

k April 18,1988 4

Docket No. 50-298 Mr. George A. Trevors, Division Manager - Nuclear Support Nebraska Public Power District Post Office Box 499 Columbus, Nebraska 68601

Dear Mr. Trevors:

SUBJECT:

COOPER NUCLEAR STATION (CNS) PROCEDURES GENERATION PACKAGE PGP)/ EMERGENCY OPERATING PROCEDURES (EOP) REVIEW TAC NO. 44291)

Ir response to inquiries by your staff this letter advises you of the status of our PGP/EOP review for CNS.

Your August 22, 1986 reply to our January 20, 1986 request for additional information has been forwarded to our technical assistance contractor. The staff intends to complete its PGP/EOP review by conducting PGP/E0P inplementa-tion audit. You will be advised when such an audit is scheduled for CNS. Any additional reouests for infomation will be addressed in the course of the audit.

You are requested to keep the staff infomed of changes to your PGP/EOP progrem.

If you have any questions please contact me at 301-492-1336.

Sincerely,

/s/

William O. Long, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, V and Special Projects ec: See next page DISTRIBUTION Docket File NRC PDR Local PDR PD4 Reading J. Calvo P. Noonan W. Lon OGC ACRS (g )

E. Jordan J. Partlow 10 PD4 Plant File W. O'Neill, RIV W.R.Bennett(Sr.Res.Insp.)

W. Kennedy

1. Schoenfeld LTR NAME: COOPER TAC 44291 PD4/LA p(

PO4/PM L

JCalvo//M PD4/D PNoona E.cnpiib WR a 04/i%/88 04/g4/88 04/is/88 04//t/88

\\

/

UNITED STATES j

NUCLEAR REGULATORY COMMISSION o

j WASHINGTON, D, C. 20666

  • g

/

April 18,1988 Docket No. 50-298 Mr. George A. Tievors, Division Manager - Nuclear Support Nebraska Public Power District Post Office Box 499 Columbus, Nebraska 68601

Dear Mr. Trevors:

SUBJECT:

COOPER NUCLEAR STATION (CNS) PROCEDURES GENERATION PACKAGE (PGP)/ EMERGENCY OPERATING PROCEDURES (EOP) REVIEW (TAC NO 44291)

In response to inquiries by your staff this letter advises you of the status of our PGP/EOP review for CNS.

Your Aucust 22, 1986 reply to our January 20, 1986 request for additional information has been forwarded to our technical assistance contractor. The staff intends to complete its PGP/EOP review by cotiducting PGP/EOP implementa-tion audit. You will be advised when such an audit is scheduled for CNS. Any additional requests for information will be addressed in the course of the audit.

You are requested to keep the staff informed of changes to your PGP/EOP program.

If you have any questions please contact ine at 301-492-1336.

Sincerely, h

h, b % D.

William O. Long, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, V and Special Projects cc: See next page I

yp y

m 7

y

__c.-

~.

m.me,

\\

Mr. George A. Trevors Nebraska Public Power District Cooper Nuclear Station ec:

Mr. G. O. Watson, General Counsel Nebraska Public Power District P. O. Box 499 Columbus, Nebraska 68601 Cooper Nuclear Station ATTN: Mr. Guy R. Horn, Division Manager of Nuclear Operations P. O. Box 98 Brownville, Nebraska 68321 Dennis Grams, Director Nebraska Department of Environmental Control P. O. Box 98922 Lincoln, Nebraska 68509-89P2 Mr. Larry Bohlken, Chairman Nemaha County Board of Comissioners Nemaha County Courthouse i

1824 N Street Auburn, Nebrask 08305 Senior Resident Inspector U.S. Nuclear Regulatory Comission P. O. Box 218 Brownville, Nebraska 68321 Regional Administrator, Region IV U.S. Nuclear Regulatory Comission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Mr. Harold Borchart, Director Division of Radiological Health Department of Health 301 Cen+onnial Mall, South P. O. Box 95007 Lincoln, Nebraska 68509-5007 i