ML20151M243
| ML20151M243 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 07/26/1988 |
| From: | WOLF CREEK NUCLEAR OPERATING CORP. |
| To: | |
| Shared Package | |
| ML20151M241 | List: |
| References | |
| WM-88-0196, WM-88-196, NUDOCS 8808050051 | |
| Download: ML20151M243 (1) | |
Text
.,....
Attachment III to WM E8-0196 Page 1 of 1 "NEbON TURES M 2. M e M tution of fuel rods by filler rods consisting
- 5. 3 REACTOR CORE of Zircaloy - 4 or stainless steel or by vacancies may be made if justified FUEL ASSEMBLIES by a cycle-specific reload analysis.
5.3.1 The core shall contain 193 fuel assembi swItheachfuelassembi containing 264 fuel rods clad with Zircaloy-4 EactL fuel rod shall have a nominal active fuel length of 144 inches.
The initial core loading shall have a maximum nominal enrichment of 3.10 weight percent U-235. Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.50 weight percent U-235.
l CONTROL RO*., ASSEMBLIES 5.3.2 The core shall contain 53 full-length and no part-length control rod assemblies.
The full-length control rod assemblies shall contain a nominal 142 inches of absorber material.
All control rods shall be hafnium, clad with stainless steel tubing.
5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The Reactor Coolant System is designed and shall be maintained:
a.
In accordance with the Code requirements specified in Section 5.2
(
of the FSAR, with allowance for normal degradation pursuant to the
\\
applicable Surveillance Requirements, b.
For a pressure of 2485 psig, and c.
For a temperature of 650'F, except for the pressurizer which is
~
680 F.
VOLUME f
5.4.2 The total volume of the Reactor Coolant System, including pressurizer and surge line, is 12,135 1 100 cubic feet at a nominal T of 557 F.
- 5. 5 HETEOR0 LOGICAL TOWER LOCATION 5.5.1 The meteorological tower shall be located as shown on Figure 5.1-1.
8808050051 880716 PDR ADOCK 05000482 P
PDC WOLF CREEK - UNIT 1 5-6 Amendment No. 3,I6