ML20151L827

From kanterella
Jump to navigation Jump to search
Errata to Effluent & Waste Disposal Semiannual Rept,1986. Re Gaseous & Liquid Effluents for Jul-Dec 1986
ML20151L827
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 12/31/1987
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20151L829 List:
References
NUDOCS 8804220154
Download: ML20151L827 (4)


Text

!

Il0N STATION EFFLUEN1 AND WASTE OlSPOSAL SEMIANNUAL REPOR1 1986 GASEOUS EFFLUENTS - ELEVATED RELEASE B. Gaseous Effluents Released - Isotopes (continued) 8 P'S Units July August September R

ae Oua t r 3.

Particulate Releases Na-24 Ci 2.1 E -5 2.7 E-5 1.6 E-5 6.4 E-5 Mn-54

<LLO

<LLO

<LLD

<LLO Mn-56

<lLD

<LLO

<LLO

<LLO Co-58 Ci 4.5 E-8 3.5 E-8 1.2 E-7 2.0 E-7 Co-60 9.9 E-6 2.8 E-6

<LLO 1.3 E-5 Ci Br-82

<LLO

<lLD

<LLD

<tLD Rb-08 Ci 8.8 E-3 3.6 E-3 1.2 E-3 1.4 E-2 Sr-89

  • <LLO Sr-91 Ci

<LLO

<LLD

<LLD

<LLO Sr-92

<LLD

<LLO

<LLO

<LLD Nb-95

<LLO

<LLO

<LLO

<LLO Ci Mo-99

<LLD

<LLD

<LLO

<LLO Tc-99M 1.6 E-6 6.6 E-7 8.0 E-8 2.3 E-6

<LLO - No detectable activity above background

  • - Errata data to the Semi-Annual Report 5

0601R 8804220154 880209 0580A PDR ADOCK 05000295 R

DCD

t' ZION STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPOR1 1986 LIQUID EFFLUENTS UNIT 2

0. Liquid Effluents Released - Isotopes so op'S Units July August September p

e Ou tr Na-24 Ci

<LLO

<LLO

<LLO

<LLO Ar-41

<LLO

<LLO

<LLO

<LLO C r-51 Ci

<LLO

<LLO 3.1 E-2 3.1 E-2 Mn-54 3.7 E-5

<LLO 2.7 E-4 3.1 E-4 Co-57

<LLO

<LLO

<LLD

<LLO Co-58 2.1 E-3 1.4 E-3 6.3 E-2 6.7 E-2 Fe-59 8.6 E-4 2.6 E-4 7.7 E-4 1.9 E-3,l Co-60 C1 1.4 E-2 6.0 E-3 2.6 E-2 4.6 E-2 Kr-85 Ci

<LLO

<LLO

<LLO

<LLD Kr-88

<LLO

<lLD

<LLO

<LLD Sr-89

  • <LLO Sr-92

<LLO

<LLO

<LLO

<LLO Nb-95 Ci

<LLO

<tLO 6.5 E-4 6.5 E-4 Zr-95

<LLO

<LLO 4.6 E-4 4.6 E-4 Tc-99M

<lLD

<tLD

<LLD

<LLO

<LLO - No detectable activity above background

  • - Errata data to the Semi-Annual Report 11 0601R 0580A

.