Text
-
q
.
.
,
1
.
.
APR '0 8 1988
Docket:No.
50-334
Duquesne Light Company
ATTN: Mr. J. D. Sieber
Vice President
Nuclear
Post Office Box 4
Shippingport, Pennsylvania 15077
Gentlemen:
Subject:
Inspection Report No. 50-334/88-06
This letter refers to the routine inspection conducted by Mr. R. Winters of
this offi'ce on February 8-12, 1988 at the Beaver Valley Power Station,
.
Unit 1 in Shippingport, Pennsylvania.'Mr. Winters discussed the results of the
inspection with Mr. J. Crockett of your staff at the conclusion of the
. inspection.
Areas examined during this inspection are described in the NRC Region I
Inspection Report which is enclosed with this letter. Within these areas,
the inspection consisted of selected examinations of-procedures and
representative records, interviews with personnel, and observations by the
inspector.
Within the scope of this inspection, no violations were observed.
No reply to this letter is required. Your cooperation with us in this
matter is appreciated.
Sincerely,
Original Signed By:
Jacque P. Darr
,
!
William V. Johnston, Acting Director
i
Division of Reactor Safety
/
'
Enclosure: NRC Region (Inspection Report No. 50-334/88-06
b
1
0FFICIAL RECORD COPY
IR BV1 88-06 - 0001.0.0
03/08/88
~
8804200074 880408
ADOCK 05000334
Q
J
.
.
,
.
.
,
Duquesne Light Company
2
cc w/ encl:
H. M. Siegel, Manager, Nuclear Engineering Department
C. E. Ewing, QA Manager
W. S. Lacey, Plant Manager
R. Druga, Manager, Technical Services
R. Martin, Manager, Regulatory Affairs
J. Crockett, Senior Manager of Nuclear Operations
N. R. Tonet, Manager, Nuclear Engineering & Construction Unit
Public Document Room (PDR)
local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
HRC Resident Inspector
Commonwealth of Pennsylvania
bec w/ encl:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o encl)
Section Chief, DRP
F. Young , SRI, BV- ?
P. Tam, LPM, NRR
Robert J. Bores, uRSS
C. Y. Cheng, NRR
C. McCracken, NRR
I
I
RI:DRS
RI:DRS
RI:DRS
,Vinters/geb/rw
Strosnider
Durr
%%
3/ I/88
3/ 14 /8.8
$'/6 /88
0FFICIAL RECORD COPY
IR BV1 88-06 - 0002.0.0
02/29/88
i
j