DESIGN FEATURES

5. 3 REACTOR CORE FUEL ASSEM8 LIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel assembly containing a maximum of 236 fuel rods clad with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 grams uranium.

The initial core loading shall l

have a maximum enrichment of 2.91 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.0 weight percent U-235.

l CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element assemblies.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The Reactor Coolant System is, designed and shall be maintained:

a.

In accordance with the code requirements specified in Section 5.2 of the FSAR with allowance for normal degradation pursuant of the applicable Surveillance Requirements, b.

For a pressure of 2500 psia, and For a temperature of 650 F, except for the pressurizer and surge line c.

which is 700 F.

VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11,800

+600, -0 cubic feet at a nominal T of 582.1*F.

avg 5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.

8807270055 880718 PDR ADOCK 05000382 P

PNU WATERFORD - UNIT 3 5-5 AMENDMENT NO. 7

O s

4

  • b O

e NPF-38-84 ATTAC10ENT B NS90004AA

DESIGN FEATURES 5.3 REACTOR CORF FUEL ASSEM8 LIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel assembly containing a maximum of 236 fuel rods clad with Zircaloy-3 Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 grams uranium.

The initial core loading shall l

have a maximum enrichment of 2.91 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of weight percent U-235, l

St /

CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element assemblies.

5.4 REACTOR COOLANT SYSTEM DESIG.'l PRESSURE AND TEMPERATURE 5.4.1 The Reactor Coolant System is, designed and shall be maintained:

a.

In accordance with the code requirements specified in Section 5.2 of the FSAR with allowance for normal degradation pursuant of the applicable Surveillance Requirements, b.

For a pressure of 2500 psia, and For a temperature of 650*F, except for the pressurizer and surge line c.

which is 700 F.

VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11,800

+600, -0 cubic feet at a nominal T f 582.1*F.

avg 5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.

i WATCRFORD - UNIT 3 5-5 AMENDMENT NO. 7

.