MC-1 SHOREHAM NUCLEAR P0k'ER STATION PLANT SPECIFIC TECHNICAL GUIDELINES PSTG #8 STEAM COOLING REVISION NO: 0 9!? C[p 7 PREPARED BY:
J j
DATE:
- d [ /fh'7_
REVIEk'ED BY:
[
[
f
(/
DATE:
- /J!/
OPERATING ENGINEER APPROVAL DATE:
mkt ii bbb G807250163 08071D PDR ADOCK 05000322 r
PNV 6
i SHOREHAM NUCLEAR POWER STATION Plant Specific Technical Guidelines Contingency #3 Steats Cooling EPG Step:
...ifirm initiation of IC.
~..
If while executing this step Emergency RPV Depressurization is required. RPV water level,cannot be determined, or any system, injection subsystem, or alternate injection subsystem is lined up for injection with at least one pump running, enter (procedure developed from Contingency #2].
SNPS PSTG Stept Non2 Justification for Differences / References Peletr> -*- ? pertaining to IC.
(N/A to SNPS)
In marging Steam Cooling into Contingency #1, the necessity for this override is elininated. All of these actions are covered within Contingency fl.
PSTG #8 Rev. O Page 1
1o.
SHORENAM NUCLEAR POWER STATION Plant Specific Technical Guidelines Contingency f 3 Steam Cooling l
EPG Step:
If IC cannot be initiated:*
C3-1.1 When RPV water level drops to [. -208 in. (Kinimum Zero-Injection RPV Vater Level)] enter (procedure developed from Contingency #2]
SNPS PSTG Step:
None Justification for Differences / References The above step is contained within C1-3.2 Minimum Zero Injection RPV water level: NED Appendix C Calculation C-NAD-270.