.J SHOREHAM NUCLEAR POWER STATIO?j PLANT SPECIFIC TECHNICAL GUIDELINES PSTG #5 RADI0 ACTIVE RELEASE CONTROL REVISION NO: 1 PREPARED BY:

A/

DATE:

8 2 7 If b[wl/ I')hw DATE:

48 88 REVIEWED BY:

OPERATING ENGINEER APPROVAL:

A'u DATE:

3/tf///

m u.

/

ho[j05000 app 0G0715 PNO

{}& \\\\

I )) l I

L t

g ullu tui, us.

e SHOREHAM NUCLEAR POWER STATION Plant Specific Technical Guidelines Radioactivity Release Control Guideline EPG Step:

PURPOSE The purpose of this guideline is to limit radioactivity release into areas outside the primary and secondary containments.

SNPS PSTG Step:

The purpose of this guideline is to limit radioactivity release into areas outside the primary and secondary containments.

Justification For Differences / References N/A PSTG #5 Rev. 1 Page i

SHOREHAM NUCLEAR POWER STATION Plant Specific Technical Guidelines Radioactivity Release Control Guideline EPG Step:

ENTRY CONDITIONS The entry condition for this guideline is:

o Offsite radioactivity release rate above the offsite release rate which requires an Alert.

SNPS PSTG Step:

ENTR'Y CONDITIONS The entry condition for this guideline is:

o Offsite radioactivity release rate sbove the offsite release rate which requires an Alert.

Justification for Differences / References N/A

.i PSTG #5 Rev. 1 l

Page 2

Ne u SHOREHAM NUCLEAR' POWER STATION Plant Specific Technical Guidelines Radioretivity Release Control Guideline T

.EPG Step:

8 OPERATOR ACTIONS l

f f

If while executing the following steps turbine building HVAC is shutdown (or isolated due to high radiation), restart t

turbine building HVAC, defeating isolation ir.terlocks if nacessary.

SNPS PSTG Step:

OPERATOR ACTIONS

<l If while executing the following steps turbine building HVAC

~

is shutdown or in the recirculation mode, restart tutoine building HVAC, and d' rect its discharge to the station ventilation exhaust.

Justification for Differences / References Tha SNPS Turbine Building HVAC system does not isolate on high radiation or any other cccident signal. As long as normal power is available, the HVAC system will continue to-operate after an accident. The system may be operated in the recirculation mode during plant shutdown, during which it does not discharge to the station vent.

If this were the case upon entry into this guideline, direction la added as to how the systsa is to be realigned from that mode.

Turbine Building HVAC system: FSAR section 9.4.4 and SP 23.419.01.

PSTG #5 Rev. 1 Page 3 i

'~

3 SHORERAM NUCLEAR POWER STATION

[

Plant Specific Technical Guidelines Radioactivity Release Control Guideline EPG Step:

RR-1 Isolate all_ primary systems that are discharging into areas outside the primary and secondary con-tainments except systems required to assure adequate core cooling or shut down the reactor.

SNPS PSTG Step RR-1 Isolate all primary systems that are discharging into areas outside the primary and secondary con-tainments except systems required to assure adequate

-core cooling or shut down the reactor.

J.sd P'

. for Differences / References N/A P.'TG #5 Rev. 1 Page 4

[,9 -

SHOREHAM NUCLEAR POWER STATION Plant Specific Technical Guidelines Radioactivity Release Control Guideline

-EPG Step:

RR-2 When offsite radioactivity release rate approaches or exceeds the offsite release rate which requires a General Emergency but only if a primary system ir discharging into an area outside the primary and secondary containments, FMERGENCY RPV DEPRESSURIZATION IS. REQUIRED; enter [ procedure developed from the RPV Control Guideline] at (Step RC-1] and execute it concurrently with this procedure.

,SNPS PSTG Step:

RR-2 When offsite radioactivity release rate approaches or exceeds the offsite release rate which requires a General Emergency but only if a primary system is discharging into an area outside the primary and secondary containments, EMERGENCY RPV DEPRESSURIZATION IS REQUIRED; enter procedure developed from the RPV Control Guideline at Step RC-1 and execute it concurrently with this procedure.

Justification for Differences / References N/A l

l l

PSTG #5 Rev. 1 Page 5 L