4 NUMBER REVISION PAGE WM-01I g

{

11 1

7 TITLE Soap Bubble 1.cak Test LN Technologies Corporation

)

TECHNOLOGIEG Type A Shipping Cask l

conpon ATION O

COPYRIGHT C 1987 BY LN TE'. 40LOGIES CORPORATION ALL RIGHTS RESERVED. NO PART OF THIS DOCUMEf T MAY OF REPRODUCEO OR TRArdM:TTED IN ANY FORM OR BY ANY MEANS. ELECTRONIC OR. 4ECHANICAL,8NCLUDING PHOTOCOPYtNG. hSCORDING OR BY ANY INFORMATION STORAGE AND RETRIEVAL SYSTEM.WITHCUT PERMISSION IN WRll'NG FROM LN TECHNOLOGIES CORPOR ATION. EXCEPT FOR STRICTLY CONTROLLED DISTRIBUTION, FOR t VALUA TION PURPOSES w

f.

hV. f.f/{

hL Q.

gg b f~l~ g $

?_ - _ '..

?

)tfh G

W.Frazer

[/)t &

F. Hush J.. Moon o v 4 hh _R,Nnit_. 19 k R EV.

ORIGINATOR DATE CliECKED DATE OA DATE MANAGER DATE 8807250073 800701

- ----__ --._._~.-__ -._. _._._...__.___ _ ____._._

PDR ADOCK 07109073 PDR C

1

i i

l

tao, REVISION PAGE WM-011 11 2 of 7

(

l O

TABLE OF CONTENTS i

Page l

1.0 PURPOSE 3

l

^

i l

2.0 APPLICABILITY 3

i i

3.0 DEFINITIONS 3

4.O REFERENCES 3

i l

5.0 RESPONSIBILITIES 3

t 6.0 EQUIPMENT 3

7.0 PROCEDURE 4

i O j

8.0 ACC5:PTANCE CRITERIA 4

i 9.0 RECORDS 5

j

)

i i

i Figure 1 - Tent Performance Form 6

i e

s i

)

1

  • W*

m Mer'mwth h

-e.

1 k

NO.

REVISION PAGE

.WM-Oll H

3 of 7 j'

1 9 1.0' PURPOSE This procedure states.the requirements for performing a Low i

Pressure Soap Bubb] c Leak Test for LN Type A shipping casks. -The fabrication contractor shall submit for approval detailed leak test procedures.

The purpose of this test will be to check the integrity of welds, threaded fittings, flanges and any other joints where pressure tests below 8 psi are adequate tu meet contractural/ functional requirements.

2.0 APPLICABILITY l

This test shall be performed before painting on all LN Technologies Type A chipping casks prior to acceptance from a fabricator.

Additionally, the test shall be performed yearly as a verification of gasket and gasket seating surfaces integrity.

This soap bubble leak test is sensitive for leak testing where a sensitivity of no greater than 30-3 atm.cm3/sec is required.

3.0 DEFINITIONS 1

None

4.0 REFERENCES

4.1 ANSI N14.5, 1977 - American National Standards for leakage tests on packages for shipment of rad io' ctive mat orial s.

a 4.2 Code of Federal Regulation (CFR) Title 10 Part 71 f

,..----,- -.,-..-~ -.,..-

l^

L i

l REVISION PAGE NO.

j WM-Oll H

4 of 7 I

~J l

f S.O RESPONSIBILITIES f

Quality Assurance Manager or his designee -

shall witness the

~

performance of the applicable leak test and sign the Test Performance Form (Figure 1).

i d

q 6.0 EQUIPMENT 1

i 1

The following equipment is required for a Low Pressure Soap Bubble Test.

6.1 Air Supply - A standard shop compressor or bottle compressed

]

air capable of pressurizing the tested cavity to 8 to 10 7-psig shall be utilized.

O 6.2 Gauge - A properly calibrated gauge capable indicating 0

- 15 psi range with an accuracy of + 2% of trm indicated reading shall be utilized.

1-i 6.3 Bubble Test Solution - A leak indicating solution equivalent to the following shall be utilized:

Dasco-Kloon Leak-Finding Compound #3183 D.

A.

Stewart Oil Company 2727 S.

Gray Street Chicago, Illinois 60623 SNOOP Liquid Leak Detector NUPRO Company 4800 East 345th Street Willoughby, Ohio 44094 6.4 Relief Valve - A relief valve set and checked at 10_ percent over maximum pressurization pressure.

b)

C' 7.0 PROCEDURE 7.1 The test shall be conducted by LN QA approved personnel.

=. -

7.__

.. ___ _ - _._~.. __ _. _ __. _. _ _ _ _ _ _..______ ________ _ _ _._._. _ _ _ _ _ _ _ __

~_

j<

6 No.

' REVISION PAGE-WM-011 H

S of. 7 2

,~

f J

i k

7.2 The item shall be leak tested with all lids, gaskets,' plugs, valves,.and fasteners in place and in the normal closed position.

The'only exception shall be the port or valve-utilized to pressurize the cavity.

1 t

CAUTION:

IF THE CASK LEAK TEST IS TO BE CONDUCTED WITH A LINER I

INSIDE THE CASK, LINER SHALL BE VENTED DURING Tile TEST 1

TO PREVENT LINER IMPLOSION.

i i

5 l

7.3 Pressurize the cavity to 8 psi +

1,

- O psi.

7.4 Close off or maintain pressure at pressurization location to hold specified pressure in cavity.

4 (m) 7.5 Apply the leak detecting solution to all gasketed areas, U

threads, seal welds, ports or valves by brush or spray.

Inspect for bubbles.

I 7.6 Conduct leak test for 5 minutes.

8.0 ACCEPTANCE CRITERIA 8.1 No bubbles shall be visable to the unaided eye during the S minute test.

4 8.2 If bubbles appear during the test, weld integrity, gasket condition, flange or lid tightness, valv'e position, plug 4

security, etc., shall be checked and the test rerun.

d

[]#

8.3 The results of the leak test shall be recorded on the Test L,

Performance Form (Figure 1).

8.3.1 Leak Test Pressure 1

1 m mt---

~

b NO.

fiEVISION PAGE WM-011 H

6 cf 7 f

l a

8.3.2 Gauge Model, P/N and S/N, as applicable 8.3.3 Leak Test Duration 8.3.4 Date 8.3.5 Results, including discrepancies and acceptai.cc 8.3.6 Test Gauge Range 9.0 RECORDS Test Performance forms shall be maintained by the Quality Assurance Program Manager for orne (1) year after completed usable life of tested item.

l t

,mm.

-m

,m,

.-,..m_,.m--y-,,___.,-,.y

,,.,,.-...,,,,,.~,,_..y%-,,

-. -m w..

cm-r.~...,

o NO.

REVISION PAGE 1

WM-011 H

7 of 7 1

i Figure 1 i

TEST PERFORMANCE Equipment Tested:

Date Tested:

Leak Test Pressure:

psi Gauge Information:

Model #

S/tl #

..ange Calibration Due Date Leak Test Duration minutes PASSED FAILED Discrepancies:

licxt Leak Test Due (< 12 months):

Date Signatures:

Test Performer

~

Date Quality Assurance Date

-