ML20151B711

From kanterella
Jump to navigation Jump to search
Advises That 880201 Rev 9 to Fsar,Consisting of Operational QA Plan,Consistent W/Provisions of 10CFR50.54(a) & Acceptable
ML20151B711
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 03/29/1988
From: Julian C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Wilgus W
FLORIDA POWER CORP.
References
NUDOCS 8804110158
Download: ML20151B711 (1)


Text

CMciol March 29, 1988 Florida Power Corporation

. W. S. Wilgus g'V ice President Nuclear Operations ATTN: Manager, Nuclear Licensing P. O. Box 219 Crystal River, FL 32629 Gentlemen:

SUBJECT:

CRYSTAL RIVER OPERATIONAL QUALITY ASSURANCE PROGRAM, FSAR SECTION 1.7 Your update of the Crystal River Unit 3 (CR3) Final Safety Analysis Report (FSAR), Revision 9, dated February 1, 1988, was received on February 5, 1988.

Section 1.7 of this document provides the current CR3 (Docket No. 50-302) quality assurance program required by 10 CFR 50.54(a).

We reviewed the following information relative to your submittal:

Quality Program Description FSAR Section 1.7 Quality Program Commitments FSAR Table 1-3 Quality Program Scope FSAR Section 1.64 FSAR Section 5 1 Our review of this material indicates that the CR3 quality assurance program continues to satisfy 10 CFR 50 Appendix B requirements and is therefore acceptable.

We appreciate your timely submittal regardir.g the information required by 10 CFR 50.54(a). If you have questions regarding this letter, please contact Mr. G. Belisle on (404) 331-5596.

Sincerely, 880411015e 880329 (Original signed by G. A. Belisle for)

NN Caudie A. Julian, Chief Operations Branch Division of Reactor Safety F. McKee, Director, Nuclear cc: [ Plant Operations  ;

g C. Simpson, Director, Nuclear l Site Support ]

/ '

bec:tMRC Resident Inspector l DRS Technical Assistant Document Control Desk State of Florida i

RI! RII RI RI I f d21)

RMoor :btm 0

GBeli le r1 njak Y

CJulidn 3/21/88 3/;3/88 3/g/88 3/d/88 0 i

11eI '