Monthly Operating Repts for Jan 1988
ML20149J374
Person / Time
Site: McGuire, Mcguire  
Issue date: 01/31/1988
From: Reavis J, Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8802230019
Download: ML20149J374 (14)


Text

__ _ _-.

OPERAiliu DATA REPORT DOCKET 50 369 DATE 21589 CPERAT!hs M TUS COMPLETEDBY J. A. Reavis TELEPHCNE 704/373 7567

1. Unit Naee Mc6UIRE 1

- - - ~ ~ - - - - -

2.ReportingPeriod: JANUARY 1,1988 JANUARY 31,1988

3. Licensed 'ne.ea1 Poser ( N t1:

3411

4. Nasepiate Rating (6ross Me):

1105e

-1 Notes eManeglate Raticg I

5. Cesign Electrical Rating (Net M e):

!!80 1 (Gross Me) calculated as

6. hasisas De;endable Capat.ity (6 toss N :):

.I 1450.000 MVA :.90 power I

7. Maxi m Dependable Capacity (Net W e):

!!29 I factor per Page ill, i

B. If Changts Occur in Capacity Ratings (ltres Nueber 3 Through 71 since Last i WURES-00!0.

I Report. Give Reasons:,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,

I,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,I

9. Pcner Level To Which Reitricted, If Any (Net M e1:,,,,,,,,,_,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
10. R e a s o n F o r R e s t r i e t t o n s, I f a r. y :,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,_,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,

l This Month Yr.-to-Date Cueulative i

11.HeursinReportingPeriod 744.0 744.0

'!4,072.0 i

12. Ngeber Of Hovrr Reactor Was Critical 729,4 729.4 37,593.0
13. Reactor Reserve ShuWonn Hours

. 0--

--0--

--0--

14. Hours 6ererator On Line 726.8 726.8 37,070.0 15.UnitReserveShutdownhours

. 0..

..o..

..o..

16. Gross Thereal Energy 6enerated (NH) 2,379.899 2,379,999 107,449,478 17.6tossElectricalEnergy6enerated(NH!

S29,803 829,993 37,225.960

19. Net Electrical Energy Generated (NH) 799,538 799,538 35,445,036
19. Unit !stvice Factor 97.7 97.7 69.6 l

E0.UnitAvailabilityFactor 97.7 97.7 49.6

21. Unit Capacity Factor (Using MDC Net) 95.2 95.2 56.1
22. Unit Capacity Factor (Using DER Net) 91.1 91.1 55.6 23.UnitForcedOutageRate 2.3 2.3 12.8
24. Stationns Sc W uled Over Next 6 Months (Type, Date, and Duration of Each):

.....Ng,e,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,_,,,,,,,,,,,,,,,_,,,,,,,,,,,,,

j

25. If Shut Dean At End Of Report Period. Esticated Date of Startups..........,,,,,,,,,,,,_,,,,,,,,,,_,,,,,,,,,,,,,,,,,

l

26. Units In fest Status (Prior to Coseercial Operation):

Forecast Achieved

/

INITIALCRITICAllif IN!i!ALELECTRICITY CCM"ERCIALOPERAi!0N b'f.

k; a 8802230019 880131 PDR ADOCK 05000369 3

R DCD

%~

w w.. _

'd" i

+

AVERA6E DAILY UNIT F0ER LEVEL 1

DOCKET NO.

50-369 UNIT

'McGuire i DATE February 15,1988 COMPLETED Of J. A. Reavis TELEPHONE 704-373-7567 I

MONTH JANUARY,1988 SAY AVERA6E DA!LY POE R LEVEL DAY AVERA6E DA!LY POWER LEVEL (NWE Net)

(MW-Net) 1007 17 1117 2

1115 18 1113 3

1115 19

!!!8

....... ~.................

4 till 20

!!36

....m......

4 5

1115 21 1137 6

1063 22

!!32 7

238 23 1134 8

683 24

.138 9

1099 25

!!35 10 1096 26 1134

!!!5 27 1136 12 1114 28 1136 13 1117 29 1136 i

1 14

!!!5 30 1141 15

!!!7 31 1137 16 1115

'l, f

UNIT SKUTDOWNS AND POWER REDUCTIONS DOCKET NO. _50:369___________

UNIT NAME _MCGUIRE_1.________

DATE _O2/15/@@_________

REPORT MONTH _____ January _19@@_

COMPLETED BY _J._A._REAVIS_____

TELEPHONE _(204):3Z3-2562___

Pege 1 of 2 (1)

(2)

(3)

(4)

(5)

R MET-E HOD T

A OF LICENSE N

Y S

SHUT EVENT SYS-CAUSE AND CORRECTIVE O

P DURATION O

DOWN REPORT TEM COMPONENT ACTION TO DATE E

HOURS N

R/X NO.

CODE CODE PREVENT RECURRENCE 1p 88-1-

1 S

F ZZ ZZZZZZ DISPATCHER REQUEST 2p 88-1-

1 F

A HB VALVEX

  1. 4 GOVERNOR VALVE PROBLEMS 3p 88-1-6 F

A HA GENERA GENERATOR VOLTAGE REGULATOR PROBLEMS 1

88-1-7 F

17.20 A

3 HA GENERA REACTOR TRIP DUE TO GENERATOR VOLTAGE REGULATOR PROBLEMS 4p 88-1-8 F

B IE INSTRU HOLD FOR NUCLEAR INSTRUMENTATION CALIBRATION B

IE INSTRU HOLD FOR NUCLEAR INSTRUMENTATION 5p 88-1-8 F

CALIBRATION 6p 88-1-8 F

A HB VALVEX M4 GOVERNOR VALVE PROBLEMS (1)

(2)

(3)

(4)

F Forced Reason:

Method:

Exhibit G - Instructions S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation'of Data B-Maintenance or test 2-Manual Scram Entry Sheets For. License <

C-Refueling 3-Automatic Scram Event Report (LER)

D-Regulatory Restriction 4-Other (Explain)

File-(NUREG-Ol61)

E-Operator Training & License Exaraination F-Administrative (5)

G-Operator Error (Explain)

Exhibit I - Same Source H-Other (Explain)

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

_59-369___________

UNIT NAME

_MCGUIRE_1________

DATE _O2L15LQ@_________

REPORT MONTH _____ January _19@@_

COMPLETED BY _J._A._REAVIS_____

TELEPHONE _17941-373-7567.,__

Ptge 2 of 2 (1)

(2)

(3)

(4)

(5)

R MET-E HOD T

A OF LICENSE N

Y S

SHUT EVENT SYS-CAUSE AND CORRECTIVE O

P DURATION O

DOWN REPORT TEM COMPONENT ACTION TO 1

DATE E

HOURS N

R/X NO.

CODE CODE PREVENT RECUPRENCE 7p 88-1-8 F

A HB VALVEX REMOVED #4 GOVERNOR VALVE FROM SERVICE 8p 88-1-9 F

A HB VALVEX

  1. 4 GOVERNOR VALVE PROBLEMS 9P 88-1-9 F

A HJ PUMPXX REMOVE

'C3' HEATER DRAIN PUMP FROM SERVICE I

10 P 88-1-9 F

A HB VALVEX

  1. 4 GOVERNOR VALVE PROBLEMS (1)

(2)

(3)

(4)

F Forced Reason:

Methods Exhibit G-Ins ^ ructions S Scheduled A-Equipment Failure (Explain) 1-Manual for PreparationLof Data 8-Maintenance or test 2-Manual Scram Entry Sheets For Licenser C-Refueling 3-Automatic Scram Event Report (LER)

D-Regulatory Restriction 4-Other (Explain)

File (NUREG-Ol61)

E-Operator Training & License Examination F-Administrative (5)

G-Operator Error (Explain)

Exhibit I - Same Source H-Other (Explain)

DOCKET NO:

50-369 UNIT:

McGuire i DATE:

02/15/88 NARRATIVE

SUMMARY

Month: January, 1988 McGuire Unit 1 began the month of January operating at 78% power, reduced in power per Dispatcher request. At 0952 on.01/01, the unit began increasing power, reaching 96% at 1300 the same day. The unit remained at 96% power, limited by problems with the No. 4 Turbine Governor Valve, until 1822 on 01/06, The when power was reduced to 76% due to generator voltage regulator problems.

reactor subsequently tripped at 0708 on 01/07, following a turbine trip caused T

by continued generator voltage regulator problems. The unit was returned to service at 0020 on 01/08, and following two power holds for nuclear instrumentation calibration, reached 95% power at 1745 on 01/08, limited in power by problems with the No. 4 Turbine Governor Valve. At 1815 on 01/08, power was reduced to 86% in order to remove the No. 4 Governor Valve from service. The unit was returned to 96% power at 0330 on 01/09. On 01/09 at 4

1601, power was reduced to 93% in order to remove the "C3" Heater Drain Pump from service. The unit then returned to 96% power where it operated until 1513 on 01/19, when the unit was returned to 100% power. The unit then operated at 100%

l full power for the remainder of the month.

i

i i

I i

MONTHLY REFUELING INFORMATION REQUEST i-3 i

i 1.

Facility name: McGuire, Unit 1 2.

Scheduled next refueling snutdown: November, 1988 3.

Scheduled restart following refueling:

January, 1989 l

4.

Will refueling or resumption of operation thereafter require a technical-specification change or other *.icense amendment? NJ l

If yes, what will these be?

i If no, has reload design and co~e configuration been reviewed by Safety

[

Review Committee regarding unreviewed safety questions? N/A 5.

Scheduled date(s) for submitting proposed licensing action and supporting information: N/A

+

6.

Important licensing considerations (new or different design or supplier, j

unreviewed design or performance analysis methods, significant changes in 4

design or new operating procedures).

j 7.

Number of fuel assemblies (a) in the core:

193 l

(b) in the spent fuel pool:

293 i

i 8.

Present licensed fuel pool capacity:

1463 l

j Size of requested or planned increase:

l i

9.

Projected date of last refueling which can be accommodated by present licensed capacity: August, 2010 i

6 I

I i

i i

?

i i

-i f

4 f

i DUKE POWER COMPANY DATE: February 15, 1988 l

f Name of

Contact:

J. A. Reavis Phone:

704-373-7567 l

i

}

i a

l I

i 1-l i

1 OPERAi!N6 DATA REPORT DOCKET 50-370 DATE 2 15-88 CFERATINGSTATUS COMPLETEDIf J. A. Reavis.

TELEPHONE 704/373 7567

1. Unit Nase: Mc6UIRE 2
2. Reporting Period: JANUARY 1, 1998-JANUARY 31,1988 3.LiteeseiTharea1Poeer(Mt1:

3411

4. Naseplate Rating (6ross Me):

1305e i Notes #Naseplate Rating I

5. Design Electrical Rating (Net Ne):

1180 1 (Gross Me) calculated as

.1

6. Mailege Dependable Capacity (6 toss Ne):

1 1450.000 MVA :.90 power 1

7. Marieuc Dependable Capacity (Net Me):

!!29 I factor per Page til, I

9. If Changes Occur in Capacity Ratings (! tees Nueber 3 Through 7) Since Last i NURE6-0020.

I Re; ort. 6iye Reasoes:,,,,,,,,,,,,,,,_,,,,,,,,,,,,,,,,..................

I,..........

....,,,,,,,,,,,,I

................................................................................................~........ ~........

9. Poaer Leye1 To Wh!ch R e s t r i c t e d, I f A n y ( Ne t Me 1 :,,,,,,,,,,,,,,,,,,,, _,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
10. Reasoa For Restrictiens, If any,,,,,,,,,,,,,,, _,,,,,,,,,,,,,,,,,,,,,,,,_, _,,,,,,,,,,,,,,, _,,,j,,,,,,,,,,,,,,,,

.......................................................................................... ~..............................

This Month Yr.-to-Date Cueulative 2

11. Hours in Reporting Period 744,0 744.0 34,368.0
12. Nuoter Of Hours Reactor Was Critical 726.1 726.1 25,172.0
13. Reactr Reserve Shutdoen Hours

. ~0~

~0~

14. hours fererator On-Line 721.2 721.2 24,!49.5
15. Unit Reserve Shutdoun Hours

--0 ~

. -0-.

4 16, 6 toss Thersal Energy Generated (NH) 2,375,936 2,375,936 79,615,987

}

17. Gross Electrical Energy 6ecerated (MH) 830,271 830,271 27,906,074
18. Net Electrical Energy Generated (MH) 799,386 799,386 26,735,369
19. Unit Service Facter 96.9 96.9 71.4
20. Unit Availability Factor 96.9 96.9 71.4
21. Unit Capacity Factor (Using MDC Net) 93.4 95.2 66.9
22. Unit Capacity Factor (Using DER Net) 91.1 91.1 65.9
23. Unit Ferced Outage Rate 3.1 3.1 14.6
24. Shutd: ens Scheduled Over Nest e Months (Type, Date, and Duration of Each):

....B.q tat lin... May..U....l9.8.6... 10..v.e.ebt...................................... _.......................

25. If $5ut Doun At End Of Fe; ort Period. Estinated Date of Startup:,,,,,,,,, _,,,,,,,,,,,,,................,_,,_......

26.UnitsinTestStatus(Prio: to Coseercial Operation):

Forecast Achieved I

IMIT!ALCRITICAL!if l

n m At Eu C m C m CtenuCat m m m l

l L

AVERA6E MILY Uu!T POWER LEVEL 4

DOCKET NO.

50-370 Uuli McGuire 2 MTE February 15,1988 CORPLETED BY

3. A. Reavis TELEPHONE 704-373 7547 MONTH JANUARY,1988 NY AVER 46E DAILY POWER LEVEL MY AVERAGE DAILY POWER LEVEL (MWL-Het)

(MWE-tet) 1 1151 17 1147 2

1151 11 1147 I

3 1151 19 1152 1

4 1151 20

!!S7 5

!!53 21 1155 1

6

!!53 22 1154 7

!!53 23 1154 I

1!53 24

!!50 9

1154 25 1154 10 1154 26

!!54 I1 1153 27 1157 12 182 28 1153 13 435 29 1153 14 462 30 1156 15 1101 31 1153 16 1147

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

_59-329___________

UNIT NAME _MCGUIRE_2________

DATE _Q2/15/@@_________

REPORT MONTH _____ January _19@@_

COMPLETED BY _Jz_A._REAVIS_____

TELEPHONE _12941-323-2562___

p (1)

(2)

(3)

(4)

(5)

R MET-E HDD T

A OF LICENSE N

Y S

SHUT EVENT SYS-CAUSE AND CORRECTIVE O

P DURATION O

DOWN REPORT TEM COMPONENT ACTION TO DATE E

HOURS N

R/X NO.

CODE CODE PREVENT RECURRENCE 1

BB-1-12 F

21.78 A

1 HH VALVEX FAILURE OF AIR FILTER ON

'C' S/G FEED REG. VALVE 1p 88-1-13 F

B HH XXXXXX HOLD FOR SECONDARY CHEMISTRY 2P 88-I-13 F

A HH VALVEX REPAIR S/G

  • C' FEEDWATER CONTAINMENT ISOLATION VALVE 3P 88-1-13 S

B 1E INSTRU HOLD FOR NUCLEAR INSTRUMENTATION CALIBRATION e

4p 88-1-14 F

A HA XXXXXX REPAIR LEAK ON ELECTRO-HYDRAULIC SYSTEM 2

88-1-14 F

1.03 A

1 HA XXXXXX REPAIR LEAK ON ELECTRO-HYDRAULIC SYSTEM 5p 88-1-14 S

B IE INSTRU HOLD FOR NUCLEAR INSTRUMENTION' CALIBRATION (1)

(2)

(3)

(4)

F Forced Reason:

Method:

Exhibit G-Instructions S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or test 2-Manual Scram

' Entry Sheets For Licensa C-Refueling 3-Automatic Scram Event Report (LER)

D-Regulatory Restriction 4-Other (Explain)

File (NUREG-Ol61)

E-Operator Training & License Examination F-Administrative (5)

G-Operator Error (Explain)

Exhibit I - Same Source H-Other (Explain)

.,_. _ ~. _...

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.._SQ-379___________

UNIT NAME

_MCGUIRE_2________

DATE _Q2/15/08_________

REPORT NONTH _____ January _19@@_

COMPLETED BY _J._A._REAVIS_____

b?Sbb~ ?OE? bZ---

Psge 2 of 2 (1)

(2)

(3)

(4)

(5)

R MET-E HOD T

A OF LICENSE N

Y S

SHUT EVENT SYS-CAUSE AND CORRECTIVE O

P DURATION O

DOWN REPORT TEM COMPONENT ACTION TO DATE E

HOURS N

R/X NO.

CODE CODE PREVENT RECURRENCE B

IE INSTRU HOLD FOR NUCLEAR INSTRUMENTATION 6p 88-1-15 S

CALIBRATION I

I I

I (1)

(2)

(3)

(4)

F Forced Reason:

Methoo:

Exhibit G-Instructions i

S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or test 2-Manual Scram Entry Sheets For License (

C-Refueling 3-Automatic Scram Event Report (LER) i D-Regulatory Restriction 4-Other (Explain)

File (NUREG-Ol61)

E-Operator Training & License Examination F-Administrative (5)

G-Operatnr Error (Explain)

Exhibit I - Same Source H-Other (Explain) 3

,... _. -. _ _. ~,.. _.. -

Av 7

DOCKET N0s.

50-370 UNIT:

McGuire 2 DATs:

02/15/88 J

d d

NARRATIVE

SUMMARY

i Month: Jaruary, 1988 McGuire Unit 2 began the month of January operating at 100% full power. On 01/12 at 0425, the unit was removed from service due to low steam generator level caused by an air filter failure on the "C" Steam Generator Feedwater Regulator valve. The unit was returned to service at 0211 on 01/13, and held power at 21% for Secondary Chemistry, at 23% to add hydraulic fluid to the "C" Feedwater Containmant Isolation Valve, and at 50% for nuclear instrumentation i

calibration. The unit reached 90% power at 0010 on 01/14, and shortly 4

thereafter began to shutdown due to a leak on the Electro-Hydraulic Turbine l

Control System. The unit was removed from service at 1051 on 01/14 and. returned 4

to service at 1153 the same day. Following two power holds for nuclear i

inst rumentation calibration, the unit returned to 100% power at 0824 on 01/15, where it operated for the remainder of the month.

I t

i e

m -.

-s l

71

[

1

)

MONTHLY REFUELING INFORMATION REQUEST i

1 d

i 1.

Facility name:.McGuire, Unit 2 1

2.

Scheduled next refueling shutdown:

May, 198g Ju'y, 1988 l

3.

Scheduled restart following refueling:

i 1

4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment? Yes

[

j If yes, what will these be?

Technical Specification Revision If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions? N/A i

5.

Scheduled date(s) for submitting proposed licensing action and supporting l

information: N/A i

6.

Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in i

design or new operating procedures).

{

t 7.

Number of fuel assemblies (a) in the core:

193 (b) in the spent fuel pool: 436 8.

Present licensed fuel pool capacity:

1463 i

Size of requested or planned increase:

I 9.

Projected date of last refueling which can be accommodated by present licensed capacity: August, 2010 i

i l

l t

)

l DUKE POWER COMPANY DATE: February 15, 1988

)

Name of

Contact:

J A. Reavis Phone:

704-373-7567 f

l

't McGUIRE NUCLEAR STATION MONTHLY OPERATING STATUS REPORT i

1.

Personnel Exposure f

For the month of December, no individuals exceeded 10 percent of their allowable annual radiation dose limit.

2.

The total station liquid release for December has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.

The total station gaseous release for December has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this limit.

i I

i

.i 6

f i

l 4

i I

l l

i l

f

F 4

_p Duxe Powna GOMPANY

' P.O. sox 33189 CHARLOTTE. N.c. 28948 HALB.Tt*CKER tuum

,], _,

(704) 3Y3 4eas February 15, 1988 U. 3. Nuclear Regulatory Comission Attention: Document Control Desk Washington, D. C.

20555 Re: McGuire Nuclear Station Docket No. 50-369 and 50-370

Dear Sir:

Please find attached information concerning the performance and operating status of the McGuire Nuclear Station for the month of January, 1988.

Very truly yours, l

x$.1 A e s Hal B. Tucker JAR /1392/sbn Attachment i

xc:

Dr. J. Nelson Grace American Nuclear Insurers Regional Administrator / Region II c/o Dottie Sherman, ANI Library U. S. Nuclear Regulatory Comission The Exchange, Suite 245 101 Marietta Street, NW, Suite 2900 270 Farmington Avenue Atlanta, Georgia 30323 Farmington, CT 06032 Mr. Phil Ross INPO Records Center U. S. Nuclear Regulatory Commission Suite 1500 MNBB-5715 1100 circle 75 Parkway Washington, D. C.

20555 Atlanta, Georgia 30323 Mr. Darl Hood, Project Manager

'tr. Richard G. Oehl, NE-44 office of Nuclear Reactor Regulation U. S. Department of Energy U. S. Nuclear Regulatory Comission 19901 Germantown Road Washington, D. C.

20555 Germantown, Maryland 20874 Mr. Robert G. Rogers Mr. W. T. Orders Nuclear Assurance Corporation NRC Resident Inspector 6251 Crooked Creek Road McGuire Nuclear Station Norcross, Georgia 30092

/