ML20149H541

From kanterella
Jump to navigation Jump to search

Affirms That Approach Described in Util Re Methodology for Seismic Qualification of Control Room Panels Consistent W/Nrc Intent & Acceptable
ML20149H541
Person / Time
Site: Crane 
Issue date: 02/10/1988
From: Hernan R
Office of Nuclear Reactor Regulation
To: Hukill H
GENERAL PUBLIC UTILITIES CORP.
References
RTR-REGGD-01.097, RTR-REGGD-1.097 GL-87-02, GL-87-2, TAC-51361, NUDOCS 8802190315
Download: ML20149H541 (2)


Text

_.

Docket No. 50-289

-Mr. Henry D. Hukill, Vice President and Director - TMI-I GPU Nuclear Corporation Post Office Box 420 Middletown, Pennsylvania 17057

Dear Mr. liukill:

SUBJECT:

R.G. 1.97 AND GL 87-02.NETHOLOGY (TAC NO._51361)

The purpose of this letter is to affirm that your approach described in your letter f 5711-87-2179 dated October 8, 1987 is consistent with the staff's understanding and is acceptable to the staff.

On October 8,1987 you sent a brief clarification letter to the NRC describing your interpretation of the staff's SER and further clarifying details of your trethodology for seismic qualification of control room panels at TMI-1. The understanding you expressed in ycur letter is consistent with the staff's intent and is acceptable.

Sincerely,

' M $1SEB W Renald W. Hernan, Senior Project Manager Project Directorate I-4 Division of Reactor Projects I/II Office of Nuclear Peactor Regulation cc: See next page DISTRIBUTION mDecket#DiFr R. Hernon NRC & Local PDRs OGC i

PDfI-4 Pdg.

E. Jordan S. Varga J. Partlow

8. Boger ACRS (10)

S. Norris Grey ile i

LA:JDI_-4 /

PM:PDI-4

%- DEST:W 4

$No' YI s "

RHernan.

LMa JS 02/7/88 02/t//88 02/

8' 02/g/88 i

i P

)

Mr. Henry D. Hukill Three Mile Island Nuclear Station, GPU Nuclear Corporation Unit No. 1 cc:

G. Broughton Pichard Conte O&M Director, THI-1 Senior Resident Inspector (TMI-1)

GPU huclear Corporation U.S.N.R.C.

Post Office Box 400 Post Office Box 311 Middletown, Pennsylvania 17057 Middletown, Pennsylvania 17057 Richard J. McGeey Manager, PWR Licensing Regional Administrator, Region I GPU Nuclear Corporation U.S. Nuclear Regulatory Commission 100 Interpace Parkway 631 Park Avenue Parsippany, New Jersey 70754 King of Prussia, Pennsylvania 19406 C. W. Smyth Robert B. Borsum THI-1 Licensing Manager Babcock & Wilcox GPU Nuclear Corporation Nuclear Power Generation Civisico Post Office Box 480 Suite 525 Middletown, Pennsylvania 17057 1700 Rockville Pike Rockville, Maryland 20252

-t.

Ernest L. Blake, Jr., Esq.

Governor's Office of State Planning

$C-Shaw, Pittran, Potts & Trowtridge and Development 2300 N Street, N.W.

ATTN: Coordinator, Pennsylvania Washington, D.C.

20037 State Clearinghouse Post Office Box 1323 Harrisburg, Pennsylvania 17120 Larry Hochendener Thenas M. Gerusky, Director Dauphin County Commissicr.er Bureau cf Radiatior. Protection Dauphin County Courthouse Per.nsylvania Department of Front and Market Streets Environrental Resources Harrisburg, Pennsylvania 17120 Post Office Bcx 2063 Parrisburg, Pennsylvania 17120 David D. Maxwell, Chairman Docketing and Service Section Board of Supervisors Office of the Secretary Londonderry Township U.S. Nuclear Regulatory Ccomission RFD!1 - Geyers Church Road Vashington, D.C.

20555 Middletown, Pennsylvaria 17057 l

i 1

1