August 4, 1994
[
Docket No. 50-254 Mr. D. L. Farrar, Manager Nuclear Regulatory Services Commonwealth Edison Company gg m E Tm COPY Executive Towers West III, Suite 500 1400 OPUS Place Downers Grove, Illinois 60515
Dear Mr. Farrar:
SUBJECT:
CORE SPRAY HEADER FLAW EVALUATION AT QUAD CITIES, UNIT 1 (TAC NO. M89707)
We have reviewed Commonwealth Edison Company's (Comed) submittals dated June 17 and July 14, 1994, regarding an evaluation of a crack, found during the current refueling outage, on the "B" cora spray header weld at Quad Cities, Unit 1.
Based on our review we have concluded that Quad Cities, Unit 1, can be safely operated during the next .el cycle (Cycle 14) with the existing crack in the "B" core spray header welo
'le understand that Comed will repair the subject weld by installing a mechanical clamp during the next refueling outage. We also understand that Comed is investigating the option of remote installation of the clamp in order to minimize personnel exposure.
The staff's safety evaluation is enclosed.
Sincerely, Original signed by:
Chandu P. Patel, Project Manager Project Directorate III-2 9400100195 940804 Division of Reactor Projects III/IV PDR ADOCK 05000254 Office of Nuclear Reactor Regulation P
Enclosure:
Safety Evaluation cc w/ enclosure:
See next page l
DISTRIBUTION:
Docket File NRC & Local PDRs E. Adensam PDIll-2 r/f J. Roe J. Zwolinski R. Capri C. Moore C. Patel OGC ACRS (10)
B. Clayton RIII LA:PDIII-2 k h h PM:PDIII-2,.,f7 D:PDIII-2
\\( m wu C. Moore V
C. Patel:lm R. Capra "
$/k/94 7 / 4 /94 9 / 4 /94 hkS)0 kS)NO (IY[DN0 L
w t \\
i l
Mr. D. L. Farrar Quad Cities Nuclear Power Station l
a Commonwealth Edison Company Unit No. I cc:
i Mr. Stephen E. Shelton 1
Vice President Iowa-Illinois Gas and j
Electric Company P. O. Box 4350 Davenport, Iowa 52808 j
Michael I. Miller, Esquire Sidley and Austin One First National Plaza l
Chicago, Illinois 60690 Mr. Guy Campbell Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, Illinois 61242 Quad Cities Resident Inspectors Office U. S. Nuclear Regulatory Commission 22712 206th Avenue North Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.