Forwards Info on Action Taken Re NRC Compliance Bulletin 87-002, Fastener Testing to Determine Conformance W/Applicable Matl Specs. Internal Control Procedures for Fasteners Along W/Results of Independent Testing Also Encl
ML20149E157
Person / Time
Site: Summer 
Issue date: 01/12/1988
From: Nauman D
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-87-002, IEB-87-2, NUDOCS 8802100356
Download: ML20149E157 (78)


Text

--

th Ca Electdc & Gas Company Dan A Namn Columtxa. SC 29218 Nuclear Or4 rations (803) 748-3513 SCE&G January 12,1988 Dr. J. Nelson Grace Regional Administrator U.S. Nuclear Regulatory Commission Suite 2900 101 Afarietta Street, NW Atlanta, Georgia 30323

SUBJECT:

Virgil C. Summer Nuclear Station U Docket No. 50/395 Operatin ? icense No. NPF-12 L

o NRC Bulletin No. 87-02 co

{

Dear Dr. Grace,

On November 13, 1987, South Carolina Electric & Gas Company received NRC Compliance Bulletin No. 87-02, "Fastener testing to determine conformance with apphcable material specifications." As requested, mformation is provided concerning our receipt inspection and our internal control procedures for fasteners along with results of the independent testing of our fasteners. The enclosures to this letter contain the information regarding the action that was taken in accordance with the compliance bulletin.

The information contained in this letter and its enclosures are true and correct to the best of my knowledge,information and belief.

J Ifyou have any questions, please advise.

\\ erytrul rs, 8802100356 080112 1

PDR ADOCK 05000395 G

PDR

_pp LW%

.A,Nauman JSB/ DAN:bjh Enclosures pc:

O. W. Dixon, Jr./r. C. Nichols, Jr.

C. L. Ligon (NSRC)

E. C. Roberts R. AI. Campbell,Jr.

O. S. Bradham K. E. Nodland D. R. Afoore J. C. Snelson W. A. Williams, Jr.

G. O. Percival Document Control Desk R. L. Prevatte Grou W. R.p 31anagers J. B. Knotts, Jr.

Baehr INPO Records Center W. R. IIiggins Afarsh & AIcLennan R. B. Clary ANI Library G. G. Sou1t RTS C. A. Price NPCF Surveillance Systems File T. L. AIntlosz 1

l\\

.7///

L

Enclosure I to NRC Bulletin 87-02 January 12,1988 Page l of 3 4

ENCLOSUREI REQUEST 1:

Describe a) the characteristics currently examined during receipt inspection of fasteners (i.e., head markings for grade and manufacturer symbols, review of certified material test report or certificate of conformance), and b) internal controls utilized during storage and issuance from stock to assure the appropriate use of fasteners.

Response

Safety related fasteners may be procured from an audited and approved supplier a.

orfrom a commercial supplier. The level ofreceipt inspection depends upon the qualification of the vendor.

If the fasteners are procured from an audited and approved supplier who accepts 10CFR21 responsibility, then the receipt inspection consists of the following:

review of the purchase order requirements a.

b.

inspection of the shippingpackage verification that identification and markings are in accordance with the c.

procurement documents; i.e., tagging and labeling requirements d.

inspection for damage and deformation, cleanliness review and verification that purchase order refers to items received.

e.

f.

review and approval ofitem certification (certified material test reports, certificates of conformance, mechanical test reports, etc.)!

Safety-related fasteners procured from a commercial supplier not accepting 10CPR21 responsibility require a more extensive receipt inspection. This method ofprocurement is generally used when ordering fasteners with diameters less than 1/4" since these items generally are not supplied as safety related. When the purchase requisition for fasteners is developed, the specifying engineer determines additional receipt inspection requirements. The additional requirements are developed through the use of machinist and metals handbooks, site mechanical maintenanceprocedures which provide torquing requirements, manufacturers' catalogs and evaluation ofpotential end-use design basis criteria. Additional requirements generally include material analysis and functional testing.

Receipt inspection of nonsafety related fasteners consists ofitems a through e above item fdoes not apply since non safety items would not require certification. Ifcertification is provided, the documents are placed in the purchase order file and maintained as a record and retrievable in the event an on-site certification is required at a future date.2 IQuality and Procurement Services Procedure No. 701, Revision ! 3:03:87.

2 Quality and Procurement Services Procedure No. 401, Revision !,6112:87.

Enclosure I to NRC Bulletin 87-02 January 12,1988 Page 2 of 3 i

On site certifications are utilized to upgrade existing non safety warehouse items to safety related. Upgrade requirements are developed in the same manner as receipt inspection requirements for safety-related fasteners procured from commercial suppliers. For fasteners with diameters greater than 1H", the corresponding standard is researched to develop appropriate testing requirements and acceptance criteria. The original documentation supplied with the item may also be used to obtain information; however, all information in these reports must be physically verified before acceptance.

All documents affecting orpertaining to the use ofsafety related items are reviewed by Quality Engtneering. These documents include purchase requisitions, on site certifications, nonconformance notices, etc. The Quality Engineer is responsible for determining that applicable regulatory reouirements, design bases, AShfE code requirements, industry standard (ASThi, ANSI, etc.)

requirements, and other requirements necessary to assure quality are incorporated into the procurement and testing requirements. In addition, the Quality Engineer assesses the vendor's qualifications and specifies additional requirements to assure the required level ofquality.s This independent review provides additional assurance that items will be procured and/or tested commensurate with the degree of verification required for its intended use, b.

All safety-related fasteners received at V. C. Summer Station are identified by an item Identification Record (IIR). The llR is affixed to the item or ifphysical tagging is not feasible, a serial number or other positive identification is recorded on the llR tag and filed in the appropriate purchase order folder. Upon successful completion of the applicable receipt inspection requirements, the items are placed in safety related stock.

Access controls for each storage area are established consistent with the need for access by specific individuals. Safety-related items are physically separated from non-safety items.4 At V. C. Su m mer Station, both safety and non-safety fasteners are stored consistent with ANSIN45.2.2 Level B requirements.

Fasteners are issued from the warehouse via an approved stores requisition.

Requisitions for safety related fasteners contain the following information as appropriate:

a.

Work document number to which the fasteners will be used;i.e.,

hiaintenance Work Request (htWR), hfodification Request Form (hfRF),

Surveillnnce Test Task Sheet (STTS), etc.

b.

Equipment number to which fasteners are being issued.

c.

Accounting information d.

Part number, description and quantity issued.

The original requisition for safety related issues is sent topermanent records storage. A copy is given to the recipient. hiaintenance Work Requests, Shop Work Orders, Phi and Surveillance Task Sheets are also authorities for the 3 Quality and Procurement Services Procedure h. 501. Ilevision 0, ill186.

4 Quality and Procurement Services Procedure No..tal, ltevision I. 6ll2:S7.

Enclosure I to NRC Bulletin 87-02 January 12,1988 Page 3 of 3 l

issuance ofsafety-related materials; hau ever. a stores requisition con!aining the above information (items a through d) is still required Once the items have been issued from stock, their use is controlled through the stores requisition to which the part was issued. All maintenance on station components, systems or structures is performed using an MWR, STTS, etc.

Station Quality Control (QC) is notified prior to the start of any maintenance activity.6 QC review is required when maintenance and modification activities affect safety related structures, systems and components. As defined by the appropriate work documant, fasteners used in performance ofsafety related work activities are verified by QC to be adequate for safety related use. The QC inspectorperforms this verification by reviewing the stores requisition, on-site certification. or other pertinent documentation stating the item's acceptance for safety related use. The fasteners may be used to complete the maintenance activity only after QC verification and approval.7 The stores requisition and maintenancelmodification documents are the key internal controls utilized to assure the appropriate use offasteners. Station Quality Control serves as the final assurance that all fasteners used in safety-related equipment meet the required level ofquality for their intended end use.

3 Station Administrative Procedure No.136,Itreision 0. 7/2%SG 6Sta tion Adminsstrative Procedurr No. 300. Itevision 3,10'!rM 7 Quality and Procurement Services Procedure No. 601, Revision 3, !1 #87.

Enclosure II to NRC Bulletin 87 02 January 12,1988 Page l of1 l

ENCLOSURE II REQUEST 2:

Select a minimum sample of ten (10)non safety related fasteners (studs, bolts, andiur cap screws), and ten (10) safety related fasteners (studs, bolts, and/or cap screws) from current,in use, stock. The sample is to be obtained by the licensee with the participation of an NRC inspector. Fasteners procured to meet the following chemical and mechanical properties are ofinterest: A 193 grades B7, H8, and B16; SAE J429 grades 5 and 8; A 449; A 325 Types 1,2 or 3; A 354 grades HH, HC, HD; A 490; A 320 LTAI; A 307; A 563;or equivalent.

Response

Safety-related fasteners to be tested were selected using the grades listed in the Bulletin. Fasteners most widely stocked were selected for multiple samples in order to complete the safety related fastenergroup since certain grades offasteners were not carried as stock items. Non safety fasteners were selected using the same criteria as for safety related fasteners. All fastener sample selections were obtained with the concurrence of the NRC Senior Resident inspector.

Fasteners procured to meet the following specifications were selected: A 193 grades B7 and B8; A-449; A-325 type 2: A-354 grade BD; A-490; A 307, l

l l

Enclosure III to NRC Bulletin 87-02 January 12,1988 Page l of1 ENCI.OSUltE 111 ItEQUEST 3:

For the selected sample of fasteners in item 2, Include a sample of typical nuts l

that would be used with each fastener (one for one). In particular, nuts aurchased to the chemical and mechanical specifications of A 194 are of nterest.

Response

Nuts were selected as appropriate with bolts chosen for testing. Seven types of nuts were selected for testing with a total ofeleven in the sample. Several samples were chosen that had been procured to meet the specifications ofA-194. All nut sample selections were obtained with the concurrence of the NRC Senior Resident inspector.

Nuts procured to meet the following specifications were selected: A 194; A 563.

4

Enclosure IV to NRC Bulletin 87 02 January 12,1988 Page l of1 ENCLOSU RE IV REQUEST 4:

Chemical testing shall be performed on all samples. Mechanical testing shall be performed on each safety related fastener. Hardness testing shall be performed on each nut and non safety related fastener. All testing shall be performed by a laboratory which the licensee has qualified for this type of testing and appears on the licensee's approved vendor list. Testing performed shall be done in accordance with the requirements of the fastener's specification, grade, and class, and the test shall evaluate the ultimate tensile strength, hardness and chemical properties as required by the fastener's sp'ecification, grade, and class. Each sample shall be tagged with the sample s ID number.

Response

The Licensee procured the services ofLaw Engineering Industrial Services as the approved vendor to perform independent testing on the fastener samples. All testing was performed under purchase order number Q478707 in accordance with the requirements ofBulletin 87 02.

Since many non safety related fasteners are procured by description only i e. ASTM standards are not specified in the purchase order. the ASTM standard mcst closely relating to the item was utilized as the testing standard, if the standard could bc determined from the head marking, then that standard was used for testing.

Enclosure V to NRC Bulletin 87 02 January 12,1988 Page 1 of1 ENCLOSUllE V REQUEST 5:

The results of all tests, together with supporting information, are to be re aorted to the NRC utilizing the fcrmat shown in Attachments I and II of th s bulletin. Include the names and addresses of suppliers and manufacturers of safety related fasteners and, to the extent possible, of non-safety related fasteners. For any fastener found out of specification, provide an evaluation of the safety significance including consideration of the most limiting application.

Response

The in(crmation requested has been provided as attachments to this enclosure.

A ttachment Icontains the individual fastener data sheet for each sample slected in accordance with the Attachment Iprovided in Bulletin 87-02. The results of the testing have been provided in A ttachment II which contcins the individual sample test results sheets from Law Engineering Industrial Services. A ttachment II data sheets have been submitted in lieu of the Attachment 11 format given in Bulletin 87-02. An engineering evaluation was performed on the eight fasteners that did not meet the acceptance criteria forportions of the testing. The engineering evaluation has been included as Attachment 111.

The data and results sheetsprovided in Attachment Iand Attachment 11are ordered according to sample tag identification number and item letter. Sheets which contain the same item number indicate that a non safety fastener and nut were selected together. When an item letter is followed by a number. it indicates that more than one specimen was tested in that sample.

,,,-au,,

-e

.u

-a-


wa-

--aa

--_a

_a 4,,

m___

AT ACH VIENT OF ENCLOSURE V

Attachmant I Fastenor Testing Data Shoot

' Sample ID# VCS-81557 Items A Fastener

Description:

5/8" Nut Purchase Orders #SN10218SR Description of Sample Stock Location: Safety Related Bins -

Warehouse C Material Specification as Documented by Licensee Records:

ASTM - A325 GRADE A (Fasteners ordered to ASTM A325 Grade A were shipped with the associated nut which is an ASTM - A563 Grade A).

Head Marking (Specification and Manufacturer):

()

None

    • Class / Procurement Level: Nuclear Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Various - Previous applications include steam dump valve IFV-2016-MB, Main H.P. Turbine, and "C Pump B.

Vendor:

Applied Eng. Co. Inc.

P.O. Box 1327 Orangeburg, S.C. 29115 (803-534-2424)

Supplier: N/A Manufacturer:

Commercial Fasteners Corp.

241 Lafayette St.

New York, NY 10012 QA Requirements Imposed on Vendor: 10CFR50 APP. B Licenice Representative Mark G. Curtiss

}

Date /

Signature.

f_ r,mu The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your cir af! cation ayst..m.

Attachmsnt:I Fastener Testing Date lheet l

  • Sample ID# VCS-81568 Item: B Fastener

Description:

1/2" Nut l

4 l

Purchase Ordsr

  1. SN10218SR l

Description of Sample Stock Location: Safety Related Bins -

Warehouse C 4

Material Specification as Documented by Licensee Records:

ASTM - A307 GRADE A (Fasteners ordered to ASTM A307 Grade A i

specifications were shipped with the associated nut-which is an ASTM-A563 Grade A.)

a Head Marking (Specification and Manufacturer): None

    • Class / Procurement Level: Nuclear Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Various - Previous applications include Circulating Water Pump C and the Reactor Building Instrument Air Supply Isolation Valve.

Vendor:

Applied Engineering Co. Inc.

P.O. Box 1327 Orangeburg, S.C. 29115 (803-534-2424)

Suppliers I

r Manufacturer:

QA Requirements Imposed on Vendor: 10CFR50 APP. B Licensee Representative:

Mark G. Curtiss Signature h/

m Date

/

6 i

The sample ID# shall have a prefix that contains the licensee j

facility initials.

e

    • If applicable, please provide an explanation for your I

classification system.

l

      • Due to the age, length of time the purchase remained open and the way the purchase order was filed, this information would require an extensive and costly search.

[

_=

Attachment I

, Fastener Testing Data Sheet

' Sample ID# VCS-81556 Item: C i

e Fastener

Description:

1" Nut Purchase Order: # A392838 1

Description of Sample Stock Location: Safety Related Bins -

Warehouse C l

Material Specification as Documented by Licensee Records:

ASTM - A194 GRADE 2H i

Head Marking (Specification and Manufacturer):

1 H

i l

    • Class / Procurement Level: Nuclear Safety Related i

General Plant Application (e.g., Pressure Boundary, Structural)

Various - Procured for the Reactor Building Equipment Hatch.

Vendor:

Energy Steel & Supply Co.

[

5941-18 Providence Dr.

Charlotte, N.C. 28226 i

I Supplier N/A Manufacturer:

Hamanaka Nut Mfg. Co. LTD Himfji, Japan l

QA Requirements Imposed on Vendor: 10CFR50 APP. B 1

Licensee Representative: Mark G. Curtiss Signature 7V Date

/

8 The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

. =.

Attachment I Fastenor Testing Data Sheet l

' Sample ID# VCS-81540 Item: D l

Fastener

Description:

1" Nut Purchase Order: #Q257804 1

Description of Sample Stock Location: Safety Related Bins -

Warehouse C Material Specification as Documented by Licensee Records:

ASTM-A307 GRADE A (fasteners ordered to ASTM-A325 Grade A were shipped with the associated nut which is an ASTM - A563 Grade A) l Head Marking (Specification and Manufacturer):

B Bethlehem Steel t

i j

    • Class / Procurement Level Nuclear Safety Related j

l General Plant Application (e.g., Pressure Boundary, Structural) i Various i

Vendor:

Capitol Pipe 4 Steel Products Co.

  1. 5 Woodlawn Gran, Suite 136 Charlotte, N.C. 28210 (Out of Business)

Supplier:

N/A l

Manufacturer:

Bethlehem Steel 701 East 3rd St.

Bethlehem, Pennsylvania 18016 i

l QA Requirements Imposed on Vendor: 10CFR50 APP. B i

i I

Licensee Representative Mark G. Curtiss 7

Signature 74 Date

/

The sample ID# shall have a prefix that contains the licensee facility initials.

1

If applicable, please provide an explanation for your j

classification system.

,,_-.,,-nn- - +, -. -..

,,,,,,,-,w-,

,,.-...--------,,-.-,-,--wn-

Attachmont I Fastener Testing Data Sheet

  • Sample.ID# VCS-81543 Item E r

Fastener

Description:

5/8" Nut Purchase Orders # Q437287 Description of Sample Stock Location: Safety Related Bins -

Warehouse C Material Specification as Documented by Licensee Records:

ASTM A563 GRADE A Head Marking (Specification and Manufacturer):

bg Bethlehem Steel I

i

    • Class / Procurement Level: Nuclear Safety Related i

i General Plant Application (e.g., Pressure Boundary, Structural)

Various P

Vendor:

Hub, Inc.

2146 Flintstone Dr.

Tucker, GA 30084 Supplier:

N/A i

Manufacturer Bethlehem Steel 701 East 3rd St.

Bethlehem, Pennsylvania 18016 QA Requirements Imposed on Vendor: 10CFR50 APP. B Licensee Representative: Mark G. Curtiss Signature 7M Date

/

se

}

/'

t l

The sample ID# shall have a prefix that contains the licensee i

facility initials.

i

    • If applicable, please provide an explanation for your l

classification system.

l

Attachmsnt I Fastener Testing Data Sheet I

l

' Sample ID# VCS-81544 Item: F Fastener

Description:

1/2 Nut Purchase Orders # Q311260 2

l 1

Description of Sample Stock Location: Safety Related Bins -

Warehouse C s

Material Specification as Documented by Licensee Records:

ASTM - A194-2H Head Marking (Specification and Manufacturer):

\\g Bethlehem Steel

    • Class / Procurement Level: Nuclear Safety Related i

l General Plant Application (e.g., Pressure Boundary, Structural)

Various - Previous applications include the Diesel Generator Fuel Oil Day Tank A, Reactor Building Cooling Unit Fan 65A normal motor and the steam packing condenser.

Vendor Power Engineering Products Co.,

Inc.

P.O. Box 382 South Plainfield, N.J. 07080 (Out of Business) d Supplier N/A Manufacturer Bethlehem Steel 1

701 East 3rd St.

Bethlehem, Pennsylvania 18016 i

l QA Requirements Imposed on Vendor: 10CFR50 APP. B l

3 i

Licensee Representative: Mark G. Curtiss Signature 7[ [

Date

//a

/

1 The sample ID# shall have a prefix that contains the licensee 1

facility initials.

j

    • If applicable, please provide an explanation for your l

classification system.

I l

Attachmsnt I Fastener Testing Data Sheet

-

  • Sample ID# VCS-81542 Item's G' l

l Fastener

Description:

9/16" Stainless Steel Nut Purchase Order: # Q311260 Description of Sample Stock Location: Safety Related Bins -

i Warehouse C Material Specification as Documented by Licensee Records:

ASTM - A194 Grade 8 A

Head Marking (Specification and Manufacturer):

JB i

i I

J j

    • Class / Procurement Level: Nuclear Safety Related i

l General Plant Application (e.g., Pressure Boundary, Structural) 1 Various t

Vendor Power Engineering Products Co., Inc.

P.O. Box 382 South Plainfield, N.J. 07080 (Out of Business) r Suppliers Manufacturer:

QA Requirements Imposed on Vendor: 10CFR50 APP. B 4

t 1

Licensee Representative:

Mark G. Curtiss Signature 7t-Date

/

i

/

' /

The sample ID# shall have a preflx that contains the licensee facility initials.

If applicable, please provide an explanation for your

[

classification system.

i

      • Due to the age, length of time the purchase remained open and the way the purchase order was filed, this information would require an extensive and costly search.

l

Attachment I

.l Fastensr Testing Data' Sheet l

1 j

' Sample ID# VCS-81567

-Item: H

.j i

j Fastener

Description:

9/16 Stud-12x6" j

l Purchase Orders # 0311260 I

Description of Sample Stock Location: Safety Related Bins -

l 1

Warehouse C a

t Material Specification as. Documented by Licensee Records:

ASTM - A193-87 i

j Head Marking (Specification and Manufacturer) i B7S

    • Class / Procurement Level: Nuclear Safety Related i

General Plant Application (e.g., Pressure Boundary, Structural)

Various i

l Vendor Power & Engineering Products Co.,

Inc.

i P.O. Box 382 i

j South Plainfield, N.J. 07080 (Out of Business) l l

Supplier:

i Manufacturer:

QA Requirements Imposed on Vendor: 10CFR50 APP. B I

3 i

Licensee Representative:

Mark G. Curtiss Signature 7M Date

/I t

l The sample ID# shall have a prefix that contains the licensee I

j facility initials.

l l

    • If applicable, please provide an explanation for your i

i classification system.

l l

      • Due to the age, length of time the purchase remained open and f

the way the purchase order was filed, this information would l

a require an extensive and costly search.

i t

1 i

.- ~

Attachment I Fastener Testing Data Sheet

' Sample ID#

VCS-81559 Item: I Fastener

Description:

7/8" - 14 x 3" Hex Head Bolt Purchase Orders #Q311260 Description of Sample Stock Location: Safety Related Bins -

Warehouse C Material Specification as Documented by Licensee Records:

A307 Grade B Head Marking (Specification and Manufacturer):

S

    • Class / Procurement Level Nuclear Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor:

Power & Engineering Products Co., Inc.

P.O. Box 382 South Plainfield, N.J. 07080 (Out of Business)

Supplier:

N/A Manufacturer:

Standard Nut & Bolt Company 49 Abbott Street Cumberland, RI 02864 QA Requirements Imposed on Vendor:

10CFR50 APP. B Licensee Representative:

Mark G. Curtiss Signature w

Date

/,

6 The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

Attachment lI Fastener-Testing Data Sheet

' Sample ID# VCS-81562 Item: J t

Fastener

Description:

5/8" - 11 ac 4" Hex Head Bolt i

Purchase Order: 0 Q257979 Description of Sample Stock Location: Safety Related Bins -

Warehouse C P

Material Specification as Documented by Licensee Records:

ASTM - A193 Gr:de B7 c

F Head Marking (Specification and Manufacturer):

B7 T

5

Class / Procurement Level Nuclear Safety Related t

General Plant Application (e.g., Pressure Boundary, Structural)

Various - Previous applications include the Diesel Building Sprinkler System Deluge Valve Inlet Valve.

[

1 r

Vendor:

Atlantic Bolt & Screw Co.

I P.O. Box 164 Cayce, S.C. 29033 Suppliers Manufacturers i

QA Requirements Imposed on Vendor: 10CFR50 APP. B

[

l Licensee Representative Mark G. Curtiss

,/M Signature 21 /

Date m

' The sample ID# shall have a prefix that contains the licensee facility initials.

If applicable, please provide an explanation for your classification system.

"'Due to the age, length of time the purchase remained open and the way the purnhase order was filed, this information would require an extensive and costly search.

Attachment I Fastener Testing Data Sheet

  1. Sample ID#- VCS-81558 Item: K j

t Fastener

Description:

7/8" - 9 x 2-3/4" Hex Head Bolt Purchase Order: # 0292985 Description of Sample Stock Location: Safety Related Bins Warehouse C t

Material Specification as Documented by Licensee Records:

ASTM - A325

~

Head Marking (Specification and Manufacturer):

III A325 Bethlehem Steel

    • Class / Procurement Level Nuclear Safety Related

~

General Plant Application (e.g., Pressure Boundary, Structural) e Various Vendor:

Southern Bolt & Fastener Corp.

i P.O. Box 7196 j

Shreveport, Louisiana 71107 2

I Supplier:

N/A Manufacturer:

Bethlehem Steel 701 East 3rd St.

i Bethlehem, Pennsylvania 18016 QA Requirements Imposed on Vendor: 10CFR50 APP. B l

I i

Licensee Representative Mark G. Curtiss Signature 7// /

Date u-

/,//

/

l The sample ID# shall have a prefix that contains the licensee j.

facility initials.

If applicable, please provide an explanation for your classification system.

Attachmont I Fastener Testing Data Shoot t

' Sample ID# VCS-81565 Item: L i

Fastener

Description:

1/2" - 13 x 2-1/2" Hex Head Solt Purchase Order: #Q260946 Description of Sample Stock Location: Safety Related. Bins -

Warehouse C Material Specification as Documented by Licensee Records:

ASTM - A325 Head Marking (Specification and Manufacturer):

T B l

/

\\

\\

Texas Bolt A325 t

    • Class / Procurement Level: Nuclear Safety Related i

General Plant Application (e.g., Pressure Boundary, Structural)

Various - Previous applications include the Turbine Generator j

Bearings Sprinkler System Deluge Inlet Valve.

I Vendor:

Texas Bolt Company P.O. Box 1211 6

j Houston, Texas 77001 1

)

Supplier N/A l

Manufacturer:

Same as Vendor QA Requirements Imposed on Vendor: 10CFR50 APP. B Licensee Representative Mark G. Curtiss 1

Signature 7v Date /I m

t-t J

The sample ID# shall have a prefix that contains the licensee j

facility initials.

l

" If applicable, please provide an explanation for your j

classification system.

I i

e

??^

Attachmsnt I H-l

-Fastener Testing Data Sheet l

' Sample ID# _ VCS-81564 Item: M 4

I i

Fastener

Description:

1/2" - 13 x 2-1/2" Hex Head Bolt i

i -

i Purchase Orders # SN10218 SR Description of Sample Stock Location: Safety Related Bins -

l Warehouse C L

Material Specification i.s Documented by Licensee Records:

ASTM - A307 Grade A Head Marking (Specification and Manufacturer):

(J3 Bethlehem Steel i

i

    • Class / Procurement Level Nuclear Safety Related 1

General Plant Application (e.g., Pressure Boundary, Structural)

Various 4

Vendor:

Applied Engineering Co. Inc.

P. O. Box 1327 Orangeburg, S. C.

29115 (803-534-2424)

Supplier N/A Manufacturer:

Bethlenem Steel 701 East 3rd St.

Bethlehem, Pennsylvania 18016 1

QA Requirements Imposed on Vendor: 10CFR50 APP. B Licensee Representative Mark G. Curtiss Signature M Date e,/[

q

  • The sample ID# shall have a prefix that contains the licensee l

facility initials.

    • If applicable, please provide an explanation for your classification system.

i l

l

t Attachment I, Fastener Testing Data Shset I

' Sample ID# VCS-81560 Item: N l

l Fastener

Description:

7/8" - 9 x 4-1/2" Hex Head' Bolt j

j i

7 Purchase Orders # 0334040 j

l Description of Sample Stock Location: Safety Related Bins -

Warehouse C 4

l Material Specification as Documented by Licensee Records:

ASTM - A490 l

]

Head Marking (Specification and Manufacturer):

g470 11971 A490 S

f I

    • Class / Procurement Level: Nuclear Safety Related q

General Plant Application (e.g., Pressure Boundary, Structural)

Various - Previous applications include the Diesel Generator Cooler B Fire Service Supply Valve.

l 1

i Vendor:

Southern 1olt & Fastener Corp.

j P.O. Box 7196 i

j Shreveport, Louisiana 71107

)

j Supplier N/A l

}

Manufacturer:

Same as Vendor j

l i

QA Requirements Imposed on Vendor 10CFR50 APP. B 1

l Licensee Representative Mark G. Curtiss Signature 7/

Date

/

/

S

<m i

The sample ID# shall have a prefix that contains the licensee l

facility initials, j

l

    • If applicable, please provide an explanation for your l

classification system.

i

=.

Attachmsnt I

[

Fastoner Testing Data Shaet i

4

' Sample ID# VCS-81555 Item: 0 i

Fastener

Description:

3/4" - 10 x 7" Hex Head Bolt Purchase Orders # Q256236 i

l Description of Sample Stock Location: Safety Related Bins -

l Warehouse C Material Specification as Documented by Licensee' Records:

I ASTM - A193 Grade B7 i

C F

l Head Marking (Specification and Manufacturer):

B7 T

I t

1

    • Class / Procurement Level: Nuclear Safety Related i

General Plant Application (e.g., Pressure Boundary, Structural)

Various - Procured for Spray Ring Hangers.

Vendor:

Atlantic Bolt & Screw Co.

P.O. Box 516 West Columbia, S.C. 29169 Phones 794-6902 Supplier: Southeastern Bolt and Screw Division United States Pipe and Foundary Co.

Manufacturer:

Cardinal Threading A Division of Cardinal American Corp.

5185 Richmond Road Bedford Hts.. Ohio 44146 i

Phone:

216-831-3800 QA Requirements Imposed on Vendor: 10CFR50 APP. B i

Licensee Representative:

Mark G. Curtiso

,,s' Signature 7r// ~

m Date

/

r i

The sample ID# shall have a prefix that contains the licensee facility initials.

" If applicable, please provide an explanation for your j

classification system.

I

l l

Attachment I

[

Fastener Testing Data Sheet i,

j

' Sample ID#

VCS-81563 Item: P 1

i j

Fastener

Description:

1/2" - 13 x 3" Stainless Hex Head Bolt Purchase Orders #Q311260 Description of Sample Stock Location: Safety Related Bins -

Warehouse C i

I Material Specification as Documented by Licensee Records:

A193 Grade B8 Class 1 i

Head Marking (Specification and Manufacturer):

j B8 S

?

l "Class / Procurement Level:

Nuclear Safety Related

}

i General Plant Application (e.g., Pressure Boundary, Structural)

Various - Previous Applications include Intermediate Building sump pumps and auxiliary condenser cleaning pit sump pumps.

Vendor Power & Engineering Products Co., Inc.

[

P.O. Box 382 r

South Plainfield, N.J. 07080 (Out of Business) l t

Supplier N/A l

t Manufacturer:

Standard Nut & Bolt Company 49 Abbott Street Cumberland, RI 02864 l

QA Requirements Imposed on Vendor:

10CFR50 APP. B Licensee Representative Mark G. Curtiss

/ / / [,,s

i

[4 Date

/,

Signature e

l The sample ID# shall have a prefix that contains the licensee facility initials.

l l

If applicable, please provide an explanation for your classification system.

l l

i J

Attachmant I Festense Tosting Data Sheet

' Sample ID# VCS-81561 Item: Q Fastener

Description:

3/4" - 16 x 3" Stainless Steel Hex Head

[

Bolt l

Purchase Orders # Q311260 l

?

t Description of Sample Stock Location: Safety Related Bins -

i Warehouse C j

l l

Material Specifloation as Documented by Licensee Records:

ASTM-A193 Grade B8 Class 1 i

Head Marking (Specification and Manufacturer):

B8 5

l i

Class / Procurement Level:

Nuclear Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Various l

Vendor: Power Engineering Products Co., Inc.

P. O. Box 382 i

South Plainfield, N. J.

07080 (out of business) l Suppliers ***

I

}

Manufacturer QA Requirements Imposed on Vendor: 10CFR50 APP. B I

Licensee Representative:

Mark G. Curtiss Signature M/

N-D&te //-

r

+

The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your J

classification system.

l

.I

      • Due to the age, length of time the purchase order remained

)

open, and the way the purchase order was filed this information would require an extensive and costly search.

j l

i

=

Attachment I i

l l

Fastenar Testing Data Sheet j

j

' Sample ID# VCS-81534 Item R l

j Fastener

Description:

Hex Head Cap Screw, 3/4" - 16 x 4" j

i 4

i Purchase Orders

  1. Unknown 1

4 Description of Sample Stock Location: Non-Safety Bins -

Warehouse C i

i l

i Material' Specification as Documented by Licensee Records:

l Not on file a

t l

Head Marking (Specification and Manufacturer) ASTM A354 GRADE BD i

PARKER KALON I

DIVISION USM i

i g

f CORPORATION i

l COMMERCIAL GRADE (SYMBOL MATCH -

l ONLY) i i

)

    • Class / Procurement Level: Non-Safety I

3 General Plant Application (e.g., Pressure Boundary, Structural)

Various 4

?

Vendor Not on File i

j Supplier Not on File.

l i

l Manufacturer Not on File.

I QA Requirements Imposed on Vendor: None l

l Licensee Representative: Mark G. Curtiss l

I Signature

~7 v

[#

Date /[

6 l

j The sample ID# shall have a prefix that contains the licensee l

facility initials.

}

If applicable, please provide an explanation for your i

j classification system.

l I

4 i

J

a

~,.a n

~c

-a Attechmsnt I t

Fostoner Testing Data Sheet

  • Sample ID# VCS-81547 Item R l

l l:

Fastener

Description:

3/4" Nut j

1 I

)

Purchase Orders

  1. Unknown i

)

i l

Description of Sample Stock -Location: Non-Safety Bins -

Warehouse C l

Material Specification as Documented by Licensee Records:

1' Not on File

+

1 4

Head Marking (Spec.lication and Manufacturer): None i

Assumed A-563 Gradt B i

    • Class / Procurement Level Non-Safety

[

t

.I r

i 4

General Plant Application (e.g., Pressure Boundary, Structural) l l

Various f

l Vendor: Not on File i

{

i l

Supplier Not on File l

i

]

Manufacturer Not on File j

j QA Requirements Imposed on Vendor None 1

t i

l Licensee Representative Mark G. Curtiss

/,/I/

Signature 7 A, J.

Date w,-

t l

The sample ID# shall have a prefix that contains the licensee I

facility initials.

i

    • If applicable, please provide an explanation for your i

classification system.

j

)

d 1

i

)

i i

)

i i

Attachmsnt I I

Fostoner Testing Data Shcet i

]

' Sample ID# VCS-81536 Item: S l

}

Fastener

Description:

Hex Head Bolt, 3/4" - 10 x 6" t

Purchase Orders

  1. Unknown Description of Sample Stock Location:Non-Safety Bins -

l 4

Warehouse C Material Specification as Documented by Licensee Records:

Not on File I

Head Marking (Specification and Manufacturer) ASTM A449 ARMCO STEEL CORP.

i (SYMBOL MATCH A

S ONLY) i

}

Class / Procurement Level: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor: Not on File 1

l Supplier Not on File s

Manufacturer:

Not on File t

QA Requirements Imposed on Vendor: None i

Licensee Representative Mark G. Curtiss Signature -h,

,I Date

/

2

)

The sample ID# shall have a prefix that contains the licensee l

facility initials.

{

t

If applicable, please provide an explanation for your l

1 classification system.

t

Attachment I Fastener Testing Data Sheet

' Sample ID#- VCS-81545 Item S Fastener

Description:

3/4" Nut Purchase Orders

  1. Unknown Description of Sample Stock Location:Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File Head Marking (Specification and Manufacturer): None Assumed ASTM A563 Grade B

    • Class / Procurement Level Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

[

Various

~

Veiidor: Not on File Supplier Not on File i

Manufacturer:

Not on File QA Requirements Imposed on Vendor None i

t Licensee Representative: Mark G. Curtiss l

/,/S/b Signature

~~ 7 M, $

Date r -

/

I The sample ID# shall have a prefix that contains the licensee facility initials.

j

    • If applicable, please provide an explanation for your classification system.

l l

... ~..

Attachmsnt I e

'Fastoner Testing Data Shoot t

l

' Sample ID# VCS-81541 Item T-i Fastener

Description:

Socket Head Capscrew 3/4" x 3" i

Purchaser Orders

  1. Unknown Description of Sample Stock Location:Non-Safety Bins -

Warehouse C l

5 Material Specification as Documented by Licensee Records:

f Not on File Head Marking (Specification and Manufacturer): None Assumed ASTM A574 t

    • Class / Procurement Le'<el: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various l

I Vendor: Not on File I

Supplier Not on File l

i Manufacturer:

Not on File I

i QA Requirements Imposed on Vendor: None i

Licensee Representative: Mark G. Curtiss j

Signature 7/

[

Date

/

The sample ID# shall have a prefix that contains the licensee j

facility initials.

l

If applicable, please provide an explanation for your l

classification system.

f

Attachment I Fastener Testing Data Shoet

  • Sample ID# VCS-81537 Item: U Fastener

Description:

-Capscrew 1" - 14 x 6" Purchase Orders

  1. Unknown Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File Head Marking (Specification and Manufacturer) ASTM A449 ARMCO STEEL CORP.

I (SYMBOt. M ATCH '

A S

ONLY)

/

\\

    • Class / Procurement Level: Non-Safety General Plant Application (e.g.. Pressure Boundary, Structural)

Various Vendor: Not on File Supplier:

Not on File Manufacturer:

Not on File QA Requirements Imposed on Vendor: None Licensee Representative Mark G. Curtiss

,Z/,[

MZ Date

,////

Signature B

~

c The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

Attachment I Fastoner Testing Data Sheet

' Sample ID# VCS-81533 Item: V Fastener

Description:

Cap Screw, 1/2".x 3" (Hex Head)

Purchase Order:

  1. Unknown Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File

'He' a Marking (Specification and Manufacturer) ASTM A354 GRADE BD PARKER KALON I

DIVISION s

USM CORPORATION (SYMBOL MATCH

\\

ONLY)

    • Class / Procurement Level: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor: Not on File Suppliere Not on File Manufacturer:

Not on File QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature

'////.

/

Date /

i The sample ID# shall have a prefix that contains the licensee facility initials.

If applicable, please provide an explanation for your classification system.

Attachmont-I Fastenor Testing Data Sheet

  • Sample ID# VCS-81531 Item: W Fastener

Description:

Stainless Steel Hex Head Cap Screw, 1/2" x 2-1/4" Purchase Order:

  1. Unknown Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File Head Marking (Specification and Manuf acturer) Markin s could not be absolut ly identified -

Assumed Alloy 303 I

assumed standard commercial grade:

    • Class / Procurement Level: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor: Not on File Supplier:

Not on File Manufacturer:

Not on Ff.le QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature 7((

[-,

Date

/

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

Attachment.I j

Fastener Testing. Data Sheet

  • Sample ID# VCS-81538 Item: x Fastener

Description:

Stainless Steel Hex Head Cap Screw 3/4" -

10 x 3" Purchase Order:

  1. Unknown-Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File Head Marking (Specification and Manufacturer) Markingscould not be absolutely identified -

Assumed Alloy 303

' assumed standard N

commercial grade:

    • Class / Procurement Level: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor: Not on File Supplier:

Not on File Manufacturer:

Not on File QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature 'J u,

/,

Date e

The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification systet..

Attachment I Fastoner Testing Data Sheet Item:

Y The letter "Y" was not used; therefore, no Item Y exists.

i i

l l

i a

f 4

Attachmsnt I Fastener Testing Data Sheet

  • Sample ID# VCS-81539 Iter: Z Fastener

Description:

Socket' Steel Socket Head Cap Screw 5/8" -

11 x 3" Purchase Order:

  1. Unknown Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification as Documenbed by Licensee Records:

Not on File Head Marking (Specification and Manufacturer): None Assumed Alloy 303

    • Class / Procurement Level: Non-Safety l

i General Plant Application (e.g., Pressure Boundary, Structural)

Various i

Vendor: Not on File j

Supplier:

Not on File Manufacturer:

Not on File i

l QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature 7V[

Date

/

  • The sample 10# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

Attachment I Fastener Testing Data Sheet

  • Sample ID# VCS-81530 Item: AA Fastener

Description:

Hex Head Capscrew 1/2" x 3-1/2" Purchase Order:

  1. Unknown Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File Head Marking (Specification and Manufacturer) ASTM A449 TYPE 1 MANUFACTURER I

UNDETERMINED M.

V.

i

/

\\

    • Class / Procurement Level: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor: Not on File Supplier:

Not on File.

Manufacturer:

Not on File.

QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature 7[M [_

Date

/

w The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

Attachment I Fastener Testing Data Sheet

  • Sample ID# VCS-81535 Item: BB Fastener

Description:

Capscrew 1/2" - 20 x 3" Purchase Order:

  1. Unknown Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File Head Marking (Specification and Manuf acturer) A5TM A449 TYPE 1 MANUFACTURER I

UNDETERMINED M.

V. 'i

/

\\

    • Class / Procurement Level: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor: Not on File Supplier: Not on File Manufacturer:

Not on File QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature 7 Date

/,

The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

Attachment I Fastener Testing Data Sheet "Sample ID# VCS-81546 Item: BB Fastener

Description:

1/2" Nut Purchase Order:

  1. Unknown

- Description of Sample Stock Location: Non-Safety Bins -

Warehouse C Material Specification es Documented by Licensee Records:

Not on File Head Marking (Specification and Manufacturer): None Assumed ASTM A563 Grade B

    • Class / Procurement Level: Non-Safety General Plant Application (e.g.,

Pressure Boundary, Structural)

Various Vendor: Not on File Supplier:

Not on File.

Manufacturer:

Not on File.

QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature M [

[~

Date

/ /a /4 4 The sample ID# shall have a prefix that contains the licensee j

facility initials.

    • If applicable, please provide an explanation for your classification system.

i i

Attachment I Fastener Testing Data Sheet

  • Sample ID# VCS-81529 Item: CC Fastener

Description:

1/2" Hex Nut Purchase Order:

  1. Unknown Description of Sample Stock Location:Non-Safety Bins -

Warehouse C Material Specification as Documented by Licensee Records:

Not on File Head Marking (Specification and Manufacturer): None Assumed ASTM A563 Grade B

    • Class / Procurement Level: Non-Safety General Plant Application (e.g., Pressure Boundary, Structural)

Various Vendor: Not on File Supplier:

Not on File.

Manufacturer:

Not on File.

QA Requirements Imposed on Vendor: None Licensee Representative: Mark G. Curtiss Signature 7

  1. 8,

,/

Date The sample ID# shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

l

b l

t ATTACF MENT OF ENC _OSURE V

I LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

501 MINUET LANE dL' )$

1 % [/f-P.O BOX 11297

a REIORP OF MNIERIAL VERPICATION TESP Clie7t: SOUTH CAIOLINA ELECTRIC & GAS 00.

Client's P.O. No.: Q478707 Material: Reported as Item A, 5/8"-11 UIX',

V.C. anumer Nuclear Station Office: Charlotte Metals A-563, Gr A, HH, CS Nut P.O. Box 88 Lab No.: CHS2524 Pg 1 of 31 Sample ID: VCS-81557 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Atin:

Ms. Kim Blough Tested Per: IAW, ASTM A-563-84 Guidelines and Client's Instructions IOCKWELL "B" TFSP RERTLTE LEIS Date Average Corrected Piece ?b.

Tested Readings Readina Peadino Comment 12-4-87-A-H1 12/4/87 90.8, 90.0, 92.2 91.0 90 Passed YENSION TESP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(sc. in.) (Ibs.)*

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Conment IDT REQUIRED-BY CLIENT

  • 0ffset=0.2%

OOGage=

CHEMICAL ANALYSIS TESP RESUIAS(%)

LEIS Date Piece Ib.

Tested _ Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum Vanadium Boron Comment 12-4-87-A-C1 12/17/87 0.46 0.01 0.01 Passed Respectfully submitted, Paviewed by:

LAW ENGINEERING INDUSTRIAL SERVICES Eckard M. Beck Chief Engineer q

f Larry E. Cobfe, Metals Laboratory Supervisor

1 LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

501 MINUET LANE

- $' ' 2 p

[*g % -(/

P.O. BOX 11297

  • CHARLOTTE NORTH CAROUNA 28220 fs (704)523-2022 REIDIT OF MATERIAL VERFICATION 'IEST Client: SOUTH CAIOLINA ELECTRIC & GAS 00.

Client's P.O. No. : Q478707 Material: Reported as Item B,1/2"-13 UNC, V.C. Summer Ibclear Station Office: Charlotte Metals A-563, Gr A, HH, CS Nut P.O. Box 88 Lab No.: CHS2524 Pg 2 of 31 Sample ID: NCS-81568 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Belcw Attn Ms. Kim Blough Tested Per:

IAW, ASTM A-563-84 Guidelines and Client's Instructions IOCKWHL "B" TESP RFSJLTS LEIS Date Average Corrected Piece tb.

Tested Readinqs Peadino Readino Comment 12-4-87-B-H1 12/4/87 97.4, 97.6, 97.8 97.6 98 Passed TENSION TESP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece tb.

Tested (in.)

(in.)

(sq. in.) (lbs.)*

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Coment IDT REQUIRED-BY CLIENT

  • 0ffset=0.2%

"Gage =

CHEMICE ANALYSIS TESP RPRILTS(%)

LEIS Date Piece ?b.

Tested Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum Vangdium Boron Comment 12-4-87-B-C1 12/17/87 0.12 0.02 0.01 Passed f7 Respectfully submitted, reviewed by:

LAW ENGINEERING INDUSTRIAL SERVICES Echard M. Beck Chief Engineer

{

g Larry E. 'Coble, Metals Laboratory Supervisor

1 LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

'*Q N)i

! / %. h m

$01 MINUET LANE i

P.O. BOX

  • 1297
  • CHARLOTTE. NORTH CAROLINA 28220 (704)523-2022 REIORP OP MATERIAL VERPICATION TESP Client: SOU'IH CAIOLINA ELECPRIC & GAS (D.

Client's P.O. Eb.: Q478707 Material: Reported as Item C,1"-8 UIC, V.C. Summer Ibclear Station Office: Charlotte Metals A-194, Gr 2H, HH, CSA Nut P.O. Box 88 Lab No.: CHS2524 Pg 3 of 31 Sample ID: VCS-81556 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per:

IAW, ASTM A-194-84 Guidelines and Client's Instructions FOCIGiELL "C" TESP RESULTS LEIS Date Average Corrected Pitce ?b.

Tested Readings Readino Reading CGment 12-s-87-C-H1 12/4/87 27.4, 26.5, 26.7 26.9 27 Passed TENSION TFSP RESULTS t

Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece ?b.

Tested (in.)

(in.)

(so. in.) (lbs.)*

(psi. ) *

(Ibs.)

(psi.)

(%)

(%)

Comment BOT REQUIRED-BY CLIENT

  • Offset =0.2%
    • Gage =

CHEMICAL ANALYSIS TESP RESULTS(%)

LEIS Date Piece ?b.

Tested Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum Vanadium Boron Cument 12-4-87-C-Cl 12/17/87 0.43 0.02 0.01 Passed

/'

Respectfully submitted, A

LAW ENGINEERING INDUSTRIAL SERVICES Paviewed by:

m Flward M. Beck Chief Engineer f.

f T

Larry E. (bble, Metals Iaboratory Supervisor

1 LAW ENGINEERING INDUSTRIAL SERVICES.

DIVISION OF LAW ENGINEERING,INC.

~,

501 MINUET LANE

- /h I' i' i 2 fi T -

P.O. BOX 11297

/

a REIORP OP MMPERIAL VERPICMPION TESP Client: fDUTH CAFOLINA ELECPRIC & GAS (D.

Client's P.O. No.: Q478707 Material: Reported as Item D,1"-8 UtK',

V.C. Summer Nuclear Station Office: Charlotte Metals A-563, Gr A, flH, CS Nut P.O. Box 88 Iab No.: CHS2524 Pg 4 of 31 Sample ID: \\CS-81540 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per:

IAW, ASIM A-563-84 Guidelines and Client's Instructions IOCKNELL "B" TPSP RESULTS LEIS Date Average Corrected Piece Ib.

Tested Readings Readino Readino Comment 12-4-87-D-H1 12/4/87 93.6, 94.5, 94.1 94.1 94.0 Passed TENSION TFSP RESULTS Diameter or Yield Yield Ultimate Ultinate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece ?b.

Tested (in.)

(in.)

(so, in.) (lbs. ) *

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Comment TDT REQUIRED-BY CLIENP

  • Offset =0.2%

"Gage =

CITEMICAL ANALYSIS TPRP RESULTS(%)

LEIS Ibte Piece No.

Tested Carbon Mancanese Phosphorus Sulfur _ Silicon Nickel Chromium Molybdenum Valudium Boron Comment 12-4-87-D-C1 12/17/87 0.19 0.02 0.01 Passed

}

Respectfully submitted, Peviewed by:

~

LAW ENGINEERING INDUSTRIAL SERVICES Eckard M. Beck Chief Engineer Larry E. Co'le, Metals Laboratory Supervisor b

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

i g-N[i $

I*

501 MINUET LANE P.O. BOX 11297

'f REIORP OP MATERIAL VEIFICATION TESP Client: SOUTil CAIOLINA EECTRIC & GAS (D.

Client's P.O. Ib.: Q478707 Material: Reported as Item E, 5/8"-11 UIE, V.C. Rimmer ?bclear Station Office: Charlotte Metals A-563, Gr A, IIII, CS Nut P.O. Box 88 Lab No.: CHS2524 Pg 5 of 31 Sample ID: NCS-81543 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per:

IAW, ASrt! A-563-84 Guidelines and Client's Instructions IOCKWEIL "B" TEST RESULTS

~

LEIS Ibte Average Corrected Piece ?b.

Tested Readinqs Readino Readino Comment 12-4-87-E-H1 12/4/87 97.4, 97.4, 96.4 97.1 97 Passed TENSION TESP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece ?b.

Tested (in.)

(in.)

(sa. in.) (lbs. ) *

(psi.)*

(lbs.)

(psi.)

(%)

(%)

Conment IOT REQUIRED-BY CLIENP

  • Offset =0.2%

C* Gage =

CITEMICM, ANALYSIS TESP RESULTS(%)

LEIS Date Picoe No.

Tested Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum vamdium Boron Coment 12-4-87-E<1 12/17/87. 0.07 0.02 0.02 Passed f'

Respectfully submitted,

/

Pcviewed by:

LAW ENGINEERING INDUSTRIAL SERVICES Edgard M. Deck Chief Engineer Larry E. Coble, Metals Laboratory Supervisor l

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING, INC.

!/

f 501 MINUET LANE P.O. BOX 11297

~

(704) 523-2022 s

REICIT OF MNIERIAL VERFICATION TESP Client: SOU'HI CAFDLINA ELECTRIC & GAS 00.

Client's P.O. No.: Q478707 Material: Peported as Item F, 1/2"-20 UNF, V.C. Stimmer Nuclear Station Office: Charlotte Metals A-194, Gr 2H, IHI, CSA Nut P.O. Ibx 88 Lab No.: CHS2524 Pg 6 of 31 Sample ID: VCS-81544 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: IAW, ASrM A-194-84 Guidelines and Client's Instructions FOCKWFJL "C" TEST RFS1LTE LEIS Date Average Corrected Piece Ib.

Tested Peadinos Readim Readino Comment 12-4-87-F-H1 12/4/87 28.7, 28.3, 28.9 28.6 29 Passed TENSION TFSP RESULTS Diameter or Yield Yield Ultinate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(sq. in.) (lbs.)*

(psi,) * (lbs.)

(psi.)

(%)

(%)

Ccanent IOT REQUIRED

  • 0ffset=0.2%
    • Gage =

CIIEMICAL ANALYSIS TFSP RESULTS(%)

LEIS Date Piece Ib.

Tested Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Molv_ba _nutn_Wnadium Ibron Comment s

Passed 12-4-87-F-Cl 12/17/87 0.40 0.02 0.01

)

Respectfully ersbmitted,

~

Pcviewed by.

LAW ENGINEF. RING INDUSTRIAL SERVICES F& ard M. Beck Chief Engineer Larry E. Cobl6 Metals Laboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

f 501 MINUET LANE L' k f >

ig/

i>

P.O. BOX 11297

(704) 523-2022 s

REIORP OF MNFERIAL VEIFICATION TESP Client: fDUTH CAIOLIta ELECTRIC & GAS (D.

Client's P.O. No.: Q478707 Material: Reported as Item G, 9/16"-12 UtC, V.C. Sununer tbclear Station Office: Charlotte Metals A-194, Gr 8, HH, SS Nut P.O. Box 88 Lab No.: CHS2524 Pg 7 of 31 Sample ID: VCS-81542 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: INi, ASTM A-194-84 Guidelines and Client's Instructions IOCKWELL "B" TEST RESULTS LEIS Date Average Corrected Piece ?b.

Tested Peadinos Readino Readino Comment 12-4-87-G-H1 12/4/ 87 71.3, 73.4, 73.4 72.7 73 Passed TENSION TESP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(sa. in.) (lbs.)*

(psi.)*

(1bs.)

(psi.)

(%)

(%)

Carent PDT REQUIRED-BY CLIENT

  • Offset =0.2%
    • Gage =

CHEMICAL ANALYSIS TESP RESULTS(%)

LEIS Date Pie Ib.

Tested Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Fblvbdenum TbIndjum Boron Comment 12-4-87-G-C1 12/17/87 0.077 1.07 0.01 0.01 0.38 9.01 19.17 Passed

/'//j//

Respectfully submitted, LAW ENGINEERING INDUSTRIAL SERVICES Pcviewed by:

Edgard M. Beck Chief Engineer 7

g Larry E. Cobfe, Metals labcratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES

~

DIVISION OF LAW ENGINEERING, INC.

./

501 MINUET LANE

/

~*]

h F

P.O. BOX 11297

REIORP OP MMERIAL VERPICATION TESP Client: SOU'lB CAROLINA ELECTRIC & GAS (D.

Client's P.O. Ib.: Q478707 Material: Reported as Item H, 9/16"-12 UlK',

V.C. Summer Ibclear Station Office: Charlotte Metals A-193, 87, CSA Stud P.O. Box 88 Iab lb. : CHS2524 Pg 8 of 31 Sample ID: VCS-81567 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Delow Attn: Ms. Kim Blough Tested Per: IAW, ASTM A-193-85a Guidelines and Client's Instructions IOCKWFJL "B" TI'SP RESULTS LEIS Date Average Corrected Piece Ib.

Tested Readings Readino Readino Comment ICT REQUIRED TFNSION TEST RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(sc. in.) (Ibs. ) *

(psi.)*

(lbs.)

(psi.)

(%)

(%)

Comment 12-4-87-H-Tl 12/8/87 0.377 0.1116 14,750 132,200 16,960 152,000 18.3 57.8 Passed

  • Offset =0.2%
    • Gage =1.500" CHEMICAL ANALYSIS TFSP RESULTS(%)

LEIS Date Catrb n Mangapese Phosphorus Sulflir_Sjtlicon Nickel Chromium oblybdenum Vanadium Boron Cor:nent Piece Ib.

Tested 9

12-4-87-IH'1 12/17/87 0.41 0.99 0.02 0.01 0.27 0.97 0.21 Passed

//

Respectfully submitted, Peviewed by:

_//////

7 LAW ENGINEERING INDUSTRIAL SERVICES Ectrard M. Beck Chief Engineer g

Larry E. Coble, Metals Laboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

!/

I' 501 MINUET LANE i

P.O. BOX 11297

(704) 523-2022 s

REIORP OF MNIERIAL VERFIClLTION TEST Clicnt: SDU'HI CARDLINA ELECTRIC & GAS 00.

Client's P.O. No.: Q478707 Material: Reported as Item I, 7/8"-14 UNF, V.C. Ebmmer Nuc1 car Station Office: Charlotte Metals A-307, Gr B, HH, CS Bolt P.O. Box 88 Iab No.: CHS2524 Pg 9 of 31 Sample ID: VCS-81559 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: IAW, ASTM A-307-84 Guidelines and Client's Instructions IOCKWETL "B" TFSP RESULTS LEIS Date Average Corrected Piece No.

Tested Readinos Readino Readino Comment 12-4-87-Il-H1 12/4/87 66.1, 66.7, 66.0 66.3 66 Failed-Low 12-4-87-I2-H1 12/4/87 69.7, 69.8, 69.9 69.8 70 Passed TENSION TEST REmLTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece No.

Tested (in.)

(in.)

(so in.) (lbs.)*

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Comment 12-4 2-T1 12/8/87 0.502 0.1979 10.750 54,300 13,840 69,900 20.9 62.9 Passed ***

  • Offset =0.2%

ofGage=2.000"

      • Unable to test full size CHD1ICM, ANALYSIS TEST RESULTS(%)

LEIS Date Piece No.

_ Tested Carbon Mancanese Phosphorus sulfur Silicon Nickel Chromium Moly _bdenum Vapadium Boron comment 12-4-87-Il-Cl 12/17/87 0.02 0.02 Passed 12-4-87-12-Cl 12/17/87 0 22 0.02 0.01 Passed Respectfully submitted, Revicaed by:

LAW ENGINEERING INDUSTRIAL SERVICES h ard M. Beck Chief Engineer g

Iarry E. Coble, Metals Laboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES l

DIVISION OF LAW ENGINEERING,INC.

j#

501 MINUET LANE Y d * 'h ! h P.O BOX 11297

0 (704)523-2022 g

n.

REIOIT OF MNIERIAL VERFICATION TESP Client: S0I7111 CNOLINA ELECTRIC & GAS 00.

Client's P.O. No.: Q478707 Material: Reported as Item J, 5/8"-11 UfK',

V.C. Summer fliclear Station Office: Charlotte Metals A-193, B7, HH, CSA Bolt P.O. Box 88 Lab No.: CHS2524 Pg 10 of 31 Sample ID: VCS-81562 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Belm Attn:

Ms. Kim Blough Tested Per:

IAW, ASTM A-193-85 Guidelines and Client's Instructions IOCKWELL "C" TFFf RESULTS LEIS Date Average Corrected Piece Ib.

Tested Peadings.

Readino Readino Comment FOT REQUIRED TENSION TEST RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece No.

Tested (in.)

(in.)

(sq. in.) (lbs ) *

(PSJ. ) *

(lbs.)

(psi.)

(%)

(%)

Comrrent 12-4-87-J-T1 12/8/87 0.379 0.1128 15,000 133,000 16,640 147,500 17.2 60.5 Passed

  • Offset =0.2%
    • Gage =1.500" CHEMICN, ANALYSIS TEST RESULTS(%)

LEIS Ibte Piece Ib.

Tested Carbon Manganese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum Vanadium Boron Comment 12-4-87-J-Cl 12/17/87 0.42 0.75 0.02 0.01 0.26 0.97 0.20 Passed A

l/

[s Respectfully submitted, LAW ENGINEERING INDUSTRIAL SERVICES P

ed by-

/

Edaard M. Beck Chief Engineer g

Larry E. Coble, Metals Laboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

- / h p a g' S.p 501 MINUET LANE 1 -

6.

P.O. BOX 11297

    • C ' '/

m-RITOItr OF MKIEZL, VERFICATION TEST Client: RXTIll CAFOLINA ELECIRIC & GAS (D.

Client's P.O. No.: 0478707 Material: Reported as Item K, 7/8"-9 UtK',

V.C. Summer Ibclear Station Office: Charlotte Metals A-325, Type 2, HH, CSA Polt P.O. Box 88 Iab No.: CHS2524 Pg 11 of 31 Sample ID: W.S-81558 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per:

IAW, ASTM A-325-85 Guidelines and Client's Instructions BOCIMELL "C" TFSP RESLTS LEIS Date.

Average Corrected Piece No.

Tested Readings Readino Readi m Comment 12-4-87-K-H1 12/4/87 26.4, 24.0, 25.9 25.4 25 Passed

_ TENSION TEST RESULTS Diameter or Yield Yield Ultinnte Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece 770.

Tested (JD,)

(in.)

(scT. in.) O bs. ) *

(p_sj. )

  • Gip.)

(psi.)

(%)

(%)

Comment 12-4-87-K-Tl 12/8/87 -Full Sizc 61,440 Passed

  • 0ffset=0.2%
    • Gage =

CID11 CAL ANALYSIS TEST RESLT.TS(%)

LEIS Ibte Piece Ib,_,

Tested Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum Vanadium Boron Comment 12-4-87-K-Cl 12/17/87 0.39 0.72 0.02 0.01

<0.0005 Failed *

(!faterial Spec. req

car. n of 0.13-0.37 and boron of 0.0005 mininum.

/

LAW ENGINEERING INDUSTRIAL SERVICES Reviewed by:

Eckard M. Beck Chief Engineer Tarry E. Coble, Metals laboratory R1pervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

' WL[' t '

t b 501 MINUET LANE P.O. BOX 11297

(

(704) 523-2022 REIORP OF MATERIAL VERFICATION TESP Client: EOUTH CAFDLINA ELECPRIC & GAS 00.

Client's P.O. No.: Q478707 Material: Reported as Item L, 1/2"-13 UNC, V.C. S2mmer Nuclear Station Office: Charlotte Metals A-325, Type 2, HH, CSA Bolt P.O. Box 88 Iab Ib.: CHS2524 Pg 12 of 31 Sample ID: VCS-81565 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Belm Attn:

Ms. Kim Blough Tested Per:

IAW, ASTM A-325-85 Guidelines and Client's Instructions IOCKWELI, "C" TESP RERTLTS LEIS Date Average Corrected

_P_jece Ib.

Tested Readinos Read _ipo Readino Comment 12-4-87-IcH1 12/4/87 29.5, 28.9, 29.2 29.2 29 Passed TENSION TESP RFSJLTS Diameter or Yield Yield Ultimate Ultimate Elongation Paduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece ?b.

Tested (in.)

(in.)

(sa. in.) (lbs.)*

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Comment 12-4-87-IcT1 12/8/87 -Full Sizc 20,320 143,100 Fassed

  • 0ffset=0.2%
    • Gage =

CHEMICAL ANALYSIS TESP RESULTS(%)

LEIS Date "iece tb.

Tested Carbon Mancanese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum Vanadium Boron Comment

<0.0005 Failed

  • 12-4-87-IcC1 12/17/87 0.40 0.72 0.02 0.01 and boron of 0.0005 mininum. Respectfully submitted, eMaterial Spec. r

'.. ca r,

of 0.13-0.37 LAW ENGINEERING INDUSTRIAL SERVICES Revised by:

Edward M. Beck Chief Engineer g

Inrry E. Coble, Metals Iaboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES

'#~

DIVISION OF LAW ENGINEERING,INC.

h 501 MINUET LANE i g ;/

P.O. BOX 11297

(704)523-2022 s

REIOIT OP M/GERIAL VERPICNfl0N TESP Client: S00'III CAIOLINA ELECTRIC & GAS 00.

Client's P.O. No.: 0478707 Material: Reported as Item M,1/2"-13 UIC, V.C. Ebmmer Nuclear Station Office: Charlotte Metals Ir-307, Gr A, IHI, CSA Bolt P.O. Box 88 Lab No.: CllS2524 Pg 13 of 31 Sample ID: VCS-81564 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: IN1, ASTM A-307-84 Guidelines and Client's Instructions IOCIGiFIJ, "B" TESP RPRLTS LEIS Date Average Corrected Piece tb.

Testgd Ik;Ld.inas Reading Readino Comment.

c_

12-4-8.7-M-H1 12/4/87 101.5, 101.2 100.2 101.0 101 Passed TENSION TEST RESULTS Diameter or Yield Yield Ultinate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area

_ Piece Ib.

Tested (in.)

(in.)_

(ro in.) (Ibs.)*

(osi. ) *

(Ibs.)

(psi.)

(%)

(%)

comment 12-4-87-ti-T1 12/8/87 -Full Size --

14,240 100,300 Passed

  • Offset =0.2%
    • Cage =

CIID1TCAL ANALYSIS TESP RESULTS(%)

LEIS Date Piece _lb.

_ Tested _ _ Carbon Manganese Phosphorus Sulfur Silicon Nickel Chromiu::Llblybdenum vanadium Ecron C.

IP4-b /-IN 1Z/ 1// U/

U.UU U.UJ U.U1 Fasc f,,

Respectfully submitted, LAW ENGINEERING INDUSTRIAL SERVICES Peviewed by:

_E&ard M. Ecck Chief Engineer M

[

g Larry E. Ct$61e, Metals Iaboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

501 MINUET LANE d*

I>

t)

P.O. BOX 11297

u - #

(704)S23-2022 REIORP OF MATERIAL VERFICATION TESP Clitnt: SOUTil CAPOLINA ELECTRIC & GAS 00.

Client's P.O. Ib. : Q478707 lbterial: Peported as Item N, 7/8"-9 UIC, V.C. Stumer fliclear Station Office: Charlotte Metals A-490, Type 1, HII, CSA Bolt P.O. Box 88 Iab No.: CIIS2524 Pg 14 of 31 Sample ID: VCS-81560 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per:

IAW, ASr?1 A-490-84 Guidelines and Client's Instructions IOCIGVEIL "C & B" TFSP RFE)LTS LEIS Date Average Corrected P_iece Ib.

Tested Peadinas Readino Readino Comment 12-4-87-rFH1 12/4/87 22.6, 22.9, 20.9 22.2 22 Failed-Low 12-4-87-?FH2 12/4/87 95.3, 97.6, 92.0 95.0 95 Failed-Iow TETSION TEST RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area f g._jIt,) Obs. ) *

(psi. ) *

(IbJ.)

(psi.)

(%)

(%)

Comment Piece ?b.

Tested (in.)

(in.)

i 12-4-87-thTl 12/8/87 -Full Sizc 74,080 160,300 Passed

  • Offset =0.2%
  • CGage=

CIID1ICAL ANALYSIS TFSP RESULTS(%)

LEIS Date Cpgb_ OIL tnoanese Phosphorus Sulfur Silicon Nickel Chromium Molybdenum vaInd_ilu_m__Bofpn Comnent Piece tb.

Tg_sted f

12-4-87-tK1 12/17/87 0.46 0.03 0.01 Passed l

l Respectfully submitted, Peviewed by: /

~

LAW ENGINEERING INDUSTRIAL SERVICES E&ard M. Beck Chief Engineer Iarry E. Cob 1'e, Metals Inboratory Stipervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

!/ [*

(h 501 M:NUET LANE i 3s

-[

P.o. BOX 11297

  • CPAPLOTTE, NORTH CAROUNA 28220 (704)523-2022 f

%.e v v REIDIT OF MATERIAL V13FICATION 'ITSP Client: SXTIll CAPOLINA ELECTRIC & GAS 00 Client's P.O. No.: Q478707 Material: Reported as Item O, 3/4"-10 UtE, V.C. SLmmer fliclear Station Office: Charlotte Metals A-193, Gr B7, HII, CSA Bolt P.O. Box 88 Lab No.: CIIS2524 Pg 15 of 31 Saaple ID: VCS-81555 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Belm Attn: Ms. Kim Blough Tested Per: IAW, ASTM A-193-85 Gaidelines and Client's Instructions IOCKWEEL "C" TFSP RESJLTS LEIS Ibte Average Corrected Pieg tb.

Tested Readinos Readino Readino Comment 107 REQUIRED TENSION TFSP RESULTS Diameter or Yield Yield Ultimate Ultinate Elongation Reduction LEIS Ibte Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece ?b.

Tested (in.)

(in.)

(so. in.) O bs. ) *

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Comment 12-4-87-O-Tl 12/8/87 0.499 0.1956 25,750 131,600 29,520 150,900 18.8 63.9 Passed

  • Offset =0.2%

CcGage=2.000" CID1ICAL ANALYSIS TEST RESULTS(%)

LEIS Date Piece ?b.

Tgsted Car _ bod _lbngngse Phosphorus S111f_ur_EJ1JspD Nickel _ Chromium nelytLacItuerpaium Boron Comnent 12-4-87-O-Cl 12/17/87 0.38 0.77 0.02 0.01 0.24 1.02 0.19 Passed

/ f Respectfully submitted, LAW ENGINEERING INDUSTRIAL SERVICES Pmrimed by:

Ethard M. Beck Chief Engineer 3-Larry E. C661e, Metals Laboratory Ebpervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

/

501 MINUET LANE

!/

(j)

' 'Q

'\\

fa P O BOX 11297

  • CHARLOTTE. NORTH CAROLINA 28220 (704) 523-2022 REIDIT OF MILTERIAL VERFICNflON TESP Client: SXml CAFDLINA ELECTRIC & GAS (D.

Client's P.O. Ib. : Q478707 Material: Reported as Item P,1/2"-13 UIC, V.C. & mmer Nuclear Station Office: Charlotte Metals A-193, Gr B8, Cl 1, HH, SS Bolt P.O. Box 88 Iab No. : CHS2524 Pg 16 of 31 Sample ID: VCS-81563 Jenkinsville, S.C.

29065 Date: Decerr.ber 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per:

IAW, ASTM A-193-85 Guidelines and Client's Instructions IOCKWEIL "B" TEST RESULTS LEIS Date Average Corrected Piece ?b.

Tested Readinqs Peitdino Readino Comant 12-4-87-P-H1 12/4/87 82.7, 79.7, 79.8 80.7 81 Passed TENSION TEST RESULTS Diameter or Yield Yield Ultimate Ultirrate Elongation Reduction LEIS Date Width Thickness Area Lead Stress Load Stress in ** Ins.

of Area Piece ?b.

Teste_d (in.)

(in.)

(sq._in.) (Ibs.)*

(psi. ) *

(Ibs.)

(psi.)

(%)

(%)

Conrent 12-4-87-P-Tl 12/8/87 0.252 0.0499 2,000 40,100 4,480 89,800 59.9 72.5 Passed

  • Offset =0.2%

CCGage=1.000" CHEMICAL ANALYSIS TFSP RESULTSB)_

LEIS Date Piece ?b.

Tested Carbon Mancanese Phosphorus St 1 fur Silicop Nickel Chromium Molybdenum Vanadium Poron 12-4-87-P-Cl 12/17/87 0.06 1.06 0.01 0.02 0.34 8.15 18.71 iw sed

/

Respectfu!!y submitted, Pcviewed by:

//

LAW ENGINEERING INDUSTRIAL SERVICES Ethard M. Beck Chief Engineer Iarry E. Go61e, Metals Iaboratory &pervisor-

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

/

i y/*yi'

fi 501 MINUET LANE P.O. BOX 11297

.g

'[

.s>

REIORP OF WaTRIAL VERFICATION TESP Client: SOU'HI CAFDLINA ELECIRIC & GAS 00.

Client's P.O. Ib.: 0478707 Material: Reported as Item 0, 3/4"-16 Ur:P, V.C. 32mmer t&lclear Station Office: Charlotte Metals A-193, Gr D8, Cl 1, HH, SS Bolt P.O. Box 88 Iab tb.: CIIS2524 Pg 17 of 31 Sample ID: VCS-81561 Jenkinsville, S.C.

29065 Date: Decenber 18, 1987 Date Tested: See Bel m Attn:

Ms. Kim Blough Tested Per:

IAW, ASIN A-193-85 Guidelines and Client's Instructions IOChWEIL. "B" TFSP_BESJLTS LEIS Date Average Corrected Piece Ib.

Tc_sted Pcadings Readino Readino Comment 12-4-87-O-111 12/4/87 81.6, 84.2, 83.2 83.0 83 Passed

'ITNSION TFSP RESULTS Diameter or Yield Yield Ultinnte Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece tb.

Tested (in.)

(in.)

(sq. __ in. ) (Ibs. ) *

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Connent 12-4-87-0-T1 12/8/87 0.379 0.1128 7,000 62,100 10,720 95,000 51.1 74.3 Passed

  • 0ffset=0.2%

ScGage=1.500" CHEMICAL ANALYSIS TESP RESULTS(%)

LEIS Ibte Piece Ib.

Tested Car _ bon Mangnese PhosphoJ_uS_S_uJfur Silicon _ Nickel Chromium Molybd mm Vbnadium__Doron Comment J

m 12-4-87-O-Cl 12/17/87 0.07 0.13 0.01 0.02 0.43 8.25 19.01 Passed l

LAW ENGINEERING INDUSTRIAL SERVICES Respectfully submitted,

/ 4

/4. '

Pcviewed by:

/

PdJard M. Deck Chief Engineer Iarry E. Coble, Metals Iaboratory R1pervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

. j-T / i;h'd'h U

!4 501 MINUET LANE i) i2 P.o. Box 11297. cHARLOTT E. NORTH CAROUNA 28220 (704)523-2022 REIDIT OP PUmRIAL VEIFICATION TEUr Client: S0lmi CANDLINA ELECTRIC & CJ\\S W.

Client's P.O. No.: 0478707 lbterial: reported as Item R, 3/4"-16 UI.T, V.C. Sr:ner !bclear Station Office: C!nclotte Metals A-354, Gr PD, IIH, CSA Cap Screw P.O. Box 88 Inb No. : 01S2524 Pg 18 of 31 Sample ID: VCS-81534 Jenkinsville, S.C.

29065 Date: Decenber 18, 1987 Date Tested: See Below Attn: fis. Kim Blough Tested Per: IAW, ASIM A-354-84 Guidelines and Client's Instructions IDCIMEU; "C" TESP RESLTS LEIS Date Average Corrected Piece No.

Tested PevliJLg;;

Readirx1 Readim Cortnent 12-4-87-R-H1 12/4/87 35.9, 35.5, 35.1 35.5 36 Passed TENSION TESP RESULTS Diameter or Yield Yield Ultinate Ultirrate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece No.

Tested (in.)

(in.)

(sq._in. ) (lbs. ) *

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Carent IUr REQUIRII

  • 0ffset=0.2%

cc' Gage =

CHEMICAL _ ANALYSIS TESP RESULTFJM LEIS Ihte

Eifce_Jh, Teat _ed Carbon ManganEp_ff)o_sphoru;L_Su] fur SJJj_coJL jcl eJ__Chy_opti_um_1*p}ybdspuM)nadJltm_FoI_on Co u nt N L Passed 0.03 0.01 12-4-87-R-Cl 12/37/E7 0.39 lhl Respectfully submitted, LAW ENGINEERING INDUS' RIAL SERVICES Pcviesed by:

j E&ard M. Beck Chief Ehgineer g

g Larry E. Coble, P'etals Taboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

j.

501 MINUET LANE g; t th i

P.O DOX 11297

  • CHARLOTTE. NORTH CAROLINA 28220 i ADf (704)523-2022 REIOlF OF MATERIAL VERFICNTION TEST Client: SOUIII CAIOLII;A ILECTRIC & GAS (D.

Client's P.O. Ib. : 0478707 Fbterial: Pcported as Item E, 3/4"-16 L7.T, V.C. Rimmer IA2 clear Station Office: Charlotte Metals A-563, Gr B, IIII, CS Nut P.O. Dox 88 Inb No. : CIIS2524 Pg 19 of 31 Sample ID: VCS-81547 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: INf, ASrM Ir-563-84 Guidelines and Client's Instructions IOCKWEIL 'B" TFSr RERL_TS LEIS Date Average Corrected Piece ?b.

Tested Readinos Readino Readim Comment 12-4-87-R-H2 12/4/87 95.4, 95.4, 91.6 94.1 94 Passed 12-4-87-R-lG 12/4/87 95.7, 95.0, 96.2 95.6 96 Passed TE?SION TEST RERLTS Diameter or Yield Yield Ultitrate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(ca. in.) (Ibs,) *

(psi. ) *

(Ibs.)

(psi.)

(%)

(%)

Coment IUr REQUIPED

  • Offset =0.2%

acGage=

CID1ICN, ANALYSIS TFSr RESILTS(%)

LEIS Date Piece Ib.

Tested Carbon Mancanere Phosphorus Sull_f._ur Sillcpn Nickel Chromium Molytdenum Wmdium Boron Comment 12-4-87-R-C2 12,'17/87 0.12 0.02 0.02 Passed

/!

Respectfully submitted, Pev h ed by-f LAW ENGINEERING INDUSTRIAL SERVICES Edeard M. Beck Chief Engineer Larry E. Cotile, Metals Inboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

  • "[h" *.

m-

h 501 MINUET LAtJE P O. BOX 11297

^

(704l 523-2022 REEDIT OF MITT.tIAL VERFICATIDN TEST Client: HXTHI CAFOLINA ELECIIIIC & CAS 00.

Client's P.O. Ib.: Q478707 Material: Reported as Itera S, 3/4"-10 UNC, V.C. Rmraer Ibclear Station Office: Charlotte Metals A-449, IIH, CS Bolt P.O. Ibx 88 Lab Ib. : CHS2524 Pg 20 of 31 S2ple ID: VCS-81536 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: IAF, ASTM A-449-84 Guidelines and Client's Instructions IOCKWELL "C" TPSP RFELTS LEIS Ibte Average Corrected Piece Ib.

Tested Readinas Readim Readim Comment 12-4-87-S-H1 12/4/87 24.5, 25.2, 24.9 24.9 25 Passed TENSION TESP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area

, Piece Ib.

. Tested (in.)

(in.)

(mi. in.) (IbS. ) *

(rsi,) *

(1bS.)

(psi.)

(%)

(%)

Corrent IDT REQUIREE

  • Offset =0.2%

ocGage=

CilEMICAL ANALYSIS _TFST PESULTS(%)

LEIS Date Piece Ib.

Test _ed Cagbpp Mangapece Phospbonis SbJfur_S_ilicon_Eftekpl Chrogtim_EphtdCDutn_varg_dium Poron Corrent 12-4-87-S-C1 12/17/87 0.33 0.80 0.02 0.02 Passed fQ Respectfully submitted,

////j#7 c LAW ENGINEERING INDUSTRIAL SERVICES Pcviewed by:

Eckard M. Beck Chief Engineer Larry E. Cot (e, Metals Laboratory R!pervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

1 Q@Dhfi1

<l &

f>

501 MINUET LANE P.O BOX 11297

  • CHARLOTTE, NORTH CAROUNA 28220 (704)523-2022 REIVIG OF FMTERIAL VEIFICATION TESP Client: S[XIIii CAIOLINA ELECIRIC & Cidi (D.

Client's P.O. Ib. : 0478707 Material: Reported as Item S, 3/4"-10 UDC, V.C. Stimmer Ibclear Station Office: Charlotte Metals A-563, Gr B,101, CS IAlt P.O. Dox 88 Iab tb.: CIIS2524 Pg 21 of 31 Samp1.e ID: VCS-81545 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blcugh Tested Per:

IAN, ASTM A-563-84 Guidelines and Client's Instructions ROCKWEIL "B" TFSP REfULTS LEIS Date Average Corrected Pealjnq Comment l

Piece _fb, Tested Readings Readino 12-4-87-5-112 12/4/87 95.4, 96.5, 97.9 96.6 97 Passed TFNSION TESP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area

_Pjece Ib.

Tested (in.)

(in.)

(sa. in.) (Ibs.)*

(psi. ) *

(Ibs.)

(psi.)

(%)

(%)

Corrent; IUP RDQUIPED

  • Offset =0.2%

" Gage =

CIIEMICN, AFIALYSIS TESP RESULTS(%)

LEIS Date Canton Manganese Phosphorus Sulf _ur Silicon NinkeJ_Ciromium Molytxisnum vandium Poron Can,eILt Piece ib.

Tected L

e 12-4-87-S-C2 12/17/87 0.12 0.02 0.02 Passed

/, f Respectfully submitted, LAW ENGINEERING INDUSTRIAL SERVICES Pcviewed by:

f

^

E&ard M. Beck Chief Engineer Larry E. Coble, Fictals Laboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES

'q DIVISION OF LAW ENGINEERING,INC.

  • Q/%[(* P -

h sot tmUET LANE P.O BOX 11297

REIORT OP MNPERIAL VEIFICATIDN TEST Client: SOL'111 CAPOLINA ELECTRIC & GAS 00.

Client's P.O. No.: Q478707 Material: Peported as Item T, 3/4"-10 UNC, V.C. Snmer ?bclear Station Offi

Charlotte Metals A-574, Gr 4140, SH, CSA Cap Screw P.O. Box 88 Lab tb.: CHS2524 Pg 22 of 31 Sample ID: VCS-81541 Jenkinsville, S.C.

29065 Date: Decenter 18, 1987 Date Tested: See Below Attn:

Ms. Kira Blough Tested Per:

INf, ASTM A-574-84 Guidelines and Client's Instructions FOCKWELL _"C" TEST RESLTE LEIS Date Average Corrected Ele _ce ?b.

Tested PeadJngs Reading Pcadino Comment 12-4-87 'F-H1 12/4/87 31.0, 34.2, 26.0 30.4 30 Failed-Low 12-4-87 'F-H2 12/4/87 33.7, 34.7, 32.4 33.6 34 Failed-Iow TENSION TEST RESLTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Ibte Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piem lb.

Tested (in.)

(in.)

(Eq. in.) (1bs. ) *

(psi.)*

(lbs.)

(psi.)

(%)

(%)

Corrent POT REQUIRED

' Offset =0.2%

CCGage=

CHEMICAL ANALYSIS TEST RESULTS(%)

LEIS Ibte Piece _?b.

Tc;Ltpsd Carbon Manganese Phosphorus Sul_f_ur Si1Jcon_ Nickel Chr_omi_usttiphitdsnun vanadium rqron Ccent; 12-4-87 'P-C1 12/17/87

.41 0.72 0.02 0.01 0.29 0.85 0.05 Passed Respectfully submitted, Peviewed by:

LAW ENGINEERING INDUSTRIAL SERVICES Eckard M. ' Deck Chief Engineer Larry E. Colile, Fetals Laboratory SJpervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

g t,,

ff "}3*

fi 501 MINUET LANE qi i

P.O. DOX 11297

  • CHARLOTTE. NORTH CAROUNA 28220 (704)523-2022 REIOl& OF MATERIAL VERFICATION TESP Client: SOU'IH CAROLINA ELECITtIC & GAS C0.

Client's P.O. Ib.: 0478707 Material: Pcported as Itan U,1"-14 UHF, V.C. Ibn:ner Nticlear Station Office: Charlotte Metals A-449, HH, CS Cap Scrw P.O. Fox 88 Lab lb. : CHS2524 19 23 of 31 Sample ID: VCfr-81537 Jenkinsville, S.C.

29065 Date: Decenber 18, 1987 Ibte Tested: See Below Attn:

Ms. Kim Blough Tested Per: 1AW, ASn1 A-449-84 Guidelines and Client's Instructions TOCIMFIL "C" TFSP RESUL_TS LEIS Date Average Corrected Piece Ib.

Tested Readims Readi_m Readim Congsnt 12-4-87-U-H1 12/4/87 29.7, 31.0, 29.9 30.2 30 Passed TENSION TEST RESULTS Diameter or Yield Yield Ultimate Ultinate Elongation Pcduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of.31ea Piece Ib.

Tested (in.)

(in.)

(sci. in.) (lbs. ) *

(psi.)*

(lbs.)

(psi.)

(%)

(t)

Convent IDT REQUIRED

  • Offset =0.2%

"Gage =

CHEMIClg, ANALYSIS TFSP RESULTS(%)

LEIS Date Piem ib.

Tested Carbon Manginese Phosphorns SbJfuJ Silicton NickeJ__Chr_calum Molybdenum vdigdium tyron Corment 12-4-87-tK1 12/17/87 0.42 0.96 0.02 0.03 Passed l

Respectfully submitted, 4'

LAW ENGINEERING INDUSTRIAL SERVICES Pcviewed by:

Eckard M. Beck Chief Engineer Larry E. Coble, Metals laboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

~. #

50i u:NUET LANE

<!/

f +

i P O BOX 11297

(704)523-2022

& ?-

REIORP OF IMTERIAL VERPICATION TEST Client: SXTI1! CAPOLINA ELECTRIC & GAS CD.

Client's P.O. No.: Q478707 Material: Reported as Itera V,1/2"-20 UNF, V.C. Stumer Iliclear Station Office: Charlotte Metals A-354, Gr ID, is*. CSA Cap Scrm P.O. Box 88 Iab lb. : CHS2524 Pg 24 of 31 Sample ID: VCS-81533 Jenkinsville, S.C.

29065 Date: Decenber 18, 1987 Date Tested: See Belm Attn:

Ms. Kim Blough Tested Per: IAW, ASIM A-3S4-04 Cuidelines and Client's Instructions FOCWEy, "C" TFSP RESJLTS LEIS Date Average Corrected Piece ?b.

Tested Ppmtinos Peadino Peadino Comment 12-4-87-V-H1 12/4/87 32.0, 31.9, 34.7 32.9 33 Passed TENSION TFSP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(sq. in.) (1bs. ) *

(psi. ) *

(lbs.)

_ (psi.)

(%)

i%)

Corinent N7f REQUIRED

  • Offret=0.2%
    • Cage =

CHEMIClg, ANALYSIS TEST RESULTS(%)

LEIS Ibte Piece 'b.

Tesied Cnhon Tbnnanese Phosphpf_u;;_jb11ur Silftcpn Nickel _ChLo_mjirt Moly 1L enum VaIndium DoIpn Corment d

12-4-87-V-Cl 12/17/87 0.40 0.02 0.02 Passed 9

Respectfully submitted, Pcviw ed by-

/'

LAW ENGINEERING INDUSTRIAL SERVICES Edvard M. Ecck Chief Engineer Larry E. Cobl6, Metals Laboratory Rpervisor

LAW ENGINEERING INDUSTRIAL SERVICES

~

DIVISION OF LAW ENGINEERING,INC.

! /0 %,[" i p

501 MINUET LANE P O. BOX 11297

(704)523-2022 REIDIE OF MMERIAL VERFICATION 'IESP Client: SOU'HI CMOLINA ELECTRIC & GAS 00.

Client's P.O. Ib.: Q478707 Material: Peported as Item W,1/2"-13 UNC, F-593, V.C. Ebmmer Ibclear Station Office: Charlotte Metals Alloy 303, Cond. 01, HIf, SS Bolt P.O. Box 88 Lab Ib.: CIIS2524 Pg 25 of 31 Sample ID: VCS-81531 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: IAW, ASIM F-593-84 Guidelines and Client's Instructions TOChMEIL "C" TESP RESULTS LEIS Date Average Corrected Te;L_ed Egadinos Readina Pepdino Comment Piece fb.

t 12-4-87-W-H1 12/4/87 30.1, 30.3, 31.1 30.5 31 Passed

_T_ENSION TESP PISULTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in,)

(in.)

(sq. in.) Obs. ) *

(psi.)*

(Ib_.)

(psi.)

(%)

(%)

Comment s

IDT REQUIRED-BY CLIDE

  • 0ffset=0.2%

CcGage=

gjEMICM. ANALYSIS TFSP RESULTS(%).

LEIS Date Piece Ib.

Tested Carbon ManfLaneseD;;pitor_us Sulfur _Eilicon Nickel Chrpmium Mdybdenum Vapadium Doron Conment; 12-4-87-tK1 12/17/87 0.09 1.63 0.01 0.01 0.57 7.89 17.90 Failed

  • cMaterial Spec. rt.

gnic 1 of B.00-10.00 and sulfur of 0.15 mininomRespectfully submitted,

/gf LAW ENGINEERING INDUSTRIAL SERVICES FA ard M. Beck Chief Imgineer

[

[f/

Larry E. Coblt6 Metals Iaboratory SDPervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

h

< / %*1.".

501 M:NUET LANE 3 %;

P.O BOX 11297

  • CHARLOTTE. NORTH CAROLINA 28220 (704)523-2022 1u201" OP 1%TERIAL VERFICATION TESP Client: SOU'H1 C180 LINA IIECTRIC & GAS (D.

Client's P.O. Ib.: Q478707 Paterial: Peported as Item X, 3/4"-10 UNC, F-593, V.C. SLmrer Ibclear Station Office: Charlotte Metals Alloy 303, Cond. 01, IIII, SS Bolt P.O. Ibx 88 Iab lb.: CIIS2524 Pg 26 of 31 Sample ID: VCS-81538 Jenkinsville, S.C.

29065 Date: December 18, 1987 Ibte Tested: See Belcw Attn:

PE. Kim Blough Tested Per: IAW, ASIM F-593-84 Guidelines and Client's Instructions IOCIGiELL "C" TEST RESULTS LEIS Date Average Corrected Pjece Ib.

Tested Feadjngs Feadipo Peadim Com[rcILt 12-4-87-X-H1 12/4/87 35.1, 36.8, 35.7 35.9 36 Failed-Iligh TmSION TFSP RESULTS Diameter or Yield Yield Ultinate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(m. in.) O bs. ) *

(psi. ) *

(Jb_s,)

(psi.)

(%)

(%)

Comment _

IDT REQUIRID-BY CLIENT

  • Offset =0.2%

ofCage=

CIlmICAL NFLYSIS TEST RESULTS(%)

LEIS Ihte Piece Ib.

Tested Carbon Fanqanese Phosphorus Sulfur _ Silicon Nickel Chromium Molybdenum vanadium Toron Ccmnent 12-4-87-X-C1 12/18/87 0.13 1.07 0.02 0 01 0.39 7.%

17.92 Failed

  • cfaterial Spec. requ' (nick 1 of 8.00-10.00 and sulfur of 0.15 mininum. Respectfully submitted, LAW ENGINEERING INDUSTRIAL SERVICES Pevicwed by:

,F&ard M. Peck Chief Ehgineer

(

Larry E. Cpbfe, Metals Iaboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

g 501 MINUET LANE I /F;d' 1-i P O. BOX 11297

  • CHARLOTTE. NORTH CAROUNA 28220 1 Qk*

)

(704)523-2022 REIOIT OF MNIERIAL VEIFICATION 'IEST Client: SOLTIll CNOLINA ELECTRIC & GAS 00.

Client's P.O. Ib.: Q478707 Material: Reported as Item Z, 5/8"-11 UtX', F-593, V.C. Rzmmer Ibclear Station Office: Charlotte Metals Alloy 303, Cond. G1, SII, SS Cap Scre,i P.O. Box 88 Iab Ib.: CHS2524 Pg 27 of 31 Sample ID: VCS-81539 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: INf, ASIf1 F-593-84 Guidelines and Client's Instructions IOCKWFLL "B" TESP RFSILTS LEIS Date Average Corrected Pie w tb.

Tested Readings Readipo Readino Cgin_en1 12-4-87-Z-H1 12/4/87 101.7, 104.2, 95.7 100.5 101 Passed 12-4-87-Z-H2 12/4/87 99.3, 98.6, 99.9 99.3 99 Passed TENSION TESP RERTLTS Diameter or Yield Yield Ultimate Ultimate Elongation Reduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(sa, in.) (lbs. ) *

(psi. ) *

(lbs.)

(psi.)

(%)

(%)

Coment fur REQUIRED-BY Q,IEt(f

  • Offset =0.2%

COGage=

CHEMICM, ANALYSIS TFSP RESULTS(%)

LEIS Date Piece Ib.

Tested Carbon Fangapese Phosphorus Sulfur SiJjcon Nickel Chromj_um Molybdgnum vppadium Foron Corrent 12-4-87-Z-Cl 12/18/87 0.03 1.48 0.02 0.01 0.51 8.04 17.99 Failed

  • cMaterial Spec. r

.s fur of 0.15 minimm.

Respectfully submitted, LAW ENGINEERING INDUSTRIAL SERVICES Peviewed by:

Phiard M. Beck Chief Engineer

[

f Larry E. Go61e, Metals Laboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

f8 /M'.' g,

fi 501 MINUET LANE i{^4$

'i P.O BOX 11297

REIDIT OF MNIERIAL VERFICATION 'IESP Clicnt: SOUTII CAFDLINA ELECTRIC & GAS 00.

Client's P.O. No.: Q478707 Material: Reported as Item AA, 1/2"-13 U?C, V.C. Rimmer Eliclear Station Office: Charlotte Metals A-449, HH, CSA Cap Scrm P.O. Box 88 Iab No.: CHS2524 Pg 28 of 31 Sample ID: VCS-81530 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Belm Attn:

Ms. Kim Blough Tested Per:

IAW, ASPM A-449-84 Cuidelines and Client's Instructions TOCENELL "C" TPSP RESJLTS LEIS Date Average Corrected P_iece Ib.

Tested Readjncs Readipo Readino Cpggtt 12-4-87-AA-H1 12/4/87 31.2, 29.8, 29.5 30.2 30 Passed TFNSION TEST RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in.)

(ca. in.) O bs. ) *

(psi. ) *

(Ibs.)

(psi. )

(%)

(%)

Convent IDT RDQUIRED-BY CLIEtIP

  • Offset =0.2%

"Gage =

CHD4ICAL ANALYSIS TESP RESULTSJ%)_

LEIS Date ige !b.

P Tested Car _ bon Fanganese Pho_spitoI_us Sul_ fur Silicon Nickel Ch1_omi_ualphi(_ enum Vanad_ium Dorpn Comment 12-4-87-AA-Cl 12/17/87 0.36 0.92 0.02 0.02 Passed lf Respectfully submitted, Peviewed by:

/

LAW ENGINEERING INDUSTRIAL SERVICES Edeard M. Beck Chief Engineer g

Larry E.pe, Metals Laboratory StJpervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING, INC.

4 501 MINUET LANE I/;

P O BOX 1W97

(704)523-2022

  • g REIDIT OF MNIERIAL VERFICATION TEST Client: SOLTI11 CAFDLINA ILECPRIC & GAS (D.

Client's P.O. Ib. : Q478707 Material: Reported as Item BB,1/2"-20 UNF, V.C. Summer 112 clear Station Office: Charlotte fletals A-449, IHi, CS Cap Screw P.O. Box 88 Iab !b.: CIIS2524 Pg 29 of 31 Sample ID: VCS-81535 Jenkinsville, S.C.

29065 Dat.e: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per:

IAW, ASTM A-449-84 Guidelines and Client's Instructions IOCEELL "B" TFSP RESULTS LEIS Ibte Average Corrected Piece !b.

Tested Peadinos Readino Reading Cgggnt 12-4-87-BB-III 12/4/87 26.9, 28.0, 28.3 27.7 28 Passed TINSION TEST REEULTS Diameter or Yield Yield Ultimate Ultimate Elongation Ptduction LEIS Date Width Thickness Area Ioad Stress Load Stress in ** Ins.

of Area Piece Ib.

Test _e_d (in_,)

(in.)

(ca. in.) (Ibs.)*

(psi. ) *

(Ibs.)

(psi.)

(%)

(%)

Cgrent

!DT RDQUIRED-BY GIINf

  • Offset =0.2t 00 Gage =

CIIEMICAL ANALYSIS TFSP RESULTSQL LEIS Date Piece Ib, Tested b

CaI on Fanganese Ph_osphorus Eb1 fur SiUcon Nickel Chromium Molytxlenum vaDgdlum_Aorpn Coment i

12-4-87-EI}-C1 12/17/87 0.35 0.83 0.01 0.01 Passed i

ll# f~

~

Respectfully submitted,

/

LAW ENGINEERING INDUSTRIAL SERVICES reviewed by:

/

'EdJard M. Deck Chief Engineer

[

Iarry E. CobIe, Metals Inboratory Supervisor

LAW ENGINEERING INDUSTRIAL SERVICES DIVISION OF LAW ENGINEERING,INC.

H3'+

501 MINUET LANE 1j/ -

P O BOX 11297

  • CHARLOTTE. NORTH CAROLINA 28220 (704)523-2022 Eh REIDIT OF MMERIAL VERFICATION TEST Client: SOlTI11 CAPDLINA ELECTRIC & GAS 00.

Client's P.O. Ib.: Q478707 Material: Peported as Item BB,1/2"-20 ULT, V.C. Summer Ibclear Station Office: Charlotte Metals A-563, Gr B, HH, CS Nut P.O. Box 88 Iab Ib.: CIIS2524 Pg 30 of 31 Sample ID: VCS-81546 Jenkinsville, S.C.

29065 Date: December 18, 1987 Date Tested: See Below Attn:

Ms. Kim Blough Tested Per: IAW, ASPM A-563-84 Guidelines and Client's Instructions IOChWEIL "B" TPSP RPRILTS LEIS Date Average Corrected Readjna Comment d

Piem tb.

Tegtsd Repdinos Readino 12-4-87-BD-H2 12/4/87 93.3, 93.5, 92.9 93.2 93 Pasrd TmSION TFSP RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area

_ Piece fb.

Te_sted (in,)

(in.)

(co, in.) (lbs. ) *

(psi. ) *

(]bs.)

(psi.)

(%)

(%)

Corrent IDT REQUIREn-BY GIMP

  • 0ffset=0.2%
    • Gage =

CIID1ICAL ANALYSIS TPSP RESATS(%)

LEIS Ihte Piece Ib.

Tg_st;_ed Cagbon Mancanese Phosphorus Sulfur __ Silicon Nickel Chromium MoJvbdenum vanadjum Poron Coment 12-4-87-ED-C2 12/17/87 0.07 0.02 0.01 Passed f

Respectfully submitted, y

LAW ENGINEERING INDUSTRIAL SERVICES Pcviewed by: /

Edaard M. Beck Chief Engineer Iarry E. Coble, Metals Iaboratory Supervisor

r LAW ENGINEERING INDUSTRIAL SERVICES q

DIVISION OF LAW ENGINEERING,INC.

1 Q;['L' o.

/!

(>

501 MINUET LANE P O f30X 11297

  • CHARLOTTE. NORTH CAROUNA 28220 fp Jh'i >

(70 t) 523-2022 REIDIT OF MMERIAL VLTFICATION TESP Clicnt: SOU'HI CAFDLINA ELECTRIC & GAS CD.

Client's P.O. No.: Q478707 Material: Reported as Item CC,1/2"-13 UNC, V.C. 92mmer tbclear Station Office: Charlotte Metals A-563, Gr B, liH, CS tbt P.O. Box 88 Iab tb.: GIS2524 Pg 31 of 31 Sarnple ID: VCS-81529 Jenkinsville, S.C.

29065 Date: Decenter 18, 1987 Date Tested: See Belm Attn:

Ms. Kim Blough Tested Per: IAW, ASIM A-563-84 Guidelines and Client's Instructions FOO W D L "B" TEST RFSlL_TS LEIS Date Average Corrected Piece Ib, Tested Readings Readim Readino Cqnrrent 12-4-874]C-H1 12/4/87 79.0, 84.8, 88.6 84.1 84 Passed TD7SION TEST RESULTS Diameter or Yield Yield Ultimate Ultimate Elongation Peduction LEIS Date Width Thickness Area Load Stress Load Stress in ** Ins.

of Area Piece Ib.

Tested (in.)

(in,)

(ca. _ in.) (Ibs. ) *

(psi. ) *

(Ibs.)

(psit.)

(%)

(%)

Cormnt fDT RICUIRED-BY CLIDE

  • 0f fret =0.2%

OCC3ge=

CITEMIC16 ANALYSIS TEST RESUL'IS(%)

LEIS Date

,P,lece Ib.

Te_st_e_d Car _ bon McDganese Phosphorus Stdfur Silftcon Nic};el Chromium FbJybdenum vadium Psion Comment 12-4-87-CC-Cl 12/17/87 0.11 0.02 0.02 Passed lI f

Respectfully submitted,

/ [f # 9

~

LAW ENGINEERING INDUSTRIAL SERVICES Eckard M. Ecck Chief Engineer

[

[

Larry E. Cobl(, Metals Laboratory Supervisor

ATTAC -lM E NT 11 OF ENC _OSURE V

)

i

l EVALUATION OF TEST RESULTS l

1 In order to comply with NRC Compliance Bulletin No. 87-02, a total of 31 samples of fasteners, representing both safety j

related and non-safety related

items, were tested by Law Engineering Industrial Services (LAW) to determine compliance with specification requirements for ultimate tensile strength, hardness, and chemistry.

The following evaluation of the test results concerns only those fasteners which did not meet the independent testing acceptance criteria as specified through the purchase order to Law Engineering Industrial Services.

SAMPLE VCS-81559/ Item I, ASTM A307 BOLT, 7/8"O, SAFETY RELATED There were two pieces (bolts) tested in sample Item I.

Piece number Il met chemistry requirements but did not meet the minimum hardnessc requirements.

Since Il did not meet the hardness requirements, piece number I2 was tested.

Piece number I2 met the chemistry, hardness, and tensile requirements and was therefore acceptable.

Piece I1 was not tested for tension in view of the test results for piece I2.

The minimum required Rockwell "B" hardness is 69 Piecs Il has a hardness of 66, which should actually be 68 (corrected) because ASTM E18 for Rockwell Hardness Testing indicates that a correction factor of

+2 RB points may be added for 7/8" dia.

specimens.

ASTM A307 Section 5.1 indicates that hardness test should govern for the maximum hardness requirement only, unless the colt is less than 3 diameters in length in which case the tension test cannot be run and the minimum hardness gives an indication of strength.

Since LAW did not perform a tension test on I1, minimum hardness requirements in accordance with ASTM A307 Section 5.4 could not be precluded.

Therefore, SCE&G selected a sample of remaining stock items for on-site hardness testing.

The sampling plan was based on MIL STD 105D.

The sample was tested in accordance with the arbitration method described in ASTM F606 which provides greater accuracy in the hardness reading.

Hardness readings for all bolts in the sample were well within the specified range.

Based on these results. _ _ _ _ _ _ _ _ _ _ _ _

the low hardness reading for Il is considered random; however, to gain further assurance, LAW has been requested to return the test specimens.

II will be retested using the ASTM F606 arbitration method.

SAMPLE VCS-81558/ Item K, and VCS-81565/ Item L. ASTM A325 Bolts, 7/8" O AND 1/2" O.

SAFETY RELATED Both of these samples (Item numbers K and L) meet hardness and tension requirements, but do not meet chemistry requirements for Type 2 bolts.

Both samples have high carbon content (0 39 and 0.40 versus a required range of 0.13 to 0 37 per ASTM A325-85) 1 and a low boron content (both less than 0.0005 versus a required minimum of 0.0005).

ASTM A325 Type I is a medium carbon steel (required carbon content range of 0.25 to 0.58).

Type 2 is a low carbon steel that has a boron addition (at least 0.0005) to achieve the hardenability that is obtained in Type 1 with carbon a

alone.

Since hardness and strength requirements are met, these l

bolts are considered acceptable.

Based on the wording in ASTM A325 Section - 1.2, Types 1 and 2 are virtually interchangeable.

Type 1 is actually preferred for high temperature applications.

Additionally, the more recent ASTM A325-86 requires a carbon content of 0.13 to 0.41 for Type a bolts, which would render these bolts acceptable.

4 SAMPLE VCS-81560/ Item N, ASTM A490 BOLT, 7/8" O, SAFETY RELATED i

i This sample (Item number N) meets tension and chemistry requirements, but does not meet minimum hardness requirements, I

having hardness values of RC 22 and RB 95, versus the required i

minimum of RC 33 and BHN 311, respectively.

In accordance with ASTM A490 Section 7.4, tension tests preclude hardness tests, acceptance is based on tensile requirements in the event hardness test results are low.

Therefore, this sample is acceptable.

SAMPLE VCS-81541/ Item T,

ASTM A574 CAP SCREW, 3/4" O_,

NON SAFETY RELATED t

This sample (Item number T) does not meet the minimum hardness I

requirement of Rc37 and was not required to be tested for tension.

This item was taken from non-safety stock items which l ;

were not procured to a specific ASTM standard.

ASTM standard A-574 was utilized as the testing standard because it most closely related to the item.

This is a non-safety item which would not have any effect on the safety related function of the plant.

SAMPLES VCS-81531/ Item W, VCS-81538/ Item X, and VCS-81539/ Item Z. ASTM F593 BOLT, 1/20, 3/4" 0 5/8"Q, NON SAFETY RELATED All of these samples (Item numbers W,

X, and Z) have a low sulfur content (0.01 versus 0.15 minimum required).

Since Grade 303 is an austenitic stainless steel to which sulfur is added to improve machinability, the low sulfur content should have no detrimental effects on the performance of the samples.

Two of the samples (Item numbers W and X) have slightly low nickel content (7.89 and 7.96 versus 8 to 10 required).

The check analysis limits for the 5.0 to 10.0 range of nickel content per ASTM A555 is 20.10.

ASTM E353 requirements for rounding off indicate one significant decimal place for nickel analysis in this chemistry range.

Therefore the following table applies for nickel content:

LAW TEST ROUND OFF CORRECT CORRECTED RESULT PER E353 PER A555 R ESULT Piece W 7.89 7.9

+0.1 8.0 Piece X 7.96 8.0

+0.1 8.1 Therefore, the nickel content is actually acceptable.

One of the samples (Item number X) has a hardness of 36, which is higher than the maximum allowable Rockwell C of 32 required by ASTM F593.

This item was taken from non-safety stock items which were not procured to a specific ASTM standard.

ASTM standard F593 was utilized as the testing standard because it most closely related to the item.

This is a non-safety item which would not have any effect on the safety related function of the plant.

3-

Enclosure VI to NRC Bulletin 87 02 January 12,1988 Page l of t ENCI.OSUllE VI ItEQUEST 6:

Hased on the results of the testing and review of current procedures, describe any further actions being taken to assure that fasteners used in the plant meet the requisite specifications and requirements and that the operability of safety related plant components is not affected.

Response

Due to the acceptability ofIhe test results, V. C. Summer Station concludes that the current program andprocedures are sufficient to assure that fasteners used in the plant meet the necessary requirements to perform their intended functions.