o
,)
h h
i Proposed Change No. 63 YANKEE ATOMIC ELECTRIC COMPANY y
441 STUART STREET, BOSTON MASSACHUSETTS 0216
[f April 11,1968 N
,sJr United States Atomic Energy Commission Washington, D. C.
205h5 y,
4 Attention: DLvision of Reactor Licensing
Reference:
License No. DPR-3 (Docket No. 50-29) f
Dear Sirs:
Parsuant to Section 50-29 of the Commission's Regulations, Yankee Atomic Electric Company hereby requests authorization to make the following change:
PROPOSED CHANGE:
Reference is made to Section 107 of the license application, Core Instrumentation. We propose to install up to four stationary stainless steel clad miniature fission chambers in flux wire paths that are presantly inoperable.
Number of detectors:
up to h Size:
0.090" or 0.072" diameter 2.25" sealed units Enrichment:
more than 90% in U235 Weight of fissionable material:
less than 2 mg per detector Reason for Change: Several paths, either due to tube damage or obstructions, are inoperable in the present flux wire system.
In an attempt to obtain response,and lifetime information on recently developed miniature, fission chambers, we propose to install up to'four of these detectors in the inoperable paths of the existing system. The detectors would be in a fixed position at approximately mid-core.
There is considerable interest to the nuclear industry in the information that could be generated from the installation of these detectors in an operating reactor. Future designs and installations could greatly be improved.
Safety Considerations: In our opinion, the proposed change does not present significant hazard considerations not described or implicit in the license application, as amended to August 2, 1967, the date of issuance of Amendment No. 52 to the License No. DPR-3 or as amended to th3 date hereof. @
801124,0
- q R
'yt V U. S.: Atomic Energy. Commission Proposed Change No. 83 Attn: Division of Reactor Licensing '
April 11, 196d The proposed change requires authorization by the Commission pur-suant to Section 50-29 of the Commission's Regulations, since it involves a change in the design specifications of the reactor which are set forth in the license application and incorporated by reference in the technical specifications (see paragraph B.2 of Appendix A to License No. IFR-3).
. Scheduling of Change: The change will be made during the present refueling currently on progress.
Respectfully submitX YANKEE ATOMIC ELEC'i UdPANY kA,vtAs L. E. Minnick Vice President Commonwealth of Massachusetts April 11,1968 Suffolk, ss Then personally appeared before me Lawrence E. Minnick, who, being duly sworn, did state that he is a Vice President of Yankee Atomic nectric Company, that he is duly authorized to execute and file the foregoing request in the name and on behalf of Yankee Atomic Hectric Company, and that the statements therein are true to the best of his knowledge and belief.
(
A Johry7. Mack hotary Public My 06mmission Expires Jan. 31, 1975 1
JI J$i / i Y.. 'f/
i 7'
n,:.
,. s',V..::
7.Ose W W /- /.., y y
/
' t'a'Y
/ U 7.' f o*
I
,/
)
?
"y-l1 Ma<sw7
,r.., e. :s-r2'arw;
': ll' OPc}/IN.'c (,ppgg-I,:
I i
f5 (:
f g. ie ' ' D.'A max
, s
/
W cs.v.vi.:. as I
5 t
. /* "
Rrnarog x
i
,[/ 5 * '.' &
l g
/
t
~ > <r. ; ent.er p. n I
s a
i i
e.
i l
O. 06 2 ',s;p.s nas I
(
i
\\
/. 4 %MA.', J.y
.i t
s'A N
F -
t'f(h px:,.vcp 7s Moff K&V.'
tipo45 f/2 5.c 78M4 /./ z.rss FW,4 A' f M,g/r>cr;r: To r e
- 0.0 90 n
- d. 072
~ !$
re: 1 u.n - r w s t,c
> (m e
i U..
s h
J 5,.
,, a. a e.I
[ ~'.
[O b
REACTOR DATA INPUT FORM Control #1314 A.
IDENTIFYING & LISCRIPTIVE DATA REACTORS I'
rdOGRAM li.PROJ.
03.DCCP ? No.
0 9. TA S K IO. TYPE OF REACTOR ll. CLASS OF RE AC TO R CCDE N o.
NO.
L sii so n
'* APPL l CANT 19.NAME OF REACTOR
TYPE UNIT REQUESTED DESIGN O AUTHORIZED 65 66 67
[68 2 4.C ITY
- 27. STATE 30.2tP ELEC.
{
69 70 71 W72 THER.
O n
- B.
A G O.s' DATA BASIC PROCESSING STAGES n
m A C T I V. C D.
74-Di T h P N.
FIRST ACTICN
/
N h]( Y SID.
PRE-APPLICATIQN Y "-
^*
31 l
CCNSID2RATICN
/,/
,,ff,ky'/
//,f', "-
"'Y g
APPLIC. REC.
f R
E 85 UL e.
Y R.
M O.
DAY PROSSSING APPLICA.
35
" '
- C ' '.'
j nNO FOR CONS'EUCTION h
co"
o^Tt STARTED
- PROY.
OP.
AUTHORITY ISSUED 38-Y lL M O.
DAY Qf $.
6 v. Y Rd M C.
O A Y-8 l.
- 22. Y R.
M O.
DAY EXPlRATION
{NN 36
[N o.
I P2CCSSING n
! CPE2ATING
~
cA TE sTiuTEa ruL TtAM AuT. issuto ALTHC2ITY pL
" ' * " c-o ^ Yn ' 6-
"Y"-
"o-o^*
l w
/ /
SUPPLE!.ZNTARY ACTION TASK N C.
Y R.
MC.
DAY e&
L87 Y R.
M O, DAY ISM E AS DATE SUPPLE.
bbb b
DATE SUPPLEMEh7ARY REDUEST 67 0[ 43 I
REOVEST REC *D.
43 m
15 0
<TAsa COMPLETED I
B At PvReOSE or RE0vE ST 4 T ASo gs4 RES - T or T A S x ( AM. N o.. C M A N c E N s. E T C.)
Ch heh Spses D
kh rp /70, b i
i C.
STATISTICS
" Tl
/
u.
4 a, g S i.
VolO INPUT ENTERED UNDER CODES IN T'.'PE 07 ACTION REQUESTED AND TAKEN REO.0Tu.
FI EL D S 01 03 OR 12 AND 09 AS I
p RECORDED ABOVE AND ACTIVITY A
- l. REACTOR CONCEPT REVIEW CODE n
f B
l PRELIMINARY SITE REVIEW p
l C
l P R E CO N STRuC TI ON STAGE REYlEW p
03*
l 3 CCNSTALCTION PERMtT(C.P. REVIEW) p CONSOLIDATE INPUT ENTERED UNDER E
l AUTHORITY 70 O PE R AT E (OP.ST AGE R EV IEw) p CODES IN FfELDS 01, 03 OR 12, Aho F
l AUTMCRITY TO POSSESS ONLY p
09 AS RECORDED ABOVE AND 0
! A V E h c M E P. T Tc C ON STR UCT ICN PERMIT n
ACTIVITY CODE wlTH h
AMENOVENT TO O P E R A T I P. G LlCENSE y
PROG.
PROJ.
l l
CHANCE TO TECHNICAL SPECIFICATIONS g]
TAh AU*
f J
l EFEMPTION 5
t K
I CCNETRUCTICN PERMIT EXTENSION O
h L
h C PE R AT IN G LICENSE (OR AUTHORITY) EXTENSION i
(
)
M l ORL ORDER h
k SPECIAL AUTMCRITY N
h T
l LICENSE (OR AUTMORITY) TERMINATED OR EXPl RED h
I
+
1 r
,r +_ais)
P l
O i
i D
l Y
-