Corrected Tech Spec Page 3/4 4-7 Re RCS Safety/Relief Valve Setpoints
ML20148J160
Person / Time
Site: River Bend 
Issue date: 03/22/1988
From:
GULF STATES UTILITIES CO.
To:
Shared Package
ML20148J153 List:
References
NUDOCS 8803300189
Download: ML20148J160 (1)


Text

r REACTOR COOLANT SYSTEM 3/4.4.2 SAFETY VALVES SAFETY / RELIEF VALVES LIMITING CONDITION FOR OPERATION 3.4.2.1 The safety valve function of at least 5 of the following valves and the relief valve function of at least 4 additional valves of the following valves, other than those satisfying the safety valve function requirement, shall be OPERA 8LE with the specified lift settings:

Number of Valves Function Setooint* (osic) 7 Safaty 1165 *-s- (+)0(-)21 5

Safaty 1180 N (+)0(-)25 4

Safety 1190 t-tN-(+)0(-)25 1

Reitef 1103 2 15 psig 8

Relief 1113

  • 15 psig 7

Relief 1123 2 15 psig The acoustic monitor for each OPE?*2LE valve shalf be OPERA 8LE.

APPLICABILITY: OPERATIONAL CONDITIONS 1, 2 and 3.

ACTION:

a.

With the safety and/or relief valve, function of one or more of the above required safety / relief valves inoperable, be in at least HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the next 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, b.

With one or more safety / relief valves stuck open, close the stuck open safety / relief valve (s); if suppression pool average water temperature is 105'F or great 6r, place the reactor mode switch in the Shutdown position.

c.

With one or more safety / relief valve acoustic monitors inoperable, restore the inoperable monitor (s) to OPERA 8LE status within 7 days or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

8803300189 880322 DR ADOCK 0500 8

"The lift setting pressure shall correspond to ambient conditions of the valves at nominal operating temperatures and pressures.

RIVER BEND - UNIT 1 3/4 4-7