September 27, 1978 I
Vicr Pet,ett=1
- C.C*a3*C.A*C4 'O' 3*3 4053
$9 tam penosction Mr. James P. O'Reilly, Director U. S."Nuc' lear Regulatory Commission Region II 101 Marietta Street, Suite 3100
'i Atlanta, Georgia 30303 Re:
RII:FJ 50-269/78-19 50-270/78-19 50-287/78-20
Dear Mr. O'Reilly:
I n regard to Mr. F /J. Long's letter of September 21, 1978 which transmitted IE Inspection Report 50-269/78-19, 50-270/78-19, 50-287/78-20, Duke Power Company does not consider the information to be proprietary.
Very truly yours, h 'y n,
~
[
William O. Parker, Jr.
RLG:ses p
i hhh
=
a 92 :lla 62d3S Ef 1
V f D t! O 3 0 ' Y." ' Y' ' Y ij, y.'
..,,.;i..--
x
- 9-6
' ' * ^
,y
,_,.._R, s,.
l
@ C800 UNITED STATES o
NUCLEAR REGULATORY COMMISSION g
R EGloN il s.
/ y
).p.
g
~ o E io1 MARIETTA STREET, N.W.
[
ATLANT A, GEORGIA 30303 o
%..v /
SEP 11 G78 In Reply Refer To:
RII:FJ 50-269/78-19 50-270/78-19 t
50-287/78-20 Duke Power Company Attn: Mr. William O. Parker, Jr.
Vice President, Steam Production i
P. O. Box 2178 i
422 South Church Street Charlotte, North Carolina 28242 Gentlemen:
This refers to the inspection conducted by Mr. F. Jape of this office on August 22-25, 1978 of activities authorized by NRC Operating License Nos.
DPR-38, DPR-47 and DPR-55 for the Oconee 1, 2 and 3 facilities, and to the discussion of our findings held with Mr. J. N. Pope at the conclusion of the inspection.
Areas examined during the inspection and our findings are discussed in the enclosed inspection report.
Within these areas, the inspection consisted-of selective examinations of procedures and representative records, inter-views with personnel, and observations by the inspecter.
Within the scope of this inspection, no items of noncompliance were dis-closed.
We have examined actions you have taken with regard to previously identi-fied enforcement matters.
These are discussed in the enclosed inspection report.
In accordance with Section 2.790 of the NRC's " Rules of Practice",.Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
If this report contains any information that you (or your contractor) believe to be proprietary, it is necessary that you make a written application within 20 days to this office to. withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is pro-prietary, and should.be prepared so that proprietary information identified in the application is contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room,
- S dup: 72/oNoN3 9
.=.:-..
.a-...-
/.,
n I
i 2
Duke Power Company SEP 211978
-i
,,Should you have any questions concerning this letter, we will be glad to j
. discuss them with you.
Sincerely, i,
F.J.Long,lhfief Reactor Operations and Nuclear Support Branch
Enclosure:
Inspection Report Nos.
50-269/78-19,50-270/78-19 and 50-287/78-20 cc: Mr. J. E. Smith, Station Manager Oconee Nuclear Plant P. O. Box 1175 Seneca, South Carolina 29678 t
e
+<-r-ei p
.-a
.m*
5 UNITED STATES y
o, NUCLEAR REGULATORY COMMISSION y
3 c ( [,g REGloN ll 101 M ARIETTA STREET, N.W.
g " ' - [E ATLANTA, GEORGIA 30303 o, p
%,......o*
.. Report Nos.:
50-269/78-19, 50-270/78-19 and 50-287/78-20 Docket Nos.:
50-269, 50-270 and 50-287 License Nos.: DPR-38, DPR-47 and DPR-55 Licensee: Duke Power Company P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 Facility Name: Oconee 1, 2 and 3 Inspection at: Oconee Nuclear Station Inspection conducted: August 22-25, 1978 Inspector:
F. Jape Reviewed by: [.6.
f//f/78 R. C. Lewis, Chief Date Reactor Projects Section No. 2 Reactor Operations and Nuclear Support Branch Inspection Su::: mary Inspection on August 22-25, 1978 (Report Nos. 50-269/78-19, 50-270/78-19 and 50-287/78-20)
Areas Inspected:
Routine, unannounced inspection to follevup on previous items of noncompliance; review of plant operations and review of safety limits, limiting safety system settings, and limiting conditions for operation.
The inspection involved 36 inspector-hours on site by one NRC inspector.
Results: Of the three areas inspected, no items of noncompliance or deviations were identified.
DUPLICATE DOCUMENT Entire document previously J
entered into system under:
{
nNo 981$l'f4/ W No. of pages:
O
.y
/A I
.)
/p.* *8 Gg#'o 9 *[
f'/
UNITED STATES e
NUCLEAR REGULATORY COMMISSION
,v
'g
[ 7b
['
REctON 11 g.
7 c
101 M ARIETT A STREET, N W
[
ATL ANT A. GEORGI A 30303 C"
o'y w-y NOV 0 51978 In Reply Refer To:
RII:WJM 50-269/78-17 50-270/78-17 50-287/78-18 l
Duke Power Company Attn: Mr. William O. Parker, Jr.
Vice President, Steam Production l
P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 i
i I
Gentlemerv l
J This refers to the inspection conducted by Mr. W. J. Millsap of this office j
on August 7, 1978, of activities authorized by h7C Operating License i
i Nos. DPR-38, DPR-47 and DPR-55 for the Oconee Nuclear Station 1, 2 and 3 4
/
facilities. The results of this inspection are discussed in our Inspection i
Report Nos 50-269/78-17, 50-270/78-17 and 50-287/78-18 which was enclosed j
with our letter to you dated September 20, 1978.
During the inspection members of your Oconee staf f measured the amount of j
radioactive material in an h7C phantom on the whole body counter.
This measurement was also made by other NRC licensees and three Department of Energy laboratcries.
The results of these measurements are given in the enclosures to this letter. gives the results of the measurements made by your staf f, the actual amount of each radionuclide present in the phantom at the time of this measurement, and the ratio of measured to actual amounts. Enclosure 2 gives the ratio of each measurement result to the amount actually present in the phantom at the time of the measurement for all measurements made by DOE laboratories and b'RC licensees.
Power reactor facility values are denoted by single letters; Department of Energy laboratory values are denoted by double letters. discusses general recommendations based on the inspector's observations of these measurements.
l
)
-78uzoom.L l
CCo i
i m,.
i
i a
1 a k
J l
Duke Power Company '
Should you have any questions concerning this letter, we will be glad to discuss them with you. No reply to this letter is required.
Sincerely, "k' lhi. tk <~
lJ. T. Sutherland, Chief Fuel Facility and Mater 2als Safety Branch
Enclosure:
As stated ec w/ encl:
Mr. J. E. Smith, Station Manager Oconee Nuclear Plant P. O. Box 1175 Seneca, South Carolina 29678 p
...q
.l r3 i
Facility:
Oconee Nuclear Station Facility Designation:
G Date of Measurement:
August 7, 1978 Measurement Ratio Result Actual (Measured / Actual) a.
Co-60 0.34 Ci 0.24 Ci 1.42 b.
Cs-137 0.21pCi 0.13 Ci 1,62 c.
Co-57 0.64 Ci 0.48pCi 1.33 i
d.
Cs-134 Not Repor'.cd 0.5bnCi l
j i
\\
/
l t
- a#m/.
~
1-j L
/.
1
~/
,1 1
t Ratios (Measured / Actual)
Facility Co-60 Cs-137 Co-57 Cs-134 1.
A*
1.29 1.62 0.07 NR 2.
B 1.08 1.92 1.22 NR 3.
C 1.42 1.31 0.66 NR 4.
D 1.46 0.85 NR**
NR 5.
E 2.04 2.77 NR NR 6.
F 1.25 0.85 1.22 NR 7.
G 1.42 1.62 1.33 NR 8.
H 0.88 1.62 0.63 43
.9.
I 1,63 2.38 0.23 NR 10.
J 2.42 2.62 NR NR 11.
AA 1.36 1.38 2.97 NR 12.
BB 0.78 0.92 0.67 NR 13.
CC 1.13 1.38 1.00 NR Facility A reported Cr-51 present in the amount of 0.10 pCi.
This was not present in the phantom.
NR - Not Reported, s _. -
.M g
ps 0
op-
~
v ww v
.w'.. $ -
-- 5. -
..~ru,..- m. m w nn,,,,, n:.
,s
- .._w.
s_
_.,,w m-
~
4 I',
.,7 W.
l
- x jj i
l t
t l
Observations'by the inspector during the course of all phantom measurements
.I suggest three general recommendations for the improvement of the whole body
)
counting programs.
I 1
i i
1.
The spectrum resulting f rom each whole body count should be observed in its entirety in order that the presence of unexpected radionuclides will be recognized. Several licensees failed to recognize the presence of the Cc-57 apparently because its gamma energy falls outside a predetermined region of interest, 2.
Each licensee-should determine the energy response (energy / channel) of his detector 'ouer the full range of the spectrum. Several licensees 1
had difficulty identifying.the Co-57 once the presence of a low energy emitter was recognized because of the unexpected response of the detectors at low energies.
3.
Each licensee should consider some-sort of intercomparison or independent. standard test of his whole body counter (s)..
A test of this-nature might reveal problems not immediately apparent to an individual group working independently of all others.
1 l
l i
'.+.s u
.Y
- - m, we w
e-a -,
6 - - - - -
g,,
y e
,,,w--.-p,,
m Y
.(/.
/
3.
A i
,u,J
- ds s' * * "
D t*K E PowE n COM P.O'T hd 4
Powen Stn;mtso
' ' ~
42 Socrn Cncaca Srazzi, Cruat,orte. R C. asza wi ww e =* =. c a.
a.
Septenber 27, 1973
<u a. c s. : c o c. c.. : c. u c. :.
273..:e2 s c.
=. a.,:,e.
Mr.. lames ?. O'Reilly, Director U. S. Nuclear Regulatory Co==ission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 l
Re:
R 1 :'a'JM 5 0 2 6 0 /?-:
[r50-270/78-17 50-287/78-o
Dear Mr. O'Reilly:
With regard to Mr. J. T. Sutherland's letter of Septe=ber 20, 1978 which transmitted IE Inspection Report 50-269/73-17, 50-270/78-17, 50-287/76-13, Duke Power Company does not consider the information to be proprietary.
Very truly yours, A:-:,,
i s
f b,,
s / C
'a'illiam O. Parker, J r.
RLG:ses i
n 4
f 77Iol3003h
- M L
/
view:3_e_ y2,i
_~
~
o UNITEo STATES
[f R8%qjo NUCLEAR REGULATORY COMMISSION g
, - e r[, a REGION 11 O'
%'hi"p!,$
g 101 M ARlETT A STREET, N.W.
fo, g
f ATLANTA. GEORGI A 30303
%.~.. e-p In Reply Refer To:
RII:WJM SEP 2 01978 50-269/78-17 50-270/78-17 50-287/78-18 Duke Power Company Atta:
Mr. William O. Parker, Jr.
Vice President, Steam Products.on P. O. Box 2178~
422 South Church Street Charlotte, North Carolina 28242 Gentlemen:
This refers to the inspection conducted by Mr. W. J. Millsap of this office on August 7, 1978, -' --tivities authorized by NRC Operating License Nos. DPR-38, DPR-4~
DPR-55 for the Oconee Nuclear Station Units 1, 2 and 3 facilities.
ad to the discussion of our findings held 1
with Mr. J. E. Smith-at the conclusion of the inspection.
Within the scope of this inspection, no items of noncompliance were disclosed.
Areas. examined during the inspection and our findings are discussed in the enclosed inspection report.
Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.
In accordance with Section 2.790 of the NRC'e " Rules of Practice",
Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
If-this report contains any information that you (or your contractor) believe to be proprietary, it is necessa y that you make a written application within 20 days to this office to withhold such information from public disclosure.
Any such application must include: a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained.in a separate part of the document.
If we do not hear f rom you.in this' regard within the specified period, the report will be placed in the Public Document Room.
3 d/O.l)oo6og tr
SEP 20'1979 Duke Power Company Should you have any questions concerning this letter, we will be glad to discuss them with you.
Sincerely, 7
/J. T. Sutherland, Chief Fuel Facility and Materials Safety Branch
Enclosure:
Inspection Report Nos.
50-269/78-17 50-270/78-17 50-287/78-18 cc w/ encl:
Mr. J. E. Smit.h, Station Manager Oconee Nuclear Plant P. O. Box 1175 Seneca, South Carolina 29678
UNITED STATES
/gD Q80 9'o, NUCLEAR REGULATORY COMMISSION 0
[
.g(
k AEGloN il 4
i 101 M ARIETT A STR EET, N.W.
5 o, pg
'[
ATLANTA, GE ORGI A 30303
%, ' w f
- ,,e Report Nos.:
50-269/78-17, 50-270/78-17 and 50-287/78 '3 Docket Nos.:
50-269, 50-270 and 50-287 i
J License Nos..
DPR-38, DPR-47 and DPR-55 Licensee:
Duke Power Company P. O. Box 33189 422 South Church Street Charlotte, North Carolina 2S242 j
Inspection at:
Oconee Nuclear Station Inspection conducted:
August 7, 1978 i
Inspector:
W. J. Millsa
/ j Reviewed by:
6 A. F. Gibsbn, Chief Date Radiation Support Section Fuel Facility and Materials Safety Branch Inspection Su=carv f
Inspection on August 7, 1978 (Report Nos. 50-269/78 17. 50-270/78-17 and 50-237/7$-13)
Area Inspected: \\ tole body counting practices and procedures, and a test count of the NRC phantom on the whole body counter.
The inspection involved 3 inspector-hours on site by one NRC inspector.
Results: