NSD-NRC-97-5033, Submits Formal Transmittal of Correspondence Previously Sent Informally Covering Period 970205-0316.Index of Encl Matl Attached

From kanterella
(Redirected from ML20147G446)
Jump to navigation Jump to search
Submits Formal Transmittal of Correspondence Previously Sent Informally Covering Period 970205-0316.Index of Encl Matl Attached
ML20147G446
Person / Time
Site: 05200003
Issue date: 03/21/1997
From: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Quay T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20147G451 List:
References
ACRS-GENERAL, NSD-NRC-97-5033, NUDOCS 9703280148
Download: ML20147G446 (5)


Text

..

4.'{g; 1

ec

e N

Westinghouse Energy Systems em 355 Electric Corporation Pittsburgh Pennsylvania 15230-0355 NSD-NRC-97-5033 DCP/NRC0780 Docket No.: STN-52-003 March 21,1997 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: T. R. QUAY SilBJECT:

INFORMAL CORRESPONDENCE

Dear Mr. Quay:

Please find enclosed a formal teanstr.ittal of correspondence we have previously sent to you informally. This informal correy cadence was sent over the period February 5,1997 through March 16,1997.

One informal correspondence from the NRC to Westinghouse is included in this package.

Attachment I provides the index of the attached material as you have requested.

A Brian A. McIntyre, Manager Advanced Plant Safety and Licensing jml Attachment Enclosure l

cc:

N. J. Liparulo, Westinghouse (w/o Attachment / Enclosure)

T. T. Martin, NRC (w/o Enclosure)

'b C00' I

e 1

I

_i rfjQQ]G

' ' ' ' ^

??2 22868: Zi388a u "

appuppppppa E

PDR

4 Attachment I to Westinghouse Letter DCP/NRC0780 l

DATE ADDRESSEE DESCRIPTION i

l 2/7/97 Huffman NOTRUMP & WC/T meeting proposed agendas j

2/14/97 Scaletti Request to provide def' itive action for Westinghouse, or to m

i make open item 172 action N i

l 2/17/97 Huffman Markup of SSAR section on cable mixing in trays. Will be in Revision 11 of the SSAR if we get your agreement. Will be in I

revision 12 otherwise.

2/18/97 Scaletti Request to provide definitive action for Westinghouse, or to make open item 177 action N

)

2/18/97 Sea,.J Request to provide definitive action for Westinghouse, or to j

make open items 710, 716, 717, 718, 719, 722, 724, 729, 730, i

731,732,2347,2348, 2349,3057 and 3247 action N 2/18/97 Throm Sample Revision to WCAP-14407, section 2 Tables 2-3 and 2-4 2/18/97 Sebrosky Markup of SSAR s'ection 6.2.4.2.3. Will be in SSAR revision 11 unless we hear otherwise.

2/18/97 Sebrosky/

Sandia squib failure rate information requested during 2/17/97 Huffman phone call. Action closed l

2/18/97 Kenyon SSAR Chapter 7 markup for revision 11 2/20/97 Scaletti Request to acknowledge receipt of information previously transmitted. Request to change status to action N or provide Westinghouse action.

2/20/97 Scaletti Open items for SSAR section 3.8.4. Request to provide definitive action for Westinghouse, or to make open items 740, 755, 757, 758 action N i

2/20/97 Scaletti Reminder list of open items where there is a difference in Westinghouse and NRC status. Request to change status to action N or provide Westinghouse action.

2/20/97 Quay Reminder list of open items where there is a difference in Westinghouse and NRC status. Request to change status to action N or provide Westinghouse action.

2/20/97 Scaletti Open items for SSAR section 3.8.5 2/20/97 Scaletti Open items 182. Request to provide definitive action for Westinghouse, or to change status.

2/20/97 Scaletti Open items 184. Request to provide definitive action for Westinghouse, or to change status.

3t!! A

l 2/14/97 Huffman WCAP-14171, Revision I discussion item closure 2/20/97 Scaletti/ Quay Open item closure status 2/21/97 Scaletti Open items for SSAR section 3.2 2/21/97 Jackson SSAR markup to address item 7.b.(5) of NRC letter of 10/17/96. Open item 266. Will go into SSAR revision 12

{

unless we hear otherwise 2/21/97 Huffman Next try at cable mixing. May need phone call.

2/21/97 Jackson SSAR markup to address open item 1172 from 2/20/97 phone i

call. Will go into revision 12 unless we hear otherwise.

i 2/21/97 Jackson SSAR markup to address item 7.a.(7) of NRC letter of 10/11/96. Open item 264. Will go into SSAR revision 12 unless we hear otherwise 2/21/97 Jackson SSAR markup to resolve item 239 from 11/5/96 phone call.

Will go into SSAR revision 12 unless we hear from you 2/24/97 Jackson SSAR markup to resolve new open item 11-5-3 from 11/5/96 phone call. Will go into SSAR revision 12 unless we hear from you 2/24/97 Sebrosky Change in hydrogen igniter information since August 13-14 1996 meeting. Assist in reviewing SSAR chapter 6.2.4 Revision 11.

2/7/97 Huffman WC/T LTC notes 2/25/97 Scaletti Open items for SSAR section 3.6.3. Request to provide definitive action for Westinghouse, or to make open items 1883,2430,2431,2432, and 3518 action N 2/26/97 Bongarra/

Changes to SSAR table 18.12.2-1 and SSAR section 7.4.3 that Higgins were discussed during 2/26/97 phone call. Will be included in SSAR revision 11 2/7/97 Huffman Agenda for 3/13 NOTRUMP meeting 2/28/97 Scaletti Open items for SSAR section 3.9, less 3.9.6. Request to provide definitive action for Westinghouse, or to make open items 782, 783, 786, 793,1792,1793,1797,1802,1807, and 3372 action N.

2/28/97 Scaletti Reminder list of open items where there is a difference in Westinghouse and NRC status. Request to change status to something other than action W or provide Westinghouse action.

2/28/97 Scaletti Open items for SSAR section 3.6. Request to provide definitive action for Westinghouse, or to make open items 801, 802, 805, 807, 809, 1716, 1727, 1730, 1731, 1736, 1740, 1742, 1745, 1747, 1753, 1760, 2066, 4998, 4999, 1005 and 5002 action N.

m

6, i

2/28/97 Scaletti Request to acknowledge receipt of information previously transmitted. Request to change status to action N or provide i

Westinghouse action.

2/28/97 Scaletti Open item status for SSAR section 3.12 2/28/97 Scaletti/ Quay Open item cloture status 2/27/97 Jackson SSAR markups to support 3/3 Westinghouse /NRC senior management meeting on structural issues 1

3/3/97 Kenyon Response to e-mailed question on RAI 471.26 3

2/25/97 Scaletti Open item 5 (RAI 410.263) Request to change status to action N, confirm N or provide Westinghouse action.

1 2/25/97 Jackson Open item 5 (RAI 410.263) Request to change status to action N, confirm N or provide Westinghouse action.

l 3/4/97 Scaletti Open item 142 (M 3.11-9). Second request to change status to l

action N or provide a definitive Westinghouse action.

3/4/97 Scaletti Open items for SSAR Chapter 11. Request to change status of l

open item 1172 to action N.

[l

}

3/4/97 Scaletti Open items for SSAR Chapter 4. Request to change status of 4

open item 854 to action N, closed or provide a definitive r

Westinghouse ac on.

2/28/97 Huffman/Lois Information to close WCOBRA/ TRAC CAD discussion items i

li(3),2a,12a,and 12b.

)

3/5/97 Scaletti Reminder list of open items where there is a difference in Westinghouse and NRC status. Request to change NRC status a

to something other than action W or provide Westinghouse action.

l 3/5/97 Scaletti Request to acknowledge receipt of information previously transmitted to close open items. Request to change status to j

action N or provide Westinghouse action.

3/5/97 Jackson Changes to fire zone SSAR markup i

3/7/97 Scaletti/ Quay Open item closure status 3/5/97 Huffman Sample road map to close open items, RAls for NOTRUMP V&V related issues to be discussed at 3/13 meeting 3/10/97 Sebrosky PRA markups to address open item 5015

)

3/10/97 Scaletti Open item 169. Request to provide definitive action for j

Westinghouse, or to change status to action N or closed.

I 3/10/97 Scaletti Open items for SSAR chapter 2. Request to change status of i

open item 556 to action N or closed.

I Si21 A

i g.

l 3/10/97 Huffman SSAR markups to close open item 153. Will be in SSAR revision 12 unless we hear otherwise. Request to change status to NRC status.

3/10/97 Scaletti Open items for LOFTRAN 3/10/97 Bongarra Draft human factors ITAAC 3/11/97 Scaletti Open item 172. Request to provide definitive action for Westinghouse, or to change status to action N.

3/11/97 Scaletti Open item 164. Third request to provide definitive action for Westinghouse, or to change status to action N.

3/11/97 Scaletti Open items for NOTRUMP Request to change status of open items 3144,3147,3148,3149,3150,3157,3158 and 3159 to action N or provide a definitive Westinghouse action.

3/11/97 Kenyon Draft SSAR section 7.6.2.3 in response to 3/10/97 phone call 3/6/97 Scaletti Open item 157. Second request to provide definitive action for Westinghouse, or to change status to action N.

j 3/12/97 Sebrosky/

SSAR markups for sections 6.3.2.1.2, 6.3.2.2.7.7 and I

Huffman 6.3.2.2.7.9. Will be included in SSAR revision 12 unless we hear otherwise.

3/12/97 Scaletti Open item 173. Request to provide definitive action for Westinghouse, or to change status to action N.

3/12/97 Scaletti Reminder list of open items where there is a difference in Westinghouse and NRC status. Request to change NRC status to something other than action W or provide Westinghouse action.

3/13/97 Kenyon Rewrite of open item 20, (RAI 471.23). Will be in SSAR revision 12 unless we hear otherwise.

3/13/97 Quay /Scaletti Open item closure status charts.

3/10/97 Landry NOTRUMP quench model 3/14/97 Scaletti Open item 182. Request to provide definitive action for Westinghouse, or to change status to action N.

3/14/97 Lcaletti Open item 405. Request to pmvide definitive action for Westinghouse, or to change status to action N or closed.

Request for NRC to acknowledge receipt of Westinghouse submittals by May 30,1997 to meet SECY-97-051 schedules.

3/10/97 Boehnart Draft agenda for 3/28/97 ACRS meeting 3/14/97 Kenyon Copies of letters from 3/13/97 closing, from a Westinghouse perspective, two open items from Chapter 12.

2/26/97 Winters AP600 OITS - Move 32 items to Action N 312tA