ML20147D610

From kanterella
Jump to navigation Jump to search
Forwards Rev 0 to LOCA Test of Moisture Dam Modified Rockbestos RS-6-104/LE Coaxial Cable,Abb/Ce Mineral Insulated Triaxial Cable & Conax Coxial Penetration Feedthroughs for Reg Guide 1.97 Hrrm Sys & LER 96-005-01
Date released: 06/09/2020 Download: ML20147D610


Rev 0 to LOCA Test of Moisture Dam Modified Rockbestos RSS-6-104/LE Coaxial Cable,Abb/Ce Mineral Insulated Triaxial Cable & Conax Coaxial Penetration Feedthroughs for Reg Guide 1.97 Hrrm Sys.
ML20147D635
Person / Time
Site: San Onofre 
Issue date: 11/15/1996
From: Nakamoto W, Stilwagen S, Trotta K
SOUTHERN CALIFORNIA EDISON CO.
To:
References
RTR-REGGD-01.097, RTR-REGGD-1.097
Download: ML20147D635 (220)
:on 960611,determined Moisture Could Permeate Cable Jacket & Cause Loss of Hrrm Signal.Caused Because Detector/Cable/Connector/Penetration Combination Was Not Tested to Ensure Combination Would Function.Issued TS
ML20147D627
Person / Time
Site: San Onofre 
Issue date: 02/07/1997
From: Krieger R
SOUTHERN CALIFORNIA EDISON CO.
To:
References
Download: ML20147D627 (3)
Forwards Revised LER 96-005-01 Which Discusses Occurrence Involving Environmental Qualification of Containment High Range Radiation Monitors
ML20147D620
Person / Time
Site: San Onofre 
Issue date: 02/07/1997
From: Krieger R
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20147D620 (1)
Forwards Rev 0 to LOCA Test of Moisture Dam Modified Rockbestos RS-6-104/LE Coaxial Cable,Abb/Ce Mineral Insulated Triaxial Cable & Conax Coxial Penetration Feedthroughs for Reg Guide 1.97 Hrrm Sys & LER 96-005-01
ML20147D605
Person / Time
Site: San Onofre 
Issue date: 02/10/1997
From: Gibson G
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-REGGD-01.097, RTR-REGGD-1.097
Download: ML20147D605 (2)