ML20142A100

From kanterella
Jump to navigation Jump to search
Corrected Amend 1 to License 50-21297-01 for State of Ak,Div of Geological & Geophysical Surveys,Amending License in Entirety
ML20142A100
Person / Time
Site: 03020475
(50-21297-01-A01, 50-21297-1-A1)
Issue date: 01/23/1986
From: Riedlinger B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML20142A101 List:
References
50-21297-01, 50-21297-1, NUDOCS 8603190311
Download: ML20142A100 (3)


See also: IR 05000212/1997001

Text

_

-


L--mm---g

yq

unc num veg

1

3

p

PAM

OF

PA m

(3 83)

U.S. NUCLEAR REGULATORY COMMISSloN

l

Amendment ho. 1

MATERIALS LICENSE

,

Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93 -438), and Title 10,

Code of' Federal Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations ;p

heretofore made by the IIcensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, ip

source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to p

deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable

license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is

i

subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any

lp

conditions specified below.

CORRECTED COPY

Ucensee

{U

In accordance with letter

b

dated December 13, 1985

lIj

1.

State of Alaska

3. Ucense number 50-21297-01 is amended in

Alaska Division of Geological

its entirety to read as followsip

and Geophysical Surveys

p

'

2-

Water Resources Section

? ,

4' Expiration date April 30, 1988

i

-~

I

P.O. Box 772116

.

Eagle River, Alaska 99577'f

S. Docket or

'

030-20475

,N

Reference No.

,

6. Byproduct, source, and/or

,h

7. Chemical and/or physical

8. Maximum amount that licensee

5

special nuclear material

form

-. may possess at any one time

E

(, -

-

' under this license

,.

,

A.

Cesium 137

U!

A'.'

. Sealed sources

'

A.

Not to exceed

E

'

,

[

'(New England Nuclear .

>5 millicurits

l

t

'

ModelNER-572)\\

r ~per source

p

g

!>

..

. _

_.

'

IB.

' Sealed!ncutron sources

B.

'Not to exceed

'p

B.

Americium 241

~

cy,

i.

(Numec' Hodel . AM-93),

3 curies

n

.

'

l',',

'per source

I

'

'

' *

'

s

,s

>

<

b,

9.

Authorized use

lg

s

1

-

,

s

'

'p

1<~

,

A. and B. For use in borehole and water we11 1ogging... .'

c,

l

' /

i

>

>

.

l

CONDITIONS

'

,,

>>

'

10. Licensed material may be used at the licensee's facilities location on Fish

y

Hatchery Read, Eagle River, Alaska and at' temporary job sites of the licensee.

jp

j,P

anywhere in the United States where the U. S. Nuclear Regulatory Commission

maintains jurisdiction for regulating the use of licensed material.

Ik

11. Licensed material shall be used by, or under the supervision and in the physical

Ip

presence of, Larry L. Dearborn or Roger D. A11ely,

p

5

12.

A.

The source (s) specified in Items 7. A. and 7.B. shall be tested for leakage

h

and/or contamination at intervals not to exceed 6 months. Any source

I

received from another person which is not accompanied by a certificate

ll

indicating that a test was performed within 6 months before the transfer

y

shall not be put into use until tested.

p

!p

>

B.

Any source in storage and not being used need not be tested. When the

source is ren.oved from storage for use or transfer to another person, it

j

shall be tested before use or transfer.

i

l

p

l

N

0603190311 860123

j,

REQ 5 LIC30

50-21297_-01 __

g,%- )

,

PDR

- - - - - = = = = = = m - - - - - ,,- - - - - - - - - - - - - - - - - - - - - - ,. . . ,,,- - - - -, - - - .).

_ _ _ _

.

.

.

.

.

.

.

.

.

.

wwwwwwumw.amrmummm mmmmum a n a m ww mm m A m m m m m m m m mmm m m mm mm mmm m mg

I

gorm 37.4A

U.S. NUCLEAR REGULATORY CoMMISSloN

2

3

jp

,

oy

p, cts

License number

I

l

50-21297-01

MATERIALS LICENSE

.

    • ' ' ' ' " " " "

'

SUPPLEMENTARY SHEET

S

030-20475

y

,

F

Amendment No. 1

l

h

>

l

CONDITIONS

$

(continued)

p

i

C.

The test shall be capable of detecting the presence of 0.005 microcurie of

lf

radioactive material on the test sample.

If the test reveals the presence

j

of 0.005 microcurie or more of removabic contamination, the source shall be

!,

removed from service and decontaminated, repaired, or disposed of in

Q

accordance with Commission regulations.. A report shall be filed within 5

j

days of the date the leak test result; is idiown,with the U. S. Nuclear

'p

Regulatory Commission, Region V; Nuclear Materials Safety and Safeguards

!b

~

Branch; 1450 Maria Lane,rSuite 210; Walnut Creek,-California 94596. The

E

j

report shall specify th'c source involved, the test results, and corrective

action taken. Records of leak test results shall be ke'pt in units of

p

microcuries and shall be maintained for inspection by the, Commission.

p

Records may be dispoted. of following Commission inspection.

if

,nf

,

.

o,

p

D.

The licensee ,is/ authorized i.o collect leak test Jsampics for.

ysis by

s

Eberline Instrument Company, or tes'ts for leakage and/or contamination

!

shallbeperformedbypersonsspecificallyllicensedbythefommissionoran

!

Agreement State to perform'such services.

-

,

'

j

7.

<

M

l-

t+

,

,

13.

Scaled sources containing licensed material lshall not be' opened'1

b,;

-?

s'

.

.

_

,

,

,

,

14. The licensee shall conduct a physical inventory every six'(6) months to account

I

for all sources and/or devices received'and' possessed under theflicense.

l

Records of the inventories shallibe maintained for:;two (2) ye'ars from the date

'

s-

b

'/! t

JO

of each inventory.

.

,

,

,

y

') , \\ )

i

15. The licensee may transport 111 censed material in accordance with the pre visions

}

of 10 CFR Part 71, " Packaging and Transportation qf Radioactive Material".

t

i

,

.

4

-

,

-

16. Except as specifically provided".otherwise in this license, the licensee shall

conduct its program in accordance with the' statements, representations, and

,

procedures contained in the documents including any enclosures, listed below.

i

The Nuclear Regulatory Commission's regulations shall govern unless the

i

s';atements, representations and procedures in the licensee's application and

correspondence are more restrictive than the regulations.

A. Application dated February 25, 1983

!.

p

B. Letter dated April 13, 1983

jh

C. Letter dated December 13, 1985

inil

'I

'II

'I

!I

lpf

,p

>

ssran- - -T s-r- - - - w

  1. - - - -w - w -g- - - -;, . . ., . . . . . . . - - - , w . . . . . . . 2

-

-

-

. - -

.


- . --- -- - -- - = = --- ---- = =-- - ._wayiramrarzwarmarmwaltwaramtsrsnz away

g.;Cgorm 34A

U.S. NUCLEAR REGULATORY COMMISSloN

3

PAGE

OF

PASE1 I

License number

N

50-21297-01

B

MATERIALS LICENSE

-Docket or Reference number

-

.i

.

l

SUPPLEMENTARY SHEET

030-20475

P

Amendment No. 1

p

>

N

l>b

CONDITIONS

p

(continued)

p

il

17.

Each source holder and logging tool containing radioactive material shall bear a

lI

legible and visible marking. The marking shall bear the conventional radiation

i

symbol and the following wording: IF FOUND - DANGER - RADIOACTIVE - DO NOT

i

IIANDLE - NOTIFY CIVIL AUTHORITIES.

'y

5

-

4

3

e~

, , ,

m

.

-

y : ,. f.

C~lq;,,

lg>

.

.

,

. J'

,

3,

ll

,

N>

1

t

<

i

!)

'-

.j

-

.,

lW

I

i

,

x

< Ji

ip

,W

..

,

'# )

p

..'

s-

-

'

\\ ,'

.

13

-

l

'

'-J

s

\\, ,

'

j

,

s

<

,

'

!

,

'

s

,'

t

,

i

e

,

-

(

.

,

l

I

,h

'

'

'

l

(
  1. /\\

"T:

'

j

'

<

, j jj

' "

'

'

f "'

j

E

j

,

1

-l

,

a,

,;.

i

s.

j

.

<

.

,s

'.

44

'

/ }. ;

,

t

l

' . -

j

,

..

s.

, L

'p

,;

, ,

,

,

)

't

'

,

,

,,

,

' c c'

,

>

'

-

l>P

<

'

i

,

' '

'

]

4

4

,

!

3D

<

FOR Tite U.S. NUCLEAR REGULATORY COMMISSION

jp

'

'

b

O

JAN 2 31986

4"

Date

By

b

]

Deth A. Riedlinger

y

j

llcalth Physicist (Licensing)

lp

j

Nuclear Materials Safety Section

'N

Region V

I

ll

>I

'

l

t

't

!'I

)s

,

!g

l

'

.I

!E.i

-.r................

....-..........a.......

......... 1

-- -


-----

- - -

-

-

- - - -

- --- - - -

-