ML20141J955

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-361/97-08 & 50-362/97-08 on 970421-25 & Nov.Insp Identified One Violation Re Failure to Adhere to Measures Established to Minimize welding-induced Sensitization of Steel
Date released: 06/03/2020 Download: ML20141J955


Insp Repts 50-361/97-08 & 50-362/97-08 on 970421-25. Violations Noted.Major Areas Inspected:Review of Licensee Implementation of Welding,Boric Acid Corrosion Prevention & ISI Programs
ML20141J989
Person / Time
Site: San Onofre 
Issue date: 05/23/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
References
Download: ML20141J989 (14)
Notice of Violation from Insp on 970421-25.Violation Noted: on 970423,inspectors Observed That Measures for Minimizing welding-induced Sensitization Were Not Implemented
ML20141J976
Person / Time
Site: San Onofre 
Issue date: 05/23/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
References
Download: ML20141J976 (2)
Forwards Insp Repts 50-361/97-08 & 50-362/97-08 on 970421-25 & Nov.Insp Identified One Violation Re Failure to Adhere to Measures Established to Minimize welding-induced Sensitization of Steel
ML20141J950
Person / Time
Site: San Onofre 
Issue date: 05/23/1997
From: Howell A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: RAY H B
SOUTHERN NUCLEAR OPERATING CO.
References
Download: ML20141J950 (5)