Text
~
.
.
-
.
.
U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION Docket No:
-50-73 License No:
R-33 u
Report No:
50-73/97-201
,
i Licensee:
General Electric Facility:
- General Electric Research Reactor l
i Location:
-Vallecitos, California Dates:-
June 5-6, 1997 Inspector:
Marvin M. Mendonca Senior Project Manager
Approved by:
Seymour H. Weiss, Acting Deputy Director Division of Reactor Program Management i
j l
9707230007 970717 PDR ADDCK 05<00(M173
'
G PENT
.
.
.
EXECUTIVE SUMMARY This routine, announced inspection consisted of the review of selected conditions and records since the last inspection, and related discussions with licensee personnel.
This inspcction was conducted in accordance with the guidance of NRC Inspection Manual. Activities were safely implemented as described in the report details and summarized in the following.
e Operational logs and records were acceptably maintained.
Events were acceptably identified and resolved by the licensee. Operations were in i
accordance with Technical Specifications (TS).
e Surveillances for startup were completed as required by TS.
Trending by the licensee provided timely evaluation of equipment performance.
- Procedures were effectively used by the operator.
Changes to procedures were acceptably reviewed, approved, and maintained.
e Requalification training and activities were focused on safety and were as required by the Requalification Plan.
- The changes to the organization met TS requirements. On-shift staffing and conduct of operations was acceptable.
- Review and audit functions and resolution of associated findings was as required.
The experimental review, approval and implementation program satisfied e
regulatory requirements.
- No fuel was handled or moved since the last inspection.
Maintenance activities were in accordance with approved procedures.
The design change was acceptably reviewed, approved, and implemented.
The radiation protection and environmental protection programs were e
conducted in accordance with required procedures, and requirements, e
No radioactive material was transported under the reactor license since the last inspection.
- The emergency plan was acceptably implemented.
- Security was in accordance with the approved security plans and material control and accountability was acceptable.
l-
l
-
.
.
.
l Report Details i
Summary of Facility Status During:the onsite-inspection period, the facility was shut down one day and was started up and operated several hours to allow for the conduct of various
'
radiographic work'on the other day.
J I.
Operations 01 Conduct of Operations 01.I' Operational Loos and Records a.
Inspection Scope (Insoection Procedure 69001)
The inspector reviewed operational logs and. record, seleu.ed events and research reactor operational parameters.
b.
Observations and Findinas Operational logs and records since the last inspection were prepared and maintained as required.-
Logs were clear and provided an acceptable description of operational activities.
Events were-first recorded in the console logbook. The essential event information was transferred to a startup and shutdown report J
which included the scram report.
The inspector reviewed Scram Report 97-01, a scram on April 28, 1997, that was due to operator error. Corrective actions for startup was as required by procedure and acceptable.
This process tracks completion of the corrective actions.
The inspector also verified, that selected operational parameters were in accordance with' Technical Specification Limiting Conditions of Operation, by observation of instrumentation and facility conditions during low power operations.
c.
Conclusions Operational logs and records were acceptably maintained.
Events
)
were acceptably identified and resolved by the licensee. Operations
were in accordance with Technical Specification Limiting Condition of_0peration requirements.
02 Operational Status of Facilities and Equipment
'
02.1 Surveillance and limitina Conditions of Operation a.
Inspection Scope (Inspection Procedure 69001)
The inspector reviewed surveillance procedures, and surveillance data.
1 m~-
. -,
-. -
-
-
e-
-
l
f.'
..
i-2-
b.
Observations and Findinas The inspector reviewed the settings 4 selected safety systems and-the conduct of safety system surveilla:ces during the research reactor precritical startup procedure, the procedure ~was of
,
acceptable detail, and was current and.up-to-date. The conduct of tthis procedure acceptably demonstrated compliance with Technical
{
Specification requirements (i.e. TS 4.1.3.1 or excess reactivity various daily scram channel checks:and TS 4.1.3.2 subcriticality i
with safety, rods withdrawn for reactor startup).
A~ practice of
trended drop and electronic times was noted by the inspector and aided the licensee in early identification and' evaluation of potential problem.
Similarly, trending'of nuclear instrument response was also used for early detection of instrument deterioration.
"
c.
Conclusions Surveillances required by Technical Specifications for startup were completed as required. Trending of data provided timely evaluation of equipment performance.
j 03 Operations Procedures and Documentation 03.1 Procedures a.
Inspection Scope (Inspection Procedure 69001)
The inspector reviewed administrative controls, operating procedures and. updates, and the performance of procedures.
b.
0bservations and Findinas The inspector verified that procedure 12.31 changed on March 5, 1997.
The change had been review and approved in accordance with-Technical Specifications and administration requirements.
The
'
change properly reflectedLin the-procedure copies in use at the control room.
The inspector observed that the conduct of startup and operations, as well as the setup for an experiment, was in accordance with current, approved procedures. Annual report was made in accordance with TS 6.5.1. and the Biennial review of selectea procedures was. verified to be. completed.
c.
Conclusions Procedures were effectively used by the operator.
Changes to procedures were acceptably reviewed, approved, and maintained.
i
..
.
- - - - - -
-. -. - -... -. - -.
.
- -
-... -
. - -.
.
i.
i
-
-
!
-3-
05. Operator Training and Qualification i
- 05.1 Reaualification Trainina
.'
a.
Inspection Scope (Inspection Procedure 69001)
'
The inspector reviewed active license status, training records,
i examinations.-
i
!
b.
Observations and Findinas
)
-.
,
{
Operator Requalification records were maintained.
Records and
'
!
discussions with operators showed that training was conducted on selected changes to the facility, procedures and events.
Records
,
also showed that active duty status and requalification plan.
requirements were maintained.
The licensee developed the operating and written exams for the.
current cycle..The inspector reviewed these exams and determined i
that they demonstrated acceptable content and questions.
!
Observations also verified compliance with TS 4.1.3.3 on neutron multiplication; The inspector also reviewed records for annual
.
control rod surveillance on drop times and electronics dropout times i
per TS 4.2.3.5.
Records showed these tests were acceptably
.i conducted in excess of TS requirement.
i-c.
Conclusions
Requalification training and activities were focused on research
!
reactor safety and were in accordance with the requirements.
!
l
Operations Organization and Administration n
06.1 Oraanization and Staffina
'
a.
Insoection Scone (Insoection Procedure 690011
.L The inspector reviewed the organization and staffing.
b.
Observations and Findinas
!
The inspector reviewed changes in the organization. The changes i
were administrative in nature and consistent with Technical Specification requirements,
f The number of licensed operators remained unchanged. All operators were SR0s.
Two SR0s were at the facility during operations.
The
'
staff size and supervisory oversight were acceptable to support the i
research reactor utilization schedule.
These observations verified that the requirements of Technical Specifications were being
,
satisfied by the licensee.
"
--
. __
-
-
.
-
.
..
._ _ _. _ _. _ _. _ _ _ _ _.
_. _ _ _ _. _ _. _.
_.. _. _... _ _. _ _. _
L,
-
, -.
.
.
!
'
!
-4-r c.
Conclusions
-]
.
The changes.to-the organization were acceptable. On-shift staffing
'!
and conduct of operations met the requirements.
j 07 Quality Assurance in Operations
-
07.1 Committees. Audits-and Reviews'
s
~
Icsoection Scone (Inspection Procedure 69001)
a.
i
.
[
The inspector reviewed committee membership, meeting minutes, and H
i.
'the results of audits and reviews.
[
b.
Observations and Findinas
!
The inspector discussed review: processes and communications of i
issues with the Manager of Regulatory Compliance..The inspector i
reviews the Committee activities related to the last two reactor
scrams. These reviews, records, and discussions-showed that the
'
committee was effectively reviewing and evaluation issues, j
The inspector reviewed the most recent audits.
The inspector found j
the audits addressed issues of organization.and nuclear material control, to determine compliance to requirements.
4-
.
With regard to the resolution of review and audit findings by the
,
. licensee, the inspector waf presented with a process that addressed i
each related issue. The in:,ector verified that the licensee had completed action on selectec review and audit issues, c.
Conclusions i
i Committee review and audit fun:tions were'as required by the l
Technical Specifications, and issociated license resolution i
activities were completed.
08 Miscellaneous Operations Issues
08.1 Experiments
,
a.. Inspection Scope (Inspection Procedure 69001)
The inspector reviewed experiment review and authorization' records.
b.
Observations and Findinas The radiogryhic experiment of exposure materials authorization form was reviewed and approved by the licensee in accordance with Technical Specifications.
The review provided an acceptable safety
.-
. -..
._
.
- -
-
l
-
.
.
.
l-5-
!
analysis of the experiment.
The review also addressed potential hazards, reactivity and radiation levels, and experimental operational requirements.
Implementation of experimental protection o
l features for the amount of exposures, were observed by the l
inspector.
c.
Conclusions l
The experimental review, approval and implementation program met regulatory requirements.
i 08.2 Fuel Handlina Loas and Record a.
Scope (Inspection Procedure 69001)
l The inspector reviewed fuel handling records.
b.
Observations and Findinos No fuel handling was conducted since the last inspection.
c.
Conclusions No fuel handling activities were conducted since the last
,
,
'
inspection.
II. Maintenance M1 Conduct of Maintenance M1.1 Maintenance Loos and Records a.
Inspection Scope (Inspection Procedure 69001)
The inspector reviewed maintenance review and approval records, maintenance procedures, and maintenance authorizations.
b.
Observations and Findings The licensee repaired a Remote Area Monitor (#5) on May 12, 1997.
The replacement part was acceptable as demonstrated by test and calibration.
The maintenance was acceptably documented and tracked from operator log through maintenance record and procedure. Within l
the scope of this review, no safety concerns were identified.
l
[
,
l
-
.
.
_ _ _
_
. - _
. _ - _. - -
m.
...
.
._
-
l
-
.
,
l-6-(
c.
Conclusions i
l Research reactor maintenance activities were documented and
'
performed in accordance with approved procedures.
III.
Enaineerina l
El Conduct of Engineering
-
El.1 Desian Chances j
a.
Insoection Scope (Inspection Procedure 69001)
The inspector reviewed a change package authorization, and
'
associated procedures and drawings.
b.
Observations and Findinas.
I A change for the new setup room was reviewed and approved by the license in accordance with the requirements of 10 CFR 50.59 and licensee administrative procedures.
The changa was consistent with safety analysis assumptions.
Procedure end drawing changes were documented and were consistent with the changes as observed by the inspector.
c.
Conclusions The design change was acceptably reviewed, approved, and implamented.
IV. Elant Support R1 Radiation Protection and Chemistry Control RI.1 Health Physics a.
Scope (Inspection Procedure 69001)
The inspector reviewed rad protection program and record.
l b.
Observations and Findinas
,
L The inspector observed entry by site personnel into a radiation area.. Postings were as required and were followed by personnel.
Dosimetry was as required.
Exposure records were complete, as well as, environmental monitoring record.
These records were done by a NVLAP accredited lab.
Results were consistent with annual report value.
,
.
-7-c.
Conclusions The radiation protection program was conducted as required by site
, wide and facility procedures, and requirements.
R8 Miscellaneous Radiation Protection and Control Issue R8.1 Transportation a.
Scope (Inspection Procedure 86740)
The inspector reviewed facility records for transportation of radioactive material.
b.
Observations of Findinas The inspector reviewed the licensees process for ensuring the decay of radioactive material to below allowable levels f ar transportation.
c.
Conclusions There was no transportation of radioactive materials.
P1 Conduct of Emergency Preparedness Activities Pl.1 Emergency Planning a.
Scope (Inspection Procedure 69001)
The inspector reviewed the emergency plan, and emergency facilities, equipment, and supplies, exercises and drills, and training, b.
Observations and Ffndinas The Emergency Plan _ and implementing procedures were kept up to date and copies were readily available in response locations. The inspector verified that emergency call lists were accurate and readily available.
Exercises and drills, were in accordance with Emergency Plan requirements.
Licensee key emergency response personnel demonstrated that they could respond to emergency situations as required. Offsite response agencies communications verifications were as required by the Emergency Plan.
Facilities, equipment and supplies were maintained as required by the Emergency Plan.
c.
Conclusions The emergency plan was acceptably implemente._
_
_.
_ _ _ -.
_... _.
...
_.,..
. _..
_. _ _ _.
. _. _. __
'-
l
-
.
!..
L-8-51 Conduct of Security and Safeguards Activities
_
l Sl.1 Security and Safeguards a.
Scope (Inspection Procedures 81401, 81402, 81431, 81810.. and 851021'
'
The inspector reviewed the physical security and safeguards programs.
b.
Observation and Findinas i
The security plan was maintained as required.
There were no i
reportable events per 10 CFR 73.71 or. Appendix G.
Physical l
protection was as required by the security plan. Material accountability forms were completed and filed as required.
Information was maintained as required.
.c.
Conclusions
.The security and safeguards program implementation was acceptable.
V.
Mannaemant Meetinas XI. Exit Meeting Summary.
The inspector. presented the inspection results to members of licensee management at the conclusion of the inspection on June'6, 1997.
The licensee acknowledged the findings presented.
,
l
!
!
-.-
-
- -.
.
.
-
. -
.. - - - - _. - - -..
-.... -.
- -..
,
-
...
.
.
PARTIAL LIST OF PERSONS CONTACTED Licensee
-
William E. Kreutel, Senior Reactor Operator (SRO) & Acting Manager /NTR Gary Stimmell, Manager Vallecitos and Morris Operations Ben Murray, Sr. Licensing Engineer Chuck Bassett, Manager, Regulatory Compliance Fred Arlt, Manager, Facilities Maintenance j
Ron R. Snyder, SR0 Mike Rogers, Specialist, Radiation Monitoring
ITEMS OPENE0,' CLOSED, AND DISCUSSED
.
Opened None
'
Elslad
None I
i i
,
)