ML20141F024

From kanterella
Jump to navigation Jump to search
Addendum to Zion Station 1996 Radiological Environ Operating Rept
ML20141F024
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 12/31/1996
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20141F012 List:
References
NUDOCS 9705210185
Download: ML20141F024 (41)


Text

.;

ZION

1.0 INTRODUCTION

'Ihe following constitutes the current,1996 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Zion Nuclear Power Station, Zion, Illinois. Results of completed analyses are presented in the. attached tables. Missing entries indicate analyses that are not completed and the results will appear in subsequent reports.

Missing tables indicate sample media scheduled for collection at a future date. Tables will appear in subsequent reports.

. Data obtained in the program are well within the ranges previously encountered in the program and to be expected in the environmental media sampled.

For all gamma isotopic analyses, spectrum is computer scanned from 80 to 2048 kev. Specifically included are Mn-54, Fe-59, Co-58, Co-60,2n-65, Zr-95, Nb-95, Ru 103, Ru-106,1131, Ba-La 140, Cs-134, Cs-137, Ce-141, and Ce-144. Naturally occurring gamma-emitters, such as K-40 and Ra daughters, are frequently detected but not listed here. The data is reported in the format of xt2s;2TPU, where "x" is the significant result, "s" is the one standard deviation counting uncertainty, and TPU is the total propagated uncertainty at the one sigma confidence level.

Locations denoted by a "(C)" after site code refer to control locations.

All concentrations, except gross alpha and beta, are decay corrected to the time of collection.

TLD data is provided by Commonwealth Edison Company.

Deviatinns from Scheduled Sampling and Corrective Actions Taken All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.

Unusual Environmental Mansurements L cation Collection Sample Type Comments Code Date 9705210185 970513 PDR ADOCK 05000295 R,

PDR

.a

'iv

ZION 2.0 STATION ACTION ITEMS 4

i Initial Notification

. Item Problem Recommended Solution (Month / Year)

None 12/96 h

i 9

i 7

e i

b 4

f I

e i

5

'h I

.V

ZION s.

2' 3.0 LISTING OF MISSED SAMPIF4 C

l h ec W P

Location Collection Reason Sample Type g

Date TLD Z-216-2 04 %

Missing from location; installed new TLD.

l CW Z-23N 10-10 Sample not at guard house for pick-up; station Point of Contact notified. Point of Contact.

informed Teledyne sample was unavailable due to j

construction in the collection area.

r 1'

i-t b'

f

.I r

I t

t I

h 4

1 i

a i

i i

j vi I

i

~

w r.

9 ZION

)

4.0 LISTING OF SAMPLE ANOMALIES

-l i

L cation Collection Sample Type Reason Code Date

' A/1 2-01 02 %

Volume low; no electricity.

f A.

Z-01 02-24-96 Pump malfunction and failure; installed j

i.

replacement pump.

j A

Z 01 03 %

Volume low; filter light; power loss suspected.

TLD Z-01-1.

03-23-96

'llD found on ground; reh talled TLD.

1 A.

Z-01 04-20-96 Volume low; no electricity.

i

- A/l.

Z-01 05-25-96 Volume low; filter light; power loss suspected.

'{

e i

f I

f I

i k

a s

t r

e i.

i i

6 I

I

. ygg.

4

ZION Table 1.

Airborne Particulates and Iodine I 131 Collection:

Airbome Particulates - Continuous; weekly exchange Iodine Cartridges - Continuous; biweekly exchange Required I LD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I 131 Units:

10 pCi/m' Z-01. Onsite No.1, Southside Date Volume Gross Date Volume Gross Collected (m')

Beta I-131' Collected (m')

Beta I-131*

01 07-96 280 1.810.3;0.4 0.110.6;0.6 07-06-96 281 1.7 0.3; 0.4

-0.6 1.0;1.0 07-13-96 284 1.6 0.3; 0.4 01-13-96 246 2.4 0.4; 0.6 01 20-96 284 1.510.3;0.4

-0.6 i 0.9;0.9 07-20-96 279 1.6 i 0.3; 0.4 0.1 i 0.8;0.8 07-27-96 287 1.6 0.3; 0.4 01-27-96 284 2.610.3;0.6 02-03-96 288 2.8 i 0.3; 0.6 0.2 i 0.7;0.7 08-03-96 293 1.210.3;0.3 0.3 0.5;0.5 02-10-96 284 1.0 i 0.3; 0.3 08-10-96 280 2.010.3;0.5 02-17-96 190' O.7 i 0.4; 0.4 0.210.5;0.5 08-17-96 285 2.1 0.3; 0.5

-0.2 0.5;0.5 08-24-96 285 2.4 0.3; 0.5 02-24 96 N S' 03-02-96 285 2.010.3;0.5

-0.3 i 0.8;0.8 08 31-96 290 1.7 0.3; 0.4 0.4 0.7;0.7 d

09-07-96 280 4.2 0.4 : 0.9 03-09-96 252 2.010.3;0.5 03-16-96 287 2.310.3;0.5

-0.4 i 0.7;0.7 09-14-96 287 2.0 0.3; 0.5

-0.3 0.7;0.7 03-23-96 279 4.3 i 0.4; d.9 09-21-96 283 1.8 0.3; 0.4 03-30-96 288 2.4 i 0.3; 0.5 0.310.7;0.7 09-29-96 332 2.3 0.3; 0.5

-0.510.7;0.7 1st Qtr. Meants.d. 2.20.9

-0.110.4 3rd Qtr. Meants.d. 2.00.7

-0.10.4 04-07-96 320 1.910.3;0.4 10-05-96 241 2.2 0.4 ; 0.5 04-13-96 244 1.710.3;0.5

-0.510.6;0.6 10-13-96 327 1.810.3;0.4

-0.3 0.7;0.7 6

10-19-96 246 2.6 0.4; 0.6 04 20-96 266 1.5 0.3;0.4 04 28-96 305 1.5 i 0.3; 0.4 0.110.6;0.6 10-26-96 291 2.0 0.3; 0.5

-0.2 0.9; 0.9 11-02-96 277 2.4 i 0.3; 0.5 05-04-96 253 1.8 i 0.3; 0.5 05 12-96 321 1.210.2;0.3 0.310.5;0.5 11-10-96 328 2.110.3;0.5

-0.010.6;0.6 05-18-96 244 1.610.3;0.4 11-16-96 245 1.7 0.3; 0.4 05-25-96 253 1.7 i 0.3; 0.4

-0.310.4;0.4 11-23-96 287 2.1 0.3; 0.5

-0.2 0.7;0.7 d

12-01-96 328 2.6 0.3; 0.6 06-01-96 286 1.610.3;0.4 06-08-96 284 1.310.3;0.4 0.610.6;0.6 12-07 96 244 3.1 0.4 ; 0.7

-0.5 0.8;0.8 12-15-96 317 2.510.3;0.5 06-15-96 287 0.9 t 0.3; 0.3 06-22-96 277 1.3 i 0.3; 0.4 0.5 i 0.7;0.7 12-21-96 248 3.6 0.4 ; 0.8

-0.3 0.8;0.8 12-28-96 296 2.1 i 0.3; 0.5 06-29-96 295 1.6 i 0.3; 0.4 2nd Qtr. Mean s.d.

1.5i0.3 0.110.4 4th Qtr. Meanis.d. 2.40.5

-0.310.2 Volume based on a two week collection period.

  • Volume low; no electricity.
  • NS = No Sample; pump malfunction and failure; installed replacement pump.

d Volume low; filter light; power loss suspected.

' 1 -1

_m.-.

ZION Table 1.

Airborne Particulates and Iodine I-131 Collection:

Airbome Particulates - Continuous; weekly exchange i

Iodine Cartridges - Continuous; biweekly exchange Required LLD. 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for 1-131 Units:

10 2 pCi/m' 2

Z-02 Onsite No. 2, Westside j

Date Volume Gross Date Volume Gross l

Collected (m')

Beta I-131' Collected (m')

Beta 1-131'

{

i 01-07-96 280 2.I 'i 0.3; 0.5

-0.2 i 0.5;0.5 07 %

281 1.7 i 0.3; 0.4

-0.1 i 0.4;0.4 07-13-96 289 L710.3; 0.4 01 13-96 246 < 2.410.4 0.6 01 20-96 284 1.7 i 0.3; 0.4 0.3 i 0.7;0.7 07-20 96 279 1.710.3;0.4

-0.210.7;0.7 01-27 96 284 1.6 t 0.3; 0.4 07 %

287 1.2 i 0.2; 0.3 02 03-96 ' 288 2.0 i 0.3; 0.5 0.2i 0.5;0.5 08-03-96 293 1.2 i 0.3 ; 0.3

-0.6 i 0.6;0.6

}

08-10-96 280 1.8 i 0.3; 0.4 02 %

284 2.8 i 0.3; 0.6 i

02-17-96 284 1.7 i 0.3; 0.4

-0.210.9;0.9 08-17-96 285 1.7 i 0.3; 0.4

-0.0 i 0.5;0.5 02-24-96 288 1.3 i 0.3; 0.3 08-24-96 285 2.4 1 0.3; 0.5 03-02-96 285 1.5 i 0.3; 0.4

-0.410.7;0.7 08-31-96 290- 2.0 i 0.3; 0.5

-0.4 i 0.8;0.8 09-07-96 280 4.0 i 0.4; 0.8 03 09-96 292 1.9 i 0.3; 0.5 03-16-96 287 2.6 i 0.3; 0.6

-0.5 i 0.6;0.6 09-14-96 287 2.210.3;0.5

-0.110.7;0.7 09-21-96 285 1.9 i 0.3; 0.5 03-23-96 280 2.1 i 0.3; 0.5 F

03-30 96 287 2.2 i 0.3; 0.5 0.6i0.7;0.7 09-29-96 331 2.1 i 0.3: 0.5 0.1 i 0.7;0.7 1st Qtr. Meants.d. 2.0i0.4

-0.010.4 3rd Qtr. Meants.d. 2.0i0.7

-0.20.2 10-05-96 241 2.610.4;0.6 04-07 96 320 1.910.3;0.4 04-13-96 249 1.6 i 0.3; 0.4 0.0i 0.3;0.3 10-13-96 327 1.8 i 0.3; 0.4 0.3 i 0.7;0.7 10-19-96 246 2.4 i 0.4; 0.6 04 20-96 286 1 43.3;0.4 04-28-96 320 1.5 i 0.3; 0.4 0.3 i 0.5;0.5 10 %

292 2.1 i 0.3; 0.5 0.6i0.80.8 11-02-96 278 2.2 i 0.3; 0.5 05-04 96. 253 1.6 i 0.3; 0.4 05-12-96 '321-1.2 i 0.2;0.3 0.210.4;0.4 11 10-96 328 2.1 i 0.3; 0.5

-0.3 0.6;0.6 11 %

245 1.5 t 0.3; 0.4 05-18-96 244 1.7 i 0.3; 0.5 05-25-96 287 1.4 i 0.3; 0.4 0.210.7;0.7 11 23-96 287 1.8 i 0.3; 0.4 0.1 0.7;0.7 12-01 96 328 2.310.3;0.5 06-01-96 286 1.5 i 0.3; 0.4 06-08-96 284 0.910.2;0.3

-0.710.6;0.6 12-07-96 244 3.0 t 0.4; 0.7 0.4 0.8;0.8

)

12-15-96 317 2.4 i 0.3; 0.5 06-15-96 287 1.4 i 0.3; 0.4 06 % 284 1.5

  • 0.3;0.4

-0.210.8;0.8 12-21-96 248 3.0 t 0.4; 0.7 0.4 i 0.6;0.6 12-28-96 2%

2.3 i 0.3; 0.5 06 % 295 1.5103;0.4 2nd Qtr. Meanis.d. 1.510.2

-0.010.4 4th Qtr. Meants.d. 2.310.5 0.210.3

  • Volume based on a two week collection period.

s l

1 2'

ZION Table 1.

Airborne Particulates and Iodine I-131 Collection:

Airborne Particulates - Continuous; weekly exchange Iodine Cartridges - Continuous; biweekly exchange Required LLD. 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units:

10'* pCi/m' Z-03.Onsite No. 3, Northside Date Volume Grms Date Volume Gross Collected (m )

Beta I-131' Collected (m')

Beta I 131' 2

01-07-96 280 2.5 i 0.3; 0.6 0.010.3;0.3 07-06-96 282 2.1 0.3; 0.5

-0.3 0.9;0.9 01-13-96 246 2.9 0.4 ; 0.6 07-13-96 280 1.5 0.3; 0.4 01-20-96 284 2.0 i 0.3; 0.5

-0.410.8;0.8 07-20-96 279 1.6 0.3; 0.4

-0.410.7;0.7 07-27-96 287 1.4 i 0.3 ; 0.4 01 27-96 284 2.6 0.3; 0.6 02-03-96 288 3.0 t 0.4; 0.6

-0.1 i 0.6;0.6 08-03-96 293 1.3 i 0.3; 0.4 0.1 0.5;0.5 08-10-96 280 1.8 0.3; 0.4 02-10-96 283 2.010.3;0.5 02-17-96 284 1.110.3;0.3 0.010.4;0.4 08-17-96 285 1.610.3;0.4 0.1 i 1.0; 1.0 08-24-96 285 2.1 0.3 ; 0.5 02-24-96 288 1.810.3;0.4 03-02-96 285 1.8 i 0.3; 0.4

-0.6 i 0.7;0.7 08-31-96 290 1.7 i 0.3; 0.4

-0.1 1.0; 1.0 09-07-96 280 3.8 0.4 ; 0.8 03-09-96 293 2.2 i 0.3; 0.5 03 16-96 286 2.510.3;0.5

-0.3 i 0.8; 0.8 09-14-96 286 2.1 i 0.3; 0.5

-0.010.7;0.7 09-21-96 287 1.5 0.3; 0.4 03-23-96 280 1.7 i 0.3; 0.4 03-30-96 286 2.0 0.3; 0.4 0.5 i 0.7;0.7 09-29-96 330 2.3 0.3;0.5

-0.4 i 0.7; 0.7 1st Qtr. Meants.d. 2.110.5

-0.1 0.3 3rd Qtr. Meants.d. 1.910.7

-0.20.2 10-05-96 241 2.210.4;0.5 04-07-96 321 1.710.3;0.4 04-13-96 243 1.7 i 0.3; 0.5

-0.010.3;0.3 10-13-96 327 2.0 0.3; 0.5

-0.210.8 t

04-20-96 287 0.810.2;0.3 10-19-96 246 2.510.4;0.6 04-28-96 320 1.5 i 0.3; 0.4 0.510.5;0.5 10-26-96 293 2.6 i 0.3; 0.6 0.5 0.7 ; 0.,

05-04-96 253 1.6 i 0.3; 0.4 11-02-96 277 2.1 i 0.3; 0.5 05-12-96 321 1.2 0.2; 0.3 0.310.5;0.5 11-10-96 328 2.010.3;0.5

-0.5 0.6;0.6 11-16-96 245 1.7 i 0.3; 0.4 05-18-96 244 1.610.3;0.4 05-25-96 287 1.610.3;0.4

-0.1 0.4 ;0.4 11-23-96 288 2.0 0.3; 0.5 0.7 0.8; 0.8 j

12-01-96 328 2.7 0.3; 0.6 06-01-96 286 1.2 i 0.3; 0.3 06-08 96 284 1.1 i 0.3; 0.3

-0.410.7;0.8 12-07-96 244 2.7 i 0.4 ; 0.6 0.010.8;0.8 06-15-96 287 1.310.3;0.4 12-15-96 317 2.510.3;0.5 06-22-96 281 1.510.3;0.4

-0.010.7;0.7 12-21-96 248 3.210.4;0.7

-0.6 0.6;0.6 06 29-96 294 1.7 i 0.3; 0.4 12-28-96 296 2.2 0.3; 0.5 2nd Qtr. Meants.d. 1.40.3 0.010.3 4th Qtr. Meanis.d. 2.310.4

-0.00.5 l

1

  • Volume based on a two week collection period.

1-3 j

ZION Table 1.

Airborne Particulates and lodine 1131 Collection:

Airbome Particulates Continuous; weekly exchange

(-

Iodine Cartridges - Continuous; biweekly exchange Required LLD: 0.01 pCi/m' for Gross Seta and 0.07 pCi/m' for I-131 Units:

10 pCi/m' Z-06 Zion (WNW)

Date Volume Gross Date Volume Gross Collected (m')

Deta I 131' Collected (m')

Beta I131*

104)5-96 246* 2.4 i 0.4; 0.6 10-13-96 327 2.0 i 0.3; 0.4 0.5 i 0.6;0.7 10-19-96 246 2.510.4;0.6 10-26-96 295 2.210.3;0.5 0.8 i 0.7;0.7 11-02-96 279 2.410.3;0.5 11 10 96 328 1.910.3;0.4 0.3 i 0.7;0.7 11 16-96 245 1.710.3;0.4 11-23-96 287 2.010.3;0.5 0.5 i 0.7;0.7 12-01-96 328 2.810.3;0.6 12-07-96 244 3.410.4:;0.7 0.5 0.8;0.8 12-15 96 317 2.610.3;0.5 12-21-96 249 3.510.4;0.7

-0.510.7;0.7 12 28-96 285 2.110.3;0.5 4th Qtr. Meants.d. 2.410.6 0.4i0.5

  • Volume bar.ed on a two week collection period.
  • Analysis initiated upon implementation of UREMP. UREMP was implemented on 9-29-96.
  • 1 4

ZION Table 1.

Airborne Particulates and Iodine I-131 Collection:

Airbome Particulates - Continuous; weekly exchange Iodine Cartridges - Continuous; biweekly exchange Required LLD: 0.01 pCi/m' for Gross Beta and 0.07 pCi/m' for I-131 Units:

10 pC1/m' Z-11 (C) WEPCO Southport Substation Date Volume Gross Date Volume Gross Collected (m')

Beta 1-131' Collected (m')

Beta 1-131' 10-05-96 2476 2.0 0.3:0.5 10-13-96 327 1.8 0.3; 0.4

-0.010.7;0.7 10-19-96 246 2.3 1 0.4; 0.5 10-26-96 296 2.2 i 0.3; 0.5 0.010.8;0.8 11-02-96 272 2.210.3;0.5 11 10-96 327 2.310.3;0.5 0.210.6;0.6 11-16-96 245 1.610.3;0.4 11 23-96 287 2.210.3;0.5 0.3 0.8; 0.8 12-01-96 328 2.3 0.3; 0.5 12-07-96 244 3.010.4;0.7

-0.3 i 0.7;0.7 12-15-96 317 2.010.3;0.4 12-21-96 249 3.1 1 0.4;0.7

-0.510.5;0.5 12-28-96 284 2.110.3;0.5 4th Qtr. Meants.d. 2.210.4

-0.0 0.3 4

  • Volume based on a two week collection period.
  • Analysis initiated upon implemention of UREMP. UREMP was implemented on 9 29-96.
  • 15

ZION Table 2.

Airborne Particulates Collection:

Quarterly composites of weekly co!!ections 8

Required LLD: 0.01 pCi/m Units:

10" pCi/m' Sample Description and Concentration Z-01 Onsite No.1. Southside 1996 Collection 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Period Lab Code ZAP-2547,8 ZAP-5030 ZAP-7560 ZAP 9842 Volume 3,247 3,635 3,746 3,449 Mn-54 0.8i 3.9; 3.9

-0.114.7;4.7 1.0i 4.7; 4.7

-1.9 i 7.0; 7.0 Fe-59 4.4 i 12.9; 13.0 8.6 i 11.3; 11.4 8.7 i 15.9; 16.0

-1.4 1.8; 1.8 Co-58

-3.7i 5.5; 5.5 2.0 5.5; 5.5

-2.016.1;6.1 1.018.0;8.0 Co-60 1.1i 4.3; 4.3 2.1 i 5.0; 5.1 2.2i 4.3; 4.3 1.2 i 1.3; 1.3 Zn-65

-0.4 i 9.2; 9.2

-1.1 i 11.3; 11.3

-0.5 i 11.2; 11.2

-9.4116.1;16.2 Zr-NS-95 0.9 7.2:7.2

-5.0 i 10.7; 10.7

-1.3 i 8.0; 8.0

-1.4 i 1.4 ; 1.5 Cs-134 0.2i 5.0; 5.0 5.7i 4.7; 4,8 4.2i 4.9; 5.0 2.0131.7;31.7 Cs-137

-0.314.2;4.2 2.5 1 5.4; 5.4 2.6i 4.0; 4.0

-1.9 i 6.6; 6.6 Ba La 140 5.0 i 26.0; 26.0 18.1 1 27.2; 27.4 1.5124.7;24.7

-94.5 i 60.5; 62.8 Z-02 Onsite No. 2. Westside 1996 Collection 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Period Lab Code ZAP-2549 ZAP-5031 ZAP-7561 ZAP-9843 Volume 3,669 3,716 3,752 3,451 Mn-54 2.318.3;8.3 0.714.7;4.7 2.0i 4.1; 4.1

-3.5 5.9; 5.9 Fe 59

-24.0 i 23.5; 23.9 4.9111.9;11.9

-4.0113.8;13.8

-6.4160.0;60.0 Co-58

-3.11 8.6;8.6 4.015.3;5.3 1.4i 5.2; 5.2 1.51 6.6;6.6 Co.60 4.6i 8.1; 8.1 4.6i 4.4; 4.4

-1.714.1;4.1 0.3 1 0.8; 0.8 Zn-65

-6.8 i 17.9;17.9

-1,6 t 10.0; 10.0

-19.5 i 10.9; 11.4 3.2114.8;14.8 Zr Nb-95

-0.5 i 12.2;12.2 1.7i 7.9; 7.9 1.2i 7.2; 7.2

-6.2 i 10.5; 10.6 Cs-134 0.617.3;7.3 1.8 4.2;4.2 0.415.0;5.0 0.2 0.2;0.2 Cs-137

-0.51 6.3;6.3 3.114.0;4.1 0.5 i 4.5; 4.5 1.3 1 5.8; 5.8 Ba La 140 87.8 i 58.0; 60.1

-23.5 1 28.7; 29.0

-11.5 i 38.7; 38.8 5.7 65.7; 65.7 2-1

ZION Table 2.

Airborne Particulates Collection:

Quarterly composites of weekly collections Required LLD: 0.01 pCi/m'O.01 pCi/m' ~

Units:

10* pCi/m' Sample Description and Concentration Z-03 Onsite No. 3. Northside 1996 Collection 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Period

. Lab Code ZAP-2550 ZAP-5032 ZAP-7562 ZAP-9844 Volume 3,667 3,708 3,744 3,452 Mn-54 0.8 i 4.2; 4.2 5.1 i 4.9; 5.0 3.7i 6.8; 6.8

-1.2 '4.5; 4.5 Fe 59

-9.9 i 13.5; 13.6 1.4 12.5; 12.5

-1.4 i 13.7; 13.7

-1.7i 4.2; 4.2

-I Co-58

-2.3 i 6.2; 6.2

-0.3.t 6.4; 6.4 4.9 i 7.6; 7.7-

-1.0 5.6; 5.6 I

Co-60 3.6 i 4.2; 4.2

-1.5 5.3; 5.3 4.2i 7.4; 7.4 2.0 i 16.4; 16.4 Zn-65

-8.9 i 10.7;10.8

-0.5 i 7.9; 7.9

-1.9 i 16.8; 16.8

-3.6 9.5; 9.5 Zr-Nb-95

-8.4 i 10.1;10.2 0.2i 8.6; 8.6 0.4 i 11.3; 11.3 10.4 i 8.1; 8.3 Cs-134

-2.1 i 5.8; 5.8

-3.2 i 5.0; 5.0

-3.62 6.9; d.9 1.3 8.3;8.3 Cs-137

-1.414.8;4.8

-4.314.9;5.0

-1.6i 7.0; 7.0 0.4 4.4;4.4 Ba La-140

-44.3 36.3; 37.1 2.2 i 36.0; 36.0

-23.0 i 48.7;48.9

-19.5 i 32.0; 32.2 Z-06 Zion (WNW) 1996 Collection 4th Qtr.

Period l

Lab Code ZAP-9845' Volume 3,460 j

i Mn-54 1.9 i 4.1; 4.1 Fe-59

-1.4 i 22.4; 22.4 Co-58

-2.4 i 4.8; 4.8 Co-60

-1.512.7;2.7 Zn-65 4.7i 9.2; 9.2.

Zr-Nb-95 3.5 i 6.4; 6.5 Cs-134

-0.6i 1.6; 1.6 t-Cs-137.

1.0i 4.3; 4.3 Ba-La-140

-33.2 i 74.9; 75.1 i

' Quarterly analysis for gamma initiated upon implementation of UREMP. UREMP was implemented on 92996.

I 2-2

~._ _.~.._ _

ZION Table. 2.

Airborne Particulates Collection:

Quarterly composites of weekly collections

' Required LLD: 0.01 pCi/m' Units:

10. pCi/m' l

d

~ Sample Description and Concentration i

n

~

f 2-11 (C) WEPCO Southoort Substation j

i 1996

~ Collection.

4th Gir.

- Period i

Lab Code ZAP 9846' i

1

. Volume

. 3,454 f

Mn-54 0.8 t 4.4; 4.4 Fe-59

-5.6 i 15.0; 15.0

-c Co-58 2.7i 5.7; 5.8 Co-60

-0.9 i 1.0; 1.0 Zn-65

-0.5 t 12.3; 12.3 4

Zr Nb-95

-6.8i 9.7; 9.8 Cs 134 1.318.3;8.3 Cs-137 3.0i4.2;4.2 Ba La 140

-7.3 i 18.2; 18.2 h

+

4 1

4 4

k 4

- ' Quarterly analysis for gamma initiated upon implementation of UREMP. UREMP was implemented on 92996.

1.

f 2-3 l

ZION Table. ~ 3.

Milk?

1 Collection:

- Semi-monthly May through October

' Monthly November through April Required LLD: 1 pCi/L for 1131;15 pCi/L for Cs 134,137 and Ba-La-140; 20 pCi/L for all other gamma emitters Units:

pCi/L l Sample Description and Concentration -

I Z-27 (Ci Doolittle Dairv i

r Da te -

Collected 01-06-96 02-03-96

.03-02-96 04-06-96 Lab Code ZMI 91 ZMI-539 ZMI 1008 ZMI-1920 I-131

. 0.21 1 0.23;0.23 0.13 i 0.15;0.15

-0.10 t 0.14; 0.14

-0.16 0.14;0.14

[

Mn-54 ~

-0.7i 2.0; 2.0

-0.1i 2.1; 2.1

-1.0i 3.4; 3.4 0.2 2.9; 2.9 Fe-59 3.8i 5.7; 5.7

-0.3 i 4.9; 4.9

-3.6i 7.3; 7.3 4.6 7.3;7.3 Co-58

-2.0i 2.2; 2.2

-0.1 i 1.8; 1.8 1.2 3.4; 3.4 0.8 3.3; 3.3 Co-60 0.8 1 2.2: 2.2

-0.3 i 2.3; 2.3 0.5 i 4.9; 4.9 6.7 4.5;4.5 Zn-65

-2.214.5;4.5

-0.9 i 5.3; 5.3

-1.0i 9.1; 9.1 0.6i 7.5; 7.5 l

Zr Nb-95 1.0i 2.8; 2.8 0.8 i 2.4; 2.4 1.9 i 3.0; 3.0

-0.1 3.3;3.3

[

Cs 134 1.7i 2.3; 2.3 1.512.4;2.4 2.7.i 3.4; 3.4

-1.013.5;3.5 l

Cs 137 0.2i 2.4; 2.4 0.1 i 2.3; 2.3

-1.4 i 3.3; 3.3 0.5i 3.6; 3.6 i

Ba La-140

-1.0i 4.5; 4.5

-1.Si 2.7; 2.7

-1.214.6;4.6

-2.5 3.3:3.5

}

Date l

Collected 05-04 96 05-18-96 06-01-96 06 15 96 Lab Code ZMI-2745 ZMI-3121 ZMI-3447,8 ZMI-3798 1131

-0.04 0.21;0.21

-0.13 i 0.23;0.23

-0.05 0.16;0.16

-0.02 0.30;0.30 Mn-54

-0.112.6;2.6 0.6 2.4; 2.4

-1.3i 2.4; 2.4

-0.2 3.1;3.1 l

t Fe-59

-0.8i 5.2; 5.2 3.8 i 4.4 ; 4.4 3.2i 6.2; 6.3 5.0i 8.0; 8.0 Co-58

-0.112.1;2.1

-1.312.1;2.1 0.4 i 2.5; 2.5

-1.2 3.4;3.4 Co-60 2.6i 3.1; 3.1

-0.213.1;3.1

-0.9 i 3.4; 3.4 0.4 4.6; 4.6 Zn-65

-2.115.9;5.9 0.4 i 5.4; 5.4

-8.0i 6.7; 6.8 4.7 8.3; 8.3 i

Zr-Nb-95 2.212.2;2.2 0.3 t 2.4; 2.4 -

1.2i 2.6; 2.6

-2.3 3.3;3.3 Cs-134 2.1 i 2.5; 2.5

-0.4 i 2.6; 2.6 -

0.012.5;2.5

-0.9i 4.1; 4.1 Cs-137

-0.1 i 2.6; 2.6 2.6i 2.8; 2.8 1.71 2.7;2.7 3.3i 4.0; 4.0 p

Ba-La-140

-0.6 i 2.3; 2.3 0.3 i 3.0; 3.0

-1.1 1 4.5; 4.5 2.1 2.9; 2.9 i

i l

1

  • 3 1

=

. ~

i

ZION Table 3.

Milk Collection:

Semi-monthly May through October

(*

Monthly November through April Required LLD: 1 pCi/L for I 131;15 pCi/L for Cs-134,137 and 15a La-140; 20 pCi/L for all other gamma emitters Units:

pCi/L Sample De'scription and Concentration Z-27 (C) Doolittle Dairv Date Collected 07-06-96 07-20-96 08-03-96 08-17-96 Lab Code ZMI-4364 ZMI-4838 ZMI-5190,1 ZMI-5597 1 131

-0.14 i 0.34;0.34 0.10 i 0.29;0.29 0.33 0.34; 0.34

-0.26 i 0.27;0.27 Mn-54

-0.5 i 2.2; 2.2

-0.412.5;2.5 1.111.9;1.9 1.2 3.2; 3.2 Fe 59 1.615.3;5.3

-0.4 i 5.7; 5.7

-1.415.0;5.0 0.31 7.0;7.0 Co-58

-1.412.3;2.3 0.4 i 2.1; 2.1 1.9i20;2.0

-0.5 i 3.4; 3.4 Co-60

-0.1i 2.6; 2.6

-0.4 2.7; 2.7 0.9i 2.4; 2.4 0.9 4.1; 4.1 Zn-65

-1.1i 5.7; 5.7 0.515.5;5.5

-0.2 1 5.1; 5.1

-1.8i 8.4; 8.4 Zr-Nb-95

-0.9 1 2.3; 2.3

-0.114.6;4.6

-0.7 2.3;2.3 2.0 3.3; 3.3 Cs-134 1.4 i 2.4; 2.4 1.012.3;2.3 0.6i 2.2; 2.3 1.8 3.7; 3.7 l

Cs-137 0.8 i 2.2: 2.2

-0.112.5;2.5 0.412.3;2.3

-1.7 3.7;3.7 Da La-140 2.6 i 1.9; 1.9

-1.713.5;3.5

-2.5 2.7; 2.8

-1.8 3.6; 3.6 Date Collected 09-07-96 09-21-96 10-01 96 Lab Code ZM1-6095 ZMI-6405 NS' I-131 0.24 i 0.27;0.27

-0.28 i 0.44;0.44 Mn-54

-1.312.3;2.3

-1.5 t 2.5; 2.5 Fe-59

-0.9 i 6.4 ; 6.4

-0.415.7;5.7 Co-58 1.212.4;2.4

-1.612.2;2.2 Co-60 1.0 3.0; 3.0

-1.2i 2.9; 2.9 Zn-65

-7.815.2;5.3

-4.6 5.7; 5 F.

Zr-Nb-95

-0.1 i 2.8; 2.8

-0.313.0;3.0 Cs-134

-1.612.4;2.4 0.2i 2.3; 2.3 Cs 137 0.3 i 2.7; 2.7 0.112.5;2.5 Ba-La 140

-4.213.3:3.4 0.2 1 3.1; 3.1

' NS=No sample; location dLscontinued in accordance with UREMP. UREMP was implemented on 9-29-96.

s S-2 4

=. -,

ZION i

Table - 3.

Milk Collection:

Semi-monthly May through October Monthly November through April Required LLD: 1 pCi/L for I-131: 15 pC1/L for Cs 1M,137 and Ba-La-140; 20 pCi/L for all other gamma emitters j

Units:

pCi/L Sample Description and Concentration i

Z-29 (C) Kevek Dairs' j

Date Collected 01-06-96 02-03-96 03-02-96 04 06-06 Lab Code ZMI-92 ZMI-540 ZMI-1009 Zaff-1921 I-131 0.10 1 0.25;0.25 0.10 i 0.15;0.15 0.05 i 0.20;0.20 0.04 = 0.15; 0.15

  • l i

Mn-54 1.2 i 2.8; 2.8 1.1i 2.6; 2.6 0.5 2.3; 2.3 1.0: 2.8; 2.8 Fe 59 1.7i 6.9; 6.9 0.5 i 7.2; 7.2

-5.0t 6.1; 6.2

-0,6 : 7.9;7.9 i

Co-58 0.5 i 2.9; 2.9 2.7i 2.7; 2.8

-0.4 2.2; 2.2

-2.9: 3.2;3.2 Co-60

-0.2 i 4.0; 4.0

-0.6i 3.7; 3.7

-1.0 t 3.1; 3.1 0.4 : 3.8; 3.8 Zn-65 0.2i 7.3; 7.3 1.1i 6.8; 6.8

-0.7 5.6; 5.6 0.9 = 7.7; 7.7 Zr-Nb-95 0.9i 3.8; 3.8 0.413.2;3.2 0.812.4;2.4

-2.6 : 6.1;6.1 Cs-134

-0.2i 3.2; 3.2 1.5 3.1;3.1

-0.312.4;2.4 1.2 : 3.7; 3.7 Cs-137 1.4 i 2.9; 2.9 0.2 3.1;3.1 1.5i 2.3; 2.3 1.6 : 3.2;3.2 f

Ba-La 140

-3.8 i 6.2; 6.2 2.2 3.9; 3.9

-0.6 2.7; 2.7 4.0 3.5;3.5 Date Collected 05-04-96 05-18-96 06-01-96 06 15-96 Lab Code ZMl-2746 ZMI-3122 ZMI-3449 ZAII-3799 l-131 0.03 i 0.19;0.19 0.07 1 0.20;0.20 0.06 0.17;0.17

-0.04 : 0.26;0.26 i

Mn-54 1.71 3.3;3.3 2.4 i 2.5; 2.6 0.8 2.0; 2.0 2.0 : 2.6; 2.6 Fe-59 1.2i 8.6; 8.6

-3.4 i 5.3; 5.3 0.6 5.3; 5.3

-0.3: 5.0; 5.0 Co-58 1.9 i 3.2; 3.2 0.7i 2.5; 2.5 0.2 1 2.1; 2.1

-1.2: 2.5; 2.5 Co-60 1.015.1;5.1

-0.512.5;2.5 0.4 i 2.6; 2.6 0.6 : 2.9; 2.9 Zn.65

-1.8i 8.0; 8.0 2.4 i 5.9; 5.9

-0.615.2;5.2 0.7: 6.1; 6.1 Zr-Nb-95 1.3t 3.7; 3.7

-1.212.9;2.9 0.3 1 2.1; 2.1 1.1 2 2.3; 2.3 Cs-134 0.5 i 3.9; 3.9 1.012.7;2.7 1.0 i 2.2; 2.2 0.4 2.6;2.6 j

Cs 137 '

1.7i 3.5; 3.6 0.2i 2.6; 2.6 1.1 1 2.3; 2.3

-1.6 2.7; 2.7 Da La-140

-2.7i 4.1; 4.1

-1.8 2.5; 2.5 2.8 3.3; 3.4 0.5 : 2.4; 2.4 ee ' r

' 3-3 J.

. ~ _ -~

~

- ZION

- Table 3.

' M ilk' Collection:

Semi-monthly May through October i.,_

3 Monthly November through April.

Required LLD: 1 pCi/L for I-131; 15 pCi/L for Cs-134,137 and Ba La-140; 20 pCi/L for all other gamma emitters l

Units:

pCi/L~

Sample Description and Concentration i

Z-29 (C) Kevek Dairy Date Collected 07-06.07-20-96 08-03-96 08-17-96

. Lab Code ZMI 4365 ZMI 4839 ZMI 5192 ZMI 5598 I-131

-0.09 i 0.31;0.31 0.13 1 0.32;0.32 0.38 1 0.46;0.47

-0.06 0.25; 0.25 I

Mn-54 1.1 i 2.5; 2.5

-1.113.4;3.4 0.7* 3.0; 3.0

-0.2 2.5; 2.5 l

t Fe-59

-0.4 i 6.1; 6.1 5.4 i 8.1; 8.1 6.0 1 9.2; 9.2 1.3 5.8; 5.8 Co-58 0.2i 2.5; 2.5

-0.9 i 3.4; 3.4

-1.5 1 3.5; 3.5

-1.3 2.7; 2.7 Co-60

-1,3i 3.2; 3.2 -

-2.6 i 4.1; 4.1

-5.8 4.4; 4.5

-1.9 3.3; 3.3 Zn-65

-1.415.9;5.9 2.8 i 7.7; 7.7 1.0i 8.9; 8.9 1.6 5.6; 5.6 Zr Nb-95 1.0* 3.1; 3.1 3.2i 3.7; 3.7 0.1i 4.3; 4.3 0.7 2.4; 2.4 l

Cs-134 0.71 2.9;2.9 0.7i 3.8; 3.8 -

-0.6t 4.3; 4.3 0.8 2.8; 2.8

(

Cs 137 0.213.0;3.0

-0.913.5;3.5 0.3 t 3.3; 3.3 '

-0.5 2.7;2.7 Ba La 140.

-0.313.5;3.5-1.0 i 4.5; 4.5 2.9 i 6.2; 6.2

-2.413.3;3.3 I

Date Collected 09-07-96 09-21-96 10-01-96 Lab Code ZMI-6096 ZMI-64%

NS*

l-131

-0.20 1 0.28;0.28

.-0.06 i 0.29;0.29 Mn-54 0.812.4;2.4

-0.7 i 2.2; 2.2 Fe-59 0.415.3;5.3

-0.5 i 6.0; 6.0 Co-58 1.4 i 2.4; 2.4 0.112.4;2.4 Co-60 1.2i 3.0; 3.0 0.2 i 2.8; 2.8 Zn-65

-0.316.0;6.0

-1.2 i 5.2; 5.2 Zr-Nb-95

-0.912.5;2.5 0.5 i 2.6; 2.6 J

C8-134 :

1.5 i 2.6; 2.6 0.2 i 2.6; 2.6 Cs-137 0.1i 2.7; 2.7

-1.012.4;2.4 Ba-La 140 -

0.4 i 4.1; 4.1

-1.013.7;3.7 1

I

  • NS=No sample; location discontinued in accordance with UREMP. UREMP was implemented on 9-29-%.

i t

3.

-u.

mw e-

r i

ZION

Table : 4.

Fish, Edible Portions Collection:

Semiannually Required LLD: 0.13 pCi/g for Cs-134, Cs-137, Co-58,60 and Mn-54; and 0.26 p Ci/g for all other gamma emitters Units:

10'* pCi/g wet weight I

i Sample Description and Concentration Z-24 T2ke Michigan Nearsite ri 3'

Date f

Collected 05-29-96 10-24-96 7

Lab Code ZF-3478 NS*

Type Salmon.

3 Mn-54

-0.2i 0.5; 0.5 I

l' Fe-59 0.3 i 1.6; 1.6 Co-58

-0.410.6;0.6 1

Co40

-0.5 i 0.6; 0.6 Zn-65

-0.4 i 1.3; 1.3 Zr Nb-95

-0.0i 0.8; 0.8 Cs-134,

0.2i 0.5; 0.5 r

Cs-137 5.3 i 1.2; 1.4 Ba La 140

-1.9 i 2.1; 2.1 i

i t

~

l i

I i

1 4

I

'NS = No sample; sample location renamed Z-26 in accordance with UREMP. UREMP was implemented on 9-29-96

  • 41-

m e

1

\\

' ZION -

[

J' Table 4.

Fish, Edible Portions i

~ Collection:

Semiannually k

Required LLD: Mn 54 = 0.13, Fe-59 = 0.26, Co-58 = 0.13, Co-60 = 0.13, Zn45 = 0.26, Cs-134 =

0.1, Cs-137 = 0.1 pCi/g wet weight 4

Units:

10 pCi/g wet weight U

Sample Description and Concentration

(

Z-26 m Take Michiaan Nearsite e

. Date

. Collected 11-02-96 11-02-96 t

)

.th Code ZF-7002*

ZF-7803 f

(Type Perch.

Salmon

~

t Mn-54

-0.4 i 0.8; 0.8

-0.1i 0.5; 0.5 f

a Fe.59 0.212.9;2.9

-0.6i 2.0; 2.0 Co-58 0.1i 1.1; 1.1 0.3 i 0.6; 0.6 Co-60 1.1i 1.1; 1.1 0.1

  • 0.7; 0.7

' Zn-65

-1.1 i 2.2; 2.2 0.2i 1.2; 1.2 l

Zr-Nb-95

-0.1 i 1.7; 1.7

' O.2 1.2; 1.2 j

j Cs 134

-0.1i 0.9; 0.9 0.5

  • 0.6; 0.6 g

Cs-137 1.7i 1.0; 1.1 3.3 i 1.0; 1.1 Ba La 140

-2.2i 5.3; 5.3

-2.1

  • 3.2; 3.2 l

1 i

l i

9 s

i

  • Location formerly labeled Z-24; number changed with implementation of UREMP. UREMP was -

- implemented on 9-29-%.

4

$ e 42 a

~

ZION Table 4.

Fish i

Collection:

Semiannually Required LLD: Mn-54 = 0.13, Fe-59 = 0.26, Co-58 = 0.13, Co40 = 0.13, Zn-65 = 0.26, Cs-134 =

0.1, Cs-137 = 0.1 pCi/g wet weight I

Unitsi 10 pCi/g wet weight l

Sample Description and Concentration Z-27 (C) Take MicWan Farsite Date

. Collected 10 %

10-24-96

- Lab Code ZF-7577' ZF-7578 f

' Type Trout Salmon Mn-54

-0.0i 0.7; 0.7 0.1* 0.8;0.8 l

Fe-59

-1.2i 2.5; 2.5

-0.9 i 1.7; 1.7 Co-58 0.1i 1.0; 1.0 0.2i 0.8; 0.8 Co-60 0.4i 0.8; 0.8 0.4 i 0.9; 0.9 I

Zn 49

-0.9i 2.0; 2.0

-1.4 i 2.1; 2.1 Z,. -N b-95 0.8 i 1.4; 1.4 0.1i 0.8; 0.8 Cs-134

-0.2i 0.9; 0.9 0.2i 0.8; 0.8 Cs-137 7.6i 1.7; 2.0 4.9i 1.8; 1.9 i

Ba-La 140

-4.6 i 4.8; 4.8

-0.3 i 0.4; 0.4

{

i i

I f

i i

I P

)

  • Control location added in accordance with UREMP. UREMP was implemented on 9-29-96.

l 4-3 l

I s

ZION 4

Table 5.

Bottom Sediments Collection:

Semiannually

(

Required LLD: 0.15 pCi/g for Cs-134 and Cs-137 and 0.20 p Ci/g for all other gamma x

emitters. Revised in fourth quarter due to UREMP implementation; 0.15 p Ci/L for Cs-134 and 0.18 p Ci/ L for Cs-137 Units:

10 pC1/g dry weight 4

Sample Description and Concentration Z-25 Y aka Michigan. Illinois Beach State Park I

Date v

Collected 05 18-96 10-05-96 l

Lab Code ZBS-3132 ZBS-6858 i

Mn-54

-0.3 i 1.2; 1.2 0.6i 0.7; 0.7 Fe-59

-0.312.6;2.6 0.6i 1.5; 1.5 Co-58

-0.6i 1.1; 1.1

-0.3i 0.7; 0.7 j

Co-60 1.1i 1.5; 1.5 0.8i 0.8; 0.8 Zn-65

-5.3 i 3.1; 3.1 0.4 i 1.4; 1.4

[

Zr-Nb-95

-0.3 i 1.4; 1.4

-3.1 i 1.1; 1.1 l

Cs-134 2.7i 1.4; 1.5 0.310.6;0.6

[

Cs-137 1.'.

  • 1.4; 1.4 0.8i 0.7; 0.7 i

Ba-La 140

-3.4 i -2.9; 2.9

-2.2i 7.1; 7.1

{

~

f r

i l

f l

5 -1

.j ZION i

Table 6.

Vegetation Collection:

Annually Required LLD: 0.06 pCi/g for Cs-134, Cs-137 and I-131 Units:

10 pCi/g wet weight t

d Sample Description and Concentration l

Z-28 1033rd Street e

Date a

~

09-29-96 09-29-96 09-29-96 l

Collected 09 %

l

!ab Code ZVE-6651 ZVE-6652 ZVE-6653 ZVE-6654,5 Type rutabaga broccoli cabbage collard greens I

I131

-2.11 i 2.70; 2.72

-0.86 i 2.87;2.87

-0.60 i 0.84;0.84

-0.79 1 0.90;0.91 i

Mn-54 1.1i 1.7; 1.7

-0.8 i 1.9; 1.9 0.5i 0.7; 0.7 0.2i 0.7; 0.7 Fe-59 0.5i 3.6; 3.6 3.2i 4.0; 4.1 0.1i 1.7; 1.7 0.3 i 1.8; 1.8 Co-58 0.9i 1.5; 1.5 -

-0.9 i 1.9; 1.9 0.4i 0.6; 0.6 0.2 i 0.7; 0.7

[

i Co-60 1.2i 1.9; 1.9 0.512.2;2.2

-1.3 i 1.1; 1.1

-0.2 i 1.1; 1.1 Zn-65 3.5 i 3.4; 3.4 0.214.4;4.4

-1.3 i 1.9; 1.9

-0.7 1.9; 1.9 Zr-Nb-95

-0.7i 2.0; 2.0

-0.5i 2.0; 2.0 0.2 i 0.7; 0.7 0.210.8;0.8 Cs-134 1.6i 2.1; 2.1

-0.6i 2.4; 2.4

-0.1 0.7; 0.7 0.2i 0.8; 0.8 l

Cs-137 0.7 2.1; 2.1

-0.4 i 2,2; 2.2 0.0i 0.8; 0.8 1.3 i 0.9; 0.9 l

Ba-La-140

-1.3 i 1.9; 1.9

-0.1 i 2.8; 2.8

-0.2i 0.9; 0.9

-0.1 1.0; 1.0 4

f 4

r h

I j

t i

61-4

,m

-e

ZION i

Table 9.

Public Water Collection:

Monthly composites of weekly collections

(

Required LLD: 15 pCl/L for Cs-134, Co-58,60, Mn-54, and Ba-La 140; 18 pCi/L for Cs-137; 30 pCi/L for all other gamma emitters 4 pCi/L for Gross Beta (added in fourth quarter)

Units:

pCi/L

. Sample Description and Concentration 2-14 (C) Kenosha Water Wqda 1996 Collection January February March Period Lab Code ZPW-448 ZPW-927 ZPW-2109 Cross Beta i

Mn-54.

-1.3i 2.0; 2.0 0.3* 1.1; 1.1

-1.1 2.4; 2.4 Fe-59 1.7i 3.9; 3.9

-0.5i 2.2; 2.2

-0.2

  • 6.7; 6.7 Co-58 1.3
  • 2.2; 2.2 0.2i 1.2; 1.2

-2.3

  • 2.8; 2.8 Co-60 0.6i 2.1; 2.1 0.4 i 1.1; 1.1

-0.3i 3.0; 3.0 Zn-65 3.9i 4.6; 4.6

-1.8i 2.2; 2.3

-6.01 7.3;7.3 Zr Nb-95 0.5i 2.6; 2.6 0.511.3;1.3

-1.213.7;3.7 Cs 134 0.9t 2.2; 2.2 1.2i 1.3; 1.3 0.7 i 3.5; 3.5 i

Cs 137

-0.5 i 2.4; 2.4 1.2t 1.3; 1.3 0.11 2.7;2.7 Ba-La-140 -

-0.3

  • 4.2; 4.2

-1.3 i 1.7; 1.7

-1.8i 8.9; 8.9 19 %

Collection April May June Period lab Code ZPW-2736 ZPW-3700,1 ZPW-4546 Gross Beta Mn-54

-1.113.6;3.6

-0.9 i 1.7; 1.7 0.9 i 1.6; 1.6 Fe-59

-2.0i 8.9; 8.9

-0.2i 4.1; 4.1

-2.114.2;4.2 Co-58

-2.1 t 3.7; 3.7

-1,1 1.8;1.8

-0.1i 1.7; 1.7 Co-60

-3.7i 3.8; 3.8 0.2i 1.9; 1.9 0.0i 1.8; 1.8 Zn-65

-0.4 i 8.7; 8.7 2.Si 3.5; 3.6

-3.0i 3.3; 3.3 Zr Nb-95

-1.1i 4.1; 4.1 0.4

  • 2.1; 2.1 0.3i 2.1; 2.1 Cs-134 2.2i 4.4; 4.4 1.1i 1.9; 1.9

-0.4 i 1.8; 1.8 Cs-137 1.3 i 4.4; 4.4

-0.7i 2.0; 2.0

-1.3 i 1.7; 1.7 Ba-La-140 3.1 i 7.7; 7.7 0.5 i 4.1; 4.1

-2.314.5;4.5-

  • NS = No sample;1ocation deleted upon implementation of UREMP. UREMP was implemented on 9-29-%.

u i

9 '- 1 i

. ~ _ - -.. _. _

ZION Table 9.

Public Water Collection:

Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-1M, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/ L for Cs-137; 30 -

pCi/L for all other gamma emitters j

1 4 pCi/L for Gross Beta (added in fourth quarter)

Units:

pC1/L l

1 Sanple Description and Concentration Z-14 (C) Kenosha Water Works 1996 i

Collection July August September l

Period ZPW-5351 ZPW-6110 ZPW-6731 Lab Code.-

Gross Beta i

Mn-54

-1.1i 2.0; 2.0 -

0.2i 1.8; 1.8

-0.1i 2.0; 2.0 l

Fe-59

-0.6i 4.6; 4.6

-1.2i 4.7; 4.7 0.4 i 4.5; 4.5 Co-58 0.8i 2.2; 2.2 0.5 i 2.2; 2.2 0.6 2.2; 2.2 Co-60 1.0i 1.8; 1.8 0.4 t 1.4; 1.4

-1.0 t 1.7; 1.7 Zn-65

-2.6i 4.2; 4.2

-0.9i 3.2; 3.2 0.6i 4.3; 4.3 Zr-Nb-95 0.8 i 2.4; 2.4

-0.5 i 3.2; 3.2 1.7i 2.7; 2.7 i

Cs-134

-0.1i 2.0; 2.0 1.512.0;2.0 0.6 i 2.1; 2.1 Cs-137 0.5 i 2.1; 2.1 0.3 2.0; 2.0

-0.7 2.1; 2.1 Ba La-140 0.4 i 4.4; 4.4 6.2 i 10.4; 10.4 1.8i 5.5; 5.5 1996 Collection October November December Period Lab Code ZPW-8207 ZPW-9031 ZPW-9730 t

Gross Beta.

3.3 i t.1 ; 1.2 3.0 1.4;1.5 1.8 1.4 ; 1.4 l

Mn-54

-0.5 i 1.8; 1.8 1.0i 1.6; 1.6

-1.4 i 2.2; 2.2 Fe-59

-0.6i 4.0; 4.0 2.2 3.9; 3.9

-2.7i 5.1; 5.1 Co-58

-1.4 i 1.9; 1.9

-1.3 i 2.2: 2.2 1.6 2.3; 2.3 Co-60 1.5i1.3;1.3 0.111.7;1.7 0.2i 1.8; 1.8 Zn-65 0.3i 2.5; 2.5

-1.7 i 3.6; 3.6

-2.5 i 4.1; 4.1 -

Zr Nb-95 2.6i 2.7; 2.7 0.1 2.8; 2.8 1.3i 3.1; 3.1 I

C5-134

-0.2 i 1.9; 1.9 2.512.3;2.4 1.4 i 2.4 ; 2.4 l

Cs 137 0.312.0;2.0

-1.1 i 1.8; 1.8 0.112.4;2.4 Ba La 140

-0.8 i 5.8; 5.8

-2.8i 5.2i 5.2

-4.9 i 8.3; 8.3

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

1 9 -2

~.

~..

ZION Table 9.

Public Water

(;;

Collection:

Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, md Ba-La-140; 18 pCi/L for Cs-137; 30 t

pCi/L for all other gamma emitters 4 pCi/L for Gross Beta (added in fearth quarter)

Units:

pCi/L Sample Description and Concentration Z-15 I mka County Water Works 1

1996 Collection -

January February March.

i

, Period

. Lab Code ZPW-449 ZPW-928 ZP W 2110 l

- Gross Beta Mn-54

-1.3 i 1.1; 1.1 0.6i 1.4; 1.4

-1.2 i 1.9; 1.9 Fe-59

-0.5i 2.4; 2.4

-1.0i 2.8; 2.8 3.314.5;4.5 Co-58

-0.9 i 1.2; 1.2 0.3 i 1.4; 1.4

-0.1 i 2.4; 2.4 Co-60 0.8 i 1.1; 1.1

-0.5 i 1.6; 1.6

-0.3 i 1.9; 1.9 Zn-65

-0.8 i 2.3; 2.3 0.71 3.0;3.0 2.313.2;3.2 Zr Nb 95 1.0i 1.4; 1.4 0.1 i 1.6; 1.6 1.0i 3.9; 3.9 Cs-134 0.0 i 1.2; 1.2

-0.8 i 1.5; 1.5

-0.8 t 2.2: 2.2 g

Cs-137 1.3 t 1.2; 1.2 1.2i 1.7; 1.7 1.8 i 2.3 2.3

'.i.,

l Ba-La 140 0.7i 2.7; 2.7

-1.4 i 2.7; 2.7

-2.215.4;5.4 1996 Collection April May June i.

Period Lab Code ZPW-2737 ZPW-3702 ZP W 4547 I

i Gross Beta

.i Mn-54

-1.6i 3.0; 3.0 0.3 1 2.3; 2.3 0.111.5;1.5 Fe-59 1.817.1;7.1

-1.4 i 5.4; 5.4 2.313.6;3.6 Co 58 2.5 i 2.5; 2.5 0.6 i 2.7; 2.7 1.1 i 1.6; 1.6 Co-60 0.4 i 2.5; 2.5 1.4 i 2.7; 2.7 0.5 i 1.5; 1.5 Zn-65 0.3 i 6.4; 6.4

-2.3i 6.1; 6.1 1.3 i 2.7; 2.7 3

Zr-Nb-95 1.1

  • 3.2; 3.2 1.7i 3.3; 3.3 1.1i 1.7; 1.7 j

- Cs-134 -

0.3 i 3.0; 3.0 1.312.8;2.8-0.5 i 1.6; 1.6 i

Cs-137

-2.4i 3.0; 3.0 0.8i 2.8; 2.8 0.7i 1.4; 1.4 Ba La 140

-2.2 i 8.1; 8.1

-6.8 i 4.1; 4.2 2.0i 3.3; 3.3 i

NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

9. - 3 r

r,

-c.

p I

ZION Table 9.

Public Water Collection:

Monthly composites of weeldy collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/L for Cs-137; 30 i

pCi/L for all other gamma emitters

' 4 pCl/L for Gross Beta (added in fourth quarter)

Units:

pCi/L Sample Description and Concentration Z-15 Lake County Water Works 1996 Collection July August September Period Lab Code ZPW-5352 ZPW-6111 ZP W 6732 Gross Beta Mn-54 1.4 i 1.9; 1.9 1.3 2.1; 2.1 1.1 i 1.8; 1.8 Fe 59

-0.6 i 5.1; 5.1

-6.2i 5.6; 5.6 2.9i 4.4; 4.4 Co-58 0.8 i 2.4; 2.4

-1.11 2.6;2.6

-1.0 1.9; 1.9 Co-60

-0.4 2.0; 2.0 0.1 i 1.8; 1.8 0.6 i 1.9; 1.9 Zn-65

-1.2i 4.1; 4.1

-0.7i 4.9; 4.9 0.5 3.3; 3.3 Zr Nb-95 0.3 i 3.0; 3.0

-0.9 i 3.8; 3.8

-0.2 2.4; 2.4 Cs-134 0.6i 2.5; 2.5 3.0i 2.3; 2.3 1.0 i 2.0; 2.0 Cs-137 0.1i 2.2; 2.2

-0.112.3;2.3

-0.1 2.0; 2.0 Ba La-140 0.6i 5.8; 5.8

-8.0i 7.2; 7.3 2.315.7;5.7

?

1996 Collection October November December Period Lab Code ZPW-8208 ZPW-9032 ZPW-9731 Gross Beta 1.7 i t.0; 1.0 3.3 i l.5 ; 1.6 3.1 1.5 ; 1.6 Mn-54

-0.9 i 1.8; 1.8

-1.1i 2.7; 2.7 0.5i 2.4; 2.4 Fe-59

-1.015.0;5.0 0.7i 6.6; 6.6 1.2t 5.9; 5.9 Co-58

-1.1i 2.1; 2.1

-2.0 2.7;2.7

-1.4 i 2.8; 2.8 Co-60

-0.2i 1.7; 1.7 0.213.8;3.8 1.5 i 2.9; 2.9 Zn-65 0.7i 4.4; 4.4

-1.2 i 6.3; 6.3

-1.215.4;5.4 Zr-Nb-95

-0.212.8;2.8

. 0.3 i 3.7; 3.7

-0.213.5;3.5 i

Cs-134

-0.9 i 2.0; 2.0 0.113.2;3.2

-1.0i 2.9; 2.9

' Cs 137 3.2

  • 2.2; 2.2

-0.813.7;3.7 0.2i 2.6; 2.6 Ba La 140

-2.514.9;4.9 1.6i 7.6; 7.6

-2.4 i 9.8; 9.8

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

I i

9 -4 f

ZION Table 9.

Public Water Collection:

Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba La 140; 18 pCi/ L for Cs-137; 30 pCi/L for all other gamma emitters 4 pCi/L for Gross Beta (added in fourth quarter)

Units:

pCi/L Sample Description and Concentration Z-16 Waukegan Water Works 1996 Collection January February March Period Lab Code ZPW-450 ZPW-929 ZPW-2111 Gross Beta Mn-54

-0.6 i 2.4; 2.4 0.4 i 0.7; 0.7 1.6i 2.4; 2.5 Fe-59 3.6 1 6.2; 6.2

-0.311.4;1.4

-0.6i 5.8; 5.8 Co-58 0.512.9;2.9

-0.1 i 0.7; 0.7 0.2 2.8; 2.8 Co-60 0.613.0;3.0 0.5 i 0.8; 0.8 1.8i 3.2; 3.2 Zn-65 1.6i 5.3; 5.3

-1.311.4;1.4

-2.5i 6.0; 6.0 Zr-Nb-95 0.2 i 3.2; 3.2

-0.010.8;0.8

-1.313.3;3.3 Cs-134

-2.3 2.5; 2.5 0.7i 0.8; 0.8

-1.2 2.7; 2.7 Cs-137 0.6 i 2.7; 2.7

-0.6 i 0.8; 0.8 1.213.0;3.0 Ba-La-140

-5.2i 5.5; 5.5 0.4 i 1.0; 1.0

-3.3 i 8.0; 8.0 1996 Collection April May June Period Lab Code ZPW-2738 ZPW-3703 ZPW-4548 Gross Beta Mn-54 0.3 i 3.7; 3.7

-2.3i 2.5; 2.6

-0.4 i 1.8; 1.8 Fe-59 1.5 i 7.3; 7.3

-1.6i 5.5; 5.5

-3.413.9;3.9 Co-58

-1.114.5;4.5 0.2i 2.6; 2.6 1.412.3;2.3 Co-60 3.1 i 4.6; 4.7

-0.512.4;2.4 0.911.9;1.9 Zn-65

-6.8 i 10.2: 10.2 2.9 i 6.0; 6.0 1.114.1;4.1 Zr-Nb-95 0.615.0;5.0

-0.313.0;3.0 0.3 1 2.6; 2.6 Cs 134 4.8i 4.8; 4.8 0.8 i 2.5; 2.5

-0.9i 2.3; 2.3 Cs 137 0.8 i 4.0; 4.0 1.3 i 2.6; 2.6 1.9 t 2.4; 2.4 Ba-La-140

-2.3111.2;11.2 1.6i 7.2; 7.2

-1.2 i 3.6; 3.6

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

9 -5

i ZION Table 9.

Public Water Collection:

Monthly composites of weekly collections j

Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/ L for Cs-137; 30 pCi/L for all other gamma emitters 4 pCi/L for Gross Beta (added in fourth quarter)

Units:

pCi/L Sample Description and Concentration Z-16 Waukegan Water Worjgi 1996 Collection July August September Period Lab Code ZPW-5353 ZPW-6112 ZPW-6733 Gross Beta Mn-54

-1.2i 2.7; 2.7 0.8i 2.4; 2.4 0.3i 2.1; 2.1 Fe-59 0.7i 6.7; 6.7 0.6i 4.8; 4.8

-1.1 i 4.2; 4.2 Co-58

-1.8i 2.9; 2.9 0.2i 2.9; 2.9

-0.912.4;2.4 Co-60

-0.4 i 2.7; 2.7

-0.2 t 2.2; 2.2 0.4 1.7; 1.7 Zn-65 4.4 i 6.7; 6.7 1.9i 5.5; 5.5

-3.0 4.0; 4.0 Zr-Nb-95

-3.2i 4.2; 4.2 0.5 5.8; 5.8 1.1 1 2.8; 2.8 Cs-134 0.S i 3.1; 3.1 1.1i 2.5; 2.5 0.5 i 2.4; 2.4 Cs-137 0.512.8;2.8

-0.5 i 2.6; 2.6 0.4 2.5; 2.5 Ba-La-140

-6.0i 8.4; 8.4

-2.3 i 17.4; 17.4

-2.8 5.1; 5.1 1996 Collection October November December Period Lab Code ZPW 8209 ZPW-9033 ZPW-9732 Gross Beta 2.1 i 1.0 ; 1.0 5.2 i 1.6 ; 1.8 2.9 1 1.4 ;1.5 Mn-54

-0.6i 2.3; 2.3 2.5 i 3.4; 3.4

-1.2 i 1.4 ; 1.4 Fe-59 3.7i 8.2; 8.2 0.9i 8.9; 8.9 2.5i 3.7; 3.8 Co-58 1.6i 3.3; 3.3

-1.313.6;3.6 0.5 1.7; 1.7 Co-60 1.6i 3.4; 3.4 2.7i 4.7; 4.7 0.111.5;1.5 Zn-65

-0.9 i 6.8; 6.8

-1.618.4;8.4

-2.6 2.9; 2.9 Zr-Nb-95

-2.1i 2.9; 2.9

-1.6i 5.4; 5.4

-1.8i 2.3; 2.3 Cs-134 0.5 t 2.3; 2.3

-0.7i 3.0; 3.0 0.3 t 1.6; 1.6 Cs-137 2.2i 2.8; 2.8

-0.314.0;4.0 0.1 i 1.6; 1.6 Ba-La-140 3.2 i 7.5; 7.5 6.6 i 8.2; 8.3

-3.6i 5.7; 5.7

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

9 -6

ZION Table 9.

Public Water

' Collection:

Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/ L for Cs-137; 30

(.

~'

pCi/L for all other gamma emitters Units:

pCi/L Sample Description and Concentration h4 orth Chicago Water Works Z-17 (C) 19 %

- Collection January February March Period fab Code ZPW-451 ZPW-930 ZPW-2112 Gross Beta Mn-54 0.8 i 2.5; 2.5

-0.Si 1.5; 1.5 0.1 2.0; 2.0 Fe-59

-4.4 i 6.2; 6.2

-1.3i 3.5; 3.5

-0.2 i 3.5; 3.5 Co-58

-1.3 i 2.8; 2.8

-0.7t 1.6; 1.6

-0.1i 2.2; 2.2 Co-60 1.7i 3.4; 3.4 0.2i 1.7; 1.7 1.9 i 2.1; 2.1 Zn -0.314.0;4.0

-1.5i 3.4; 3.4 0.913.4;3.4 Zr Nb-95

-0.8i 2.8; 2.8

-1.311.7;1.7 0.1i 2.4; 2.4 Cs-134

-1.4 2.8;2.8

-0.911.6;1.6

-0.2i 2.0; 2.0 g

Cs-137

-0.3 2.8; 2.8

-0.1 t 1.7; 1.7 1.312.1;2.1

-i Ba La-140

-2.4 i 7.2; 7.2 0.6i 2.5; 2.5 '

O.6i 5.9; 5.9 1996 Collection April May June Period Lab Code ZPW-2739 ZPW-3704 ZPW-4549,50 Gross Beta 1

Mn-54

-0.1i 3.0; 3.0 1.0i 1.9; 1.9 0.9 i 1.1; 1.1 Fe-59 3.0 1 6.2; 6.2 2.9i 4.1; 4.1 0.812.4;2.4 Co-58 2.413.1;3.1 0.9 i 2.2; 2.2 0.111.1;1.1 Co-60

-2.4i 3.0; 3.1 0.8i 1.8; 1.8

-0.4 i 1.0; 1.0 Zn-65

-2.4i 6.8; 6.8 0.513.8;3.8

-2.6 2.4; 2.4 Zr-Nb-95

-2.513.4;3.4 0.1i 2.5; 2.5

-0.4 i 1.4; 1.4 Cs 134 0.7i 3.5; 3.5 0.312.0;2.0

-0.3 i 1.3; 1.3

- Cs-137 ~

-0.613.3;3.3-1.0 t 2.2; 2.2

-0.9 i 1.3; 1.3 i

Ba-La-140 2.6 i 8.1: 0.1

-1.1 4.2; 4.2

-3.71 2.7;2.8

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

4 9 -7 i

\\

l

)

ZION Table 9.

Public Water Collection:

Monthly composites of weekly collections Required LLL. 15 pCi/L for Cs-134, Co-58,60, Mn-54, and Ba-La 140; 18 pCi/L for Cs-137; 30 pCi/L for all other gamma emitters Units:

pCi/L Sample Description and Concentration 2-17 (C) North Chicago Water Works 1996 Collection July August September Period Lab Code ZPW-5354 ZPW-6113 ZPW-6734 Gross Beta Mn-54 1.0 i 1.6; 1.6

-0.1 i 2.4; 2.4

-0.1 1.9; 1.9 Fe-59 0.4 i 4.2; 4.2 0.7i 7.8; 7.8

-1.8i 4.8; 4.8 Co-58

-0.1i 2.1; 2.1

-1.3 3.0; 3.0 0.7 2.0; 2.0 Co-60 0.8 i 1.5; 1.5 0.7 i 2.5; 2.5

-0.3i 2.0; 2.0 Zn-65

-4.1i 3.3; 3.3

-5.li 5.1; 5.2

-6.3 4.4; 4.5 Zr-Nb-95 0.3i 2.9; 2.9 1.9 i 3.7; 3.7 1.2 2.7;2.7 Cs-134

-0.6 2.1; 2.1

-2.113.0;3.1 0.4 1.9; 1.9 Cs-137 0.3i 2.0; 2.0 0.3i 2.9; 2.9 0.1i 2.4; 2.4 Ba La-140 0.7i 6.2; 6.2

-13.6 i 18.2; 18.3

-1.6i 4.7; 4.7 1996 Collection October Period Lab Code NS' Gross Beta Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba La 140

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

9.-8

i ZION Table 9.

. Public Water Collection:

Monthly composites of weekly collections

'(

j _

Required LLD: 15 pCi/L for Cs 134, Co-58,60, Mn-54, and Ba La-140; 18 pCi/L for Cs-137; 30 pCl/L for all other gamma emitters 4 pCi/L for Gross Beta (added in fourth quarter)

Units:

pCi/L Sample Description and Concentration 218 (C) Iike Forest Water Works 1

' 1996 Collection January -

February March

- Period Lab Code ZPW-452 ZPW-931 ZPW 2113 Gross Beta

- Mn-54

-0.4i 1.8; 1.8

-0.8 i 1.9; 1.9 1.3 i 1.9; 1.9 Fe-59 0.6i 4.1; 4.1

-1.9i 4.4; 4.4 2.2 i 5.1; 5.1 Co-58

-0.3 i 2.0; 2.0 0.8 t 2.0; 2.0 0.8 i 2.6; 2.6 Co-60

-0.1i 2.1; 2.1 1.8i 2.2; 2.2 1.6i 2.0; 2.0 Zn-65 1.4 i 3.6; 3.6

-5.4 i 4.5; 4.6

-1.0t 4.3; 4.3 Zr-Nb-95 0.1i 2.2; 2.2 0.6i 2.3; 2.3 1.5i 3.0; 3.0 Cs-134 1.4 i 2.0; 2.0 0.6i 2.2; 2.2 0.2i 2.1; 2.1

,n Cs-137 0.3i 2.2; 2.2

-0.8i 2.2; 2.2 2.112.5;2.5 Ba-La 140 2.0i 4.9; 4.9 1.2i 3.4; 3.4

-3.3 i 6.9; 6.9 1996 Collection April May June Period Lab Code ZPW 2740 ZPW-3705 ZPW-4551 Gross Beta

. Mn-54 2.8i 3.5; 3.5 0.6t 2.3; 2.3 0.6 i 1.9; 1.9

~ Fe 59 0.8i 6.7; 6.7

-0.4

  • 6.8; 6.8 5.5i 4.8; 4.8 Co-58 0.513.0;3.0 0.3i 3.1; 3.1 0.3 i 2.2; 2.2 Co-60

-2.6 3.1; 3.1 3.2i 2.S; 2.6

-0.6i 2.1; 2.1 Zn-65

-1.1i 5.4; 5.4

-0.5 i 5.9; 5.9 0.7 4.2; 4.2 Zr-Nb-95 1.0i 4.0; 4.0

-1.3i 5.0; 5.0

-0.1 i 2.5; 2.5 Cs 134

-0.2 i 2.5; 2.5 1.8 i 2.6; 2.6 2.0 1 2.2; 2.2 Cs 137

-0.3 i 3.5; 3.5

-3.1i 3.1; 3.2 0.6i 2.4; 2.4 Ba La 140

-5.9 i 5.0; 5.0 -

0.3 i 5.0; 5.0 2.0i 5.0; 5.0

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-%.

p '- 9

-. ~.

ZION Table 9.-

Public Water Collection:

Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co-58,60, Mn 54, and Ba La-140; 18 pCi/L for Cs-137; 30 pCi/L for all other gamma emitters 4 pCi/L for Gross Deta (added in fourth quarter)

Units:

pCl/L

- Sample Description and Concentration 4

2-18 (C) i ake Forest Water Works 1996

' Collection.

July August September Period I

Lab Code ZPW-5355 ZPW-6114 ZPW 6735 '

4-Gross Beta Mn-54 0.5i 2.0; 2.0 0.5i 2.7; 2.7

-1.1 i 2.4 ; 2.4 Fe-59

-3.3 i 5.3; 5.3 3.4 i 7.9; 7.9 0.8 i 7.0; 7.0 Co-58 0.4 i 2.2; 2.2 1.0i 3.1; 3.1

-1.013.3;3.3 Co-60 0.7i 1.9; 1.9 2.5 i 2.6; 2.6 2.7i 2.5; 2.5

.Zn -0.2i 4.0; 4.0

-2.1 i 6.0; 6.0

-3.0i 6.2; 6.2 Zr Nb 95 0.1 2.7; 2.7 0.4 i 4.9; 4.9 0.6 5.8;5.8 Cs 134 0.4 i 2.4; 2.4 1.213.7;3.7 06i2.3;2.3 Cs-137

-0.5 i 2.5; 2.5 1.7i 3.4; 3.4

23. .9; 2.9 Ba-La 140

-1.9 i 7.2; 7.2

-11.5 i 17.0; 17.1 5.6 i 7.8; 7.8 1996 y

Collection October November December Period Lab Code ZPW-8210 ZPW-9034 ZPW 9733 Gross Beta 1.810.6;0.7 3.0 i t.5 ; 1.6 2.9 i 1.5 ; 1.5 Mn-54 0.1 i 1.6; 1.6 0.5 i 2.5; 2.5 0.1 i 1.9; 1.9 Fe 59 0.7i 4.2; 4.2 0.5i 5.2; 5.2 3.7 5.2:5.2 Co-58 1.4 i 2.5; 2.5

-0.9 i 2.7; 2.7

-0.1i 2.5; 2.5 Co-60 1.9 i 1.8; 1.8 1.8 i 2.7; 2.7

-0.5 1 2.3; 2.3 2n-65

-2.313.7;3.7 0.2 i 5.8; 5.8

-5.514.8;4.9 Zr Nb-95 2.5i 3.8; 3.8 0.8 i 3.1; 3.1 0.212.8;2.8 Cs 134 0.5 i 2.1; 2.1 1.4 i 2.2; 2.2 1.6 i 2.0; 2.0 Cs-137 -

--1.012.4;2.4 0.6 i 2.9; 2.9 0.7i 2.0; 2.0 Ba La-140

-1.1

  • 5.7; 5.7 3.3 1 8.4; 8.4 10.1 10.1; 10.2 l
  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

~

l 9 - 10

ZION Table. 9.

Public Water a

Collection:

Monthly composites of weekly collections h~

Required LLD: 15 pC1/L for Cs-134, Co-58,60, Mn-54, and Ba-La-140; 18 pCi/ L for Cs 137; 30 pCi/L for all other gamma emitters 4

Units:

pCi/L Sample Description and Concentration L

Z-19 (C) Creat Takes Naval Trainine Center 4-1996 l Collection January February March Period Lab Code ZPW-453 ZPW-932,3 ZPW-2114 Gross Beta t

Mn-54 0.1 1.7; 1.7

-0.5 i 1.5; 1.5

-2.9 i 3.2; 3.2 Fe 59 0.5i 3.7; 3.7

-0.9i 3.3; 3.3 7.8 i 6.4; 6.4 Co-58

-1.4 i 1.6; 1.6 0.2i1.4;1.4

-0.4i 3.0; 3.0 Co-60

-0.3 i 1.9; 1.9 0.4 i 1.4; 1.4

-0.6i 3.3; 3.3 Zn 65'

-1.6i 3.7; 3.7 0.5i 2.8; 2.8 1.8i 6.2; 6.2 l

Zr Nb-95 1.0i 2.1; 2.1 0.6i 1.7; 1.7

-0.4 1 3.9; 3.9 f

Cs-134 1.3i 1.8; 1.8 0.1 i 1.6; 1.6 0.1i 3.6; 3.6 fa.

Cs-137 0.9 i 1.8; 1.8 0.4i 1.7; 1.7 1.2 1 3.1; 3.1 Ve 7

Ba La-140

-1.3 3.7; 3.7 2.4 i 2.3; 2.4 2.5i 8.0; 8.0 '

1996 Collection April May June l

Period Lab Code ZPW-2741 ZPW-3706 ZPW-4552 j

I Gross Beta Mn-54 0.5 i 2.9; 2.9 0.3i 1.5; 1.5

-0.8i 2.2: 2.2 Fe-59

-4.016.9;6.9

-0.8 i 4.2; 4.2

-1.7 i 5.3; 5.3 i

Co-58 3.3 t 3.0; 3.1 0.2i 1.8; 1.8 2.4 2.4; 2.4 l

Co40.

-0.8 i 3.4; 3.4 0.1i 1.8; 1.8

-1.2i2.32.3 Zn-65 2.0i 6.8; 6.8

-1.1i 2.9; 2.9

-2.114.0;4.0 Zr-Nb-95 0.6i 3.9; 3.9 0.4 i 2.2; 2.2

-1.212.9;2.9 Cs-134 1.4 i 3.2; 3.2 0.2i.2.3;2.3 0.912.6;2.6 l

'Cs-137

-1.7i 3.6; 3.6 0.3i 1.8; 1.8 0.8 1 2.6; 2.6 i

Ba La 140

-5.3i 7.9; 7.9 2.4 i 3.7: 3.7 0.1 i 7.8; 7.8 l

  • NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96.

9 - 11

l i

./

ZION.

Table -9.'

Public Water Collection:

Monthly composites of weekly collections Required LLD: 15 pCi/L for Cs-134, Co 58,60, Mn-54, and Ba-La 140; 18 pCi/L for Cs-137; 30 pCi/L for all other gamma emitters 1

Units:

pCi/L I

)

Sample Description and Concentration Z-19 (C) Creat i mLa Naval Training Center i

1996 Collection July August September i

Period

' Lab Code ZPW-5356 ZPW-6115 ZPW-6736

--Gross Beta Mn-54 1.4 i 1.9; 1.9 0.6i 2.1; 2.1 0.2 2.0; 2.0 Fe-59 1.0i 5.1; 5.1

.-0.8 6.2; 6.2

-1.1i 4.4; 4.4 Co-58 1.2i 2.0; 2.0 0.3i 2.6; 2.6

-0.2i 2.0; 2.0

- Co-60 0.4 i 2.0; 2.0 2.5 2.1;2.1 0.3 1.6; 1.6 Zn-65 0.2i 2.8; 2.8

-4.7i 4.3; 4.3

-0.8i 4.1; 4.1 Zr Nb-95

-0.3 i 2.6; 2.6 1.6i d.2; 4.2

-1.4i 2.9; 2.9

_j

. Cs-134

-0.5i 2.0; 2.0 1.7i 2.1; 2.1 0.212.1;2.1 j

Cs-137 0.5 t 1.8; 1.8

-0.7i 2.5; 2.5 0.4 i 2.2 2.2 j

Ba-La 140

-5.7i 4.6; 4.6 1.3 i 13.9; 13.9

-0.6i 5.4; 5.4 1996 Collection October Period Lab Code NS' j

Gross Beta I

Mn 54 -

Fe-59 Co -

Co-60 Zn-65

^

Zr-Nb-95 '

Cs-134 Cs-137 Ba La 140 l

' NS = No sample; location deleted upon implementation of UREMP. UREMP was implemented on 9-29-96 I

e

. 9. - 12 i

ZION

- Table 9.

Public Water Collection:

Quarterly composites of weekly collections Required LLD: 200 pC1/L

(;

Units:

pC1/L 1996 Sample Description and Concentrafion Collection Period Lab Code Tritium 2-14 (C) Kenor.ha Water Works 1st Quarter ZPW.1754 73 i 119;120 1

2nd Quarter ZPW 4210 48 i 80;81 3rd Quarter ZPW-6675,6 55 i 58;58 4th Quarter ZPW-9437 91 i 84;85 j

i 2-15' i aka County Water Works 1st Quarter ZPW-1755 63 1 119;119 2nd Quarter Z P W-_ 4211 14 i 79;79 3rd Quarter ZPW-6677 124 1 87;88 4th Quarter ZPW. 9438 116 i 85;87 N

Z-16 Waukeean Water Works 1st Quarter ZPW-1756 28 i 118;118 2nd Quarter ZPW-4212 64i 81;82 3rd Quarter ZPW-6678 37 i 83;83 4th Quarter ZPW-9439 74 i 83; 84 Z-17 (C) North Chicaco Water Works 1st Quarter ZPW-1757,8 79 1 84;85 2nd Quarter ZPW-4213 581 81 81 3rd Quarter ZPW. 6679 158 i 88;91 4th Quarter ZPW. NS' 1

i 4

  • NS = No sample; location deleted upon implementation of UREMP on 9-29-96.

i 9-13.

r m

4 L - -- - - - - - - -

l i

?

ZION i

l Table 9.

Public Water -

Collection:

' Quarterly composites of weekly collections Required LLD: 200 pCi/L Units:

pCi/L

{

1996 Sample Description and Concentration J

Collection Period lab Code Tritium j

Z-18 (C) imke Forest Water Works i

L 1st Quarter.

ZPW-1759 69 80;80 2nd Quarter ZPW 4214 104 83; 84

' 3rd Quarter ZPW-6680 88 85;86 i.

4th Quarter ZPW-9440 123 85;87 i

219 (C) Creat Lakes Naval Training Center i

i I

1st Quarter ZPW-1760 162 84; 86 1

1 2nd Quarter ZPW-4215,6 81 57;57 3rd Quarter ZPW-6681 50 84; 84 l

4th Quarter ZPW-NS' e

}

I r

l f

4 J

9 i

1

  • NS = No sample; location deleted upon implementation of UREMP on 9-29-96.

t 9 14 i

)

~.

t ZION l

Table 10.

Cooling Water Collection:

Weekly e

Required LLD: 4 pCi/L pCl/L 4

Date Date Collected Lab Code Gross Beta' Collected Lab Code Gross Beta' r

Z-22 (C) Unit 1 Inlet 01-04-96 ZCW-93 2.0 i 1.3 ; 1.3 07-04-96 ZCW-4390 3.5 1.6 ; 1.6 01-11-96 196 2.3 i 1.4 ; 1.5 07-11 96 4686 2.7 1.1;1.2 01-18-96 289 2A i 1.3 ; 1.3 07-18 96 4840 1.2 1.4 ; 1.4 01 25-96 354 1.911.3;1.4 07-25-96 4975 2.0 1.3;1.4 02-01 96 541 1.8 i 1.2 ; 1.2 08-01-96 5221 1.4 1.3 ; 1.3 02-08-96 685 1.9 i l.4 ; 1.4 08-08-96 5402 0.8 i 1.2 ; 1.2 02 15-96 826 1.1 i 1.3; 1.3 08-15-96 5614 0.5 i 1.2 ; 1.2 02 22-96 890 3.0 i 1.4 ; 1.5 08-22-95 5779 2.711.4;1.4 02 29 96 1010 3.0 i 1.5 ; 1.6 08-29-96 5964 0.9 i 1.2 ; 1.2 03-07 96 1201 2.8 i 1.5 ; 1.6 09-05-96 6139 3.3 1.4 ; 1.5 03-14-96 1391 1.4 i 1.4 ; 1.4 09-12-96 6305 3.3 i 1.4 ; 1.5 03 21-96 1539 2.5 i 1.5 ; 1.5 09 19-96 6432,3 3.3 i 1.1 ; 1.2 03-28-96 1711 2.2 i 1.5 ; 1.5 09-26-96 6623 3.7 i 1.6 ; 1.7 Ist Qtr. meant s.d.

2.2 i 0.6 3rd Qtr. meani s.d.

2.3 1.2 04-04 96 ZCW-1922 2.4 1.5 ; 1.5 10-05-96 ZCW-6850 1.5 i 1.4 ; 1.4 04-11 96 2096 2.3 i 1.5 ; 1.5 10-10-96 7175 2.8 i 1.5 ; 1.6 04-18-96 2339 1.7 t l.4 ; 1.4 10-17-96 7402 2.8 i 1.8 ; 1.9 04 25-96 2477 2.9 i 1.4 ; 1.5 10-24-96 7626 1.411.2;1.2 05-02-96 2765 1.9 i 1.4 ; 1.5 10-31-96 7794,5 1.210.9;0.9 05-09-96 2991 1.3 i 1.4 ; 1.4 11-07-96 8088 2.5 1.8 ; 1.8 05 16-96 3123 2.4 i t.5 ; 1.5 11-14-96 8302,3 1.6 i 1.1 : 1.1 i

05 23 96 3355 2.0 i 1.4 ; 1.5 11-21-96 M25 1.7 1.4;1.4 05-30-96 3469 1.0 i 1.4; 1.4 11 28-96 8611 1.8 1.4 ; 1.4 06-06-96 3662 1.5 i 1.4; 1.4 12-0546 8822 2.0 i 1.4 ; 1.4 06-13-96 3800,1 5.1 i 1.2; 1.4 12-12-96 9100 2.9 i 1.7 ; 1.8 06 20-96 3947-3.8 i 2.9 ; 3.0 12-19-96 9255 1.7 i 1.7 ; 1.7 06-27 96 4195 2.311.4;1.4 12-26-96 9380 1.9 i 1.7 ; 1.7 l

2nd Qtr. meant s.d.

2.4 i 1.1 4 th Qtr. meant s.d.

2.0 1 0.6

  • Total gross beta; cooling water and water filters.

10 1

..=1

~<v

.m

v i

t ZION Table' 10.

Cooling Water j

Collection:

Weekly Required LLD: 4 pCi/L Units:

. pCi/L j

Gross Beta l

Date Sospended Dissolved Total Collected lab Code Solids Solids Residue 2-23N Unit 2 Discharge 01-04-96 ZCW-94

-0.110.9;0.9 3.621.5;1.6 3.5 1.8 ; 1.9 01 11-96 197

-0.0 i 1.0 ; 1.0 1.8 1.3 ; 1.3 1.711.7;1.7 01 18-96 290 0.2 i 0.9; 0.9 3.0 i 1.5 ; 1.5 3.2 i 1.8 ; 1.8

{

01 25-96 355,6

-0.1 i 0.7; 0.7 2.2 i 0.9 :0.9 2.1 1.1 ; 1.1 l

= 02 01-96 542

-0.8 0.9 ; 0.9

- 3.1 i 1.4 ;1.5 2.3 1.7; 1.8

. 02-08-96 686 0.2 i 1.1 ; 1.1 3.3 i 1.4 ; 1.5 3.5 1.8 ; 1.9 t

. 02 15-96 827 0.7 i 1.2;1.2 2.3 i 1.4;1.4 3.0 1.8 ; 1.9 02-22-96 891 0.411.1;1.1 2.5 i 1.3;1.4 2.9 1.7;1.8 02-29-96 1011 0.2 i 0.8 ; 0.8 3.3 i 1.5 ; 1.6 3.5 i 1.8 ; 1.8 03-07 96 1202 0.1 i 1.3; 1.3 3.3 i 1.6 ; 1.6 3.4 2.0;2.1 l

f 03 14-96 1392

-0.8 i 1.2 ; 1.2 3.5 1.6 ; 1.7 2.7 2.0 ; 2.0 03-21-96 1540

-0.2 i 1.2: 1.2 2.0 i 1.5 ; 1.5 1.9 1.9 ; 1.9

{

03-28-96 1712

-0.7 i 1.2 ; 1.2 1.3 i 1.4;1.4 0.6 1.8 ; 1.9 f

1st Qtr. meani s.d.

-0.1 t 0.5 2.7i 0.7 2.6 i 0.9 l

i 04-04 ZCW-1923 0.3 i 1.3 ; 1.3 1.9 i 1.4 ; 1.5 2.2 i 1.9 ; 2.0 04 11-96 2097

-0.5 i 1.2 ; 1.2 2.3i1.5;1.5 1.8 1.9 ; 1.9 l

t 04-18-96 2340 0.6 i 1.3; 1.3 3.011.7;1.8 3.612.2;2.2 04-25-96 2478

-1.0 i 1.2 ; 1.2 1.8 '1.7 ; 1.7 0.8 2.0 ; 2.1 l

05-02-96 2766

-0.111.3 1.3 2.711.7;1.8 2.6 i 2.1 ; 2.2 l

05-09-96 2992

-0.911.2;1.2 1.7 i 1.4 ; 1.4 0.8 t 1.9 ; 1.9 l

05-16 96 3124

-0.4 i 1.2 ; 1.2 1.8 i 1.4 ; 1.4 1.3 i 1.8 ; 1.9 05-23-96 33 %

-0.911.1;1.2 1 '. i 1.4 ; 1.4 0.4 i 1.8 ; 1.8 05-30 3470

-0.7 i 1.2 ; 1.2 2.0 i 1.4 ; 1.5 1.3 1.8 ; 1.9 06-06-96 3663 0.5 i 1.3:1.3 2.1 i 1.4;1.5 2.6 i 1.9 ; 1.9 06-13-%.

3802

-0.2 i 1.1 ; 1.1 1.9 1.5 ; 1.5 1.7 i 1.8; 1.9 06-20 3948 0.010.0;1.0 1.8 1.5;1.5 1.8 1 1.5; 1.8 i

l

'06-27-96 41 %

0.5 i 1.2; 1.2 1.4 t 1.3 ; 1.3 1.9

  • 1.7 ; 1.8 2nd Qtr. meani s.d.

-0.2 i 0.6 2.0 1 0.5 1.8 0.9

- i

' I l

s 10 2 rM maw A-.-

a

-*+w--

+w

--n

-+-t

ZION Table 10.

Cooling Water Collection:

Weekly Required LLD: 4 pCi/L

(,

Units:

pCi/L i

Gross Beta Date Suspended Dissolved Total Collected Lab Code Solids Solids 17esidue Z-23N Unit 2 Discharge 07-04-96 ZCW-4391

-0.0 i 1.1 ; 1.1 2.2 1.4 ; 1.4 2.2 i 1.8 ; 1.8 07-11-96 4687 0.5 i 1.1 ; 1.1 2.1 1.0 ; 1.1 2.6 i 1.5 ; 1.6 07-18-96 4841 0.611.2;1.2 0.6 1.3;1.3 1.2 1.8 ; 1.8 07 25-96 4976

-0A i 0.8 ; 0.8 2.0 i 1.3 ; 1.3 16i1.5;1.6 08-01-96 5222

-0.2 i 0.8 ; 0.8 1.7 i 1.3 ; 1.3 1.5 i 1.5 ; 1.5 08-08-96 5403

-0.5 i 0.8 ; 0.8 1.3 i 1.3 ; 1.3 0.8 i 1.5 ; 1.5 08-15-96 5615

-0.0 i 0.9 ; 0.9 2.011.3;1.3 2.0 i 1.6 ; 1.6 08-22-96 5780 1.4 i 1.2 ; 1.2 1.5 1.3 ; 1.3 2.911.8;1.8 08-29-96 5965

-0.6 i 1.0 ; 1.0 2.3 i 1.3 ; 1.4 1.7 i 1.7 ;1.7 09-05 96 6140 0.0 i 1.1;1.1 1.8 i 1.3 ; 1.3 1.811.7;1.7 09 12 96 6306 0.4 i 1.1 ; 1.1 3.2 i 1.6 ; 1.7 3.6 i 1.9 ; 2.0 09-19-96 6435 0.0i1.1;1.1 4.2 i 1.7; 1.8 4.2 2.0;2.1 (c'e 09 26-96 6625 0.8 1 1.2;1.2 3.4 i 1.6 ; 1.7 4.212.0;2.1 3rd Qtr. meant s.d.

0.210.6 2.2 1.0 2.3 i 1.1 10-05-96 ZCW-6851

-1.2 i 1.0 ; 1.0 3.0 i 1.6 ; 1.6 1.811.9;1.9 10-10-96 N S' 10-17-96 7404

-0.9 i 1.5 ; 1.5 2.4 i 1.4 ; 1.5 1.612.1;2.1 10-24-96 7628

-1.0 i 1.5 ; 1.5 3.1 i 1.4 ; 1.5 2.112.1;2.1 10-31-96 7797

-1.811.4;1.5 1.7 i 1.4 ;1.4

-0.1 i 2.0 ; 2.0 11-07-96 8091 0.0 i 0.0; 0.0 0.8 i 1.7 ; 1.7 0.8 i 1.7; 1.7 11 14-96 8304

-0.2 i 1.5 ; 1.5 2.3 1.4 ; 1.4 2.1 i 2.0 ; 2.1 11 21-96 8426

-0.1 i 1.1 ; 1.1 3.0 i 1.4 ; 1.5 2.8 i 1.8 ; 1.8 11-28-96 8614 1.0 i 1.2;1.2 2.4 i 1.4 ; 1.4 3.4 i 1.9;1.9 12-05-96 8823

-0.0 i 1.1 ; 1.1 2.3 i 1.5 ; 1.5 2.2 i 1.8 ; 1.9 12-12-96 9101 2.5 1.9 ; 1.9 3.3 i 1.8 ; 1.8 5.9 i 2.6 ; 2.6 12-19-96 9256

-1.1 i 1.6 ; 1.6 1.5 i 1.6;1.6 0.412.3;2.3 12-26-96 9381 0.211.7;1.7 1.4 1.6 ; 1.6 1.6 2.3 ; 2.3 4 th Qtr. meant s.d.

-0.2 i 1.2 2.3 i 0.8 2.0 i 1.6

  • NS = No sample; sample not available due to construction at site.

t 10- 3

ZION Table 10.

Cooling Water Collection:

Weekly Required LLD: 4 pCi/L Units:

pCi/L

' Gross Beta Date Sdspended Dissolved Total Collected Lab Code Solids Solids Residue Z-23S Unit 1 Discharge 01-04-96 ZCW-95 0.010.9;0.9 2.3 i 1.3 ; 1.3 2.3 1.6 ; 1.6 01-11 96 198

-0.3 0.9 ; 0.9 3.1 i 1.4 ; 1.5 2.8 1.7 ; 1.7 01 18-96 291 0.3 0.9 ; 0.9 11.3 1.9 ; 2.6 11.6 2.1 ; 2.7 01-25-96 357 1.2 i 1.0; 1,1 1.5 1.3 ; 1.3 2.6 1.7 ; 1.7 02-01 96 543

-0.9 i 0.9 ; 0.9 4.0 1.5 ; 1.6 3.2 1.8 ; 1.9 02-08-96 687 0.2 i 1.1 ; 1.1 4.2 i 1.5;1.6 4.4 1.5;1.6 02 15-96 828 0.1 i 1.1 ; 1.1 1.6 i 1.3 ; 1.3 1.7 1.3;1.3 02-22-96 892

-0.9 1.0 ; 1.0 2.4 1.4 ; 1.4 1.5 i 1.7 ; 1.8 02-29-96 1012

-0.1 0.8 ; 0.8 3.2 i 1.5 ; 1.6 3.0 1.7 ; 1.8 03-07-96 1203

-0.9 i 1.2 ; 1.2 3.4 i 1.6 ; 1.6 2.4 1.9 ; 2.0 03-14-96 1393

-0.6i1.21.2 2.6 1.5 ; 1.6 2.0 1.9 ; 2.0 03 21 96 1541

-0.4 i 1.2 ; 1.2 2.6 1.5 ; 1.6 2.3 i 1.9 ; 2.0 02 28-96 1713 0.4 i 1.3 ; 1.3 3.9 1.6 ; 1.7 4.3 2.0 ; 2.1 1st Qtr. meant s.d.

-0.110.6 3.5 1 2.5 3.4 2.6 04-04-96 ZCW-1924 0.5 i 1.3 ; 1.3 2.1 i 1.5 ; 1.5 2.5 1.9 ; 2.0 04-11 96 2098 0.2 i 1.3 ; 1.3 2.6 i 1.5 ; 1.5 2.7 2.0 ; 2.0 04-18-96 2341

-0.2 i 1.2 ; 1.2 1.4 i 1.6 ; 1.6 1.1 2.0 ; 2.1 04 25-96 2479

-0.2 i 1.2 ; 1.3 2.7 1.7 ; 1.7 2.5 2.1 ; 2.2 05-02-96 2767

-0.3 i 1.2 ; 1.2 2.4 i 1.7 ; 1.7 2.1 2.1 ; 2.1 05-09-96 2993

-0.8 i 1.2 ; 1.2 1.3 i 1.4 ; 1.4 0.5 1.8 ; 1.8 05-16-96 3125

-0.4 1.2;1.2 2.4 1.5 ; 1.5 2.0 1.9 ; 1.9 05-23-96 3357

-0.111.2;1.2 1.9 1.4;1.5 1.8 1.9 ; 1.9 05-30-96 3471 1.011.3;1.3 1.8.t 1.4 ; 1.4 2.8 1.9 ; 1.9 06-06-96 3664

-0.7 i 1.2 : 1.2 2.1 i 1.4 ; 1.5 1.4 1.8 ; 1.9

% 96 3803

-0.5 i 1.1; 1.1 10.9 i 2.0;2.6 10.4 2.3 ; 2.8 06-20-96 3949

-0.9 i 1.0 ; 1.1 2.5 i 1.5 ; 1.6 1.6 1.8 ; 1.9 06-27-9ti 4197 0.1 1 1.1;1.1 0.8 i 1.3 ; 1.3 0.9 1.7 ; 1.7 2nd Qtr. meant s.d.

-0.2 0.5 2.7 1 2.5 7.5 2.5 iO-4

i ZION '

Table 10.

Cooling Water i

Collection:

Weekly Required LLD: 4 pC1/L

{

Units:

pCi/L Gross Beta Date Suspended Dissolved Total I

Collected

' Lab Code Solids Solids Residue i

Z-23S Unit 1 Discharae j

07 %

ZCW-4392 0.5 i1.2; 1.2 2.0 i 1.4; 1.4 2.5 i 1.8 ; 1.8

-l 07-11-96 4688 0.5

  • 1.1 ; 1.1 2.3 1.0;1.1 2.8 i 1.6 ; 1.6 l

07-18-96 4842 0.5 i1.1;1.2 0.4 i1.3 ; 1.3

~ 1.0 i 1.7 ; 1.7 07 25-96 4977

-0.6 i 1.1 ; 1.2 1.4 i 1.3 ; 1.3 0.811.7;1.7 08-01 96 5223 0.9 i1.1 ; 1.2 1.0 i 1.2; 1.2 1.9 i 1.7; 1.7

, 08-96 5404

. 0.0 i 1.1 ; 1.1 1.8 i 1.3 ; 1.3 1.8 i 1.7 ; 1.7 1

08-15-96 5616

-0.5i1.1;1.1 1.9 i 1.3 ; 1.3 1.4 i 1.7 ; 1.7 08-22-96 5781 0.1 i1.1;1.1 2.0 i 1.3;1.4 2.1 i 1.7; 1.7 q

08-29-96 5966

-0.2 1.1;1.1 2.8 t 1.4 ; 1.4 2.5

  • 1.7;1.8 09-05-96 6141 0.5 i 1.1; 1.1 2.5
  • 1.4 ; 1.4 3.0 i 1.8 ; 1.8 09 %

6307 0.9 i1.3 ; 1.3 1.6 i 1.4 ; 1.4 2.5 i 1.9 ; 1.9

+

09-19-96

.'6434 0.1 i1.1; 1.1 3.2 i 1.6 ;1.7 3.4 i 1.9 ; 2.0 09 26 96 6624

-0.5 i 1.1 ; 1.1 1.6 i 1.1 ; 1.1 1.2 i 1.5; 1.5 f[w, 3rd Qtr. meant s.d.>

0.2

  • 0.5 1.9 i 0.7 2.1 1 0.8 10-05-96 ZCW-6852

-0.2 i 1.1;1.1 1.8 i1.5 ; 1.5 1.6 i 1.8 ; 1.9 10-10-96 ZCW-7176,7 0.7 i 0.6; 0.6 2.7 i 0.7 ; 0.8 3.4 i1.0 ; 1.0 l

10-17-96 7403

-1.9 i 1.4 ; 1.5 1.3 i 1.2 1.3

-0.6 i 1.9 ; 1.9 10-24-96 7627

-1.5 i 1.5 ; 1.5 1.4 i 1.3 ; 1.3

-0.1 i 2.0 ; 2.0 10-31 96 7796

-0.0 I 1.6 ; 1.6 1.1 1.7 ; 1.7 1.0 i 2.3 ; 2.3 11-07-96 8089,90

-0.1 i 1.1 ; 1.1 1.011.2;1.2 0.9 i 1.6 ; 1.6 11-14-96 8305

-0.3 i 1.2 ; 1.2 2.5 i 1.4 ; 1.4 2.2 i 1. 8 ; 1.9 11-21-96.

8427 0.2 t 1.1 ; 1.1 1.8 i 1.4 ; 1.4 2.0 i 1.8 ; 1.8 11 28-96 8612,3

-0.3 i0.8 ; 0.8 2.3 i 1.0 ; 1.1 1.9 i 1.3 ; 1.3 12-05 96 8824 2.1 i1.3; 1.4 2.4 i1.5 ; 1.5 4.5 i 2.0 ; 2.0 j

4 12 12-96 9102

-0.7 i 1.6 ; 1.6 2.9 i1.7; 1.8 2.2 i 2.4 ; 2.4 -

12 %

9257

-2.0 i 1.5 ; 1.5

' 2.6 i 1.7 ; 1.8 0.6 i 2.3 ; 2.3 12 %

9382

-1.1 i 1.6 ; 1.6 2.1 i1.7 ; 1.7 1.012.3;2.3

{

4 th Qtr. meani s.d.

-0.4 i 1.1 2.0i 0.6 1.6 i 1.4 10-5 i

t 4'

ZION M

Table 10.

Cooling Water Collection:

Quarterly composites of weekly couections Required LLD: 200 pCi/L Units:

pCi/L 1996 Samole Descriotion and Concentration Collection Period Lab Code Tritium Z-22 (C) Unit 1 Inlet 1st Quarter ZCW-1751 207 124;127 2nd Quarter ZCW-4207 87 79; 80

-3rd Quarter ZCW-6672 229 i 89;94 4th Quarter ZCW-9441 183 i 88;91 I

Z-23N Unit 2 Discharge 1st Quarter ZCW-1752 122 i 121;122 2nd Quarter ZCW-4208 104 i 80;81 3rd Quarter ZCW-6673 284 91;99 4th Quarter ZCW-9443 313 93;102 Z-23S Unit 1 Discharge; 7-1st Quarter ZCW-1753 148 i 83;85 2nd Quarter.

ZCW-4209 140 i 81;83 3rd Quarter ZCW 6674 231 i 89;94 4th Quarter ZCW-9442 136 i 86;88 a

)

4 10 i

..