I OPERATING DATA REPORT DOCKET NO 50-255 DATE 04-09-86 COMPLETED BY PASmith TELEPHONE (616)764-8913 OPERATING STATUS NOTES 1.
Unit Name: Palisades 2.
Reporting Period:
860301-860331 3.
Licensed Thermal Power (MWt):
2530 4.
Nameplate Rating-(Gross MWe):
811.7 5.
Design Electrical Rating (Net MWe):
805 s
6.
Maximum Dependable Capacity (Gross MWe): **770 7.
Maximum Dependable Capacity (Net MWe):
- 730 8.
If Changes Occur in Capacity Ratings (Items Number 3 through 7) since last report, give reasons:
9.
Power Level to Which Restricted, if any (Net MWe):
-10.
Reasons for Restrictions, if any:
i This Month Yr-to-Date Cumulative
'11.. Hours In Reporting Period 744 2160 125,199 12.
Number of Hours Reactor Was Critical 318.4 327.3 68,627.2 13.
Reactor Reserve Shutdown Hours 14.
Hours Generator On-Line 230.9 230.9 65,189.6 15.
Unit Reserve Shutdown Hours 16.
Gross Thermal Energy Generated (MWH) 331,392 331,392 135,933,432 j'
~17.
Gross Electrical Energy Generated (MWH) 105.410 105,410 42,322,810
- 18. -Net Electrical Energy Generated (MWH) 94,508 94,508 39,835,868 19.
Unit Service Factor 31.0 10.7-52.1
- 20. Unit Availability Factor 31.0 10.7 52.1 21.
Unit Capacity Factor (Using MDC Net) 17.4 6.0
- 49.9 22._. Unit Capacity Factor (Using DER Net) 15.8 5.4 39.5
- 23. Unit Forced Outage Rate 66.2 66.2 31.6 24.
Shutdowns Scheduled Over Next Six Months (Type, Date and Duration of Each):
25.
If Shut Down at End of Report Period, Estimated Date of Start Up:
l-26.
Units in Test Status (Prior to Commercial Operation):
Forecast Achieved i
INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION
- Based on condenser backpressure
- Weighted Average (635 MWe used as MDC Net prior to October 1985) r l
OC0185-0001B-OP03 8604220235 860331 Fg l
PDR ADOCK 05000255 r
l R
- AVERAGE DAILY UNIT POWER LEVEL.
DOCKET NO 50-255 UNIT Palisades DATE 04-04-86 COMPLETED BY PASmith TELEPHONE (616)764-8913
. MONTH.
March 1986
.i j
.l' DAY AVERAGE DAILY POWER LEVEL DAY-AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net)
?
1 0
17 0
2 0
18 0
'3 67 19 0
4 160 20 0
5 242 21 0
6 335 22 0
7 338 23 0
8 1
24 0
9 0
25 18
{
10 0
26 140 11 0
27 0
l 12 0
28 412 13-0 29 737 14 0
30 745 15 0
31 742 16 0
INSTRUCTIONS:
On this format, list the average daily unit power level in MWe-Net for each
~ day in the reporting month. Compute to the nearest whole megawatt.
OC0185-0001C-0P03
1 e
DOCKET NO.
50-255 UNIT SIRmXAWS AND POWER REDUCTIONS UNIT NAME Palisades DATE 04-09-86 COMPLETED BY PASmith REPORT MON 111 March 1986 TELEP110NE (616)-764-8913 1
2 Cause & Corrective No.
Date Type Duration Reason Method of Licensee Systp Compogent (Hours)
Shuting Event Code Code Action to 3
Down Reactor Report
- Prevent Recurrence 1
851130 S
60.9 C
1 2
860304 S
0.6 B
4 Main turbine overspeed testing.
Repair PCP seals and 3
860308 F
419.1 B
1 various valves.
4 860325 F
1.1 B
4 Minor valve repair.
5 860326 F
31.4 A
3 Yet to be written --
Main generator voltage regulator problem.
1.
2.
3.
4.
5.
F: Forced Reason:
Method:
Exhibit G - Instructions Exhibit I - Same Source S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Other (Explain)
E-Operator Training & License Examination F-Administrative G-Operational Error (Explain)
H-Other (Explain)
OC0185-0001D-OP03
SUMMARY
OF OPERATING EXPERIENCE FOR MARCH 1986 The refueling outage ended on March 3 at 1255 hours0.0145 days <br />0.349 hours <br />0.00208 weeks <br />4.775275e-4 months <br /> when the unit was placed on line. On March 4 the unit was taken off line at 1041 hours0.012 days <br />0.289 hours <br />0.00172 weeks <br />3.961005e-4 months <br /> to perform main turbine overspeed testing. The unit was back on line the same day at 1117 hours0.0129 days <br />0.31 hours <br />0.00185 weeks <br />4.250185e-4 months <br />.
On March 8 the unit was taken off line at 0346 hours0.004 days <br />0.0961 hours <br />5.720899e-4 weeks <br />1.31653e-4 months <br /> to perform maintenance on various valves and primary coolant pump seals. The unit was placed back on line on March 25 at 1453 hours0.0168 days <br />0.404 hours <br />0.0024 weeks <br />5.528665e-4 months <br />.
The unit was taken off line on March 25 at 2052 hours0.0238 days <br />0.57 hours <br />0.00339 weeks <br />7.80786e-4 months <br /> to perform a min r valve repair. At 2200 hours0.0255 days <br />0.611 hours <br />0.00364 weeks <br />8.371e-4 months <br /> that same day the unit was back on line.
On March 26 at 1258 hours0.0146 days <br />0.349 hours <br />0.00208 weeks <br />4.78669e-4 months <br /> the plant tripped due to problems encountered during main generator voltage regulator testing. The unit was placed back on line on March 27 at 2025 hours0.0234 days <br />0.563 hours <br />0.00335 weeks <br />7.705125e-4 months <br /> and was at approximately 97 percent power at the end of the reporting period.
OC0185-0001E-OP03
@ Consumers Power Company Pahsades Nuclear Plant: 27780 Blue Star Memonal Heghway Covert MI 49043 April 9, 1986-US Nuclear Regulatory Comission Mail and Records Section Washington,pC20555 LICENSE REPORT OF MONTHLY OPERATING DATA DPR-20, DOCKET NO 50-255 Enclosed is a copy of the Monthly Operating Data and a Sumary of Operating Experience for the Palisades Nuclear Plant for the month of March 1986.
j p
]
Dewey VanDenBerg Reactor Engineer CC: KMHaas, Palisades GHGoralski, Palisades JGKeppler, USNRC JRSchepers, Palisades KWBerry, P24-614B RAFenech, Palisades Resident Inspector, Palisades
[
DLHackett, P11-228B l
LABrown, P21-317
[
CWBruckmann, Div of Radiological Health Services, Lansing, Michigan i
ZCCordero, Michigan Dept of Labor
[
RCallen, Michigan Public Service Comission l
Records Center, INPO, Atlanta, GA l
RWTaylor, CE, Palisades AAAlatalo, Palisades EWAnderson, Palisades i
EHKoepke, P21-319 Document Control. 950*22*35*10/L GCP86-005 OC0185-0001A-0P03
.