May 16, 1997 Ms. Irene Johnson, Acting Manager Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III 1400 Opus Place, Suite 500-Downers Grove, IL 60515

SUBJECT:

APPROVAL OF TOPICAL REPORT. EMF-96-051(P) - QUAD CITIES, UNIT 2 (TAC N0. M96213)

Dear Ms. Johnson:

11 By letter dated July 2,1996, as supplemented on February 17, 1997, Commonwealth Edison Company (Comed, the licensee) submitted a plant specific topical report, EMF-96-051(P),'" Application of the ANFB Critical Power Correlation to Coresident GE Fuel for Quad Cities Unit 2 Cycle 15," for review and approval. The topical report provided. cycle specific justification for the application of ANFB critical power correlation to'coresident General Electric. fuel in transition cores in support of Quad Cities, Unit 2, Cycle 15.

Based on the staff review, we find that the subject topical report is acceptable for Quad Cities, Cycle 15, specific application.

A copy of the related Safety Evaluation is enclosed.

i Sincerely, Original signed by Donna M. Skay for Robert M. PuTsifer, Project Manager Project Directorate III-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket No. 50-265 i

Enclosure:

Safety Evaluation EC Rf_ CENTES COPY cc w/ enc 1:

see next page DISTRIBUTION:

tDocket; File' PUBLIC PDIII-2 r/f J. Roe, JWR E. Adensam R. Capra C. Moore R. Pulsifer OGC, 015B18 ACRJ T2E26 W. Kropp, RIII L. Phillips, 08E23 h "I

.T. Harris, TLT00033 f

  • concurrence provided by memo 1

DOCUMENT NAME:

G:\\CHNTJR\\ QUAD \\QC96213.LTR dated 5/9/97; no major revisions g T3 receive a copy of this document, indce1% gox: *C" = Copy without enclosures *E' = Copy with enclosures "N" = No copy 0FFICE PM:PDIII-2. l 6

.A:M14II-2 l SRXB l

fD:PDIII-$ r /f NAME

&RPULSIFERX/W W ORE \\

LPHILLIPS*

LRCAPRA fl1 DATE 05/6/97 05/15/97 05/ /97

// '05/ /b/97~

  • ^

9705210017 970516 OFFICIAL RECORD COPY PDR ADOCK 05000265 P

PDR t

I. Johnson Quad Cities Nuclear Power Station Commonwealth Edison Company Unit Nos. I and 2

)

cc:

Michael I. Miller, Esquire Document Control Desk-Licensing Sidley and Austin Commonwealth Edison Company i

One First National Plaza 1400 Opus Place, Suite 400 Chicago, Illinois 60603 Downers Grove, Illinois 60515 i

Mr. L. William Pearce Station Manager Quad Cities Nuclear Power Station 22710 206th. Avenue North i

Cordova, Illinois 61242 U.S. Nuclear Regulatory Commission Quad Cities Resident Inspectors Office 4

22712 206th Avenue North

.Cordova, Illinois 61242 Chairman

. Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Richard J. Singer Manager - Nuclear MidAmerican Energy Company 907 Walnut Street P.O. Box 657 Des Moines, Iowa 50303 Brent E. Gale, Esq.

Vice President - Law and 3

Regulatory Affairs MidAmerican Energy Company One RiverCenter Place _

106 East Second Street P.O. Box 4350 Davenport, Iowa 52808 I

j

-