.-_

February 4, 1_997 i

e

?

Ms. Irene Johnson, Acting Manager Nuclear Regulatory Services Commonwealth Edison Company Cxecutive Towers West III 1400 Opus Place, Suite 500 Downers Grove, IL 60515 t

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION ON TOPICAL REPORT EMF-96-051(P),

" APPLICATION OF ANFB CRITICAL POWER CORRELATION TO C0 RESIDENT GE FUEL FOR QUAD CITIES UNIT 2 CYCLE 15" (TAC NO. M96213)

Dear Ms. Johnson:

By letter dated July 2,1996, Commonwealth Edison Company (Comed) transmitted a topical report EMF-96-051(P), " Application of ANFB Critical Power Correlation to Coresident GE Fuel for Quad Cities Unit 2 Cycle 15," to support Comed's second Siemens Power Corporation transition reload for Quad Cities, Unit 2, Cycle 15.

The staff has reviewed the licensee's transmittal and prepared the enclosed request for additional information (RAI).

Your response by February 20, 1997, would be needed to assure a timely staff review.

Sincerely,

/s/

3 Robert M. Pulsifer, Project Manager Project Directorate III-2 '

Division of Reactor Projer.ts'- III/IV Office of Nuclear Reactor, Regulation, Docket No. 50-265

(=

4 g

Enclosure:

RAI c

cc w/ encl:

see next page

,u Distribution:

Docket File '

PUBLIC PDIII-2 r/f JRoe, JWR EAdensam, EGAl RCapra CMoore RPulsifer 0GC, 015B18 RIngram ACRS, T2E26 Vg'3 PHiland, RIII DOCUMENT NAME:G:\\CMNTJR\\ QUAD \\QC96213.LTR To receive a copy of this document,indcateAthe box: "C" = Copy without enclosures *E" = Copy with enclosures "N" = No copy 0FFICE PM:PDIII-2, L8 VAd@MI-2 l U D:PDIII-2 lcs NAME RPULSIFE V #

MREI RCAPRA A*

,DATE 02/ <//97 02/( /97 02/ 4 /97 9702060352 970204

"ICIAL RECORD COPY PDR ADOCK 05000265 P

pon a

2 o

4 I. Johnson Quad Cities Nuclear Power Station Commonwealth Edison Company Unit Nos. I and 2 cc:

Michael I. Miller, Esquire Document Control Desk-Licensing Sidley and Austin Commonwealth Edison Company One First National Plaza 1400 Opus Place, Suite 400 Chicago, Illinois 60603 Downers Grove, Illinois 60515 Mr. L. William Pearce Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, Illinois 61242 U.S. Nuclear Regulatory Commission Quad Cities Resident Inspectors Office 22712 206th Avenue North Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Regional Administrator U.S. NRC, Region III 801 Warrenville Road i

Lisle, Illinois 60532-4351 Richard J. Singer Manager - Nuclear j

MidAmerican Energy Company 907 Walnut Street j

P.O. Box 657 Des Moines, Iowa 50303 Brent E. Gale, Esq.

Vice President - Law and Regulatory Affairs MidAmerican Energy Company One RiverCenter Place 106 East Second Street P.O. Box 4350 Davenport, Iowa 52808

)

3 4

a REQUEST FOR ADDITIONAL INFORMATION RELATING TO TOPICAL REPORT EMF-96-051(P) f COMONWEALTH EDIS0N COMPANY OUAD CITIES NUCLEAR STATION. UNIT 2 2

DOCKET NO. 50-265 i

4 1

1.

Provide the details of the development of the ANFB critical power correlation including experimental fuel database obtained from both Siemens Power Corporation (SPC) and other vendors.

l 2.

Provide justification on the applicability of the ANFB critical power correlation to those fuel designs which are not part of the existing supporting database for the ANFB correlation.

i 3.

Provide the detailed process, including criteria for rod pattern selection, to obtain the ANFB additive constants for GE9/10 fuel 1

assemblies and the resultant additive constant uncertainty in Table 1.1 of the subject reference EMF-96-051(P). Also, provide experimental data j

to substantiate that Table 1.1 is also applicable to GE10 fuel assemblies.

i

4. - Provide database for the results shown in Table 2.1.

Also, provide clarification that under what condition the results shown in Table 2.1 indicate that ANFB predictions have a conservative bias relative to GEXL for GE9 fuel, and the reason for the same standard deviation between i

j X and Y.

5.

Please clarify that the total resulting standard deviation on page 3-2 of the subject reference is based on the correct equation of the combined

)

uncertainty with respect to the request for additional information in the review of EMF-1125(P), Supplement 1, Appendix C.

6.

Provide the description of the Quad Cities, Unit 2, Cycle 15 fuel loading pattern - including the types and numbers of the fuel assemblies. Also, provide the detailed approach for this cycle-specific analysis on the minimum critical power ratio and provide the calculational procedures to generate the information in Table 5.1 - including assumptions for the control blade pattern, actual core loading, actual bundle parameters and full cycle exposure range.

ENCLOSURE L