ML20140H068
| ML20140H068 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 05/06/1997 |
| From: | Ewing E ENTERGY OPERATIONS, INC. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| Shared Package | |
| ML20140H073 | List: |
| References | |
| W3F1-97-0087, W3F1-97-87, NUDOCS 9705120324 | |
| Download: ML20140H068 (4) | |
Text
.O Ente gy operatisno,Inc.
Killona, LA 70066 Tel 504 739 6242 r
C. Ewing, til J
a Safety & Regulatory Affairs W3F1-97-0087 A4.05 PR l
May 6,1997 I
U.S. Nuclear Regulatory Commission Attn.: Document Control Desk
)
Washington, D.C. 20555
Subject:
Waterford 3 SES Docket No. 50-382 License No. NPF-38 Supplement to Technical Specification Change Request NPF-38-192 Gentlemen-I Technical Specification Change Request NPF-38-192 was submitted via letter W3F1-97-0054 on March 27,1997. Please find attached a supplement to Technical l
Specification Change Request NPF-38-192. This supplement was developed based on telephone conversations held with your staff on Thursday, April 10,1997.
Technical Specification Change Request NPF-38-192 added surveillance requirement 4.5.2.b.2 to verify the ECCS piping is full of water at least once per 31 e
days. In order to maintain consistency within the specification, we request that the wording of surveillance requirement 4.5.2.j be modified by replacing "... venting the ECCS pump casings and discharge piping high points." with "... verifying the ECCS piping is full of water."
Therefore, please make the wording change as indicated on the attached. This is purely an editorial change to maintain consistency within the specification and has no affect on the no significant hazards evaluation previously provided.
'\\
9705120324 970506 PDR ADOCK 05000382-Th \\
p PDR V\\
4 X
in
4 i
Supplement to Technical Specification Change Request NPF-38-192 W3F1-97-0087 Page 2 May 6,1997 Should you have any questions or comments concerning this request, please contact Mr. Paul Caropino at (504) 739-6692.
j i
Very truly yours, 7
k'
'J E.C! Ewing
- Director, Nuclear Safety & Regulatory Affairs ECE/DBM/ssf Attachments:
Affidavit TS Pages J
cc:
E.W. Merschoff, NRC Region IV C.P. Patel, NRC-NRR R.B. McGehee N.S. Reynolds NRC Resident inspectors Office Administrator Radiation Protection Division (State of Louisiana)
American Nuclear Insurers
UNITED STATES OF AMERICA i
NUCLEAR REGUl.ATORY COMMISSION in the matter of
)
)
Entergy Operations, Incorporated-
)
Docket No. 50-382 Waterford 3 Steam Electric Station
)
AFFIDAVIT Early Cunningham Ewing, being duly sworn, hereby deposes and says that he is Director, Nuclear Safety & Regulatory Affairs - Waterford 3 of Entergy Operations, Incorporated; that he is duly authorized to sign and file with the Nuclear Regulatory Commission the attached Supplement to Technical Specification Change Request NPF-38-192; that he is familiar with the content thereof; and that the matters set forth therein are true and correct to the best of his knowledge, information and belief.
' D
'Earlytunninghahl Ewing "
Director, Nuclear Safety & Regulatory Affairs -
Waterford 3 STATE OF LOUISIANA
)
) ss PARISH OF ST. CHARLES
)
Subscribed and sworn to before me, a Notary Public in and for the Parish and State above named this.c
' day of "'
~
.1997.
- A
/
, 7CLn,
< c AN Notary Public My Commission expires I d
l W3F1-97-0087 SUPPLEMENT TO 1
1 i
NPF-38-192
]
ATTACHMENT 1
1 J