7-v-

y_

POST OFFICE box 128, FT. MERCE, Fi On DA 33454 Trng Ltr Bk #85-120 FLORIDA POWER & LIGHT COMPANY December 18, 1985 Mr. Bruce A. Wilson, Chief Operator Licensing Section Division of Reactor Safety 101 Marietta Street, N.W.

Atlanta, GA 30323

Subject:

NRC Examination Cc:nments

Dear Mr. Wilson:

The written exams adminis'tered on December 16, 1985, had a significant number of " completion test" items (fill in the blank).

The structure of the questions was generically poor.

There should be only one blank per item with the blank at the end of the item.

Statements taken directly from texts should be avoided; statements taken out of context are often ambiguous.

It is difficult to construct completion items that have only one correct answer and are unambiguous.1 SENIOR REACTOR OPERATOR WRITTEN EXAMINATION C0lGENTS s '

Comment #1 IQuestion 5.07(B)]

Question expects student to. predict Xenon response (magnitude) from a transient condition.

Students were provided with equilibrium curves.

Reconsnendation #1 1

Increase acceptable answer to 3300 +1000 pcm/-500 pcm.

Consnent #2 IQueetion 5.07(D)

Question states that peak Xenon can be overcome and provided data indicates it cannot be overcome.

Recommendation #2 Delete question.

B6032402 B60318 PDR ADOCK 05000335 V

PDR e.

s FEOPLE. $E HVING PLOPLE

s

~

'l 9

Page 2 Mr. Bruce A. Wilson December 18, 1985 I

fl SENIOR REACTOR OPERATOR WRITTEN EXAMINATION C00MENTS (continued) 1:e 4

P - nt #3 IQuestion 5.11(C))

7 Question is double jeopardy in the sense that answer in Part "C"

is dependent on answer derived in Part "A."

i Recommendation #3 f

A. Accept answer based on actual response to Part "A."

5

~.

1 B. Additionally answer band should be widened to accept 3.2 see - 9.9 see i

based on different assumed Betas.

I Comment #4 [ Question 5.11(D)]

Question does not give sufficient information on plant systems status.

Reco e ndation #4 Accept POAH in addition to answer key answer.

Comment #5 IQuestion 5.12(B)]

s.

Question is vague in the use of the term " multiplication factor" in the stem and Option B.

Reconnendation #5 A. Accept new calculated Keff as correct (.9238).

B. Anser key incorrect due to calculational error; should read 1.005.

Comment #6 IQuestion 6.041 None.

Recommendation #6 Answer key should include either "C"

or "D"

since both will functionally accomplish the goal of the question.

.g y

Page 3 3

Mr. Bruce A. Wilson g

December 18, 1985 y

e SENIOR REACTOR OPE'RATOR WRITTEN EXAMINATION COlG4ENTS

?

(continued) s 1

Commsent #7 [ Question 6.08(A)1 None.

Recommendation #7 Answer key incomplete; it should include:

f.

1) Load Drop Anticipatory (LDA)
2) Close Intercept Valve (CIV) 3
3) DEH Turbine Trips:

a) Loss of Power b) Electrical Overspeed Comment #8 IQuestion 6.08(B)]

None.

Recommendation #8 Expand acceptable answers to include:

1) Differential Expansion
2) Bearing Temperatures Conument #9 [ Question 6.13(D)]

None.

Recoamendation #9 Answer should be Unit 1 and 2 because both units have identical HPSI pumps.

Comunent #10 [ Question 6.111(C)]

None.

Reconnendation #10 Answer should be Unit 1 and 2.

[SD 24, Figure 30)

' gj

~

1

-l

7 3

Page 4 i

Mr. Bruce A. Wilson g

December 18, 1985 e

t SENIOR REACTOR OPERATOR WRITTEN EXAMINATION.CODMENTS I

~

(continued)

I Comment #11 IQuestion 6.14(D)]

j Terminology used in question is confusing.

Unit 1 hot-leg injection is accomplished by directing LPSI discharge to SDC suction lines and hence to g*

the hot legs.

'l Recommendation #11 Accept either Unit 1 or Neither as correct answers.

j Comment #12 IQuestion 6.15(B)]

i None.

l-Recommendation #12 i

Answer key incorrect.

Tank - 675 gallons Pumps

.8 gpm (each) s.

675 gal

= 421 min = 7 hrs 1.6 gaUmin Should accept either 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or 1 day.

Reference:

Unit 2 T.S. 3.6.2.2 (pg. 3/4 6-f7)

Comment #13 IQuestion 7.101 Question tests knowledge of " Notes" in procedure.

Statement is True for Unit 2 and False for Unit 1.

Recommendation #13 l

A. Accept True or False as correct.

B. Delete question.

sg

c. r.

y 2

.}

a. -

Page 5

?,:

Mr. Bruce A. Wilson j;

December 18, 1985 7;

SENIOR REACTOR OPERATOR WRITfEM EXAMINATION C0l#ENTS (octntinued)

Cosament #14 IQuestion 7.171 None.

Recommendetton #14 1

Expand answer key to include any phraseology that implies "stop the evolution" and investigate.

f a

3 t

Comment #15 IQuestion 8.12(B)]

kI' None.

Recommendation #15

^

Acceptable answer should also be " gases coming out of solution" since steam is a vapor not a gas.

l L.

Ccuument #16 IQuestion 8.141 Question construction is vague concenring status of other unit of dual unit plant. Additionally, 2 sets of parenth'esis are confusing.

Reco u ndation #16

. A. Accept "cannot be" as answer due to status of other unit 'affecting STA responsibilities.

B. Delete question.

Comment #17 IQuestion 8.171 None.

Reconnendation #17 Answer key should not require verbatim repeat of bases numbers.

Explanation of cooldown capability to SDC entry conditions with loss of off-site power should be acceptable.

1 e.

?C);?'.

~1 + 6 l~ '

' ?

r.. - p
y,w u,

q L..,

n. s # -.

F

'~

5l Page 6 j

Mr. Bruce A. Wilson

(.

December 18, 1985

+I SENIOR REACTOR OPERATOR WRITTEN EXAMINATION C0196ENTS i

(continued) i c-nt #18 IQuestion 8.18(B)1 Question does not specify if ex-core detectors are only means of monitoring LHR.

A itee-

.dstion #18 j'

)

Accept either 100% or 885 as correct answer.

3

Reference:

T.S. 3.2.1, Surv. 4.2.1.3, Fig. 3.2.2 j

k i

REACTOR OPERATOR WRITTEN EXAMINATION C009 TENTS Comment #1 IQuestion 1.07(D)]

Question expects student to predict Xenon repsonse (magnitude) from a transient condition.

Students were provided with equilibrium curves.

Recommendation #1 Increase acceptable answer to 3300 +1000 pcm/-500 pcm.

Comment #2 IQuestion 1.15( A)1

None, e

i Recommendation #2 Answer key is incorrect.

It should be 850-970 psia.

Comment #3 IQuestion 2.021 None.

Reconmendation #3 Answer key should include either "C" or "D"

since both will functionally accomplish the goal of the questior..

~

' ' *.:;N : '. T

~ *

~.

w

.a pw., n -

y-

,x v +

.; _ ~ i,,

~ ~ ~

.,.. +

~

\\

Page 7 Mr. Bruce A. Wilson t

December 18, 1985 t,

1 REACTOR OPERATdR WRITTEN EXAMINATI(Ni C(DMENTS (continued) -

.p 1

b Comment #4 IQuestion 2.061

None, nQ s.

~

' '9 Res

r.dation #4

" ~ '~~

'" m ~

~

1 1

Clarification comments by prostor implied to examinees that 3 containment j

coolers were already running.

Therefore, we recommend that either 1 or 4 be accepted as correct since the question is word " start" not " receive start a

signal."

(

cL

+

Comment #5 IQuestion 2.09(D)]

None.

3 1

Recommendation #5 4

i Answer should be Unit 1 and 2. [SD 24, Figure 30]

j 9

Comment #6 IQuestion 2.09(F)]

s.

Terminology used in question is confusing.

Unit 1 hot-leg injection is

?

accomplished by directing LPSI discharge to SDC suction lines and hence to the hot legs.

l; Recommsendation #6 1

Accept either Unit 1 or Neither as correct answers.

Comment #7 IQuestion 2.10( A)1 None.

Recomunendation #7 Answer key incorrect on valve numbers as referenced to drawing.

Need to change 5 and 6 open to 8 and 11 open.

s a:

c y

--9 ['T:,[

h,

- ~ ' ~..

~

11

  • 1 Page 8 Mr. Bruce A. Wilson 4

December 18, 1985

~

,9;

'1 11 REACTOR OPERATE)R WRITTEN EIAMINATION C000 DENTS (continued)

Comment #8 [ Question 2.10(B)]

j None.

.I Recommendation #8 Answer key incorrect. Should be 13 and 14 open and 1 and 2 close.

e Comment #9 [ Question 2.10(C))

-4s Total dynamic head in fee.t is not a commonly used term by operators.

[

t Recommendation #9 t

Delete 2.10.C.2

{

}

Comment #10 [ Question 2.10(D)]

None.

d, Reccamieniatior #10 t

Answer key incorrect.

4l l'

Tank - 675 gallons j

Pumps

.8 gpm (each)

I 675 gal

= 421 min = 7 hrs 1.6 gaumin Should accept either'1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or 1 day.

Reference:

Unit 2 T.S. 3.6.2.2 (pg. 3/4 6-17) i o

v g.' ];

~

,,n;2

~

- x

~

>c,

~

4l 5

Page 9

$l Mr. Bruce A. Wilson y

December 18, 1985 g:

REACTOR OPERATOR WRITTEN EXAMINATION CODGENTS j

(continued)

Comment #11 fQuestion 2.12(B)1 y

Question is unclear at t.o which unit.

Proctor clarification indicated lo' ads common to both units.

This eliminates 3 possible answers from answer key leaving only 8 possible.

Question asks for 9 of 11.

Recomumendation #11 3

{

r A. Drop the following from key:

(

j 4

1) Fuel Pool Heat Exhangers ie
2) Quench Tank Cooling' Coils 5_
3) Containment Instrument Air Compressor j

!1 B. Change question to 6 of 8 instead of 9 of 11.

j'

=

Commsent #12 IQuestion 3.031 I

3 None.

1 Recommendation #1'2

~

Answer key should have A as the correct answer.

Reference:

SD-123, Rev. O, Page 10 Coassent #13 IQuestion 3.041 We feel that the inclusion of time delays in the text detracts from the intent of the question.

Additionally, answer C is correct per the reference.

Reconenendation #13 Accept answer C as correct.

1 l

6.

r_

-s 9

v _

Page 10 Mr. Bruce A. Wilson December 18, 1985 Q

t REACTOR OPERATbR WRITTEN EXAMINATION CODMENTS (oo.ntinued)

Comment #14 IQuestion 3.05( A)1

)

Question is unclear as to whether actual operating pressure or design pressure is the desired answer.

Res:

-detion #14 Accept answers in the range of 40-50# in addition to key answer.

'y 1

Comment #15 IQuestion 3.05(B)1 i

None.

Recommendation #15 I

Acceptable ansers should include a range of 10 sec. - 40 sec.

This includes the 10 sec. start time on the diesel.

Exact number would be 19 sec. from the diesel loading sequencing table.

}

t k

Comment #16 IQuestion 3.061 4

5 Question construc't is poor; there are t'oo many blanks, and it jumps back and forth between units.

[t Recommendation #16

' A, Delete the question.

B. Due to recent plant changes the following would be acceptable answers:

1 200 200 10 12 14 14 4

6 l

6 8

fission chamber fission chamber 1

4 or all 4 or all fission fission start-up start-up BF3 BF3 1

W,:rr,

' ' ' ~' '

v.-

gy: y;.97 _ 7

+.a

~- z.,. p, u e

bI Page 11 1

Mr. Bruce A. Wilson 4

December.18, 1985 a

?

REACTOR OPERATOR WRITTEN EXAMINATION C00MENTS (ogntinued).

.g Lt i

Comment #17 [ Question 3.11(A-E)]

None.

A G

s j

~ ' '

0 h

4 tion #17

~

Proctor clarification was that, "If conditions were present, would the k

indicated safeguards signal be actuated?"

Base'J on this; the answer key

}

should be as follows:

4 A) Unit I and 2

[

B) Unit I and 2 1

C) Unit 1 and 2 or Unit 2 D) Unit 2

-g E) Unit I and 2 1

Co u nt #16 (Question 3.13(B)]

None.

}

Recommendation #18 s.

4 Answer key is incorrect.

Answer should be True.

Reference:

SD-i37, Rev. 1, Page 43 Comment #19 [ Question 4.151 Question requires unaided recall of information from a table in an emergency procedure.

Reconnendation #19 Require 5 of 8 for full credit.

1 Principles of Educational and Psychological Measurement and Evaulation, (2nd Edition); Gilbert Sax; Wadsworth Publishing Co.

. ua =

z. ~ a w a n a.

-t c.. - z.....au

.....-.~.+_a,a,-

w.~ e m,

3 2',?.4+,w.;

4 ~:e. e gy,% 3.;. r e c g

t.

s

,rmg; >.- g

,.t<,-

%. %.a 7.

Page 12 Mr. Bruce A. Wilson y

December 18, 1985 r

s e

g

?>

No proprietary information was disclosed as per 10 CFR 2.790.

.j g

Sincerely,

(

[

D.A. Sag r e

Plant Ma er

.];

St. Lucie Plant l o N

Distribution P.L. Fincher I

W.C. Miller jf W.J. Waylett gi w

4 s.

y r

S

t 4

i e

o I

l

_.. _,