u e

,p' VYNpS 3.6 LIMITING CONDITIONS FOR OPERATION 4.6 SURVEILLANCE REQUIREMENTS 3.6 REACTOR COOLANT SYSTEM 4.6 REACTOR COOLANT SYSTEM Specification A.

pressure and Temperature Limitations (cont.)

5.

The reactor vessel irradiation surveillance specimens shall be removed and examined to determine changes in l

material properties in accordance with the following schedule:

pAPSULE REMOVAL YEAR 1

10 2

30 3

Standby h

The results shall be used to update Figures 3.6.2 and 3.6.3.

The removal times shall be referenced to the i

refueling outage following the year i

specified, referenced to the date of I

commercial operation.

O.,

B.

Coolant chemistry B.

Coolant chemistry ii 1.

a.

During reactor power operation, the 1.

a.

A sample of reactor coolant shall l

radiolodine concentration in the be taken at least every 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> I

reactor coolant shall not exceed and analyzed for radioactive 1.1 microcuries of I-131 dose lodines of I-131 through I-135 equivalent per gram of water, during power operation. In except as allowed in addition, when steam jet air g

Specification 3.6.B.1.b.

ejector monitors indicate an increase in radioactive gaseous effluents of 25 percent or 5000 uCi/sec, whichever is greater, 1

Amendment No. 33, 91 8603200111 860317 106 PDH ADOCK 05000271 P

PDR