NUREG-1535, Transcript of 951031 Mit Incident Investigation Team Interview of J Dwyer.Pp 1-74.W/related Info

From kanterella
(Redirected from ML20138Q349)
Jump to navigation Jump to search
Transcript of 951031 Mit Incident Investigation Team Interview of J Dwyer.Pp 1-74.W/related Info
ML20138Q349
Person / Time
Issue date: 10/31/1995
From:
NRC
To:
Shared Package
ML20007F222 List:
References
CON-NRC-388, RTR-NUREG-1535 NUDOCS 9703060359
Download: ML20138Q349 (80)


Text

- . - _ .-- _. . . - _ . . _.

..10 15-1726. ___

@fficial Transcript of Procsedings j g -NUCLEAR REGULATORY COMMISSION l

Title:

MIT: Incident investigation Team l Interview of James Dwyer  !

Docket Number: (not assigned)

Location: Rockville, Maryland O Date: Tuesday, October 31,1995 Work Order No.: NRC-388 Pages 1-74 NEAL R. GROSS AND CO., INC.

Court Repor*ers and Transcribers 1323 Rliode Island Avenue, N.W.

Washington, D.C. 20005 k (202) 234-4433

?M n8?M 1535 C

,_. PDR

l i

l ADDENDUM  ;

k '

Page Line . Correction and Reason for Correction f

l n n h ada , og _e _ g3 i

1 49 4 " A z u _3 % .$ ggj - l i

i e

i i

I l

i i

{- _

)

i 1

i

==

f

.\

ADDENDUM / ERRATA SHEET

(' Ji Eags - Ljg Correction and Reason for Correcli20 6 +

$$ NW A(T l/S+lf(1T46 AAlf W M. &

/ d .

9 l1 --+k al u -n &l M c.u uk, l

'I V u s b'LA huh 1m4kl 1Y 1 %ni a a.n L, l uka/Z_ L a str>> - ^<.whg H nunn w J - wn 1,4

'J G2 64 %8, I

a n, s m _

i

. n 15~ M-2s- C h ~bvl ed w d W *s re nod.d V

N ils C u y Lu +k d5 l t I

[~'N  % L r],teucr 4L

's M .w'<r %e

\ $

t4 5~ d ichn d e Lew(d w cAmM < m-t v{

Lv-+

la 4- to e mJ u gods d fu- ex A d <.%i i

w cLL. he lo w ,< - 4 \l a d L fw la-6-.- 29-Lo 1 J fc_m l # + 1e & 24- k v ej m d m) e %vtwom w aw uen i

u i, , O k cL.,ae w n%

\ d 0 nun -

4 Page l Date ii /GifF Signature -

i r

ii

s

/'~N ,

AD. DENDUM/ ERRATA SHEET s_'~' ./

  • Eagg Line Correction and Ref son for Correction cLA ud,ctrrver!

9 tl W ) ^ 0 u A r /0 lls Io .b w r ,-- c -m L lw em- om J.<-m-1J AwJ rc, d  %

n o.

y3 I l

l

~7 90 - 8 h AAitrrr e 99 9 wrm .e 9 '? m ,%

.q-6t-w~IlsI 97 to --rk. 24 amA. wr M

)

sacha<, p. Y 4r *

.22- d " Leo wllow cand

, s,

/ FDtc. a aumed 49 19

_.~

% C,- T A 4 a s q 1- r J , m a d < s-wL m)

-v t. c ov.c.+ u si -

cArcar d ca 0 f% ~L l$ sun A* Yi 9

Page .2 Date ll/A\

g D Signature . -

L

ADDENDUM / ERRATA SHEET

( , -.

'Asl Eggg Ling Correction and Reason for Correction . ,

W L-7 0x s4%- m ro.. m. -$L  %

lWv eLA A urtd -

A rr e r w> m_ uA ld > <>rN s4 fA lSTP .

U 5~f 2 a3*] W m ma.rdsh-H. s DInc L c n-nadanol c.) ntswL , g 9 . le rr

/

an Anr er 6.J c d c M i

l 6I at " TD ln%n" sJ % aA l Sin-b b  % ta *A AW E M tM OM* h @

\

% M nJ3 % V u '

(

6Am rrw 7)<. .l tJ ,arr,A O ,21-24 d %- Sw H 5% im & c4,s v t0 4 I 3dv Kna de it w_rAf Page ? Date II/;u/Tr Signature ri w

/%

'q,)

1 l

i 1 UNITED STATES OF AMERICA 2 + + +++

tO 3 NUCLEAR REGULATORY COMMISSION  ;

4 -. + ++++

5 INCIDENT INVESTIGATION TEAM 6 + ++++

7 INTERVIEW OF JAMES DWYER 8 + ++++ 1 9 MASSACHUSETTS INSTITUTE OF TECHNOLOGY l

10 + ++++ l l

11 TUESDAY, OCTOBER 31, 1995 l 12 + ++++

13 1:00 P.M.

14  !

I 15 INTERVIEWERS:

16 JOHN GLENN, Team Leader 4

17 ALAN L. MADISON l

18 SAMI SHERBINI i 19 GREGGORY P. GONECONTO 20 21 l

22 23 24 f 25 NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE ISLAND AVENUE, N.W.

j (208) 2344433 WASHINGTON, D.C. 20006 (202) 2344433 I

- _ _ - _ . - - _ - _ _ - _l

2 1 P-R-O-C-E-E-D-I-N-G-S I l

~ 2 (1:00 p.m.)

t 3 MR. GLENN: Okay, today is October 31st. It's 1

4 approximately 1:00 p.m. This is John Glenn.with the d 5 Incident Investigation Team for the MIT P-32 exposure.

6 This is going to be an interview with Jim Dwyer  ;

7 of Region I, who has been the team leader for an AIT at l 8 the National Institutes of Health. And we will be trying 9 to get information about that incident to see if there are 10 common lessons learned and facts that we should put 1

11 together in writing out report. j l

12 At this time, I'd like the other people who are 1

13 with the team to identify themselves. J A

(_) 14 MR. MADISON: I'm Alan Madison, Jim. I'm with 15 the --

I'm with AEOD, the Diagnostic Evaluation Incident 16 Investigation Branch. I'm on the team.

17 MR. GONECONTO: And Jim, my name is Greg 18 Goneconto. I'm a Special Agent with the NRC's Inspector 19 General's Office. And I'm sitting in with the IIT as an 20 observer.

21 MR. GLENN: And Jim, if you could just say who 22 you are and what your position is, and in particular what 23 your duties were with respect to the NIH incident.

24 MR. DWYER: Okay. I'm a Senior Health 25 Physicist in the Medical Branch, the Medical Inspection

, .NEAL R. GROSS

^

COURT REPORTERS AND TRANSCRISERS

- 1323 MHOOE ISLAND AVENUE. N.W.

(202) 2344433 WASHINGTON, O C. 20006 (202) 2344 433

3 i Branch, here in Region I. And I was conducting a routine i

2 inspection at NIH, leading a routine inspection on the 3 week of June 26th through the 30th.

4 -

And on the morning of June 30th, we had the --

5 the incident was made aware to us and had been identified 6 the previous evening to the Radiation and Safety Branch.

7 We quickly rolled over into an investigation, 8 into an incident investigation mode. We exited form the 9 routine inspection that afternoon, and followed that up 10 with an entrance for an AIT.

11 And I've been the AIT team leader, along with 12 Donna-Beth Howe. Sadhar Lohdi was involved initially, but i 13 then left the team. Jerry 'tenna has been working

(' 14 separately from the AIT. However, he is a team member, 15 and he's been working with the Office of Investigations, 16 the NIH Police Department and the FBI on the case.

17 And Susan Shankman is the team manager. i l

18 MR. GLENN: Okay. And I'll just mention that l

19 Sami Sherbini is on the team and may join us later.

20 MR. DWYER: Okay. Is Betsy there?

21 MR. GLENN: No, she removed herself from the 22 interview since she's a Region I employee. So she's not 23 here.

24 MR. DWYER: Okay.

km 25 MR. GLENN: You've given us a little bit of the NEAL R. GFN3SS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(2010 234 4433 WASHINGTON, D.C. 20006 (202) 2344433

1 4 )

i 1 narrative already of how the incident occurred. I was s 2 wondering if you could just go through a little bit of the 3 facts surrounding the case: who was exposed, what they l l

4 were exposed to, when they were exposed, this kind of l l

5 thing.

I 6 And then we can ask our -- oh, I'm being i 7 reminded -- I forgot to tell you something. I did mention 8 to you before we started that this would be transcribed.

9 We do that with the IIT for two reasons: 1) it means we 10 don't have to take notes when we're asking questions and 11 listening to answers; 2) it gives us a record that we can 12 refer to as we write our report.

13 You will be given an opportunity to take a look l O

- 14 at the transcript and make any corrections on an errata i 15 sheet. And we'll make arrangements to get, you know, a i

16 copy of the transcript to you so that you can make those 17 comments.

18 And we'll send you a copy of a handout we have i 19 that explains how to do the corrections and how to contact 20 us and that sort of thing.

21 MR. DWYER: Okay.

22 MR. GLENN: Okay. Now, we're getting back to 23 the narrative. If you could tell us just a little bit 24 about the facts of the case so that we all start with a i 25

%_/ . common knowledge, and then maybe we'll ask you some l NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS IJ23 RHODE ISLAND AVENUE. N.W.

(ace)2 M WASHINGTON. D.C. 20006 (202) 2 % 4433

5 1 questions that are particularly related to our charter.

es 2 MR. DWYER: Okay. I'll jump around, I think in

.V 3 chronological terms, and that's where I'll go. But let me 4 start from where my chronology began. And that was, as I 5 said, on June 30th, arriving with a couple of team 6 members, a routine inspection.

7 They were on their way out to complete some 8 items that were left on the inspection. I got there 9 around eight o' clock or so after having a team meeting in t

10 the morning in the hotel.

11 And the RSO -- actually I thought that somebody 12 on the staff had died because there were so many.long 13 faces. And they pulled me into *he Regional Safety b \' 14 officer's office and he informed me that the previous i 1

15 evening at about six o' clock they were made aware of a l 16 contamination incident that they had responded to.

l 17 And, you know, they then were starting to fill f l

18 me in on what had transpired.

19 Apparently what had occurred, there's a husband 20 and wife team of researchers from Mainland China who have 21 been working at NIH since 19 -- since August of 1994.

22 They have been doing research with mostly low energy beta 23 emitters, occasionally some P-32.

24 And they were doing PCR experiments, basically 25 using nucleotides. And the -- most of the time, they NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHOOE 18 LAND AVENUE. N.W.

(202) 234-4433 WASHINGTON D.C. 20006 (202) 234-4433

6 1 would be using in the order of 2 microcuries up to 2 sometimes_20 microcuries in their experiments.

3 The experiments were fairly far between. At t

4 one time, they used some sulphur 35. And they moved away j 5 from that because of the volatility problems, the 6 contamination problems that were reported.

7 They used some P-32 originally. They 8 evenmaally moved into P-33.

. 9 I'm at a disadvantage as far as what happened i

10 in the laboratory from March 20th on. I did look at their 11 lab notebooks, and both of their lab notebooks stopped  :

12 documenting what was going on in the laboratory as of mid-  !

i 13 March. ]

O 14 I reported that to OI, and they apparently have 15 followed up on that and have identified some additional 16 record keeping of what was going on in the laboratory. ,

I 17 But I haven't been privy to that information right now. I 18 I don't know what difficulties you had at MIT.

19 But because this is an ongoing event when we were there, I l

20 was, and the team was, precluded from speaking with either 21 the two principals, the husband and the wife, the pregnant 22 researcher or her husband, or the individual authorized j 23 user who they're alleging had something to do with this 24 contamination. l I

f T 25 MR. GLENN: Yes. Jim, just let me interrupt NEAL R. GROSS  !

count nEponTEas ao ramscnieEns l

1323 nH00E ISLAND AVENUE, N W.

(2(e) 234 4433 WASH 6NGTON D.C. 20006 (202) 2344433

_.-' ~ - ~ ~ ~ -~ ' ~ ^-

'r l

L 7 l

1 you there, because that is a major difference between the 7s 2 two investigations because we had considerable access to i- 3 the exposed individual and interviewed him three times'for

. 4 a couple of hours each time.

5 , Whose decision was it that you didn't have 6 access? Was this because of -- was this FBI, OI?

? MR. DWYER: It was a -- because of the 8 ' investigation going on and the concern by OI and the FBI -

9 - the FBI was not involved in this case initially as much 10 as they were after June 17th -- July 17th, rather.

11 But OI and the NIH police were concerned that 12 we might compromise the investigation. So~that was pretty 13 much accepted by the NMSS Region I, you know, the AIT as

( .

\v 14 something we would try and live with then. I i

15 Let me correct one thing. When I said se were

)

16 precluded from speaking with them, we did have one l 17 opportunity to speak with the pregnant researcher and her 18 husband. And that was in, I believe, the third or the I

19 fourth week in July.

20 And however, during that interview, the -- can 21 I use their names? I feel silly not using their names 22 because it's all over the press.

23 MR. MADISON: Yes, we'll have to excise the 24 transcript, whatever is easier for you, Jim.

O

'\~) 25 MR. DWYER: I'll try not to. But if I do, I NEAL R. GROSS COURT REPORTERS AND TRANSORtBERS 1323 RHODE ISLAND AVENUE, N.W.

(202) 2344 433 WASHINGTON, D.C. 20006 (202) 2344433

8 1 won't get any heartburn. Dr. X and Dr. Y were instructed

,_ 2 not to address anything having to do with the

~

3 investigation during our interview, and we were instructed 4 not to ask any questions.

5 And Jerry Kenna from OI sat in on that 6 interview with the express purpose of making sure that 7 neither one of us crossed the line.

8 So what we did was we asked questions about, 9 you know, about their work at NIH up until the event 10 occurred and then just some very cursory ideas about what 11 had occurred the night that the contamination was 12 identified.

l l

13 The following week, we had an opportunity to  ;

C:) i 14 speak with the authorized user, the Dr. Weinstein about --

i 15 from his perspective. And we were not put any -- there l l

16 were not any constraints put on us as to what questions we 17 asked.

18 And my understanding was that that had 19 something to do with, you know, the legal status of this l

20 interview. OI and the FBI could not tell us what j 21 questions to ask.

22 You know, they were not going to participate.

23 And I think if they -- something about since that was the 24 case, that they could use any information that we got in D

-(_) 25 the case. Whereas if it was contributed by FBI -- I don't NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHOOE ISLAND AVENUE, N.W.

(202) 2364433 WASH 8NGTON. D.C. 20006 (202) 2344433

-. _=.

-. - = . .- -

9 1 pretend to understand all the legalities.

2 But there was some -- you know, some legal 3 slight of hand going on there. So they weren't too 4 concerned about our interview with Dr. Weinstein. And he I

5 didn't come with an attorney, and we asked pretty much 1

6 whatever questions we wanted. l 7 Otherwise, our information has come entirely --

l 8 at least as far as the events, has come entirely from what 9 the Radiation Safety Branch was able to learn the night of l 10 the incident prior to the police becoming involved in it.

1 11 Because as soon as the police became involved

! 12 in it, they also were precluded from discussing anything 4

l 13 with the researchers or with the authorized user.

14 MR. GLENN: Okay. So you've really been l

15 precluded from any direct interaction questioning l

16 regarding the events of the day that it was detected? l 17 MR. DWYLR: Right. And now, what I'll tell you 18 now as far as the chronology of those events, come from, 19 you know, the HPs who responded to the incident and that

20 type of thing.

!' 21 And you know, what I can -- and also the 22 information that was provided by the researchers when we i

23 had the interview with them. And the recent information 24 was provided by Dr. Weinstein in our interview with him.

4

['N

'\_) 25 But you know, this is a mix-mash of basically NEAL R. GFh3SS COURT REPORTERS AND TRANSCRISERS

1323 RHODE 1$ LAND AVENUE, N.W.

(20 @ 234 4 433 WASHINGTON, D.C. 20006 (202) 2344 433

10 l i

1 of what they've said. A lot of the things that were. told 1

3 2 to us were contradictory to what we had heard from the --

d 3 from the HPs, what they had been told when they were -- )

1 4 you know, when they were there on the 29th. I i

5 But our understanding, and I'll just launch 6 into this, is that Dr. Y discovered her pregnancy, I 7 believe it was in April, and at that point elected not to 8 use any radioactive materials, even though our 9 understanding is that they were not using very much.

1 10 And most of their research was -- involved cold 11 procedures. So it didn't really affect their work too 12 much to do that.

l 13 The -- you know, it gets difficult here to 14 separate what's the allegations and everything else.

15 Apparently, according to, you know, Dr. Weinstein, they 16 had developed some interesting results, some interesting 17 experimental results. And they were very hot to publish .

18 these results.

19 And even though they had only achieved this 20 success one time and they were, you know, presenting their 21 results at meetings at the -- you know, on the NIH campus.

22 And apparently all the response that they were 23 getting was that, you know, this is great, but, you know, 24 can you reproduce it?

f}

( 25 And they were not able to reproduce it. And NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE N.W.

(202) 234 4433 WASHINGTON, D.C. 20006 (202) 234 4433

.> 11 1 the Saturday.before the incident, this would have been six r 2 days before the incident, they apparently had another 3 negative result, as they say.

I 4 And they met on Sunday with Dr. Weinstein to 5 discuss that negative result. And there was some 6 agreement that they would continue work on this and to 7 iron out their problems.

8 And then in the meantime, they would proceed 9 with presenting this or submitting this work for j 10 publication with the idea that the supporting work would 11 come later 12 So Dr. Weinstein was -- took that upon himself  ;

13 to get this paper in shape for publication. Drs. Y and X

] "' 14 went back to the laboratory to work. l 15 A lot of their work was going to be done in the 16 laboratory -- in the library, rather.

l l

17 That week, I don't have my notes in front of 18 me, but they did not use material every day of the week.

19 You know, they may have used some on Monday, probably not 20 Tuesday, maybe a little bit on Wednesday.

21 But we're not talking about any large 22 quantities and we're not talking about P-32. We're 23 talking about P-33.

24 The -- let's see, on Thursday the 28th, they N- 25 said that they were at the library and returned back to NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(202) 23H433 WASHINGTON, D C. 20006 (202)234 43

-_7

! 12 L 1 the office -- to the laboratory. And Dr. Y was hungry.

2 By the way, up until a couple of months prior 1 3 to that, they were bringing their food in and storing-it 4 in a-communal refrigerator in a conference room on the 5 floor. As I said up until a' couple of months before 6 because she had developed morning sickness, and so she 7 stopped bringing food in.

8 It was only the previous Tuesday. So that 9 would have been the 27th that they resumed -- starting 10 bringing food back in from home.

11 They ate food -- they ate lunch together on the 1:1 27th. On the 28th, Dr. Y ate alone. She says that she --

13 that they went into the conference room and Dr. Weinstein l p.

U 14 and her and his associate were having a meeting in there.

15 So they quickly put the food in the microwave and left, 16 and that Dr. Weinstein later called them and said, "Come 17 in and get your food. It's ready."

18 And they took the food back, and she ate it at '

19 a table in the hall outside of the laboratory. And she 20 reported that the food was overcooked and not very 21 tasteful. And for that reason, she didn't share with her l 22 husband. She threw the remainder in the garbage there.

23 They went home and worked later that night.

24 The next day, they worked in the office. And because they

(^)

\/ 25 were going to be working late that night, they went home NEAL R. GROSS COURT REPORTERS ANO TRANSCRISERS 1323 MHOOE ISLAND AVENUE, N.W.

(20m 2344433 WASHWGTON. D C. 20006 (202) 234 4433

13 1 in the middle of the day.

-)

\_)

2 They came back around five o' clock in the 1

3 evening, and Dr. X said that he was going to just check on 4 -- he had done an experiment that was completed earlier l 1

5 that day. I l

6 And he was apparently doing a routine survey, 7 which he said he did whether he used the material or not.

8 And he detected what he called a slight signal near her 9 feet when he was checking the floor.

10 And he thought that it was her chair or her 11 coat. And then he determined that it was coming from his )

1 12 wife.

13 The -- apparently, he tried to find Dr.

' '7,)

\. 14 Weinstein, who was not in his office. The office is )

15 directly adjacent to the laboratory. And Dr. Weinstein i 16 apparently was not in the office at the moment.

1 17 And Dr. X called the 116 number, which is the '

18 emergency fire department paramedics for the -- for the i 1

19 NIH campus. They have their own fire department there.

20 Dr. Weinstein returned. They advised him of
21 tnis, and apparently the paramedics arrived shortly 22 thereafter. Dr. Weinstein commented that he thought it a l

23 bit premature that they had called the fire department l 24 paramedics because, you know, nothing had been confirmed

" (' 25 as to what the problem was.

NEAL R. GROSS COURT REPORTERS AND TRANSCRf9ERS 1323 RHOOE ISLAND AVENUE, N.W.

(202) 2364433 WASHINGTON, D.C. 20006 (202) 2344433

14 1 The paramedics notified the Radiation Safety  ;

2 Office of the emergency response number. The Deputy RSO

~

3 was at the top of the list, and he notified the Radiation 4 Safety Office.

5 Pretty much concurrently, Dr. Weinstein called 1

6 the Radiation Safety Office and there was a parallel i

7 notification made. And the Radiation Safety Office- j l

i 8 globalized to go over.

9 That was about six o' clock, as I said, on the .l 10 29th.

11 Let me think here. The radiation -- or Dr. X )

12 apparently told Dr. Weinstein that he thought that her 13 food had been poisoned because they found contamination in

.14 the refrigerator in this conference room.

15 And they took him over there and, you know, he 16 said that he thought that he found some contamination on a 17 blue bag and on a clear bag that were in this 18 refrigerator.

19 When the Radiation Safety Office staff came up, 20 there were two of them. Beth stayed with Dr. X. George

^

21 went to do surveys in the hall and to check out the 22 conference room.

23 You know, Beth determined that she was -- you 24 know, had not had a recent procedure, started doing A

kl 25 surveys and documenting the surveys, identified that it NEAL R. GROSS COURT REPORTERS AND TRANSCR18ERS 1323 RHOOE ISLAND AVENUE, N W.

(200) 2344433 WASKNGTON, D.C. 20006 (202) 2344433

15 1 was.not her clothes by having her change into a clean pair f 2 of scrubs.

( 3) ,

3 They looked for a shower, and were 4 unsuccessful. They had her' provide a urine sample. The 5 urine sample was hot. They advised the Radiation Safety 6 Office and those samples were returned to the Radiation 7 Safety Office.

8 The -- Dr. Weinstein and Dr. X went into the 9 conference room with George, the HP, and George showed 10 them that the contamination was actually a spot inside 11 there on the floor in front of the refrigerator, and 12 nothing in the refrigerator was contaminated.

13 Dr. Y was taken to Holy Cross Hospital, which 0

\'- 14 is interesting because Suburban Hospital is right outside 15 the door from Building 37, 16 I think the State of Maryland believed that 17 they took her to Holy Cross to get her out of the la neighborhood so it wouldn't be publicized.

19 But the paramedics / Radiation Safety Branch, the 20 Licensee, said that they took her there because her only 21 complaint was back pain. And being four months pregnant, 22 they -- you know, Holy Cross reportedly has, you know, a 23 neonatal unit, or at least can handle these problems 24 better in the mind of the people who made the decision fn 25 than Suburban could.

NEAL R. GROSS COURT REPORTERS AND TRANSCRI8ERS 1323 RH00E 18LANO AVENUE. N.W.

(202) 234-4433 WASHINGTON, D.C. 20006 (202) 234-4433

16 1 I don't know how valid that is, but that's the 1

f m 2 way it was. So they took her to Holy Cross. l 3 George Redman did surveys in the conference 4 room-and posted the door, did more surveys in the 5 corridors and the halls leading back to the lab, 5B18, 6 where the researchers worked, documented all of this and 7 left there around 9:00 p.m.

8 The Radiation Safety Officer went to the 9 hospital. They had instructed the paramedics to tell the l

10 emergency room to save all of her urine. The Radiation 11 Safety Officer reiterated that, brought back one blood  !

12 sample and one or two urine samples when he returned.

13 Dr. Weinstein remained in the laboratory area.

O V 14 he contacted the Radiation Safety Office and said that he 15 had found a coffee cup on the table where Dr. Y ate her 16 dinner. And in the coffee cup was a 50 cc centrifuge tube 17 with an orange cap, and that the centrifuge tube was 18 contaminated. I j 19 So the Radiation Safety Office asked him to j 20 store that away until the following day.

I 21 Let's see, the samples were measured. They 22 pulled out NUREG CR 4884 and made some preliminary 23 evaluations that she probably had an intake of about half 24 of an ALI, around 300 microcuries.

O 25 And you see, Dr. -- 1 l

NEAL R. GROSS i COURT REPORTERS AND TRANSCRISERS  !

1323 RHOOE ISLAND AVENUE, N.W.

(202) 234-4433 WASHMGTON. D C, 20006 (202) 2344433

17 l 1 MR. GLENN: Jim, I'll just comment that that's  :

,-s. 2 kind of eery, because you know, that's almost exactly the 3 same thing that happened at MIT, that the first analysis i

4 was -- once they had it in, was around 300.

5 MR. DWYER: Well talking to David Hittman and 6 Lawrence Livermore, he said that the model, the ICRP 7 model, does not account for the ramping up of the P-32 8 concentration in the urine. It appears to be a straight -

9 - you know, not a straight line, but at least a straight 10 curve.

11 Whereas if you start looking at the urine in ,

l 12 the first day or so, that really the maximum concentration i l

13 has been reached. So you'll be coming up one side of the 1

\' 14 peak and then roll over and go down.

15 So if you use those first few datapoints in the l 16 -analysis that NIH is doing, it pulls down the overall 17 average. But it doesn't fit the models. Therefore, in i

18 this case, the first two datapoints that, you know, when l l

19 ORISE looked at it and when Lawrence Livermore looked at 20 it, they're throwing out the first couple of datapoints 21 because the P-32 really had not come in sufficiently 22 enough.

23 MR. GLENN: Okay, that may be a difference 4

24 between the two because, at least preliminarily, the f

'- 25 conclusion at MIT is that the uptake occurred four or five ,

1 NEAL R. GFh3SS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE ISLAND AVENUE. N.W.

2 (20 0 2344433 WASHINGTON, D.C. 20006 (202 234-4433

18 1 days prior to the discovery of the contamination. l

, 2 MR. DWYER: Right.

L 3 MR. GLENN: So we were on the ramp down rather 4 than the ramp up.

5 MR. DWYER: Okay. So anyway, that's with 6 respect to what they had that evening. The next day, they ,

7 told us about it. They were doing inventory checks and 8 things like that on the floor.

9 The police became involved, and the police were 10 pretty upset really that they weren't called in the night 11 before because, you know, everybody who works on that 12 floor has access to the conference room.

,s, 13 And so they went back up and changed the lock l

! \

14 on the conference room door. More surveys were done in 15 the conference room. And it was -- more contamination was 16 found spread around the floor. .

l 17 It was not as significant as the contamination 18 that was in front of the refrigerator, but you might i

19 expect that someone ignored the caution tape that was on 1 20 the door and chose to enter the room and spread some j 21 contamination, both in the conference room and outside the i 22 conference room door going into the hall.

23 But one thing that was identified that was l 24 fairly significant on Friday was that when they were in

'/ 25 there doing these follow-up surveys in the conference NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RH00E ISLAND AVENUE, N.W.

(209) 236 4433 WASHINGTON, D.C. 20006 (202) 2344433

19 1 room, the HP found a paper bag that had significant f 2 contamination on it.

3 And the paper bag was sitting on this old 4 computer box in the corner, in the back corner, of the 5 room. And you know, this was brought to the attention of 6 the HP who had done the survey the night before.

7 And he said that that bag wasn't there when he 8 was there the night before. And the reason he can say 9 with great assurance was because when he covered the 10 contamination on the carpet in front of the refrigerator, 11 he used a piece of cardboard. And he took the cardboard 12 from the paper -- from the cardboard box that this paper 13 bag was sitting on.

14 So that paper bag was impounded as evidence by 15 the -- by the FBI as well as by the police, the NIH 16 police.

17 They also checked on this centrifuge tube that 18 had contamination. And they found P-32, and later some P-19 33, in the centrifuge tube.

20 The liquid was very -- just a second please.

21 (Asides.)

22 MR. DWYER: That was Jenny. So anyway, that 23 liquid was analyzed. It was originally P-32. And as the 24 P-32 decayed, it was apparent there was some P-33 in 25 there.

NEAL R. GROSS CX)URT REPORTERS AND TRAUfrCRISERS 1323 RHOOE ISLAND AVENUE, N.W.

(308) 2344433 WASHINGTON, D.C. 20006 (202) 2344433

20 1 And if memory serves me right, it was about 80

/~N 2 nanocuries per ml of liquid, and I think there was only a J 3 ml of a liquid in there. So it didn't, you know, look 4 like, unless it was rinsed out, it didn't look like that's 5 where the material came from.

6 Now both health physicists who had responded on 7 the 29th of June reported that that centrifuge tube was 8 net' on the table where Dr. Y ate when they were there 9 doing surveys, because they specifically surveyed that 10 area.

11 And as a matter of fact, one of the HPs had set 12 up a survey station at that area. And so they said with 13 pretty good assurance, personal assurance anyway, that 14 that centrifuge tube with the contamination in it was not i

15 present when they were there.

16 Let me back up a little bit. When Dr. Y was at 17 Holy Cross, they started hydration therapy, just gave her 18 an IV. The Radiation Safety Office put the -- put the 19 attending physician in touch with REACTS.

20 And REACTS had suggested some additional 21 measures that had contra-indications. And it was decided 22 that since she was pregnant and the initial P-32 result 23 looked like it was, you know, half of an ALI, that there

,_ 24 would not --

you know, that they chose not to try to do k-25 anything herculean to try and bring it down any faster.

NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE 18 LAND AVENUE, N W (208) 2344433 WASHINGTON, D.C. 20005 (202) 2344433

s 21 1 There is still some confusion about -- about 2 the sampling. As I said before, Dr. -- Bob Zoon, who is 3 the RSO, had instructed the hospital to save all of the 4 urine.

5 Apparently at one point, they -- they saved all 6 the urine, but they were -- from each void, they were 7 alliquotting out a sample and then putting the rest of it 8 in a pooled sample container.

9 There's been some allegations that that was the 1

10 suggestion by the authorized user, and that he had  ;

11 interfered with this process.

12 That's something that I think OI knows 13 something about, but the information/ communication 14 channels here have been pretty much one-way between OI.

15 When we get some information, we provide it to them, but 16 we're not getting anything back.

17 So I would expect those people to describe this 18 situation a lot better than I could at this point.

19 But see, Dr. Y was released at around 3:00 or 20 4:00 in the morning and sent home. She apparently got 21 sick in the car, resulted in some contamination that ended 22 up being cleaned up the next day by the Radiation Safety 23 Branch.

rs 24 She also apparently had severe vomiting when 25 she returned home that morning, that Friday morning.

NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE ISLANO AVENUE, N.W.

(202) 234 4433 WASHINGTON, D.C. 20006 (202) 2344433

22 1 On Friday, they came into the Radiation Safety 9 2 Branch to provide additional urine samples, and to get a V

3 whole body scan. The Licensee has a ACCUSCAN whole body 4 device.

5 They just wanted to get a baseline number and 6 possibly look at some of the clearance of the P-32 as time 7 went on.

8 She was there for quite a while, and complained 9 of some more back pain. They sent her to OMS. That's the 10 Occupational Medical Service on campus, which is like 11 their clinic.

I 12 There she was -- provided a blood sample, which 13 was pretty much something that was requested by Barry O 14 Seigal, our Medical Consultant, as a -- to get an idea of 15 whether there was any blood changes due to this l

16 contamination.  !

l 17 He didn't believe that there would be, since we 18 were still talking around 300 microcuries. But at least 19 it would knock off that high end concern.

20 MR. GLENN: Did you get results on that sample?

21 MR. DWYER: The problem being is that 22 apparently -- I forget the guy's name. He was a confidant 23 of Joe McCarthy's back in the 50's or something who went 24 to NIH at one time and died of AIDS. And NIH messed up O

V 25 and released that information.

NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLANO AVENUE, N W.

(202) 2364433 WASHINGTON D.C. 20006 (202) 234 6

1 23 1 And so they're extremely sensitive to medical  ;

I f3 2 and personal privacy, and they wouldn't provide it to me j N_) l 3 without a release from Dr. Y. And Dr. Y apparently was '

4 not authorizing any release.

5 And the way that we worked it out is that Barry ,

i 6 Siegal said that he could gat the information from OMS l 7 verbally, and that he was going to -- that he would l 8 contact OMS. ,

9 I got an unofficial response that that -- that 10 that blood profile was normal. And -- l l

11 MR. GLENN: Okay, but that's privacy 12 information?

13 MR. DWYER: That's privacy information.

O 14 MR. GLENN: Okay.

15 MR. DWYER: You see, NIH had contacted Mike 16 Stabin prior to our involvement. And he apparently has 17 collaborated with them on other issues before. And he was 18 assisting with them with what they were doing.

19 And his comment was that he wanted to see the -

20 -

you know, several more true whole body -- or true 24-21 hour urine samples. You know, that was his suggestion and 22 that he was interested in these ACCUSCAN whole body scan 23 surveys, I guess I would call them.

24 We got --

we got Barry Siegal involved. And k/ 25 Barry Siegal said that he agreed with the medical decision NEAL R. GROSS COURT REPORTERS AND TRANSCRt9ERS 1323 RHOOE ISLAND AVENUE. N.W.

(20E) 2344433 WASHINGTON. D.C. 20006 (202) 2344433

24 1 t'he night before not to do anything, you know, invasive or 2 giving a stable phosphate or anything else for this -- to 3 this woman.

4 And what he suggested was, you know, complete 5 blood profile, urine. He suggested feces. And he wanted 6 mostly to have them perform a nuclear medicine-type scan 7 on -- from this patient, from this -- from the researcher.

8 We discussed it with the Licensee and with 9 Stabin. We had great difficulty coming to conclusions 10 about what was going to occur.

l 11 It was finally agreed that they would get 24 12 hour urines; that they would run the ACCUSCAN whole body l

13 scan; that they would do blood profile; and that they O

v 14 would do the nuclear medicine-type scan. i 15 The first nuclear medicine-type scan was done 16 that evening at the Nuclear Medicine Department at NIH.

17 There was significant localization of counts in the liver 18 and spleen area, which Dr. Karaskewa, the physician, said 19 meant that the contamination was in the blood, still in 20 the blood.

21 And however, he didn't have any quantification 22 of it at that point. He was going to run some phantom 23 studies, and try and quantify what was done.

24 The Radiation Safety Office supplied her with 25 several plastic containers, and instructed her to collect NEAL R. GROSS COURT REPORTER $ AND TRANSCRt0ERS 132S RH00E ISt.AND AVENUE, N W.

(202) 2344433 WASH 8NGTON, D.C. 20006 (202) 2344433

25 1 all of her urine. She would bring urine samples in and 2 some 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> samples, which were over 7 liters in volume.

3 And I was, you know, not sure how that was 4 possible, but they checked with her making sure that 5 you're not filling this up with water, because you know, 6 we've told you to fill it. Are you sure that you're not 7 having your husband contribute this?

8 And her response was, "No, no, this is what I 9 did on Saturday. This is what I did on Sunday." So you 10 know, they were going -- using this data as if it was 11 their true 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> volumes.

12 There were follow-up whole body scans which fg 13 showed a P-32 clearance of about a week, which is close to O 14 the eight days that was expected.

15 There was a follow-up nuclear medicine scan 16 that was done seven days later. And at that time, they 17 also did a -- used a -- I believe it was a four inch 18 sodium iodide crystal from about 15 meters away from Dr. Y 19 to get an account rate, and equated that to some rough 20 phantom studies that they had done with P-32.

21 And the second nuclear medicine scan wasn't --

22 I guess indicated that it was about 420 microcuries in Dr.

23 Y at that time. That was on July sixth.

24 The first one looked to be about 860

\# 25 microcuries at the time of the scan, which was the evening NEAL R. GROSS COURT REPORTERS AND TRANSCRl8ERS

' 1323 RHOOE ISLAND AVENUE, N.W.

(2tXi) 2364433 WA8HINGTON, D.C. 20006 (202) 234 4433

26 1 of June 30th. And the nuclear medicine -- or the sodium f"'

v 2 iodide scan, I think going from memory here, was somewhere i 3 in the high 300s. And that was also on the sixth.

4 There was some discussion about the medical j 5 care that Dr. Y was getting. And she had indicated that 6 she had been working through this with her own physician, 7 and that he had reported that everything was fine.

8 I, at one time -- and I'm jumping ahead here.

9 When we finally got to interview Dr. Y, she had indicated J

10 to us that -- you know, that she had not -- she had had 11 morning sickness initially in the first trimester, but

]

12 then it stopped.

gg 13 And it was following this incident that she had

(_/ 14 started -- you know, had severe vomiting and the back pain 15 and everything else.

16 And I was concerned that maybe she was showing 17 the effects of a chemical poisoning, which I referred to 18 our -- to Barry Siegal. Barry said that that pain and the 19 vomiting could be the result of the trauma of having this 20 occur to her, that he would talk to her physician.

21 He apparently didn't have much -- much luck 22 with her physician. You know, he indicated that he had 23 not been seeing her but once early in the pregnancy, and 24 that he had gotten a phone call from her, you know, the 7_

25 previous day.

NEAL R. GROSS COURT REPORTERS AND TRANSCR88ERS 1323 RHOOE ISLAND AVENUE, N.W.

(202) 234 4433 WASHINGTON, D.C, 20006 (202) 234-4433

27 1 Barry was concerned about the medical care that 2 she was getting. And he asked if it would be okay to talk G

3 directly with NIH because the person who was in charge of 4 this, who is one of the administrators, is a medical 5 school classmate of his.

1 6 And apparently, they discussed it. And Barry J 7 came away with a feeling that NIH was doing everything 8 that was, you know, possible to solve this so that, you 9 know, I shouldn't concern myself with the medical end of 10 this.

11 Okay, as I said, I jumped ahead. The Licensee, 12 once they were in the mode of collecting urine samples and

. 13 doing these other scans for Dr. Y, started to perform O

14 urine bioassays on anyone who had access to that 15 conference room.

16 And they did find -- I guess Dr. X, the i

17 husband, had somewhere in the order of 100 dpm/ml in his 18 urine. They had a couple of other people who they 19 identified as having something greater than their LLD, 4

20 which was down around 11 dpm/ml.

21 They were really unable to explain how those 22 people -- how all those people could have -- I think we're 23 talking about three or four people -- could have been 24 contaminated by what was in the conference room.

s- 25 So they started to expand the urine sampling to NEAL R. GROSS COURT REPORTER $ AND TRAN8CRtBERS 1323 RH00E ISLAND AVENUE N.W.

(209) 234-4433 WASHINGTON, D C. 20006 (202) 234 4433

28 1 the entire fifth floor of Building 37. And chey started 2 to get more and more numbers.

3 And they finally came to a point that they 4 couldn't explain it anymore, and they started doing some 5 additional surveys on the fifth floor. And at that point, 6 they identified a cooler that was contaminated with P-32 7 internally in the reservoir.

8 There was -- you know, you could get about 9 60,000 counts on a pancake. They did some smears to 10 identify the P-32, and there was significant contamination 11 on the stainless steel surface on the inside of the 1 l

12 cooler.

13 The water itself at that point was not 14 contaminated. You know, apparently that had all washed 15 through. This was just something that had plated out.

16 There was some liquid that was contaminated 17 that was in the trap in the basin that's below the 18 spickets. And NIH realized that since that was the only 19 unmetabolized contaminant, they then undertook an 20 analysis. They were going to try a thin layer of 21 chromatography, an aspect to try and identify what the 22 form was, whether it was orthophosphate, or was it an ATP 23 or whatever?

24 And they tried to do that internally. The 25 individual at NIH that tried to do it appeared to be well NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHOOE ISLAND AVENUE, N.W.

(209) 2364433 WASHINGTON, D.C. 20006 (202) 2344433

29 1 qualified and knowledgeable about what was going on. But

(~N 2 his comment was that the material looked to be an organic.

. G 3 But most of the material travelled with the inorganic as 4 an orthophosphate.

5 And he believed that it was probably something

. 6 like waste. Also, the fact that it had been sitting at 7 room. temperature for -- whenever the contamination 8 occurred, you know, that any organic would have broken s

9 down since it's usually stored at a frozen.

10 So he couldn't do anything with that. We then 11 went to NEN, to their Analytical Chemistry Department to 12 look at it. And they analyzed the sample, and they pretty 13 much came up with the same conclusions.

.O 14 We, Region I, still has the sample here, 4 l

. 15 although the FBI laboratory is planning on looking at it.

1 1 l

16 They didn't want to analyze it because of the contaminant.

l 17 We have analyzed it here radioisotopically.

18 Initially, we saw the P-32 decay away. There l 19 was no P-33 in the sample. However, we're still getting 20 what the Licensee tells us is chemiluminescence.

21 We were a little concerned that the 22 chemiluminescence wasn't varying with temperature and 23 wasn't going away. And Jim Kottan here did some analysis, 24 did some calibrations, with a tritium standard. And he's 25 fairly well convinced that there's some minor amounts of NEAL R. GROSS COURT REPORTERS AND TRANSCRISER$

1323 RHOCE ISLAND AVENUE, N.W.

(20E) 2344433 WASHINGTON. D.C. 20006 (202) 234-4433 i

30 1 tritium in this -- in this liquid also.

2 We've asked the Licensee about that. -They've 3 sent us their reports and -- which indicate that there was 4

4 no P-33 or tritium in the sample. But we're -- they are 5 providing additional information in response to our 6 request.

7 So we don't have the final numbers in on that.

8 But we're looking at around about 50,000 dpm/ml in that --

9 in that basin sample that we were analyzing, that looks to 10 us to be tritium.

11 I feel like I've jumped around and I've missed 12 a lot. Maybe I can address more of it as you ask l l

13 questions.

14 MR. GLENN: Well, you've done quite well with a 15 relatively long narrative there. So thank you very much.

16 I guess the first issue: when will your written report be 17 ready?

18 MR. DWYER: It's in draft, and actually we're 19 giving it to the editor to look at. Basically the things 20 that are not well developed to this point are -- I've got 21 the conclusions and our assessment of their response in 22 bullet form, all the background information, security, you 23 know, waste, inventory.

24 You know, how they train and authorize users 25 and all that stuff is I'd say 95 percent complete as NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(208) 23 4 433 WASHINGTON. D.C. 20006 (202) 23H433

31 1 written, you know, subject to change.  ;

(~T 2 The chronology -- my chronology went into V

3 October. And what I was told to do was to complete it on 4 July 17th, which was, you know, once the cooler 5 contamination was identified.

6 So the current' draft of the AIT report, the ,

7 chronology only goes through July 17th. Donna-Beth is I

8 putting together the dosimetry, you'know, parts of this l 9 report.

10 We just got the Lawrence Livermore final 11 assessment on Friday. And I read it over the weekend.

12 Donna-Beth is pouring through it with a little bit more 13 detail. And she's got some questions about it.

O 14 I would expect that a completed product for the 15 editor would be in place before the end of the week, 16 assuming that nothing else occurs.

17 MR. GLENN: Do you know whether we can get a 18 copy of that?

19 MR. DWYER: As far as -- I mean, I've provided s

20 it to Carl Paperiello and Cindy Jones has a copy of it and 21 stuff. I can -- you know, I don't see any reason why I 22 couldn't provide you with a copy of the AIT report in 23 draft.

24 MR GLENN: Okay, we would appreciate that. I O 25 may have Cherie Siegel contact you so that we get it NEAL R. GFN3SS COURT REPORTERS ANO TRANSCRtSERS 1323 RHODE ISLAND AVENUE, N.W.

(208) 23M433 WASHINGTON, O.C. 20006 (202) 2344433

32 1 logged in as an official document and get it marked 2 appropriately so that we don't release, you know, pre-3 decisional information.

4 MR. MADISON: Pre-decisional information, yes.

5 MR. GLENN: Okay, let me just briefly explore 6 with you event reporting and Licensee response. It sounds 7 like in this case, in terms of event reporting, it was 8 reported within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> simply because you were there.

9 MR. DNYER: Yes, and I honestly don't believe 10 that they would have reported it had I not been there.  ;

1 11 MR. GLENN: But there's no way to know that I I 12 guess.

13 MR. DWYER: Well, there's no way to know except 14 for the fact that they'ie - they kept on saying, "You 15 know it's not reportable. You know it's not reportable."

l 16 MR. GLENN: Yes.

17 MR. DWYER: That's correct. And actually, as 18 far as the written report, they did submit the 30 day 19 report simply stating that we're reporting this because of 20 the possibility that it may exceed an ALI. And we're --

21 this is an ongoing event that your staff is aware of and 22 because they're working with us on it basically.

23 MR. GLENN: Okay. Now in terms of their 24 response, it sounds like they responded promptly. They

(

\J 25 did surveys. They did -- they took the urine samples.

NEAL R. GROSS COURT REPORTERS ANO TRANSCR18ERS 1323 RHOOE ISLAND AVENUE N W.

(209) 2344433 WASHtNGTON, D.C. 20006 (202) 234-4433

33 1 MR. DWYER: Yes, my -- one of the things that

-. s 2 we're having in the assessment and they're kind of upset v

3 about it because it's, you know, 20-20 hindsight, but they 4 -- but I kind of agree with them in one instance.

{ 5 And that is that they were operating on 6 information from Dr. Y and Dr. X that they got on day one.

~

7 And that's the only information they had.

8 Okay, Dr. Y and Dr. X said that they brought 9 all of their liquid, all their food and drink, to the 10 office with them, that they didn't drink out of any i

11 community, you know, coffee pots.

12 MR. GLENN: Oh okay.

1 13 MR. DWYER: They didn't do any of this stuff.

14 And that, you know, they said that this food was 15 contaminated, and that was the only thing that she ate 16 that he didn't eat.

17 And you know, here we had contamination, you l 18 know, no place else in the laboratory where they worked or 19 where she ate or in the hall between the laboratory and 20 the conference room except in the conference room in front 21 of the refrigerator where she stored her food.

22 That was what they were operating under, and 23 that's what they responded to.

24 And when they did their surveys up there, they fs s_ 25 surveyed everything between the conference room, the hall NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLANO AVENUE. N.W.

(204 234-4433 WASNINGTON, D.C. 20006 (202) 234-4433

34 1 in front of the conference. room, the corridor between the 2 C and D hallways, and then the D hallway -- I'm sorry, D 3 corridor down to the laboratory and the entire laboratory 4 and all the laboratories around it and didn't find 5 anything.

6 And most of these laboratories are kept pretty  !

7 cold. And most of them have hardly use in them. So l

8 there's not that much up there to see.

9 You know, this can -- so they were focusing on  ;

10 this particular incident as being the ingestion, and 11 that's all they had.

12 I felt that they were right, and it was -- I 13 thought that their initial response to this was very good.

14 I'm not sure how many of our Licensees would be capable of j l

15 doing this, except maybe MIT, which is kind of an l l

16 interesting thing.

17 We don't have a lot of sophisticated Licensees 18 who -- I mean, even the little ones who have authorization I 19 to have a millicurie of P-32, this could happen to them.

l 20 And I don't even think they have the instrumentation to 21 follow up, let alone the know-how.

22 So I felt their initial response was very good.

23 However, they focused on this one ingestion possibility 24 and rather than going and doing a very, very good survey i

A(~/ 25 of the rest of the floor and other areas.

NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(20Q 2364433 WASHINGTON, D C. 20006 (202) 234-4433

35 1 What they did, one of the -- the Director of 2 the program, the Developmental Therapeutics Program, which 3 is over the tor'of this lab, you know, he called a meeting 4 and he said that -- you know, he told us that he assigned 5 all these areas, both restricted and unrestricted areas, 6 and had people go and do surveys of these areas.

7 And then he was requiring that they do 8 continual surveys of these areas. Well, it wasn't until 9 later that we found out that he didn't consider the 10 corridors to be unrestricted areas or even part of the 11 floor, and they were outside of his realm of concern.

12 So that's why this water cooler wasn't 13 identified for essentially two weeks.

O 14 So basically, they focused on this one 15 ingestion. They were very prompt with doing the initial 16 bioassays. I mean, they expanded the scope; they got the l 17 samples in. Thel analyzed them quickly. l 18 When they expanded it to do the whole fifth 19 floor, this is prior to identification of the cooler, our 20 indications are that they fell behind in processing, 21 sometimes two or three days.

22 And it wasn't until the 13th of July, which is 23 Thursday, that they ended up putting'-- I think they 24 counted, you know, somewhere up to 100 urine samples

O

\/ 25 overnight that night, such that on Friday morning, the NEAL R. GROSS COURT REPORTERS AND TRANSCRIOERS 1323 RHOOE ISUWO AVENUE, N.W.

(209) 234-4433 WASHINGTON, D.C. 20006 (202) 2344 433

36 1 14th, they were -- thep had -- had identified something f'] 2 like 17 new positive urines or something.

V 3 And it's at that point that they've said, "All 4 right. We, you know, obviously have missed something.

5 Let's get back up there and start surveying even more."

6 So because of that focus, they didn't identify 7 the cooler. And once they expanded the bioassay program 8 to the entire fifth floor, they fell behind.

9 So if they had processed them promptly,.you 10 know, we may have -- they may have identified the cooler 11 even a couple of days sooner than they did.

l 12 MR. GLENN: Now Jim, has anyone looked at the 13 issue of whether there may have been one, two or three or 14 more episodes of contamination?

15 MR. DWYER: We're, you know, still -- you know, 16 we're talking about, you know, problems with security and L

17 things like that. But we really don't know, you know, 18 whether security had anything to do with this or whatever 19 because we don't know what the -- how it occurred.

20 I -- you know, if you ask several different 21 people, you get several different answers. Drs. X and Y 22 will tell you that she was contaminated, and that somebody 23 contaminated the cooler, either concurrently or later to 24 throw everybody off the track.

25 I don't believe that this was one event, solely NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS

. 1323 RHOOE ISLAND AVENUE, N.W.

(202) 2344433 WASH 4NGTON, D C. 20006 (202) 2344433

l 37 l 1 because -- you know, initially Drs. Y and X said that they )

2 didn't drink anything out of the cooler or any -- you ,

3 know, that they brought all their own liquids.

4 When I interviewed them the last week of July, l l

5 they told us that they did drink out of that cooler. And I 6 however, Dr. Y said she drank very little, and her husband l

7 drank like a fish out of the cooler.

8 Well, he had 100 dpm and she had, you know, l

9 somewhere up to maybe a millicurie of P-32 in her body. )

10 So I don't believe that her contamination came from the 11 water cooler.

12 You know, her contamination came separately 13 than that. So I believe there's two events.

\ 14 MR. GLENN: And you can correct me, but I think 15 I heard in your narrative that, in fact, there was a paper l l

16 bag that was found that --

17 MR. DWYER: Right.

18 MR. GLENN: -- that the surveyor swears was not 19 there when the first survey was done.

20 MR. DWYER: Right. And I also talked about the 21 centrifuge tube. And I can see where somebody might, you 22 know, in their haste if their tired or whatever, they 23 might not have seen the centrifuge tube even though they 24 said they did careful surveys of that whole tabletop.

'(^)

k_ 25 But I can't imagine that the guy ripped the top NEAL R. GROSS COURT REPORTERS ANO TRANSCR$ERS 1323 RHODE ISLAND AVENUE, N W.

(200 23 4 433 WASHWGTON, D C 20006 (202) 23 4 433

. _ __ . - . ~ .. _ .. .-

38 1 off of that box to provide shielding and protection over i 2 that spot on the floor and didn't see the bag.

r 3 So -- so yes, that bag appeared sometime after 4 nine o' clock on Friday night and before 8:30 Friday 5 morning -- I'm sorry, nine o' clock Thursday night.

i 6 MR. MADISON: Jim, can I -- let me ask did 7 their response -- was their response based upon written 8 procedures or based upon their expertise?

9 MR. DWYER: What they do is whenever they have 10 an incident, they have things like skin contamination kits 11 and spill kits and things. And they provide training to 12 their HP staff.

,,s 13 They have a very large HP staff. And most of J

(\-) 14 them -- not most of them, but a lot of them are certified.

3 15 They -- if you're an HP there, you've got your Masters in 16 Health Physics. You know, it's a fairly sophisticated 17 group.

l 18 When they -- when they have an incident, as I 19 started to say, they -- you know, they'll have one of 20 their supervisors who is managing it.

21 When they get done with the incident, they have 22 lessons learned to see how they could do better. And they 23 provide training to, you know, all of the HP staff on what 24 they did and how they did it and what they could do better

, ('S

(-) 25 on this response.

NEAL R. GFUDSS COURT REPORTERS ANO TRANSCRISERS 1323 RHODE ISLANO AVENUE. N.W.

(202) 2364433 WASHINGTON, D C. 20006 (202) 234 4433

, .. ~. - - - -

39 1 As far as do they have any specific written 2 procedures on how to respond to an incident, I didn't see 3 anything like that. I didn't ask to see anything like 4 that.

]

5 And to be honest with you, I'm not sure how 6 valuable that would be, granted -- given that you really 7 don't know what you're going to come up against. You 1

8 know, you would end up writing a, you know, procedure that l 9 would be the size of a bible, you know, to respond to 10 anything, you know, imaginable.

11 And if it's been something that's imagined, it 12 probably doesn't happened because they've taken, you know,  ;

13 steps to make sure that that type of thing is not, you 14 know, possible.

15 MR. MADISON: Let's focus down into the area 16 then for the individual researcher that finds themselves 17 contaminated or ingesting contamination. Do they 18 procedures for that?

19 MR. DWYER: Yes, they have a -- they have 20 emergency procedures that are provided to them verbally 21 and'in writing at the time when they go through training.

22 MR. MADISON: Do they address internal 23 contamination?

24 MR. DWYER: I don't believe that they do, no.

(~)

(_/ 25 No, except that, you know, if you've got something that's NEAL R. GROSS d

COURT REPORTERS AND TRANSCR$ERS 1323 RHODE ISLAND AVENUE, N.W.

(208) 236 4433 WASHINGTON, D.C. 20006 (202) 234 4433

40 1 more than a minor 6ffense, then you, you know -- if it's 2 any kind of contamination, you contact your authorized 3 user.

4 If it's more than that, then you're to contact 5 the Radiation Safety Branch for assistance.

6 MR. MADISON: Okay, that's -- that's similar to 7 MIT.

8 MR. DWYER: Yes. I mean, to give them anything 9 more is probably going to cause them to get into more 10 trouble, you know? They'll either spread it or you won't 11 be able to get an idea of what the -- an accurate quantity 12 is and you won't be able to do dose assessment.

13 You may end up breaking the skin. You may, you

\

14 know, do all kinds of things. So it's better left to the 15 experts.

16 MR. GLENN: Okay, any more questions, I guess, 17 on the emergency response? Maybe move into the dosimetry.

18 Now I guess -- how long did they take urine specimens?

t 19 How long did they track this whole body counter thing that 20 they had, and what were the results?

21 MR. DWYER: Okay, they took urine samples for -

22 -

I believe it was about a month. And Drs. X and Y 23 continually expressed displeasure with this process. They 24 -- you know, for having to collect all of her urine. And f'h k_) 25 that was something that was taken into consideration.

NEAL R. GROSS 4

CX)URT REPORTERS AND TRANSCR68ERS 1323 RHODE L8LANO AVENUE, N.W.

(20@ 2344433 WASHINGTON, O.C. 20006 (202) 2344433

41 i so they did three of the whole body scans with 2 the ACCUSCAN. They did two of the nuclear medicine scans.

3 And they selected urine samples for a menth.

4 Towards the last week or ten days, they did not 5 collect all the urine. They collected, you know, good 24 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> urine samples, you know, two or three days apart.

7 And that was what Mike Stabin recommended was 8 needed to do an accurate dose assessment here. You know, 9 he did not -- he was not a proponent of taking it out to 10 the nth degree.

11 MR. GLENN: Okay. And what were the eventual 12 projections? Were they in agreement with the initial 13 ones, or --

0 14 MR. DNYER: Well, the NIH's final assessment is 15 at 500 microcuries. That's what they believe it is. That 16 is using the initial urine data, which both ORISe and 17 Lawrence Livermore said, you know, is probably not a 18 defendable thing to do.

19 Both ORISE and Lawrence Livermore said that 20 they could reproduce, with an experimental error, the 21 result that NIH came up with if you used those two 22 datapoints.

23 NIH only used urine data to determine this 24 because, you know, that's what 4884, you know, allows for.

25 MR. GLENN: Even though they did have the whole NEAL R. GFN3SS COURT REPORTERS AND TRANSCR18ER$

1323 RHODE ISLAND AVENUE. N.W.

(200) 2344433 WASHINGTON, D.C. 20006 (202) 234-4433

I 42 1 body counting, they did --

l 2 MR. DWYER: They had whole body counting, but 3 they didn't have quantification of the whole body count.

l 4 MR. GLENN: Did they attempt to decalibrate? I l

5 MR. DWYER: No.

6 MR. GLENN: Okay.

7 MR. DWYER: Not to my knowledge. They were )

8 putting up a great battle about doing that, that it was 9 not an accurate way to do business; that, you know, here l

i s 10 you are trying to quantify broad scope and they resisted )

i 11 3C.

12 And they said, " Mike Stabin doesn't care and 13 doesn't want it." And I would talk to Mike Stabin, and O 14 Mike Stabin would say, "Well you know, it would be 15 interesting." And I would say, "Well, you know, they're 16 looking at me like I'm off in left field. And would you -

l 17 - when you're talking with them, which you're talking to i

' l 18 them several times a day, express this need?"

4 19 And he'd say, "Okay." And apparently, he 1

20 didn't care about it enough to push the issue because they 21 -- it has not been done. Although Carl had mentioned )

22 that, if need be, he would order them to do it.

23 They did not use the nuclear medicine data, 24 even though Dr. Karaskewa had done a rough quantification f}

\- 25 of that data, because they didn't have great faith in, you NEAL R. GROSS COURT REPORTERS AND TRANSCRSERS 1323 RHODE 88LANO AVENUE, N.W.

(209) 234 4433 WASHINGTON, D.C. 20006 (202) 2344 433

43 1 know, looking at broad scope basically.

2 They wanted to use the urine. And I suppose if 3 the nuclear medicine scan data has supported their 4 estimates, they probably would have embraced it. But they 5 didn't. So their estimate was based purely on that.

6 They then got the INDOS program from -- what's 7 his name? I'm losing my mind.

8 MR. SHERBINI: It's Scrable, Ken Scrable.

9 MR. DWYER: Scrable, right. And ran that --

10 their data with that program. And I'm not sure that INDOS 11 supported their estimate of around 500 microcurie ALI.

12 MR. SHERBINI: How did they get the 500 then, 13 Jim?

O 14 MR. DWYER: The 500 was based on 4884 and using 15 all the datapoints.

16 MR. SHERBINI: How did they do that? Do you 17 know?

18 MR. DWYER: How did they do that?

l 19 MR. SHERBINI: Yes. l 20 MR. DWYER: Well, if you want to get into 21 specifics, Sami, I would suggest that you interview Donna-22 Beth Howe because that was the part she was responsible 23 for.

24 MR. SHERBINI: Oh, okay, b

V 25 MR. DWYER: But my understanding is that they NEAL R. GROSS COURT REPORTERS ANO TRANSCRISERS 1323 RH00E 18LANO AVENUE, N.W.

(209) 2364433 WASHINGTON, D.C. 20006 (202) 234-4433

44 1 were going purely on 4884. They were evaluating the 24 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> urine. They were getting a concentration. They were R.;

3 inputting the IRF, and then using that to get a datapoint 4 on what the initial intake was.

5 And then they would refine it with each intake.

6 MR. SHERBINI: I see, okay.

7 MR. DWYER: All right. Okay, Oak Ridge took 8 the data that NIH had for urine, urine only, they did not 9 use any of the other data, and came up with a 720 to 810 10 microcurie intake.

11 And that was not using the first two datapoints 12 because they, you know, felt that it was not -- it didn't 13 meet the model -- match the model and that they weren't O 14 going to use them.

15 They -- you know, as I said before, they stated 16 that they could reproduce what NIH did. They just didn't 17 agree with the use of the early datapoints because --

18 MR. SHERBINI: Yes.

19 MR. DWYER: -- the P-32 was ramping up.

20 MR. GLENN: Did NIH have an answer as to why

21 they insisted on using those first two datapoints?

22 MR. DWYER: They actually placed, you know,

23 great faith in the early data. I mean, they said, you

. 24 know, you have to use everything you've got.

O k/ 25 And you know, I'm not an expert on 4884, but NEAL R. GROSS COURT REPORTERS AND TRANSCR$ERS 1323 RHOOE ISLAND AVENUE, N.W.

l (209) 2344433 WASHINGTON. D C. 20006 (202) 2344433

45 1 they, you know, said, "You know, look, it says here that

,f-~s 2 day one, this is the IRF for it, and that's what we're V 3 using. This is the procedure."

4 So you know, why should they discount this 5 datapoint, you know, and to the exclusion of others?

6 They're sitting on it, but they're quite interested in 7 what everyone else is coming up with.

8 You know, they still believe that it's 500, 9 although, you know, they've got a funny looking curve.

10 MR. GLENN: Yes, I guess I'll just pass on to 1

11 you one of the advantages we have with MIT is that they 12 did use INDOS and curve fitting. And they have extremely

,, 13 good agreement, in fact it's suspiciously good agreement, 14 between the whole body data and the urinalysis.

15 MR. DWYER: Right.

16 MR. GLENN: But they had an independent 17 consultant check it out, and we're going to be checking it

18 out too. So --

19 MR. DWYER: Right. Okay, and then we took 20 NIH's data and -- or NIH's assessment with NIH's data, 21 along with the ORISE, Mike Stabin's, assessment. And we

-22 provided that to Lawrence Livermore, okay?

23 And Lawrence Livermore used not only the urine 24 data, but they used the blood data. They used the nuclear G

J 25 medicine scan data. And they used Cindy and every other NEAL R. GROSS COURT REPOHTERS ANO TRANSCRISERS 1323 RHOOE ISLANO AVENUE, N.W.

(202) 2344433 WASHINGTON, D.C. 20006 (202) 234 4433

46 1 program under the planet and did evaluations.

l i

, 2 And we're still -- as I said, Donna-Beth is Ih

\#

3 still pouring through that. But their numbers are -- the 4 intakes are looking to be around -- probably average about 5 a millicurie.

l 6 They commented that they thought that probably 7 the best estimate of the intake would be an average of 8 what ORISE said and what Lawrence Livermore said. But 9 they weren't -- you know, there's a lot of error bars on 10 this basically.

l l

11 And the one thing that ORISE -- you know, the i

12 reason the ORISE resultant exposure to the researcher and i I

13 Lawrence Livermore's resultant exposure to the researcher 14 is higher than NIH's is because NIH equated a 600 15 microcurie uptake to a 5 REM dose, whereas ORISE and 16 Lawrence Livermore are using the 600, being, you know, a 17 regulatory number.

18 They were actually using a calculated reference lo one to do the dose calculations. So whereas the ALI 600, 20 the ALI for this pregnant researcher, I believe all was 21 calculated to be around 510 microcuries.

22 MR. GLENN: Okay.

23 MR. SHERBINI: I have a question, Jim. Why did 24 the Licensee conclude that this was not a reportable 25 incident?

- NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE ISUWO AVENUE, N.W.

(202) 234 4 433 WASHINGTON, D.C. 20006 (202) 2344 433

47 1 MR. DWYER: Well, they will still say that it's 2 less than an ALI.

i 3 MR. SHERBINI: Is that what they -- that was 4 the basis for the decision?

5 MR. DWYER: Right. And you know, I recall that 6 we used to -- the regulation used to say that if medical 7 intervention was required, then it was something that was 8 reportable.

i l

9 And you know, they said that, "Well, no. We J 10 didn't send her to the hospital for medical intervention.

11 We sent her to the hospital because she had back pain, not 12 because of her contamination," which I think is bogus.

13 But that's what they said. l O 14 And now, you know, I look at the regulations l 15 the way they are, and I believe they've changed because I 16 don't think I've missed it before. But they now say that, 17 you know, notify if hospitalization is required because of 18 external contamination, which certainly doesn't fit here 19 anymore.

20 So I -- the Licensee will say that it was 21 reportable initially. And you know, I would say that it's 22 reportable now because of -- it's appearing to be greater 23 than an ALI.

24 And they, in fact, did do the written report, 25 which will be required for a greater than an ALI exposure.

NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(209) 234 4433 WASHINGTON, D.C. 20006 (202) 2344433

48 1 MR. SHERBINI: Well, their initial estimate was 7,

2 what, 500 microcuries?

3 MR.'DWYER: Their initial-estimate was 300.

4 MR. SHERBINI: Oh, okay.

5 MR. GLENN: Okay. Now, the exposures to the 6 other individuals., what was the maximum there in terms of 7 these other 17 or so people?

8 MR. DWYER: They were in the order of about 9 five percent of hers. I don't have the numbers in front 10 of me. But there were -- besides Dr. Y, there were 26 11 other people. l 12 Five of them were not radiation workers. In 13 other words, they hadn't had training from the Radiation 14 Safety Office.

i 15 Some of them were housekeepers. They had 16 received training, so they're occupationally exposed, j 17 Five of them were like one was a secretary, one was a 18 chemist who didn't work with radioactive materials. I 19 And we submitted a TAR to Headquarters, and 20 Headquarters came back and said that these are members of 21 the public. One of those individuals got --

exceeded 100 22 millirom. I think he got 250.

23 The actual --

24 MR. GLENN: Did NIH report that?

25 MR. DWYER: NIH believes that these are all NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE ISUWO AVENUE, N.W.

(200 2344433 WASHINGTON, D.C. 20006 (202) 234 4433

49 1 occupationally exposed workers.. And we're in the process 2 of-advising them and writing them --

-O 3 MR. GLENN: Okay.

4 MR. DWYER: -- of our determination. But I 5 think the maximally exposed individual, which was a member 6 of -- which was an occupationally exposed worker, I think l

7 was around 300 millirem.

8 And these are all conservative estimates 9 assuming that the contamination occurred on the 28th of 10 June, concurrent with Dr. Y's exposure, and that that 11 individual took in that dose at that period of time.

12 Whereas if they had only contracted it a week l l

13 prior to that, it would be a lot lower. We provided those 3

(^\

(_- 14 dose estimates to Riddick.

15 And actually, their estimates were somewhat i 16 lower than what NIH did. But they all appear to be within

17 reasonable assessments, so --

i 18 MR. GLENN: Well, let me just follow up a 19 little bit on one of the statements that you made. And i

20 that was the -- you know, the seven or so liters per day 21 of urine being produced.

1 22 It turns out that that's again similar to MIT, 23 at least in the early stages. Now that dropped off later 24 for that individual when he was told not to drink so much 25 liquid.

NEAL R. GFU3SS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE ISLAND AV':NUE, N W.

(202) 2344 433 WASHINGTON D.C. 20006 (202) 2344433

50 1 Did that continue for the full month that i

2 samples were collected? i I) 3 MR. DWYER: She, you know, indicated to us that i

4 she-stopped really pushing things after a few days. I 5 would say that those seven liter jobs were, you know, i 1

6 within the first four to five days.

7 But when she -- when she decreased, she still 8 went down to like three to four liters.

9 MR. GLENN: Amazing.

l 10 MR. DWYER: You know, it was still well outside 11 the 1,100.

12 MR. GLENN: Okay. Again, that's a very similar 13 pattern that we saw with our case.

14 One last question that I have, and then see if 15 Sami has any more. But were any of the urines and the 16 samples saved, and is either Oak Ridge or Livermore 17 looking at any of the samples independently?

18 MR. DWYER: We got one of the blood samples and 19 three of the urine samples the first couple of days we 20 were there. And we sent them to ORISE.

21 And two of them were -- the blood and the 22 original urine sample, which they only collected like 15 23 milliliters or something, you know, were very small 24 samples, and ORISE said that they had problems with e .

25 volume.

NEAL R. GFU3SS COURT REPORTERS AND TRANSCRISER$

1323 RHODE ISLAND AVENUE. N.W.

(20k) 2344433 WASHINGTONc D C. 20006 (202) 234 4433

51 l l

1 And they apparently did a lot of sample 2 manipulation. And they weren't able to recover a lot of O 3 the volume in order to do the analysis.

4 Still, it was within 25 percent of what NIH 5 said that it was, i

6 The other two samples which were -- they l 7 provided a larger sample, Oak Ridge found that the numbers 8 were right on what NIH said.

9 Now we also did four urine samples that we 10 processed here in Region I. They were not done as split 11 samples. They were done as, you know -- they had an l 12 analysis and they provided us some from the sample.

13 We analyzed them, and three of them were right 14 on the money and one of them was, I think, 50 percent of 15 what NIH said it was.

16 I contacted NIH and said, "We've got a problem 17 with one of the numbers." And they submitted us -- to us 18 their analysis of what they had done for those four 19 samples.

20 And for that same sample that we had a problem 21 with, they had also had a problem with it. And they 22 commented that, you know, this particular sample had a lot 23 of bacterial growth in it. And they didn't believe that 24 it was homogenous anymore.

25 So it could not be equated to the original j NEAL R. GROSS I COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(202) N WASHINGTON D,C,20006 (202) N l

52 1 analysis was done, you know, when the sample was first 2 provided.

1

{)%

s.

3 We figured it would be smarter to get more 4

4 samples-. So we processed an additional seven urine 5 samples as split samples.

6 And the -- our numbers and NIH's numbers on the 7 splits matched very well. And on a couple of the samples,

. 8 the data, the numbers, were, you know, decay-corrected, 9 but were different than what was found originally.

10 And those particular samples, Jim Kottan noted, c

11 were -- there wac a lot of sedimentation and stuff.

12 So we feel confident that NIH, number one,

-s 13 knows how to analyze urine samples for P-32, and that the

%) 14 numbers that they reached the data -- activities that they 15 reached -- you know, the results they got were accurate.

16 I should mention that when the -- when Drs. x 17 and Y got their -- their attorneys and they engaged a 18 consultant, the consultant requested samples from these i

! 19 urines, which he provided to TMA NORCAL in Oakland, 20 California.

21 And they were going to be doing an analysis.

22 And the consultu.t - their consultant came back and said 23 that he believes that the intake was in the order of a 24 millicurie, you know, based on the analysis that he did.

7_

g 25 But the petition makes no mentic7 that there NEAL R. GROSS 4

COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE. N.W.

(202) 2344433 WASHINGTON, D.C. 20005 (202) 234 4433

53 i.

1 was anything inaccurate about the analysis that was done 2 by NIH. Again, I just think :it was how you assessed the

,0 4

j 3 dose based on these sample analyses.

i 1 4 And so we're trying to get his results.

i

} 5 There's an attempt to get the results, but we haven't done

]

I 6 that yet. And whether he'll provide them, I'm not sure. ]

7 So --

I t 8 MR. GLENN: I guess from listening to you, it 1

- 9 doesn't sound like there's really any disagreement about j 1

10 the raw numbers. It's just the translation of the numbers l 11 into the actual uptake that is at question.

12 And it appears that NIH is sort of closing

. i

13 their eyes to the comments about the early samples.

14 MR. DWYER: I think so, yes. I -- they are I

15 very stubborn. I mean, not just about the, but about l 16 everything. And I mean, I know I've been involved in l

17 incident response with NIH before, particularly in 1992.

l 4

j 18 They had an incident involving some lutetium

} 19 177 that went -- it went airborne.

20 And you know, I was working that case with 21 them. And they basically refused to use the methodology 22 referenced in Part 20 at the time, and was it Form 5 that

. 23 . talked about 7 milligrams per square centimeter and that i

24 type of thing?

'O 25 Because they said it was archaic and they were t

- NEAL R. GROSS

. 3- COURT REPORTERS ANO TRANSCRISERS

.1323 RHODE 18LANO AVENUE, N.W.

WASHINGTON, D C. 20006

) (20m 2344433 (20 0 234-4433

54 1

1 doing this other thing. And you know, for regulatory gg -2 purposes, it was very difficult to get them to change what U 3 they were doing.

4 And until new Part 20 came out and specifically 5 referenced in the regulation the 7 milligrams per square

]

6 centimeter, they weren't going to use it.

1 7 As a matter of fact, right now they are trying 8 to get an exemption in their license so they don't have to 9 use 7 milligrams for a square centimeter. So --

l 10 MR. GLENN: Well, it sounds like they accept

, I 11 science when they want to and reject science when they i

12 think the regulatory position supports those. 1 i

13 MR. DWYER: Well, you can probably say that, 14 yes.

15 MR. GLENN: Okay. Sami, any more questions on 16 dosimetry?

17 MR. SHERBINI
No.

18 MR. GLENN: Okay. Maybe we can explore a 19 little bit here the security of buildings and the control i

20 of materials. And you mentioned you're not sure it has 21 anything to do with this particular incident.

22 But I think we're in the same position at MIT, 23 that we looked at this, and we're not sure that it has 24 anything to do with the actual uptake.

'- 25 What were you findings with respect to, I guess NEAL R. GROSS COURT REPORTERS AND TRANSCR68ERS 1323 RHODE ISLAND AVENUE, N.W.

(202) 234 4433 WASHINGTON, D.C. 20006 (202) 234 4433

l 55 1 first, building security at NIH?

gg 2 MR. DWYER: Okay, if you'll let me -- let me U 3 preface this a little bit. In 1994, there was a violation 4 issued for security, and there was a CAL that was issued 5 and stuff.

6 And I actually had one of those -- the 7 inspector who would identify the security problems from 8 1994, on with me at the routine inspection in 1995.

9 And in the scope of the inspection that he did, 10 as well as another Senior Inspector here, they both came 11 back to me and said they didn't have any problems with 12 security.

13 I mean, this is -- realize this is done at the O 14 time this incident occurred, okay that this routine 15 inspection was taking place, the end of June.

16 That they had no problems with security and 17 that they thought that it was vastly improved mostly 18 because the Licensee was locking up stock vials and other 19 concentrated solutions.

20 So I don't want to discount that finding 21 because it occurred, you know, at the time that this took 22 place.

23 I mean, when the AIT took place, we went'to 24 Building -- to look at the fifth floor of Building 57.

25 One of the people on our team identified, you know, like NEAL R. GROSS COURT REPORTERS AND TRM SCRISERS

, 1323 RHODE ISLAND AVENUE, N.W.

(202) 2364433 WASHINGTON, D.C. 20006 (202) 234 4433

56 1 20 millicuries of tritium and 2 or 3 millicuries of carbon

. 2 14, which had virtually been abandoned in one of the

, 3 offices because the people had moved to another lab.

4 And you know, they thought that they had I i

1 j 5 provided -- had given it to somebody and they didn't.  ;

6 So basically, there was a security problem 7 identified with this particular lab.

1 q 8 As far as the security of the other labs, we 9 didn't have any problems with what they were doing. But 10 the investigator who was part of this, has spent many more 11 hours on the floor than I have.

12 And his comment to me occasionally during this t

13 process was, you know, i went up there early one morning,

\- 14 'and i was looking for some of the people.

15 And you know, this lab was posted and i was --

4 16 you know, there wasn't anybody in there and I was able to 17 go in there.

18 Well, which lab is it?L You know, was there l

19 anything in there? Well, i don't know. It just was j

20 posted.

21 And when I would go up there and look around, 22 and I didn't have any problems with what was going on:

23 either there was no material in the laboratory or the 24 laboratory -- the material was locked in the refrigerator 25 or whatever.

NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N W.

(202) 2344433 WASHINGTON D.C. 20006 (202) 2344433

57 1 You know, could i go up there and find a 2 laboratory that might have 250 microcuries of sulfur that 3 was unsecured? You know, I believe that I could still do 4 that, okay, on campus. But I could tell you that I could 5 do on any campus in the country, you know, and probably 6 find more than that.

7 The difference is that this laboratory -- this 8 floor, because of what had occurred, locked up pretty 9 tight after that. You know, there's been a follow-up 10 inspection that's gone back to Building 37. And they 11 pulled, I think they said 300 doors or 350 doors in 12 Building 37.

13 And they did find six laboratories that were O 14 unsecured. And you know, they found from 250 mics up to a .

15 couple millicuries of chromium in those laboratories.

16 And we've since had another CAL to deal with 17 that, and I think the CAL is fairly significant in what l 18 it's requiring.

19 But my feeling is that the security on that 20 campus is no different than it is anywhere else.

21 My major disappointment was when Bob Zoon, the 22 RSO, was notified of these findings by Doug Collins, that 23 he didn't go and lynch somebody because of, you know, the 24 heightened awareness in that building.

25 You know, you shouldn't have anything going on NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE ISLAND AVENUE. N.W.

(Itm) 2344433 WASHm0 TON, D.C. 20006 (202) 234-4433

58 1 there.

fs 2 But you know, NIH -- you know, I don't believe d 3 the security is any different than it is anyplace else.

4 If you talk about inventory control, they have very good 5 control over material coming in. You know, the material 6 has to be ordered by the authorized user. It's 7 centralized receipt.

8 It's distributed by the Radiation Safety Office 9 to certain people. They have very good control on the 10 waste end of it. Their liquid waste is not -- they don't l

11 allow sink disposals of waste. They collect every bit of 12 waste.

13 And they analyze each individual liquid waste 14 container to see what was in there.

15 Obviously for solid waste, there's not much you 16 can do about. When a material is being used in the 17 laboratory, they are required to keep some sort of l 18 inventory record.

19 The license is not specific about how they do 20 that. There's a form that's provided to them, but they 21 don't require that they use it.

22 They place more responsibility probably on the 23 authorized user for control over material, and then they 24 do documentation.

25 And you know, my only comment there was you NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLANO AVENUE. N.W.

(20E) 2364433 WASH 6NGTON, D.C. 20006 (202) 234 4433

59 1 know, you can require as much documentation you want about 2 what was used and where it was used. And you know, if 3 this is done by someone, an insider, which is what 4 everything is pointing to, then you're not going to be 5 able to find it.

6 The other problem with the record keeping is 7 that they're only estimates that they're putting down on 8 the record.

9 Most people are not accounting for decay when 10 they're taking it out. And when the sample reaches its 11 expiration date, they're certainly not pipetting it out of 12 the vial to see how much they have left.

13 You know, they just zero out the inventory and

)

You know, I don't think that's any 14 send it to waste.

15 different than what I see in most facilities.

16 I'm getting hoarse here, so --

17 MR. GLENN: No, let me ask you a specific 18 question. Did they try to determine whether they had a

. 19 discrepancy of the order of 1 millicurie in any of their i 1

20 stock solutions?

21 MR. DWYER: Yes, they did do inventories up 22 there, you know, that one on the 30th of September. They l 23 were unable to identify it. I have records --

, 24 MR. GLENN: Jim, did you misspeak? You said b

\-

, 25 30th of September. Was that --

NEAL R. GROSS COURT REPORTERS AND TRANSCRl8ERS 1323 RHOOE ISLAND AVENUE N.W.

(202) 234 4 433 . WASHINGTON, D.C. 20006 (202) 2344433

60 1 MR. DWYER: I'm sorry, 30th of June.

gS 2 MR. GLENN: Okay.

V 3 MR. DWYER: Thanks for correcting that. Yes --

4 no, they were unable to identify it. I will say that the 5 users of the orthophosphate, the one who got-the larger 6 doses, those inventories are much more accurate that the 7 ones who are using a millicurie or a half a millicurie at I 8 a time because usually the orthophosphate people are using I 9 it-all at once to label something.

10 And then, you know, 90 percent of it goes to 11 waste, and then the waste analysis looks out -- there was 12 one -- there was one sample of liquid waste that went out l 13 that was done by a researcher cleaning out her lab when 14 some of her co-researchers worked to another building.

1 15 And she didn't account for decay, and she 16 believed it was 18 millicuries of P-32 in that container. l l

17 When they analyzed it, there was more like 10. You know, 1 18 that raised some concern to me even though she said that, 19 you know, she just took what was written on the vial and 1

20 just said that was what was in there.

21 The other container that went out of that l

22 building, she thought trere was 2.5 millicuries of P-32 in 1

23 it, when actually there was like 9.8 millicuries.

24 So you know, that result there coming out of

/~%

J 25 the same laboratory looks like they didn't dump it all l

NEAL R. GROSS I COURT REPORTERS AND TRANSCRIBERS 1323 RHOOE ISt.AND AVENUE, N.W.

l (202) 2344433 WASHINGTON, D.C 20006 (202) 234 4433 l I i

- - 1

61 1 into the same container.

2 There's not, you know, a whole lot of

.\

3 opportunity on that floor for P-32 in this quantity to 4 disappear in my mind. I mean, there's only a couple of 5 large -- you know, the 10 millicurie P-32. You know, i 6 believe, based on what we've learned from the analyses 7 that were done, that we're probably looking at waste, 8 since there may have been some tritium in there, or there 9 may have been some P-33 in there.

10 MR. GLENN: That is the apparent difference 11 between the two cases because the laboratory we're looking 12 at really only received about a millicurie, 2 millicuries 13 a week, so that we're really talking the stock solution 14 being the likely source of the material. I 15 MR. DWYER: Well, the other thing is that this I

16 laboratory didn't use P-32, okay? So that's why -- I 17 mean, there was no P-32 on the inventory for this i- 18 particular lab.

1 19 You know, now you're looking at -- let's see, 20 there were 480 -- there's like 100 -- I'm sorry, there's 21 870 laboratories on that floor, okay? So the inventories

, 22 we're talking about are of all these other laboratories an 23 not of this one.

, 24 MR. GLENN: Yes.

25 MR. DWYER: So that's the major difference.

NEAL R. GROSS COURT REPORTE816 ANO TRANSCRISERS 1323 RH00E 18 LAND AVENUE, N.W.

(202) 234 4433 WASHINGTON, D C. 20006 (202) 234 4433

62!

1 And the other thing is that we don't know whether it came q 2 from another floor, or maybe even another license.

3 You know, one of the allegations that Dr. X is 4 making'is that Dr. Weinstein knows people down at 5 Frederick a the NCI facility at Fort Meade. I think it's 6 Fort Meade in Frederick.

7 And you know, that he was out there on Tuesday 8 night, and he probably brought something back with him 9 then. So you'll never be able to find it.

10 So you know, we don't know where it came from 11 or how it was done.

12 We have an idea of when it was done based on 13 the clothes that she wore and what she said she ate and i

14 when she ate, and where she vomited and when and whether 15 it was contaminated or not.

16 And also, you know, Lawrence Livermore saying 17 that those first two datapoints, you know, indicate that 18 the contamination occurred sometime shortly before this --

. 19 before you starting monitoring it.  :

20 So we're looking at the 28th as the 21 contamination. But you know, it may be the 27th or it t

22 maybe be the 29th. But I feel pretty certain about the ,

l 23 28th. j 24 MR. MADISON: Go back into the involvement with 7-4 Y 25 OI. When did the OI become involved in the investigation?

NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(202) 2344433 WASHINGTON, D.C. 20006 (202) 2344 433

63 1

~*

2 MR. DWYER: I was there on the 30th of June, 3 you know, as a continuation of the routine and moved right 4 into the AIT. The evening of June 30th, on Friday night, 5 Jerry Kenna arrived.

6 And on July first, that's Saturday, we met 7 people on the fifth floor of Building 37 to just get an 8 idea of the layout. So he was involved from the 9 beginning.

10 MR. MADISON: And then when were you 11 essentially told not to, you know, directly interview the 12 principals on this case?

- 13 MR. DWYER: Well, it was made fairly clear on U 14 Friday night, the 30th, that I guess they call our -- our l l

15 part of the inspection or something " police parlance" I 16 guess it's called and administrative investigation.

17 And whereas theirs is a different investigation 18 which supersedes ours and, you know, Jerry Kenna had 19 discussions that evening with the NIH police, as well as 20 his management. And it was a discussion about, you know, 21 they should not impede our ability to do the health and 22 safety follow-up and leave the investigation to them.

23 But that we were not to discuss any of this 24 with the Licensee.

O

\/ 25 But as far as when did somebody specifically NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHODE ISLAND AVENUE, N.W.

(202) 2344433 WASHINGTON, D.C. 20006 (202) 2344433

64 I 1 tell me, "You can't talk to them, I'm not sure that that c 2 occurred on Friday or Saturday or Monday. I can't tell i 3 you. I can't recall when it was.

4 -

MR. MADISON: Were you given a clear l 5 distinction or distinct separation as far as in your 6 charter what you were to do? Were you given a charter?

7 MR. DWYER: Yes, we have a charter. And in the 8 charter, it does say that we are to determine how it 9 occurred. But since Jerry Kenna is part of the AIT team, 10 that wa something that he was going to do.

11 And we were going to do the rest because we a

12 couldn't -- you know, we weren't investigators and we l l l 13 couldn't mix.

O 14 MR. MADISON: So you -- Jerry has remained a 15 part of the AIT? That function was not split off?

16 MR. DWYER: Right. I think if you ask him, you 17 know, he may question whether he is still on the team.

18 But to my knowledge, he had never been released. So he's 19 been pretty much solo, and I don't see him sometimes for 20 more than a week at a time.

l 21 MR. MADISON: Okay.

22 MR. GLENN: I think all the questions I have 23 been --

24 MR. MADISON
Jim, is there any lessons learned O

V 25 from your involvement right now with the Augmented NEAL R. GROSS COURT REPORTERS AND TRANSCRISER8l 1323 RHODE ISLAND AVENUE, N.W.

(202) 234 4433 WASHINGTON, D.C. 20006 (202) 234 4433

w - - . . .. ,

65 t

1 Inspection Team at NIH? Are there any things that you r's 2 would do differently?

N-3 MR. DWYER: You.know, we've been putting 4 together something here because you talk about, you know,

, 5 things I would do differently.

6 First of all, I would never put somebody with 7 my experience and qualifications in as the leader of this 8 AIT.

9 You know, I'm a 14. I've never been on an AIT 10 or an IIT. I haven't had the training that's, you know, 11 offered for that. I mean, I've had more training, but I i

12 think that I should have had, you know, more experience  !

l 13 for this to handle it. l 14 And I don't believe that all of our people on 15 the team are qualified inspectors. I don't know what --

16 specifically I'm talking about Donna-Beth Howe. I don't l l

17 know what NMSS -- you know, how they do that.

18 You know, we had one member who was on -- you 19 know, had several weeks of vacation scheduled in to go 20 back to India or something. So there wasn't anyway you 21 could get in the way of that.

22 Especially for some people, as complicated as 23 this was, you know, I felt, you know, unqualified to 24 handle this event.

O

\/ 25 MR. GLENN: Who did you have on your team?

NEAL R. GFH3SS COURT REPORTERS AND TRANSCRt9ERS 1323 RHODE 18 LAND AVENUE. N.W.

(202) 234-4433 WASHINGTON, D.C. 20006 (202) 2344433

66 1 MR. DWYER: Susan was the manager.

2 MR. GLENN: And did she -- was she dropped 3 or --

4 MR. DWYER: No, she's -- actually, you know, 5 initially I -- because I was down there, I would talk to 6 her during the afternoon at the briefing. It wasn't 7 really until after the water cooler was identified and I 8 was on my way back down that I said, you know, " Listen, 9 you need -- I need help with this." You know, you can't -

10 - I can't do this, do everything you want and still be il leading the team and negotiating with the Licensees for 12 this and handling the briefings.

13 And so, Susan came with me at that point, and O* 14 pretty much we've been working as a team on this ever 15 since.

16 MR. GLENN: Now, you mentioned that you felt 17 that the fact that you hadn't had the training handicapped 18 you. Did you feel not having a position as a supervisor 19 or a manager in the NRC made you less effective in terms 20 of getting people to cooperate?

21 MR. DWYER: Not internally, no. I think I got 22 all the cooperation that I --

23 MR. GLENN: Okay.

,, 24 MR. DWYER: -- could have asked for. It's just

25 a matter of, you know, here we started this thing, okay?

NEAL R. GFH3SS COURT REPORTERS AND TRANSCRISER8 1323 RHODE ISLAND AVENUE, N.W.

(202) 23 4 433 WASHINGTQ4, D.C. 20006 (202) 23 4 433

4 67 1 And first of all, the -- is very difficult to deal with, 2 this particular Licensee, particularly because they felt U(~T 3 we had no business being there, that this is not 4 reportable; this is internal and it's criminal and we're 5 handling it, and you're in our way.

6 So we did as much as we could to avoid getting 7 in their way.

8 There was, you know, discussion about the 9 criminality and whether we were going to compromise 10 anything. And I told the Licensee that I would not -- or i I

11 that there would not be any press release until they were 12 aware of it, and had an opportunity to comment on it.

13 And that completely -- I mean, they gave me a 14 copy of the press release after it occurred. And there's 15 some question here about what the timing was of that; 16 whether somebody at NIH was aware of it, you know, a few 17 minutes before it occurred or whatever.

18 But you know, whatever poor relationship I had 19 with the Licensee at that point became an absolutely 20 terrible relationship, and there was no dealing with them.

21 Okay, the other thing is that they' re trying to ,

l 22 deal with this incident. They're trying to deal with the 23 responses to the public. They're trying to continue to

,- 24 run their routine program.

25 And we have needs that need to be satisfied.

NEAL R. GROSS COURT REPORTERS ANO TRANSCRISERS 1323 RHODE ISLAND AVENUE. N.W.

(202) 2344433 WASHINGTON, D.C. 20006 (202) 234 4 433

y . - _ _ _ __ _ __

68 1 And a lot of those needs couldn't be done by saying, y s 2 "Okay, we're going to go interview Dr. Y and Dr. Z or Dr.

t 3 Weinstein," or something because we weren't able to do 4 that.

5 So we were dependent on them for a lot of our 6 information.

7 On the fifth of July, I mean, I spent half the 8 night talking with'the RSO trying to, you know, calm him 9 down, that we weren't taking over this investigation and 10 everything else.

11 And you know, there was some discussion here  ;

12 from Region I with the Licensee that communications would 13 go through me, to and from me.

O 14 So when Sadhar or Donna-Beth or myself, given 15 that I had an opportunity to do any real work other than, 16 you know, manage this thing, whenever we had any 17 questions, it would be presented to me and then I would 18 have to take it to the Radiation Safety Office and present 19 it to him.

20 And then he would require me to justify 21 everything that I had requested. And then they would 22 provide -- they would get the information together and 23 they would give it back to me and i would provide it back.

24 Now, you know, they were not real fast about i

A1 25 getting this information back because it was a -- you NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1333 RHOOE 18 LAND AVENUE. N.W.

(202) 2364433 WASHINGTON, D.C. 20006 (202) 2344 433

c l

69 1 know, NIH has its own bureaucracy, and they would have l

g-w) 2 somebody who would generate it and it would have to be

%)

3 reviewed and it had to be provided back to me.

4 So it was a real handcuff-type of situation. I 5 think if I, you know, experienced this before or 6 something, maybe I would be more amenable to climbing up 7 on a table land jumping up and down and screaming, yelling 8 and hollering.

9 But, you know, we were -- when we would push 10 too hard, we would hear about it. And we would basically 11 be allowed to back off of it. For instance, after the l

12 cooler problem was identified, the Licensee issued 13 questionnaires to everybody on the floor.

14 This is an attempt to make sure that everybody 15 who had contamination did, in fact, drink from the water 16 cooler, and also had like, do you know when you drank from 17 the water cooler and how much you drank from the wat er 18 cooler?

19 And that was -- those names were collected.

20 And anyway, I went to the Licensee and said, "We want to 21 see the copies of the returned responses."

22 And they would say, "Well, we haven't had a 23 chance to look at them yet." "Well, when are you going to 24 look at them?" "We're going to look at them tonight."

N- 25 "Okay, we'll be expecting it tomorrow morning."

l NEAL R. GROSS l count nEPORTERS ANO TRANSCRISERS l 1323 RHODE ISLANO AVENUE, N W.

(202) 2344433 WASHINGTON, O C. 20006 (202) 2344433 I

70 1 Well, they weren't available in the morning.

es g 2 You know, you push a little bit and then they would

.f

\-)

3 finally say, "Well, we have the results." "Well, what are 4 they?" "Well, we haven't given them to the RSO yet and, 5 you 'know, tb- vould buck back at us.

6 ,ind I would be told, you know, by -- like I 7 would say to Susan, " Susan, they're not providing them."

8 And she would say, "Oh, you need to give them a couple of 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> or something. Let's -- you know, we're pushing too lo hard." We're pushing too hard.

11 Sometimes I feel like we're pushing too hard 12 and sometimes I feel like we weren't pushing.

13 Anyway, they came back to us with -- and

\~l 14 finally gave us the questionnaires. And five of the 15 people who were contaminated had not responded to the 16 questionnaire. And you say to the Licensee, "Well, what 17 about these five who haven't reJponded? Do you know how 18 their contamination" --

l 19 "Well, no." "But what about the 20 questionnaires?" "Well, you realize the questionnaire is 21 voluntary."

22 "Well, to heck with this voluntarily business.

23 You need to find out what's going on here." And you know, 24 then they would respond and come back and they figured out D

\- 25 that everybody had drunk out of the cooler.

NEAL R. GROSS COURT REPORTER 8 ANO TRANSCPJSERS 1323 RHOOE 18LANO AVENUE, N.W.

(202) 234-4433 WASHINGTON D.C. 20006 (202) 234-4433

71 1 So I would have profited by having been g- 2 experienced in this process before, I guess.to put it b 3 mildly.

4 -

MR. GLENN: Yes. Did you get any support in 5 terms of the procedures of an AIT in -- any administrative 6 support from AEOD, anything like that?

7 MR. DWYER: We had -- you know, we have been 8 hit from all directions for information, whether it's the 9 attorneys or whether it's the media or whatever.

10 And one of the things that AEOD did for us was 11 to go through their tracking systems and provide some 12 information on previous events on other Licensees that the 13 media wanted. But other than that, no.

/'T ,

-' 14 MR. MADISON: AIT is chartered by the Regional 15 Administrator.

16 MR. GLENN: Oh, okay. I'll just mention that i 17 had so much more support than you had. But it's amazing.

18 MR. MADISON: Any other lessons learned, Jim? l l

. 19 MR. DWYER: Well, I think that -- you know, and 20 this is -- let me bounce around a little bit here. If NRC l

21 is going to be concerned with, you know, 50 percent of the 2

22 ALI or 25 percent of the ALI or something, I think that we 23 need to have our regulations reflect that.

24 I know that prior to this, even though we hN l- 25 didn't talk about ALIs prior to new Part 20, you know, we NEAL R. GROSS COURT REPORTERS AND TRANSCRISERS 1323 RHOOE 18 LAND AVENUE, N.W.

(202) 2344433 WASHINGTON, D C. 20006 (202) 234 4433

72 1 still talked about 25 percent thresholds and things like

/<~s 2 that.

k_

3 And unfortunately, we lost that in the rewrite.  !

4 I understand that there is some rewriting going on Part 20 l 5 now that will include if there's any willfulness involved 6 here, we want to hear about it.

7 MR. GLENN: Yes. And in fact, we requested a 8 copy of that and received it.

9 MR. DWYER: Okay.

10 MR. GLENN: So we were taking a look at that.

11 MR. DWYER: Okay. You know, there are some --

12 you know, really I think NIH is a lot more' sophisticated 13 than a lot of our broad scope licenses. And I've never (O

_) 14 inspected MIT, but I would suspect that they are also.

15 And you know, we don't have -- you know, for 16 something to this degree, for internal contamination of -- f 17 you know, where you're talking about involving a medical - ,

18 - we don't really delve into that too much with the 1

19 Licensee and the licensing process. l i

i 20 And I think things like, you know, how to use 21 REACTS and in response -- you know, where medical l 22 intervention is required and stuff, I think, needs to be - l 23 - we need to look at that a little bit more.

24 This business of having the investigation going l

[ b

\' 25 on concurrently, I'm not sure if this is due ground for us NEAL R. GROSS COURT REPORTERS AND TRANSCRt8ERS 1323 RHODE ISLANO AVENUE, N.W.

(202) 234-4433 WASHINGTON, D.C. 20006 (202) 234-4433 I

73 1 or not, but I would hate to see somebody have to go

- 2 through it again.

3 You know, it's not really -- you can't do.a 4 regular incident, response, investigation because of 5 encumbrances.

6 And you know, I'm not sure how it gets handled, 7 but something needs to be done to address it before, you 8 know, somebody else goes out there and has the same 9 problem.

10 MR. GLENN: Okay.

11 MR. DWYER: Let's see, I'm trying to think 12 here. No, I think that's about it at this point, at least 13 the higher points.

O .14 You know, my biggest concern is that I don't --

15 I think the best thing that could have happened was if 16 they had somebody at a higher level with more experience 17 than me. I mean, right now they've got -- they're putting 18 together a special inspection team that's being led by a 19 Deputy Division Director.

20 So, you know, maybe that or a Branch Chief was 21 the appropriate level to start with.

22 MR. GLENN: Okay. You mentioned about how 23 somebody -- maybe we should speak to -- I guess you 24 mentioned Susan. Anybody else who you think might be k-- 25 useful for us to speak to?

NEAL R. GFH3SS

CDURT REPORTERS AND TRANSCRSERS 1323 RH00E ISLANO AVENUE, N.W.

(202) 234 4433 WASHINGTON D.C. 20006 (202) 234-4433

74

.1 MR. DWYER: I mean, if you want to talk to f 2 Jerry Kenna, the investigator. Although, I'm not sure i

( 3 about his availability.

4 --

MR. GLENN: Maybe we'll try to confirm his 5 status somewhat, but -- okay, we will be faxing you that 6 sheet I was talking about that talks about reviewing the 7 transcripts.

8 And then you can get together with Cherie 9 Siegel on the phone, and we'll figure out how to get you a 10 copy of the transcript so you can take a look at what you 11 said, and whether anything needs to be corrected.

12 MR. DWYER: Okay.

13 MR. MADISON: Jim, what's the best fax number

[}

b- 14 for us to send this to you directly?

15 MR. DWYER: Let's see, 337-5269.

16 MR. MADISON: Okay, thank you.

17 MR. GLENN: Okay. It's 2:45 in the afternoon, 18 and the interview is concluded. Thank you, Jim.

19 MR. DWYER: Thanks. Bye.

20 (Whereupon, the interview was concluded at 2:44 21 p.m.)

22 23 24 25 NEAL R. GFN3SS COURT REPORTER 8 AND TRANSCRISER8 1323 RHODE 68 LAND AVENUE, N.W.

(202) 2344433 WASHINGTON, D.C. 20006 (202) 234 4433

CERTIFICATE 7~ This is to certify that the attached proceedings before the United States Nuclear Regulatory Commission in the matter of:

Name of Proceeding: INT. OF JAMES DWYER Docket Nuraber: (NOT ASSIGNED)

Place of Proceeding: ROCKVILLE, MARYLAND were held as herein appears, and that this is the original transcript thereof for the file of the United States Nuclear Regulatory Commission taken by me and, thereafter reduced to typewriting by me or under the direction of the court I reporting company, and that the transcript is a true and i O' accurate record of the foregoing proceedings.

1 1

k l KARINA WOOD Official Reporter 1 Neal R. Gross and Co., Inc. )

I l

l l

l 1

l

(

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVENUE, N W.

(202) 234-4433 WASHINGTON. D C. 20006 (202) 234-4433 j