Text
,
l Dotket No. 50-354 l
Mr. R. L. Mitti, General Manager l
Nuclear Assurance and Regulation l
Public Service Electric & Gas Company P. O. Box 570, T22A Newark, New Jersey 07101 i
l
Dear Mr. Mitti:
SUBJECT:
OFFSITE DOSE CALCULATION MANUAL l
t By letter dated April 26, 1985, you transmitted the Hope Creek Offsite Dose
}
Calculation Manual (0DCM) for staff review.
Review of this document has j
resulted in the enclosed comments. You are requested to review the enclosed comments and submit for staff review a revised ODCM which resolves these coments.
Please respond to this request within 3 weeks frcm the date of this letter.
l Feel free to call the NRC Licensing Project Manager, Dave Wagner (301) 492-8525,
]
if you have any questions regarding this request.
Sincerely, Walter R. Butler, Chief Licensing Branch No. 2 Division of Licensing
Enclosure:
As stated i
cc: See next page DISTRIBUTION: DockefFili NRC PDR Local PDR PRC System NSIC l
LBe2 Reading EHylton'~ ~
DWagner Dewey,0 ELD ACRS (16)
JPartlow i
BGrimes EJordan JSwift RFell JFairobent l
LB#2/DL/PM LB#2/DL/BC 1 4
DWagner:lb WButler i
09/f[85 g/4985 i
l 8511060100 851024 PDR ADOCK 05000354 A
PDR i
l
.s.
, _.,..,.._...,__.__.,,,...... ~,,,., _ -.. _. _ _,..
kO QiG
,d' o,,
UNITED STATES g
NUCLEAR REGULATORY COMMISSION 2
gy E
WASHINGTON, D. C. 20555 s4 J
\\..... #
OCT 2 41985 Docket No. 50-354 Mr. R. L. Mitti, General Manager Nuclear Assurance and Regulation a
Public Service Electric & Gas Con.pany P. O. Box 570, T22A hewark, New Jersey 07101
Dear Mr. Mitti:
SUBJECT:
0FFSITE DOSE CALCULATION MANUAL 1
By letter dated April 26, 1985, ycu transraitted the Hope Creek Offsite Dose Calculation Manual (0DCM) for staff review.
Review of this docunent has resulted in the enclosed comments. You are requested to review the enclosed concents and submit for staff rcview a revised ODCM which resolves these consents.
Please respenc to this request within 3 weeks frem the dcte of this letter.
Feel free to call the NPC Licensing Project Manager, Dave Wagner (301) 492-8525, if you have any questions regardine this request.
Sincerely, Walter R. But er, Chief Licensing Branch No. 2 i
Division of Licensing
Enclosure:
As stated l
cc: See next page 4
i
ttr. R. L. Mitti Public Service Electric & Cas Co.
Hope Creek Generating Statinr.
i cc:
Grecory Minor Susan C. Renis i
Richard Hutbard Division of Public Interest Advocacy i
Dale Bridenbaugh New Jersey State Department of FEB Technical Associates the Public Advocate 1723 Hamilton Avenue, Suite K Richard J. Hughes Justice Comples San Jose, California 951E5 CN-850 Trenton, New Jersey 08625 Trcy B. Conner, Jr. Esquire Office of Legal Counsel Conner & Wetterhahn Department of Natural Resources 1747 Pennsylvania Avenue N.W.
and Envircreental Control Washington, D.C.
20006 89 Kings Highway P.O. Box 1401 Dover, Delaware 19903 4
kichcrd Fryling, Jr., Esquire Mr. K. W. Burrcwes, Project Engineer Associate General Solicitor Bechtel Power Corporation l
Public Service Electric a Gas Company 50 Beale Street P. O. Box 570 T5E P. O. Box 3965 Newark, New Jersey 07101 San Francisco, California 94119 Mr. J. M. Ashley Resident Inspecter Senior Licensing Engineer U.S.N.R.C.
c/c Public Service Electric & Gas Co.
F. C. Ecx 241 Bethesda Office Center, Suit 550 hancocks Bridge, New Jersey CE03E 4520 East-West Highway Bethesoa, Maryland 20814 Richard F. Engel Dcruty Attorney General Mr. A. E. Giardino Division of Lev Manager - Quality Assurance EhC Environmental Protection Section Public Service Electric & Gas Co.
Richard J. Hughes Justice Ccnplex P. O. Box A CH-112P Hancocks Bridge, New Jersey 08038 Trenton, New Jerse) 08625 Mr. Robert J. Touhey, Mr. Anthony J. Pietrofitta Acting Director General Manager DLREC - Division of Power Production Engineering Environmental Cortrol Atlantic Electric 89 Kings Highway 1199 Black Horse Pike P. O. Box 1401 Pleasantville, New Jersey 08232 Dover, Delaware 19903 Regional Administratcr, Region I Mr. R. S. Salvesen U. S. Nuclear Regulatory Commission General Manager-Hope Creek Operatiun 631 Park Avenue Public Service Electric & Gas Co.
King of Prussia, Per.nsylvania 19406 i
P.O. Box A Hancocks Bridge, New Jersey 08038 l
Public Service Electric & Gas Co. Hope Creck Generating Station cc:
Mr. B. A. Preston Public Service Electric & Gas Co.
Hope Creek Site MC12Y Licensir,9 Trailer 12LI Foot of Button wood Road Hcncock's Bridge, New Jersey 08038 Ms. Rebecca Green New Jersey Bureau of Radiation Protection 3E0 Scotch Road Trenton, New Jersey 08628 i
)
~
COMMENTSONTHEHOPECREEKODCM(REV.0) i
_Pa_g_e Coment F.D-12 In two locations, the sigma sign is missing.
In the equation, the division sign is not clear; it resembles a plus sign.
2.0-17 The division sign resem W a plus sign.
2.0-19 Add the units (mrem /hr,:. uCi/m ) to the heading of Table 21-1.
2.0-21 Add the correct reference for the bio-accumulation factors for silver.
3.0-2 A line of text has been omitted at the top of page 3.0-2.
" monitor setpoints.
That is, setpoint adjustments are not" 3.0-4 The top line on page 3.0-4 duplicates the last line on page 3.0-3.
3.0-4 The parameter (X/Q) is defined to be "the highest annual relative concentration atthesiteboundaryinanysecgor",with a numerical value of 2.65 x 10- sec/m3 at the exclusion area boundary (901m) in the northwest sector. Staff calculations indicate 8.7x10-gnannualaverageX/Qvalueof i
sec/m3 in the northwest sector 1
at a distance of 901m. Slightly higher (10-15%) values are calculated in the southeast and south sectors for the same exclusion area boundary distance.
Provide ju 2.65x10-gtificationfortheuseof sec/m3 as the " highest annual relative concentration at the site boundary," considering specifically the appropriateness of the assumption of straight-line airflow without modifica-tion for spatial and temporal variations l
in trajectories.
3.0-8 In the RETS, in Technical Specifications and 3.11.2.1 and 4.11.2.1.2, I-133 is included throughout with I-131, tritium and all radionuclides in particulate form with half-lives i
l greater than 8 days.
1-133 must be included in the ODCM Section 3.2 and i
correspondingly throughout the ODCM.
l
Page Coment
-8 3.0-12 Numerical val sec/m3
.a_n_d,4.4 x 10~y ~gf 9.9 x 10 are presented for X/Q' and D7iT', respectively, on page 3.0-12, with a cross r.gf.grence to Table 3.2-4.
The value for X/Q' apparently was calculated at a distance of 8 km in the northwest sector, and this___
value is the maximum of all the X/Q values presented in Table 3.2-4.
However, the corresponding D3 at that location is exceeded by D7Q values in the west-northwest sector and in the northwest sector at 6.4 km. Provide justificagonfortheuseof 2
4.4 x 10- m as the value for D/Q' to be assumed "for other pathways and non-tritium nuclides" (as described on page 3.0-12).
3.0-46 Ge?erally, the X/Q and D/Q values presented in Table 3.2-4 (page 3.0-46) are in reasonable agreement $30%) with the values calcu-lated by the staff. However, some signi-ficant differences (ogr a factor of 3) are noted in several D/Q values. For example, the staff gas calculated a value of 8.3 x 10-i 2
m in the east sector at a distance of 5 g @g compared to the value of 2.2 x 10-1 m presented in the table. Similar' discrepanci'es 'are noted for the east-northeast sector at 5.5 km and for the west-northwest sector at 5 4 km. Provide corroboration that the D/Q values presented in Table 3.2-4 accuratel reflect calculations.
Also, provide and D7U values for site boundary distances.
3.0-51 The atmospheric dispersion model described in general in Section 3.3 (Page 3.0-51) is simple enough to be fully described in two pages.
Cross-referencing to tables and sections in the FSAR is cumbersome, and could result in inconsistencies if the FSAR is amended without also amending the ODCM.
1
l In Section 3.3 of the ODCM, provide a complete description of the atmospheric dispersion model used for calculation of al average relative concentration X/Q and relative deposition
) values presented in the ODCM. Also, provide a description of the meteorological data used in the dispersion model (i.e., period of record, heights of measurement, and atmospheric stability indicator).
4.0-5 Show on these figures the location and 4.0-6 identity of the effluent radiation 4.0-7 monitors, i.e., the liquid radwaste discharge line monitor, the cooling tower blowdown effluent line monitor, the filtration, recirculation, and ventilation system noble gas monitor, the south plant vent noble gas monitor, and the north plant vent noble gas monitor.
4.0-17 It is recommended that this section be revised to state that, in the event that the annual land use census or other information should indicate that individual members of the public may be inside the site boundary more than a few hours each year, doses to such members of the public shall be calculated according to the methods of Sections 2.2 and 3.2.
4.0-18 We do not object to the elimination of the integrated population dose calculation.
5.0-3 In accordance with the RETS, samples for radiciodines and for particulates should be collected at the same locations; thus station IFl should be included in Table 5.1-1, section I.(b) as an iodine sampling station.
3.0-46 In accordance with the RETS and with 5.0-2 ODCM Table 3.2-4 ("The real receptor 5.0-3 with the highest exposure is an infant consuming the milk of a cow pastured at 4.9 miles in the W sector."), one sampling station collecting particulates and iodines should be located in the W sector at about 4.9 miles. At the time of the site visit, i
?
a list of sampling stations was provided the NRC/NRR/RAB representive; this list included a milk sampling station identified as 13E3, 4.9 miles W of vent, local fann. Such a sampling location 13E3 also appeared on Figure 6.1-2 of the HCGS ER0L. A sampling station in the vicinity of 13E3 is needed.
5.0-6 In Table 5.1-1, provide a legible sampling station identifer for the station at 7.4 miles NNE of the vent.
5.0-7 The infonnation on these pages of Table 5.0-8 5.1-1 should be put in the correct order; this involves both the page number and the designation "Page 6 of 9" and "Page 7 of 9."
5.0-7 In section VI.(a) correct the typo in the note on I-131 analysis.
5.0-8 In Table 5.1-1, section IV.(c), " gamma isotopic analysis on quarterly composite" must be changed to " gamma isotopic analysis on monthly composite."
5.0-11 Provide clear Figures 5.1-1 and 5.0-12 5.1-2.
These maps are illegible.
5.0-11 Sampling stations 451 and 6S1 are shown on Figure 5.1-1; identify in Table 5.1-1 what samples will be taken at these stations.
5.0-11 In Figure 5.1-1, in sector 6, one of the two sampling station identifiers is illegible.
.-